module 2 5 dmp ipmi
Post on 03-Apr-2018
229 Views
Preview:
TRANSCRIPT
-
7/28/2019 Module 2 5 Dmp Ipmi
1/20
DPM - IPMI
Product Support Engineering
VM ware Co n f i d en t i a l
-
7/28/2019 Module 2 5 Dmp Ipmi
2/20
VI4 - Mod 2-5 - Slide 2
Module 2 LessonsLesson 1 vCenter Server High Availability
Lesson 2 vCenter Server Distributed Resource Scheduler Lesson 3 Fault Tolerance Virtual Machines
Lesson 4 Enhanced vMotion Compatibility
Lesson 5 DPM - IPMI
Lesson 6 vAppsLesson 7 Host Profiles
Lesson 8 Reliability, Availability, Serviceability ( RAS )
Lesson 9 Web Access
Lesson 10 vCenter Server Update Manager Lesson 11 Guided Consolidation
Lesson 12 Health Status
-
7/28/2019 Module 2 5 Dmp Ipmi
3/20
VI4 - Mod 2-5 - Slide 3
Module 2-5 Lessons
Lesson 1 Overview of DPM and IPMILesson 2 Configuring IPMI settings
Lesson 3 Testing IPMI
Lesson 4 Enabling Power Management
Lesson 5 Troubleshooting IPMI
-
7/28/2019 Module 2 5 Dmp Ipmi
4/20
VI4 - Mod 2-5 - Slide 4
Managing Power ResourcesThe VMware Distributed Power Management (DPM) feature allows a
DRS cluster to reduce its power consumption by comparing per-hostcapacity versus demand and then taking (or recommending) theappropriate actions.
If sufficient excess capacity is found, DRS places one or more hosts instandby mode, migrating any virtual machines running on them to other
hosts and then powering them off.When capacity is deemed to be inadequate, DRS brings hosts out of standby mode (powers them on) and migrates virtual machines, usingVMotion, to them.
-
7/28/2019 Module 2 5 Dmp Ipmi
5/20
VI4 - Mod 2-5 - Slide 5
Managing Power Resources
ESX/ESXi hosts cannot automatically be brought out of standbymode unless there is a running vCenter Server in the cluster.
VMware DPM can use Intelligent Platform Management Interface(IPMI) , Integrated Lights-out (iLO) and Wake-On-LAN (WOL) asthe wake protocols that bring hosts out of standby mode.
Any host that supports both IPMI and WOL, defaults to using IPMI.
-
7/28/2019 Module 2 5 Dmp Ipmi
6/20
VI4 - Mod 2-5 - Slide 6
Configure IPMI Settings for VMware DPMIntelligent Platform Management Interface (IPMI) is a
hardware level specification that describes an interface for monitoring and controlling computers.
A Baseboard Management Controller (BMC) implements theinterface, providing a gateway for accessing hardware controlfunctions, and allowing the interface to be accessed from a remote
system using serial or LAN connections.This remote management can occur when there is no operatingsystem running on the host and when the system is powered off.
You must configure the BMC and IPMI settings of each host.Ensure that the BMC LAN channel is configured to be alwaysavailable and to allow operator privileged commands.
BMC configuration steps vary according to manufacturer and model.
-
7/28/2019 Module 2 5 Dmp Ipmi
7/20
VI4 - Mod 2-5 - Slide 7
Configure IPMI Settings for VMware DPM
To configure IPMI settings1 Select the host in the VI Client inventory.
2 Click the Configuration tab to display it.
3 Click IPMI Settings.
-
7/28/2019 Module 2 5 Dmp Ipmi
8/20
VI4 - Mod 2-5 - Slide 8
Configure IPMI Settings for VMware DPM
4 Click Properties.
5 Provide the following information:User name and password for a BMC account. (This user name must have theability to remotely power the host on.)
IP address of the NIC associated with the BMC. (This IP address should bestatic or a DHCP address with infinite lease.)
MAC address of the NIC associated with the BMC.6 Click OK.
