Oil Tank Storage
Installation : Spartan Flood WL
Project number : Sample Application
Customer : Raytec
Processed by : Raytec White-Light Design
Date : 2017
Project description:This is a sample showing an Oil Tank Storage (ATEX) application using Spartan Flood White-Light.
Products used:Spartan Flood 24 WL - SPX-FL24-W-5050 (60W)
The Spartan range is the smartest, most efficient and most maintenance friendly solution for Hazardous Area environments.
Crucial measurements of the area and mounting heights of luminaires must be communicated in writing along with special site conditions, if any.All specification changes must be communicated to Raytec in order for the design to be modified appropriately.
A Maintenance factor of 0.85 is generally used in our
calculations and is in accordance with European standards e.g. EN12464 and CIE 154:2003 guidelines.
The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur.
Guarantee claims for luminaire data are excluded.
Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to third parties.
Oil Tank Storage
Calculation results, Oil Tank Storage
3D luminance (raytracing), Variable view
ObjectInstallationProject numberDate
: Oil Tank Storage: Spartan Flood WL: Sample Application: 2017
UK/Europe: T: +44(0)1670520055 F:+44(0)1670819760Raytec Unit 15 Wansbeck Business Park, Rotary Parkway, Ashington, Northumberland, NE63 8QW, UK
Oil Tank Storage.rdf
Luminance in the illustration:Minimum: : 0 cd/m²Maximum: : 4870 cd/m²
Artificial light calculation : Direct part, with 2 inter-reflections
Calculation results, Oil Tank Storage
3D luminance (raytracing), Variable view
ObjectInstallationProject numberDate
: Oil Tank Storage: Spartan Flood WL: Sample Application: 2017
UK/Europe: T: +44(0)1670520055 F:+44(0)1670819760Raytec Unit 15 Wansbeck Business Park, Rotary Parkway, Ashington, Northumberland, NE63 8QW, UK
Oil Tank Storage.rdf
Luminance in the illustration:Minimum: : 0 cd/m²Maximum: : 7500 cd/m²
Artificial light calculation : Direct part, with 2 inter-reflections
Oil Tank Storage
Description, Oil Tank Storage
Floor plan
ObjectInstallationProject numberDate
: Oil Tank Storage: Spartan Flood WL: Sample Application: 2017
UK/Europe: T: +44(0)1670520055 F:+44(0)1670819760Raytec Unit 15 Wansbeck Business Park, Rotary Parkway, Ashington, Northumberland, NE63 8QW, UK
Oil Tank Storage.rdf
0 5 10 15 20 25 30 35 40 45 50[m]
1 : 500
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0[m] N
Oil Tank Storage
Summary, Oil Tank Storage
Result overview, Storage Tank ATEX
ObjectInstallationProject numberDate
: Oil Tank Storage: Spartan Flood WL: Sample Application: 2017
UK/Europe: T: +44(0)1670520055 F:+44(0)1670819760Raytec Unit 15 Wansbeck Business Park, Rotary Parkway, Ashington, Northumberland, NE63 8QW, UK
Oil Tank Storage.rdf
0 5 10 15 20 25 30 35 40 45 50[m]
0.0
2.5
5.0
7.5
10.0
12.5
15.0
17.5
20.0
22.5
25.0
27.5
30.0[m] N
15 20 30 40 50Illuminance [lx]
GeneralCalculation algorithm used Average indirect fractionHeight of evaluation surface 0.30 mMaintenance factor 0.85
Total luminous flux of all lamps 47472 lmTotal power 936 WTotal power per area (1500.00 m²) 0.62 W/m²
IlluminanceAverage illuminance Eav 46.4 lxMinimum illuminance Emin 14.4 lxMaximum illuminance Emax 99.8 lxUniformity Uo Emin/Em 1:3.21 (0.31)Diversity Ud Emin/Emax 1:6.91 (0.14)
Type No.\Make
Raytec 05/20131 24 Order No. : RL100-50
Luminaire name : RAYLUX 100 50 degEquipment : 1 x Main Voltage 24x LED Panel 39 W / 1978 lm
Description, Oil Tank Storage
3D view, Installation
ObjectInstallationProject numberDate
: Oil Tank Storage: Spartan Flood WL: Sample Application: 2017
UK/Europe: T: +44(0)1670520055 F:+44(0)1670819760Raytec Unit 15 Wansbeck Business Park, Rotary Parkway, Ashington, Northumberland, NE63 8QW, UK
Oil Tank Storage.rdf
Oil Tank Storage
Calculation results, Oil Tank Storage
3D pseudo colours, Installation (E)
ObjectInstallationProject numberDate
: Oil Tank Storage: Spartan Flood WL: Sample Application: 2017
UK/Europe: T: +44(0)1670520055 F:+44(0)1670819760Raytec Unit 15 Wansbeck Business Park, Rotary Parkway, Ashington, Northumberland, NE63 8QW, UK
Oil Tank Storage.rdf
15 20 30 40 50Illuminance [lx]