PDI’S NEW WaveStar® BCMS GRAPHIC MONITOR

PDI BRANCH CIRCUIT MONITORING

For M

ore

Info

rmat

ion

Use

your

QR

Read

er

New PDI Exclusive BCMS Plus Offers Additional Monitoring Points • Voltage L-L, L-N for all three phases

• Kw, kva, kvar per panelboard

• kwh per panelboard

• and many other points to allow

complete control

Factory or Field Installed • RPP

• PDU

• JComm®

JComm Retrof ififit Applications• Underfloor enclosure

• Wall mount enclosure

• Existing RPP

• Existing PDU

New monitor designed to provide local

information on current. Allows you to:

• Manage your server loads locally

• Set and manage alarms for current locally

• Monitor current per panelboard and

per circuit

Matches up with PDI’s Branch Circuit

Monitoring System

Branch Circuit Monitoring System • Patented system that allows pro-active

management of branch circuits

• Delivers information to Building

Management/Power Monitoring System via

Modbus® open protocol or SNMP

• Remote and local monitoring and control

over loads

• Increase the reliability of your data center

to the server level

BRANCH CIRCUIT MONITORING SYSTEMS

Power Distribution, Inc. | 4200 Oakleys Court | Richmond, VA 23223

800.225.4838 | 804.737.1703 fax | web site: www.pdicorp.com

©PDI 06/12

new WaveStar® bcms with voltage Additional features:

• Activelymanagethetotalloadperpanelboard• Activelymanagethetotalloadperunit• Remoteandlocalmonitoring

BCMS Plus Basic Program BCMS PlusIndividual Branch Circuit X XSummation of branch breakers per panelboard X XAverage current X XMinimum/maximum current X XAlarm setting X XSummary alarm via Modbus™ X XOptional local monitoring capability X XCurrent demand XReal Power - Kva per panelboard XApparent Power - Kva per panelboard XReactive Power - Kva per panelboard XKilowatt hours per panelboard XPower factor per panelboard XFrequency per panelboard XOver/under voltage per panelboard XInput phase current neutral, ground XPanelboard phase loss A, B, C XVoltage L-L, L-N for 3 phases, panelboard X

new BCMS split core kit• Fitsanyexistinginstallation

• Easytoinstallandconnecttobuildingmanagement system

• Availableforallmanufacturer’s panelboards

also available to fit your:

new BCMS solid core kit• Packagedsolutionusedforany

manufacturer’s panelboards and breakers

• Eachkitallowseconomicalmanagementof two panel boards

• Fitsanyunitinthefield

• Easytoinstallandconnecttobuildingmanagement system