operating an efficient district cooling plant in water

Post on 11-May-2022

3 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

If you can read this Click on the icon

to choose a picture or

Reset the slide. To Reset: Right click on the slide thumbnail and select ‘reset slide’ or choose the

‘Reset’ button on the ‘Home’ ribbon (next to the font

choice box)

If you can read this Click on the icon

to choose a picture or

Reset the slide. To Reset: Right click on the slide thumbnail and select ‘reset slide’ or choose the

‘Reset’ button on the ‘Home’ ribbon (next to the font

choice box)

Johnson Controls, Inc. —

WILL START ON THE HOUR 5:00 pm GST 8:00 am EST 1:00 pm GMT

Operating an Efficient District Cooling Plant in Water-Stressed Regions Part 1: The Energy-Water Nexus

Johnson Controls, Inc. — 2

Welcome - Webinar Duration: 1 hour 30 minutes - Panelists: Please mute when not talking and silence /shut-off cell phones. - Questions to Presenters: Please type in Questions in the Q&A box at the lower right hand corner of screen. Questions will be answered after the end of the presentation. (If you are just dialed in with audio, send questions to jill.h.woltkamp@jci.com)

- Moderator will hand questions to presenters. Responses to unanswered questions will be provided by Jill Woltkamp after the webinar.

- Webinar (function) questions: Please chat with Cheryl. Use the Chat box in the middle right hand section of the screen and choose - “Chat privately to Cheryl.”

- Survey: Please complete the survey following the webinar

- Webinar Download: Recording and Presentation slides will be available at www.districtenergy.org

If you can read this Click on the icon

to choose a picture or

Reset the slide. To Reset: Right click on the slide thumbnail and select ‘reset slide’ or choose the

‘Reset’ button on the ‘Home’ ribbon (next to the font

choice box)

If you can read this Click on the icon

to choose a picture or

Reset the slide. To Reset: Right click on the slide thumbnail and select ‘reset slide’ or choose the

‘Reset’ button on the ‘Home’ ribbon (next to the font

choice box)

Johnson Controls, Inc. —

International District Energy Association November 19, 2014 Roy Hubbard Johnson Controls, Inc.

Operating an Efficient District Cooling Plant in Water-Stressed Regions Part 1: The Energy-Water Nexus

Johnson Controls, Inc. — 4

Agenda

Why do we need air conditioning?

How does air conditioning work?

How does water play a role in air conditioning?

What roles do weather and climate play in air conditioning?

How can saving energy save water?

What can we do to save energy?

What are the two main choices in air conditioning heat rejection systems?

Johnson Controls, Inc. — 5

Definition: Energy Balance

Energy In

Energy Out

Thermodynamics Law #1

The flow of heat is a form of energy transfer

Johnson Controls, Inc. — 6

Definition: Sources of Energy in a Building

Thermal Loss

Thermal Gain LIGHTING

PEOPLE

EQUIPMENT / PLUG LOAD

INFILTRATION / EXFILTRATION

VENTILATION

HVAC EQUIPMENT

BUILDING ENVELOPE

SOLAR HEAT GAIN

Johnson Controls, Inc. — 7

Definition: Sources of Energy in a Building

Thermal Loss

Thermal Gain LIGHTING

PEOPLE

EQUIPMENT / PLUG LOAD

INFILTRATION / EXFILTRATION

VENTILATION

HVAC EQUIPMENT

BUILDING ENVELOPE

SOLAR HEAT GAIN

Air conditioning allows buildings to be habitable

KEY CONCEPT

The purpose of Air Conditioning is to move unwanted heat from one area (building) to a location

less objectionable (outside)