-
7/28/2019 Module 2 5 Dmp Ipmi
9/20
VI4 - Mod 2-5 - Slide 9
Test Wake-on-LAN for VMware DPMThe use of Wake-on-LAN (WOL) for the VMware DPM feature is fullysupported
Before testing WOL, ensure that your cluster meets the following prerequisites:Your cluster must contain at least two ESX 3.5 (or ESXi 3.5) or later hosts.Each hosts VMotion networking link must be working correctly. The VMotionnetwork should also be a single IP subnet, not multiple subnets separated byrouters.The VMotion NIC on each host must support WOL. To display the
WOLcompatibility status for each NIC on a host, select the host in the inventorypanel of the VI Client, choose the Configuration tab, and click Network Adapters.
The NIC must have Yes displayed in the Wake On LAN Supported column. The switch port that each WOL supporting VMotion NIC is plugged into should beset to auto negotiate the link speed, and not set to a fixed speed (for example,1000 Mb/s). Many NICs support WOL only if they can switch to 100 Mb/s or lesswhen the host is powered off.
After you verify these prerequisites, test each ESX/ESXi host that is going to useWOL to support VMware DPM. When you test these hosts, ensure that theVMware DPM feature is disabled for the cluster.
-
7/28/2019 Module 2 5 Dmp Ipmi
10/20
VI4 - Mod 2-5 - Slide 10
ESX/ESXi host for Wake-on-LAN operability
To test an ESX/ESXi host for Wake-on-LAN operability1 Place the host in standby mode by clicking the Enter Standby Modecommand on the hosts Summary tab in the VI Client. This completely powersdown the host.
2 Attempt to bring the host out of standby mode by clicking the Power Oncommand on the hosts Summary tab.
3 Observe whether or not the host successfully powers back on.For any host that fails to exit standby mode successfully, select the host inthe cluster Settings dialog boxs Host Options page and change its Power Management setting to Disabled. After you do this, VMware DPM does notconsider that host a candidate for being powered off.
CAUTION Ensure that any host being added to a VMware DPM cluster that uses WOL as a wake protocol is tested and disabled from usingpower management if it fails the testing. If this is not done, VMware DPMmight power down hosts that it subsequently can not power back up.
-
7/28/2019 Module 2 5 Dmp Ipmi
11/20
VI4 - Mod 2-5 - Slide 11
Enabling VMware DPM for a DRS Cluster
Configure the power management automation level, threshold, andhost level overrides.
These settings are configured under Power Management in the clustersSettings dialog box.
-
7/28/2019 Module 2 5 Dmp Ipmi
12/20
VI4 - Mod 2-5 - Slide 12
Enabling VMware DPM for a DRS Cluster
Automation Level
Whether the host power state andmigration recommendationsgenerated by VMware DPM areexecuted automatically or notdepends upon the power
management automation levelselected for the feature.
The options available are:Off
Manual
Automatic
-
7/28/2019 Module 2 5 Dmp Ipmi
13/20
VI4 - Mod 2-5 - Slide 13
Enabling VMware DPM for a DRS Cluster DPM Threshold
The power state (host power on or off)recommendations generated by theVMware DPM feature are assignedpriorities
ranging from priority-one to priority-fiverecommendations.
These priority ratings are based on theamount of over or under utilizationfound in the DRS cluster and theimprovement that is expected from theintended host power state change
A priority one recommendation ismandatory, while a priority fiverecommendation brings only slightimprovement
NOTE The DRS threshold and the VMwareDPM threshold are essentially independent.You can differentiate the aggressiveness of themigration and host power staterecommendations they respectively provide.
-
7/28/2019 Module 2 5 Dmp Ipmi
14/20
VI4 - Mod 2-5 - Slide 14
Enabling VMware DPM for a DRS Cluster Host Options -Host-Level Overrides
When you enable a host in the DRScluster to use VMware DPM, it inheritsthe clusters power managementautomation level.
Create an override by selecting thehost in the cluster Settings dialogboxs Host Options page and clickingits Power Management setting.
You can change this setting to thefollowing options:
Disabled
Always Manual
Always Automatic
NOTE Times for the Last Time Exited Standbyfield are derived from the vCenter Server eventlog. If this log is cleared, the times are reset toNever.
