observer admin training
Post on 13-Oct-2015
32 Views
Preview:
DESCRIPTION
TRANSCRIPT
-
5/24/2018 Observer Admin Training
1/22
Copyright 2011 by Volicon, Inc.Do Not Copy or Distribute
All Rights Reserved
1
Volicon, Inc.Burlington , Massachusetts 01803www.volicon.comsupport@volicon.comTel: +1-781-221-7400
-
5/24/2018 Observer Admin Training
2/22
INTRODUCTION
SYSTEMARCHITECTURE
2
Turnkey Digital video archiving and streaming solutionoffering 24/7 video Monitoring and Logging: Search,Retrieve, View, Analyze, Store and Export content anytimeanywhere in the world
-
5/24/2018 Observer Admin Training
3/22
3
MONITORINGSITE
Observer Central
Server
LAN
Antenna Amp
STB or TVSatellite Amp/
Receiver
STB
STB
Radio Receiver
Radio Receiver
Radio Receiver
Observer Encoder
Audio / Video IN
Observer Encoder
Audio IN
KVM
Local PC Clients
Internet
RouterFirewall
Filtered Power/ UPS
Backup
Remote PC Client
-
5/24/2018 Observer Admin Training
4/22
GETTINGSTARTED
PC CLIENTMINIMUMREQUIREMENTS
See - Observer User Manual
4
INTERCONNECTIONS
Overall Installation Planning - Site Prep Guide
Network
Interconnect network
Insure sufficient bandwidth to stream media
-
5/24/2018 Observer Admin Training
5/22
NETWORKCONFIGURATION
Use Static IP address
Firewall if using Public access
Sufficient bandwidth for streaming
Open the following TCP ports:
80 and 443 (HTTP/ HTTPS Front end
5502 and 8001 (Media streaming )
3306 for database updates
8220 Listener Web service
25 SMTP for email; 162 SNMP alerts
943 and 4504 for Silverlight
3389 VPN connection for support
See - Site Prep Guide for details
-
5/24/2018 Observer Admin Training
6/22
6
PLANRACKLAYOUT, POWER
Place chassis in standard 19-inch rack (see manufacturer instructions)
Make spreadsheet for:
Rack layout Power capacity - Insure sufficient overall wattage
Acquire Uninterruptable Power Source
SHUTDOWNGRACEFULLY- Do not unplug the power cord
Server/Equipment
part number
Description Power Rack SpaceHigh Multiples of 1U, (1.74inch, 44.45 mm)
4-ANL-3U-090 Observer
4 Chan. Anal.
760 W 3U
1U-WEB/SQL 700 W 1U
1x Client PC 400 W
Total 1860 W 4U
-
5/24/2018 Observer Admin Training
7/22
7
Port Labeling, IP Signal Interconnect
RACK_NAMEPosition Server/Rcvr IP A IP B IN 1 IN 2
1 STB1
3 SD-Enc
4 HDI -Enc
5 Centr-Ctl
Assign IP Addresses Label all ports
Construct an interconnect spreadsheet
-
5/24/2018 Observer Admin Training
8/22
CAPTURE CARDS AND BREAKOUT CABLES
Decklink Quad HD/SD-SDI
Video In B Video In CVideo In D
Video Input A
Audio 9 pin Mini-DINbreakout cable
Audio
Breakout cable
Left 1 Right 1
Left 4 Right 4
9-pin
Mini-
DIN
Osprey 450/ 460
Blackmagic Decklink SDI
SDI Source
-
5/24/2018 Observer Admin Training
9/22
MAINTENANCE USERMANAGEMENT
Group
Management
User Management
Add /Edit User
Delete User
Create group
Edit group
-
5/24/2018 Observer Admin Training
10/22
Edit Group
Edit Group Name Select Permissions Add/Update Group
-
5/24/2018 Observer Admin Training
11/22
Edit User
Edit User Name Select Group Check Encoders Add/Update User
-
5/24/2018 Observer Admin Training
12/22
: Software versions displayed:
o Player
o Product
Session Timeout (min)
System date formato dd-mm-yyyy, mm-dd-yyyy
Global Keyword Alert Limitso Trigger on CC keywordso Set Min time between alerts
Default Login Settings
o User name / user password
Miscellaneous Settings
Producer; CMM Settings (optional modules) R/C Timeout
Expired Data Cleanup
o Events; License
o CC; Ratings; Programs
o Clips
o CC Retention (weeks)
Login Page Control
o Login to every accounto Only to Admin
Expired License Information
o Server IP Name
o Expiration date
Maintenance Settings
-
5/24/2018 Observer Admin Training
13/22
:
Tms EPG - EPG Service login Password policyEnable strong password policy
Live StreamingDefault Login Settings
Dashboard channel orderOrder by
o Channel Name or
o Channel Index
Favorites
o OnNeed to configure streamso OffStreams configured by default
National Reviewer (RPM)
SNMP Receivers
Maintenance Settings
continue
-
5/24/2018 Observer Admin Training
14/22
STREAMCONTROL
CENTRALCONFIGURATION
Probes - Defined in hierarchy
PROBEGROUPS
Central Config
Encoders button then enter Group Name
Double click to open a grouplist of Probes
-
5/24/2018 Observer Admin Training
15/22
PROBESERVERS
Add/Edit Probe
button; Edit Icon
-
5/24/2018 Observer Admin Training
16/22
Test Stream
Press the button
- to preview video
When done - Press the button
Edit Encoders
button; Edit Icon
.
-
5/24/2018 Observer Admin Training
17/22
TRANSPORTSTREAMMEDIA-HUBINTERFACE
Create encoders for the Transport Stream interface on the Media-Hub server and then connect thenew encoders to the Central Server:
Create Media-Hub encoders directly on the Media-Hub server (Probe manager utility) - seeCreate Encoders, in the Media-Hub Admin Guide
Then connect the new TS encoders to the Central Server by configuring the Probe Groups,
Probes and Encoders in the Stream Control section of this training guide
-
5/24/2018 Observer Admin Training
18/22
SOFTWAREUPDATES
Upload Probe release installer files to
the Central Server
Central ConfigSW Updates
press select installer file
press button
EditProbe
Select Revision from
SW VersionDropdown
press
-
5/24/2018 Observer Admin Training
19/22
Select Add Encoder from popup menu
Expand Observer Encoder - Display list of encoders
Select Encoder (e.g., E2)
Double click and rename
Press the button
PROBEMANAGERADD, EDITENCODER
-
5/24/2018 Observer Admin Training
20/22
CONTROLCENTER- CREATEENCODERS
Select the server localhost
Tools Create Encoders
Creates all encoders automatically
Help for Top Menu
Help for Top Menu item
Top Menu
-
5/24/2018 Observer Admin Training
21/22
EDITENCODERINPUT, SELECTAUDIODEVICE
Click Encoder
Edit Name
Click Audio Settings Profile
Click ellipsis
Select new audio profile
EDITAUDIODEVICE
-
5/24/2018 Observer Admin Training
22/22
22
Revision Change History
112211 6.0 release, update capture cards, maintenance settings, fault clips, formatting
010411 Media-Hub Interface update
top related