Johnson Controls, Inc. — 9

How Air Conditioning Systems Move Energy / Heat

Building Energy

Air Handler Fan

Water-Cooled Chiller

Cooling Tower

Air Handler Coil

Atmosphere

Building Energy

Air Handler Fan

Air-Cooled Chiller

Air Handler Coil

Atmosphere

AIR

-CO

OLE

D

WAT

ER-C

OO

LED

= air transfer

= water transfer

= refrigerant transfer

Johnson Controls, Inc. — 10

Definition: Dry Bulb and Wet Bulb

DRY BULB (DB) Temperature of air

measured by a thermometer

Exposed to the air but shielded from radiation and moisture

WET BULB (WB) Minimum temperature

achieved by evaporative cooling

Largely determined by the DRY BULB temperature and HUMIDITY (moisture)

Air-Cooled System

Water-Cooled System

46°C

24°C

Johnson Controls, Inc. — 11

Definition: Air-Cooled Heat Rejection

Air-Cooled System Air-Cooled Radiator

LIQUID OUT

LIQUID IN

AIR IN

WARM AIR OUT

Johnson Controls, Inc. — 12

Definition: Evaporative Cooling

Heat Energy +

Water Vapor Molecules

When EVAPORATION occurs, heat is removed from an object that is being cooled.

Johnson Controls, Inc. — 13

Definition: Water-Cooled Heat Rejection

Body Evaporation Evaporative Cooling Tower

Heat energy +

water vapor molecules

Johnson Controls, Inc. — 14

Definition: Psychrometric Chart

Weather Data Location:RIYADH, ALL REGIONS, SAUDI_ARABIA

Weather Hours0 to 10 to 10 to 10 to 10 to 10 to 10 to 10 to 10 to 1

0 5 10 15 20 25 30 35 40 45 50 55 60DRY BULB TEMPERATURE - °CChart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com

15%

25%

2%4%6%8% RELATIVE HUMIDITY

10% RELATIVE HUMIDITY20%30%40%50%60%70%80

%

90%

5

5 10

1015

15

20

20

25

25

30

30

35 WET BULB TEMPERATURE - °C

35

Chart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.comChart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com

Dry

Bul

b

Johnson Controls, Inc. — 15

Psychrometric Chart for Air-Cooled Systems

Air-Cooled System

LIQUID OUT 54°C

LIQUID IN

60°C

AIR IN 46°C

WARM AIR OUT

57°C

Weather Data Location:RIYADH, ALL REGIONS, SAUDI_ARABIA

Weather Hours0 to 10 to 10 to 10 to 10 to 10 to 10 to 10 to 10 to 1

0 5 10 15 20 25 30 35 40 45 50 55 60DRY BULB TEMPERATURE - °CChart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com

15%

25%

2%4%6%8% RELATIVE HUMIDITY

10% RELATIVE HUMIDITY20%30%40%50%60%70%80

%

90%

5

5 10

1015

15

20

20

25

25

30

30

35 WET BULB TEMPERATURE - °C

35

Chart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.comChart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com

46°C 57°C

Johnson Controls, Inc. — 16

Weather Data Location:RIYADH, ALL REGIONS, SAUDI_ARABIA

Weather Hours0 to 10 to 10 to 10 to 10 to 10 to 10 to 10 to 10 to 1

0 5 10 15 20 25 30 35 40 45 50 55 60DRY BULB TEMPERATURE - °CChart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com

15%

25%

2%4%6%8% RELATIVE HUMIDITY

10% RELATIVE HUMIDITY20%30%40%50%60%70%80

%

90%

5

5 10

1015

15

20

20

25

25

30

30

35 WET BULB TEMPERATURE - °C

35

Chart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.comChart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com

Psychrometric Chart for Water-Cooled Systems

Water-Cooled System

37°C dB 24°C wB

33°C dB 33°C wB

Johnson Controls, Inc. — 17

Air-Cooled vs. Water-Cooled Heat Rejection

Design day is based on DRY BULB temperature

Consumes no water (no evaporative cooling)

Large footprint

Design day is based on WET BULB temperature

Consumes water (evaporative cooling process uses water)

80% LESS AIR FLOW

Air-Cooled System

Water-Cooled System

KEY CONCEPT

Evaporative cooling enables water-cooled

systems to use less energy at the cost of water

consumption.