-
7/28/2019 Module 2 5 Dmp Ipmi
15/20
VI4 - Mod 2-5 - Slide 15
Troubleshooting IPMI
Check the VC logs for [updateIpmi] or IPMIlib: or IPMI lib:
[2008-11-12 16:27:41.232 01444 verbose 'App'] [VpxVmomi] Invoking [updateIpmi] on[vim.HostSystem:host-10] session [D004135C-7928-4A51-BA2F-D26B3ED59C1B]
[2008-11-12 16:27:41.232 01444 verbose 'App'] Arg ipmiInfo:
(vim.host.IpmiInfo) {
dynamicType = ,
bmcIpAddress = "10.21.73.113",
bmcMacAddress = "00:19:99:17:11:D6",
login = "admin",
password = (not shown),
}
-
7/28/2019 Module 2 5 Dmp Ipmi
16/20
VI4 - Mod 2-5 - Slide 16
Troubleshooting IPMI
Invalid MAC Address[2008-11-12 16:27:27.701 00592 verbose 'App'] [VpxVmomi] Invoking [updateIpmi] on[vim.HostSystem:host-10] session [D004135C-7928-4A51-BA2F-D26B3ED59C1B]
[2008-11-12 16:27:27.701 00592 verbose 'App'] Arg ipmiInfo:
(vim.host.IpmiInfo) {
dynamicType = ,
bmcIpAddress = "10.21.73.113",
bmcMacAddress = "00:19:99:17:11:D",
login = "admin",
password = (not shown),
}
***
***
[2008-11-12 16:27:27.779 00796 warning 'App'] [VpxdMoHost] IPMIlib: reference MACaddress did not match one read from BMC of target host cs-tse-f113
-
7/28/2019 Module 2 5 Dmp Ipmi
17/20
VI4 - Mod 2-5 - Slide 17
Troubleshooting IPMI
Invalid Username[2008-11-12 17:06:45.154 03204 verbose 'App'] [VpxVmomi] Invoking [updateIpmi] on[vim.HostSystem:host-37] session [D004135C-7928-4A51-BA2F-D26B3ED59C1B]
[2008-11-12 17:06:45.154 03204 verbose 'App'] Arg ipmiInfo:
(vim.host.IpmiInfo) {
dynamicType = ,
bmcIpAddress = "10.21.73.113",
bmcMacAddress = "00:19:99:17:11:D6",
login = " administrator ",
password = (not shown),
}
***
***
[2008-11-12 17:06:46.217 03260 error 'App'] [VpxdMoHost] IPMI lib: GetMacAddr callfailed. API error 13 (hex).
-
7/28/2019 Module 2 5 Dmp Ipmi
18/20
VI4 - Mod 2-5 - Slide 18
Troubleshooting IPMI
Invalid IP Address[2008-11-12 17:29:29.967 02228 verbose 'App'] [VpxVmomi] Invoking [updateIpmi] on[vim.HostSystem:host-37] session [D004135C-7928-4A51-BA2F-D26B3ED59C1B]
[2008-11-12 17:29:29.967 02228 verbose 'App'] Arg ipmiInfo:
(vim.host.IpmiInfo) {
dynamicType = ,
bmcIpAddress = " 10.21.35.113 ",
bmcMacAddress = "00:19:99:17:11:D6",
login = "admin",
password = (not shown),
}
***[2008-11-12 17:29:50.982 00796 error 'App'] [VpxdMoHost] IPMI lib: GetMacAddr callfailed. API error 13 (hex).
-
7/28/2019 Module 2 5 Dmp Ipmi
19/20
VI4 - Mod 2-5 - Slide 19
Lesson 2-5 Summary
Learn how to enable IPMI on a Cluster Learn how to test IPMI settings
Learn how to troubleshoot IPMI
-
7/28/2019 Module 2 5 Dmp Ipmi
20/20
VI4 - Mod 2-5 - Slide 20
Lesson 2-5 - Lab 5
Module 2-5 Lab 5 VMware vCenter DPM/IPMI
Enable IPMI on a Cluster
Test IPMI settings
Troubleshooting IPMI