New Product Introduction
Agilent8860 GCand 8890 GC
Workshop PharmaPT. Vision Scientific
SurabayaApril 25, 2019
1
CLICK HERE FOR CONTACT US
2
8860 GC 8890 GC
Built on core 7890/8890 architectures … Modern UI … Advanced Intelligence Capabilities
3
Expanded Capabilities to meet more types of routine analysis needs
8860 GC
3rd Detector - Top• FPD (Env/Food, other)• TCD
3rd GSV (Energy & Chemical)
3rd Detector - Side• TCD (Energy & Chemical)• ECD • 2 LSV’s
4
Expanded Capabilities to meet more types of routine analysis needs
8860 GC
Based on 6th Generation EPC• Improved reliability*• More EPC capabilities
3rd Detector - Top• FPD (Env/Food, other)• TCD
3rd GSV (Energy & Chemical)
3rd Detector - Side• TCD (Energy & Chemical)• ECD • 2 LSV’s
Electronic Pneumatics Regulation*
8860 Inlets/Detectors:• Improved detector MDL’s
- ECD*- NPD* (Blos bead)
5
Three detectors by 8860Volatile Aromatics, Halogenated Hydrocarbons, and Organophosphorus pesticides in drinking water
1. Chloroform2. Carbon tetrachloride3. Tetrachloroethylene4. Benzene5. Toluene6. Ethylbenzene7. m-,p-Xylene
8. o-Xylene9. Dichlorvos10. Demeton-S11. Dimethoate12. Methyl parathion13. Malathion14. Parathion
Headspace
• Unpurged CFT split between FID and ECD
• HP-5ms UI (ECD) & DB-624 UI (FID)
• Nitrogen carrier
• Area RSD < 2.5% (n=10)
• RT RSD < 0.017% (n=10)
• Calibration linearity R2 > 0.999
Liquid injection
• SSL to FPD+
• DB-1701
• Nitrogen carrier
• Area RSD < 1.5% (n=6)
• RT RSD < 0.019% (n=6)
• Calibration linearity R2 > 0.999
ECD
FID
FPD+
6
Simplicity of manual operation …with the precision of digital control
EPR – Electronic Pneumatics Regulation
vs.
7
Built on core 7890/8890 architectures … Modern UI … Advanced Intelligence Capabilities
8860 GC
Touchscreen• Configuration/flowpath• Setpoints/actuals• Status
• Signal Plot
DA Express: A Simple Complete Analysis Solution
8
Combine the experience and insight of our best scientists with the functionality of our integrators
Simplified Workflow from a Browser Interface
DA Express: A Simple Complete Analysis Solution
9
Combine the experience and insight of our best scientists with the functionality of our integrators
Simplified Workflow from a Browser Interface
Your secure enterprise network
Methods– Edit entire sections at once
Sequences– Editable sequence table
Calibration and Analysis– Same five simple screens
Store unlimited methods and sequences
All served up from the Browser Interface
10
DA Express: A Simple Complete Analysis SolutionSimplified Workflow from a Browser Interface
Methods– Edit entire sections at once
Sequences– Editable sequence table
Calibration and Analysis– Same five simple screens
Store unlimited methods and sequences
All served up from the Browser Interface
11
DA Express: A Simple Complete Analysis SolutionSimplified Workflow from a Browser Interface
12
DA Express: A Simple Complete Analysis SolutionSimplified Workflow from a Browser Interface
Methods– Edit entire sections at once
Sequences– Editable sequence table
DA Express– Same five simple screens
Store unlimited methods and sequences
All served up from the Browser Interface
• NOT for compliant needs
• NOT for OpenLab users– No customization (macros,
calcs, reports, etc)
Ideal forSimple workflows
New UsersArea%
13
8860 – Smart and connectedNext Generation Smart Connected GC
Powerful Browser user Interface
— Connect to 8860 from anywhere in your secure enterprise network
— Status
— Methods
— Sequence
— Maintenance
— Diagnostics
— Help
14
8860 – Powerful browser user interface
Status
Methods
Sequence
Maintenance
Diagnostics
Help
Status Method
Check your system configuration, and access status of instrument
and run
Call up method parametersAdjust and save as needed.
15
8860 – Powerful browser user interface
Status
Methods
Sequence
Maintenance
Diagnostics
Help
Sequence Maintenance
View your sequence, edit and append as needed.
Pre-empt unexpected failures by setting up preventative maintenance minders
16
8860 – Powerful browser user interface
Status
Methods
Sequence
Maintenance
Diagnostics
Help
Diagnostics Help
The 8860 is always checking its systems and can self-diagnose
A wealth of information at your fingertips including tutorials and guided
troubleshooting
18
Highlight Features
Column smart key and USB
… and other
product design enhancements
Touchscreen, 7 inch• View at the GC
Enhanced DiagnosticsMaintenanceInstrument StatusExtensive User Info
• Capacitive touch screen
Browser Interface• GC info available via
PC, Tablet, Mobile• All GCs
19
Enhanced Features
3rd or 4th Aux Carrier Detector• FID• ECD• TCD• NPD
6th Generation EPC• 8 EPC’s
• Autonomous Leak-Check(Hands-Free)
3rd Top Detector• TCD• FPD
8 heated zones
22
Demonstration of 8890 EPC precision esp at high heating rates
min0 1 2 3 4 5 6 7 8
min0 1 2 3 4 5 6 7 8
min0 1 2 3 4 5 6 7 8
min0 1 2 3 4 5 6 7 8
min0 1 2 3 4 5 6 7 8
min0 1 2 3 4 5 6 7 8
Jet Fuel Diesel Fuel Vacuum Oil