Johnson Controls, Inc. — 19

Definition: Energy Use and System Lift

Load (weight of the rock)

Lift

(hei

ght o

f the

mou

ntai

n)

Johnson Controls, Inc. — 20

E N E R G Y

Lift

Definition: Energy Use and System Lift

Load

Johnson Controls, Inc. — 21

Energy Use and System Lift - DESIGN DAY

100%

E N E R G Y

Per AHRI: Design Day conditions occur only 1% of the year

Des

ign

Lift

Design Load

Johnson Controls, Inc. — 22

Energy Use and System Lift - DESIGN DAY

Air-Cooled System

Water-Cooled System

Johnson Controls, Inc. — 23

Energy Use and System Lift - DESIGN DAY

Air-Cooled System

Water-Cooled System

46°C

DES

IGN

LIF

T

DES

IGN

LIF

T

24°C

KEY CONCEPT

There are multiple ways to save energy in a chiller plant that are

weather related:

1. Reduce the 2. Reduce the size of the load system lift

(weight of the rock) (height of the mountain)

Johnson Controls, Inc. — 25

Weather Data - Riyadh, KSA

RIYADH, KSA

Johnson Controls, Inc. — 26

Weather Data - Riyadh, KSA

28 31

35 40

43 45 46 45 43 39

33 28

17 18 19 21 21 20 22 23 21 20 19 18

05

101520253035404550

Dry Bulb (C)Wet Bulb (C)

TEM

PE

RAT

UR

E (°

C)

Average Wet Bulb = 12.6 C

Average Dry Bulb = 26.2 C

Dry Bulb (°C) Wet Bulb (°C)

Johnson Controls, Inc. — 27

Weather Data - Riyadh, KSA - Dry Bulb Variation by Hour

Johnson Controls, Inc. — 28

Weather Data - Riyadh, KSA - Wet Bulb Variation by Hour

Johnson Controls, Inc. — 29

Weather Data - Riyadh, KSA - Annual Load Profile

KEY CONCEPTS

- Air Conditioning moves Energy / Heat.

- Air Conditioning rejects heat through air-cooled or water-cooled systems.

- Weather and seasons impact energy use in these systems.

THE ENERGY WATER NEXUS SAVING ENERGY

REDUCES WATER CONSUMPTION

Johnson Controls, Inc. — 32

Definition: THE ENERGY WATER NEXUS

WATER FOR ENERGY

ENERGY FOR WATER

Energy and Water are Linked

Energy and power production requires water.

Water processing, production, distribution, and end use requires energy

Water-cooled district cooling plants also require water

Johnson Controls, Inc. — 33

THE ENERGY WATER NEXUS – Water Cost COMPONENTS OF WATER COST

Pre-Treat

Post-Treat

Dispose Acquire

Transport

Johnson Controls, Inc. — 34

THE ENERGY WATER NEXUS – Water Cost

WATER COST IS INCREASING • Population Growth

• Rising Standards of living – more water intensive

• Environmental pressures

• Infrastructure Costs

• Climate Change

Johnson Controls, Inc. — 35

THE ENERGY WATER NEXUS – Ways to Save Energy

SAVING ENERGY = SAVING WATER = SAVING MONEY

Avoidance Conserve Design Optimize Maintain • Insulation • Low-E Glass • Lighting

• Night setback • Isolate leaks • Lighting • CHW Reset

• District Energy • Highly Efficient and variable speed components, products and systems

• Central Plant and System Optimization

• Scheduled Service • Measurement and Verification plan

Johnson Controls, Inc. — 36

THE ENERGY WATER NEXUS – Ways to Save Water

SAVING ENERGY = SAVING WATER = SAVING MONEY

SAVE WATER : Reduce blow-down in the cooling tower Use well water, river water, sea water, effluent water

