2.7V325FBCAP0325P270S17ESHLR-0325C0-002R7A2

OPERATINGENVIRONMENT/POWER&ENERGY OperatingTemperatureRange Standard(-40°Cto65°C) Extended(-40°Cto85°C)MaximumStoredEnergy,Emax

7 at2.7V 0.32Wh at2.3V 0.23WhGravimetricSpecificEnergy7 at2.7V 5.0Wh/kg at2.3V 3.6Wh/kgUsableSpecificPower7 at2.7V 7.0kW/kg at2.3V 5.1kW/kgImpedanceMatchSpecificPower7 at2.7V 14.6kW/kg at2.3V 10.6kW/kg*Resultsmayvary.Additionaltermsandconditions,includingthelimitedwarranty,applyatthetimeofpurchase.Seethewarrantydetailsforapplicableoperatinganduserequirements.

ELECTRICALSPECIFICATIONSRatedVoltage,VR 2.7VDCSurgeVoltage1 2.85VDCRatedCapacitance,C2 325F

CapacitanceToleranceMin./Max. 0%/+20%Average4 +5%/+10%

InitialDC-ESR,RDC3

Max. 1.9mΩAverage4 1.7mΩ

MaximumLeakageCurrent5 0.45mAMaximumPeakCurrent,Non-repetitive6 270A

TYPICALLIFETIMECHARACTERISTICS*ProjectedDCLifeatRoomTemperature8(ContinuouschargingatVRand25±10°C)

10years

DCLifeatStandardHighTemperature8(ContinuouschargingatVRand65°C)

1,500hours

DCLifeatDe-RatedVoltage&HigherTemp.8(Continuouschargingat2.3Vand85°C) 1,000hours

ProjectedCycleLifeatRoomTemperature8(Constantcurrentcharge-dischargefromVRto1/2VRat25±10°C)

500,000cycles

ShelfLife(Storedwithoutchargeat25±10°C) 4years

TYPICALTHERMALCHARACTERISTICSThermalResistance,Rth(Housing) 8.8°C/WThermalCapacitance,Cth 75.6J/°CUsableContinuousCurrent(ΔT=15°C)9 30AUsableContinuousCurrent(ΔT=40°C)9 49A

DIMENSION&WEIGHTD(+0.8) 33.0mm L(±1.0) 62.5mmH(±0.3) 3.0mm d(±0.1) 2.0mmA(±0.1) 11.9mm B(±0.1) 10.0mmE(±0.1) 5.0mm F(±0.1) 5.9mmNominalWeight 65.3g

SAFETY&ENVIRONMENTALRoHS&REACH Compliant

FEATURES

• HighperformanceproductwithlowESR• Exceptionalshockandvibrationresistance• Longlifetimeswithupto500,000dutycycles*• CompliantwithUL,RoHS,andREACHrequirements• RecommendedApplication:

Automotive,UPSSystem,Actuators,EmergencyLighting,Telematics,SecurityEquipment,BackupSystem,andOthers

SeeNoteonMountingRecommendations10

3001962-EN.1 Page2of2

2.7V325FBCAP0325P270S17

NOTE1. SurgeVoltage

Absolutemaximumvoltage,non-repetitive.Thedurationmustnotexceed1second.

2. RatedCapacitance(MeasurementMethod)

˃ Constantcurrentchargewith10mAperfaradtoVR.e.g.Incaseof2.7V325Fcell,10*325=3,250mA=3.25A

˃ ConstantvoltagechargeatVRfor5min.˃ Constantcurrentdischargewith10mAperfaradto0.1V.

𝑪=𝑰×(𝒕𝟐)𝒕𝟏)𝒗𝟏)𝒗𝟐

where𝑪isthecapacitance(F);𝑰istheabsolutevalueofthedischargecurrent(A);𝒗𝟏isthemeasurementstartingvoltage,0.8ⅹVR(V);𝒗𝟐isthemeasurementendvoltage,0.4ⅹVR(V);𝒕𝟏isthetimefromdischargestarttoreach𝒗𝟏(s);𝒕𝟐isthetimefromdischargestarttoreach𝒗𝟐(s)

3. InitialDC-ESR(MeasurementMethod)

˃ Constantcurrentchargewith10mAperfaradtoVR.˃ ConstantvoltagechargeatVRfor5min.˃ Constantcurrentdischargewith40*C*VR[mA]to0.1V.

e.g.Incaseof2.7V325Fcell,40*325*2.7=35,100mA=35.1A

𝑬𝑺𝑹𝑫𝑪 = △ 𝒗𝑰

where𝑬𝑺𝑹𝑫𝑪istheDC-ESR(Ω); △ 𝒗isthevoltagedropduringfirst10msofdischarge(V); 𝑰istheabsolutevalueofthedischargecurrent(A)

4. Average

˃ Typicalpercentagespreadthatmaybepresentinoneshipment.5. MaximumLeakageCurrent(MeasurementMethod)

˃ ThecapacitorischargedtoitsratedvoltageVRat25°C.˃ Leakagecurrentistheamountofcurrentmeasuredafter72hoursofcontinuous

holdingofthecapacitoratVR.

6. MaximumPeakCurrent˃ Currentthatcanbeusedfor1-seconddischargingfromtheratedvoltagetothe

half-ratedvoltageundertheconstantcurrentdischargingmode.

