n u c o r h i g h w a y.com nucor steel marion, inc. tl 3 system 4400 lb pickup truck 1800 lb small...

Post on 30-Mar-2015

216 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

TL 3 System4400 lb Pickup Truck

1800 lb Small Car

Impacting at 62 mph

25 degrees

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

18 wheelers? NOT TESTED

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

System Components

Simple System

Line Posts Cable Hook Bolts Turnbuckles End treatment

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Line Posts

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Turnbuckles

Standard Cable = 1 x 750’ (229m)

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Turnbuckles

Like This!

NOT like this!

When turnbuckle interferes with post, leave off bolt

Best practice is NOT to install all three turnbuckles in same space

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

End Treatment

5 SPACES @ 6’ - 6” = 32’ - 6” 3 SPACES @ 6’ - 3” = 18’ - 9”

51’ – 3”

3 CRP posts @ 6’-3”

6 End Terminal Posts @ 6’-6”

Line posts (refer to plans)

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

CRP Posts

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Delineation

3M #94 Primer

3M High Intensity Prismatic #3931 Reflective Sheeting

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Maintenance of System

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Common Impacts – SIMPLE REPAIR

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

CRP Posts

Line PostRepair

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Line Post RepairMake SURE:

Cable on correct side

Hook bolt nuts hand tightened

Cable Heights TOP = 29.5” ±1”

MIDDLE = 25.5” ±1”

BOTTOM = 21.5” +0”/-2”

Check and record tension

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Uncommon Impacts

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Releasing Tension

1. Loosen turnbuckle(s)2. Cable grip and winch – pull towards

accident3. Ratchet come-along and 2 cable

grips4. Knock over CRPs5. LAST CASE – CUT THE CABLE

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

QuickDe-tensioning

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

CRP Repair

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Re-tensioning – STANDARD CABLE

Check Temperature Chart 15% higher

0 to 1.5 years After first major freeze After impact

Tension tolerance is +15-20% or up to 2500 lbs.

Check within first month after installation Periodically over the first year

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

CheckingTension

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Additional information, photos, videos, and

manuals available at

nucorhighway.com

U.S. High-Tension Cable System

Nucor Steel Marion, Inc. n u c o r h i g h w a y .com

Questions ?

U.S. High-Tension Cable System

top related