SAVE WATER : Use “waste heat” in a heat pump application

SAVE WATER : Collect and re-use cooling coil condensate

SAVE WATER : Use non-evaporative air-cooled heat rejection systems

Johnson Controls, Inc. — 37

Riyadh, KSA

RIYADH, KSA

Johnson Controls, Inc. — 38

Air-Cooled System vs Water-Cooled System - Riyadh, KSA

Assumptions - Energy Evaluated at SAR 0.26/kWh - Water Evaluated at SAR 4.00/m3

0.00

0.40

0.80

1.20

1.60

2.00

2.40

2.80

3.20

0.00

0.20

0.40

0.60

0.80

1.00

1.20

1.40

1.60

Air Cooled Water Cooled

Syst

em W

ater

Use

Gal

/Ton

-Hr

Chill

er P

lant

Sys

tem

Ene

rgy

kW/T

on

& O

pera

ting

Cost

SAR

/Ton

-Hr

Heat Rejection System Type

Annual Peak and Average Energy Use, Operating Costs, and Annual Average Water Use For Various System Types

Riyadh, KSA

Annual Average kW/Ton Annual Peak kW/Ton Operating Cost SAR/Ton-Hr Gal/Ton-Hr

Johnson Controls, Inc. — 39

Air-Cooled & Water-Cooled System Advantages

A-C RADIATOR SYSTEMS • No water consumption/ reduced chemical consumption

• Simplistic closed loop design

• Lowest maintenance

• Often Standard tubes and tube sheets

WATER-COOLED SYSTEMS • Lowest kW/ton

• Smaller footprint

• More supplier options

• Lower first cost

Johnson Controls, Inc. — 40

Summary Why do we need air conditioning? Allows building to be habitable. How does air conditioning work? Move unwanted heat from one area (building) to a location less objectionable. How does water play a role in air conditioning? Evaporation of water allows for energy and cost efficient heat rejection to the atmosphere. What roles do weather and climate play in air conditioning? Weather impacts both load and lift and thus energy consumption.

Johnson Controls, Inc. — 41

Summary Continued How can saving energy save water? Less energy equals less heat of rejection to the cooling tower. What can we do to save energy? Avoidance > Conserve > Design > Optimize > Maintain What are the two main choices in air conditioning heat rejection

systems? Air-cooled systems and water-cooled systems What is the Energy-Water Nexus? Energy Saves Water and Water saves energy! They are intrinsically

linked…

Johnson Controls, Inc. — 42

Air-Cooled System vs Water-Cooled System - Riyadh, KSA

Assumptions - Energy Evaluated at SAR 0.26/kWh - Water Evaluated at SAR 4.00/m3

0.00

0.40

0.80

1.20

1.60

2.00

2.40

2.80

3.20

0.00

0.20

0.40

0.60

0.80

1.00

1.20

1.40

1.60

Air Cooled Water Cooled

Syst

em W

ater

Use

Gal

/Ton

-Hr

Chill

er P

lant

Sys

tem

Ene

rgy

kW/T

on

& O

pera

ting

Cost

SAR

/Ton

-Hr

Heat Rejection System Type

Annual Peak and Average Energy Use, Operating Costs, and Annual Average Water Use For Various System Types

Riyadh, KSA

Annual Average kW/Ton Annual Peak kW/Ton Operating Cost SAR/Ton-Hr Gal/Ton-Hr

What other opportunities exist between

these two solutions?

Not enough energy

Not enough water

Johnson Controls, Inc. — 43

Next Session....Wednesday December 3, 2014

Johnson Controls, Inc. — 44

Questions and Answers - Please type in Q&A box lower right hand corner.

- Moderator will handle questions to presenter.

- Please complete the survey following the webinar

- Webinar will be recorded and available via download or streaming. Presentation slides will be available in pdf format at www.districtenergy.org

- If you are listening to the webinar recording and have questions, send them to jill.h.woltkamp@jci.com

- Register for the second webinar, held at the same time, Wednesday, December 3, 2014.

Johnson Controls, Inc. — 45

Continue the Discussion

top related