𝑰= ½𝑽𝑹△𝒕/𝑪5𝑬𝑺𝑹𝑫𝑪

where𝑰isthemaximumpeakcurrent(A);𝑽𝑹istheratedvoltage(V);△ 𝒕isthedischargetime(sec);△ 𝒕=1secinthiscase;𝑪istheratedcapacitance(F);𝑬𝑺𝑹𝑫𝑪isthemaximumDC-ESR(Ω)

˃ Thestatedmaximumpeakcurrentshouldnotbeusedinnormaloperationandisonlyprovidedasareferencevalue.

7. Energy&Power(BasedonIEC62391-2)

˃ MaximumStoredEnergy,Emax(Wh)=½𝐂𝑽𝑹𝟐

𝟑𝟔𝟎𝟎

˃ GravimetricSpecificEnergy(Wh/kg)=𝑬𝑴𝒂𝒙𝑾𝒆𝒊𝒈𝒉𝒕

˃ UsableSpecificPower(W/kg)=𝟎.𝟏𝟐𝑽𝑹𝟐

𝑬𝑺𝑹𝑫𝑪×𝑾𝒆𝒊𝒈𝒉𝒕

˃ ImpedanceMatchSpecificPower(W/kg)=𝟎.𝟐𝟓𝑽𝑹𝟐

𝑬𝑺𝑹𝑫𝑪×𝑾𝒆𝒊𝒈𝒉𝒕

8. DCLifeandCycleLifeTest˃ End-of-Life(EOL)Conditions:

- Capacitance: -20%fromtheratedminimumvalue- DC-ESR: +100%fromthespecifiedmaximuminitialvalue

˃ CapacitanceandESRmeasurementsaretakenat25°C.

9. UsableContinuousCurrent˃ Maximumcurrentwhichcanbeusedwithintheallowedtemperaturerangeunder

theconstantcurrentdischargingmode.

𝑰= 𝜟𝑻𝑹𝒕𝒉×𝑬𝑺𝑹𝑫𝑪

where𝑰isthemaximumcontinuouscurrent(A);𝜟𝑻isthechangeintemperature(°C);𝑹𝒕𝒉isthethermalresistance(°C/W);𝑬𝑺𝑹𝑫𝑪isthemaximumDC-ESR(Ω)

10. MountingRecommendations˃ Provideproperlyspacedholesformountingaccordingtothespecifiedcelldimension

inordertominimizetheterminalsofthecellbeingmechanicallystressed.˃ Donotplaceanythrough-holesdirectlyunderneaththecellorinthecloseproximity

ofthecell.Allowatleast5mmdistancefromanypointontheouterdiameterofthecelltotheouterdiameterofanythrough-hole.

˃ Protective coating of components on the PCB is strongly recommended in order toreducetheriskofthecomponentsbeingdamagedinaneventofelectrolyteleakage.

˃ Provide at least 2mm clearance from the safety vent and do not position anythingnearthesafetyventthatmaybedamagedbytheventrupture.

˃ AssemblethecellonthePCBtakingintoaccountthatthecellmaynotbecompletelyhermetic during its lifetime. Electrolyte vapor and gases generated during normaloperationmayescapethepackage.

˃ Soldering guide for small and medium size cells is available and can be found atwww.nesscap.comunderSupport->Download.

Whenordering,pleasereferencetheMaxwellModelNumberbelow.MaxwellModelNumber:BCAP0325P270S17

MaxwellPartNumber:133523

NesscapModelNumber:ESHLR-0325C0-002R7A2

MaxwellTechnologies,Inc.GlobalHeadquarters3888CalleFortunadaSanDiego,CA92123USATel:+1(858)503-3300Fax:+1(858)503-3301

MaxwellTechnologiesSARoutedeMontena65CH-1728RossensSwitzerlandTel:+41(0)264118500Fax:+41(0)264118505

MaxwellTechnologies,GmbHLeopoldstrasse24480807MunichGermanyTel:+49(0)8941614030Fax:+49(0)89416140399

MaxwellTechnologiesShanghaiTradingCo.,LtdRoom1005,1006,1007No.1898,GonghexinRoad,JingAnDistrict,Shanghai200072P.R.ChinaTel:+862136804600Fax:+862136804699

NesscapCo.,Ltd.17,Dongtangiheung-ro681beon-gil,Giheung-gu,Yongin-si,Gyeonggi-do17102RepublicofKoreaTel:+82312890721Fax:+82312866767

Thedatainthisdocument3001962correspondstothedatainNesscapdocument20170711Rev09.Theinformationinthisdocumentiscorrectattimeofprintingandissubjecttochangewithoutnotice.Imagesarenottoscale.MAXWELLTECHNOLOGIES,MAXWELL,MAXWELLCERTIFIEDINTEGRATOR,ENABLINGENERGY’SFUTURE,NESSCAP,BOOSTCAP,DCELL,CONDISandtheirrespectivedesignsand/orlogosareeithertrademarksorregisteredtrademarksofMaxwellTechnologies,Inc.,and/oritsaffiliates,andmaynotbecopied,imitatedorused,inwholeorinpart,withoutthepriorwrittenpermissionMaxwellTechnologies,Inc.Allcontentscopyright©2017MaxwellTechnologies,Inc.Allrightsreserved.Noportionofthesematerialsmaybereproducedinanyform,orbyanymeans,withoutpriorwrittenpermissionfromMaxwellTechnologies,Inc.

Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information: Maxwell Technologies:

  BCAP0325 P270 S17

top related