2925

2675

3945

9545

2925

2675

3945

9545

2450

2700

11400

2925

2675

3945

9545

2925

2675

3945

9545

11150

2925

2675

3945

9545

HOUSE TYPE B2HOUSE TYPE B3

4400

WC

ST.

2.7 m²

5025

3500

Kitchen/Dining

18.1 m²

HOUSE TYPE B2

5575

HALL

LIVING ROOM

20.8 m²

5025

LIVING ROOM

16.2 m²

4400

WC

ST.

2.7 m²

5025

3500

Kitchen/Dining

18.1 m²

HOUSE TYPE B3

5575

1125

HALL

3800

BATH

4400

ST.

1.3 m²

3250

2200

HOUSE TYPE B2

5575

BEDROOM 3

7.5m²

2125

3670

BEDROOM 1

15.7m²

Attic

Hatch

2800

BEDROOM 2

11.4m²

1675

1900

E/S

3530

2975

BATH

4400

ST.

0.7 m²

3525

4200

HOUSE TYPE B3

5575

BEDROOM 3

7.5m²

2125

3670

BEDROOM 1

14.4m²

E/S

2800

BEDROOM 2

11.4m²

Attic

Hatch

Folding attic

stairs to provide

access to attic

storage area

3.5m2

HOUSE TYPE B3HOUSE TYPE B2

Obscure

Glazing

Indicitive Solar Panel Position, Final Solar Panel Position Depends

on House Orientation.

The solar panels shown are a provisional option to satisfy

renewable energy requirements of building regs part L. Solar panels

may be omitted in favour of alternative renewable energy source.

FRONT ELEVATION B3-B2 (SEMI-DETACHED)

Ground

Floor Level

+0.000

First Floor Level

+2.925

Attic Storage Level

+5.600

Ridge Level

+9.545

Ground

Floor Level

+0.000

First Floor Level

+2.925

Attic Storage Level

+5.600

Ridge Level

+9.545

KITCHEN/DINING

TOILET

LIVING ROOM

ATTIC STORAGE

BED 2 HALL BED 1

SECTION A-A

Ground

Floor Level

+0.000

First Floor Level

+2.925

Attic Storage Level

+5.600

Ridge Level

+9.545

Ground

Floor Level

+0.000

First Floor Level

+2.925

Attic Storage Level

+5.600

Ridge Level

+9.545

GROUND FLOOR PLAN B3-B2 (SEMI-DETACHED)

AREA B2 = 53.7m², AREA B3 = 52.5m²

OA B2 = 107.4m² / 1156sq.ft, OA AREA B3 = 106.2m² / 1143sq.ft

FIRST FLOOR PLAN B3-B2 (SEMI-DETACHED)

AREA B3/B2 = 53.7m²

REAR ELEVATION B3-B2 (SEMI-DETACHED)

Obscure

Glazing

SIDE ELEVATION - House Type B2

Ground

Floor Level

+0.000

First Floor Level

+2.925

Attic Storage Level

+5.600

Ridge Level

+9.545

Obscure

Glazing

SIDE ELEVATION - House Type B3

s

u

b

s

u

b

s

u

b

s

u

b

s

u

b

s

u

b

s

u

b

s

u

b

s

u

b

s

u

b

s

u

b

sub

SW/A1

.011

s

u

b

s

u

b

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

STOP

B

U

S

B

U

S

B

U

S

B

U

S

STOP

STOP

STOP

STOP

STOP

STOP

REVISIONS

DATE DESCRIPTIONNo.

NOTES:

DO NOT SCALE FROM

DRAWINGS. WORK TO

FIGURED DIMENSIONS

ONLY. ARCHITECT TO

BE NOTIFIED OF ALL

DISCREPANCIES.

DRAWING TITLE:

PROJECT TITLE:DATE:

DRAWN BY:

SCALE: REVISION:

JOB NO: DRAWING NO:

M CROSSAN O ROURKE MANNING

cARCHITECTS

M C

1 Grantham Street, Dublin 8, D08 A49Y, Ireland.

Tel: 01-4788700 Fax: 01-4788711 E-Mail: arch@mcorm.com

HOUSE TYPE B2/B3

Plans, Sections & Elevations

Coosan, Athlone

A1:100

CLMay'20

18029 PL06

TYPE B3/B2 - 3 BED - SEMI-DETACHED

TY

PE

B

3/B

2 - 3 B

ED

- S

EM

I-D

ET

AC

HE

D

N

HOUSE TYPE

2 STOREY

B2

BED 3

Semi-Detached

SQM /107.4 SQF1156

B2

THIS DRAWING TO BE READ IN CONJUNCTION WITH ARCHITECT'S DRAWINGS,

CONSULTANT ENGINEER'S DRAWINGS AND SPECIFICATIONS & LANDSCAPE

ARCHITECTS DRAWINGS

REFER TO ARCHITECT'S SITE PLAN PL02 FOR NORTH ORIENTATION.

LEVELS GIVEN ON HOUSE TYPE DRAWINGS ARE GIVEN TO A LOCAL ABSOLUTE

ZERO LEVEL. FOR SPECIFIC LEVELS DEPENDING ON INDIVIDUAL UNIT

LOCATION, REFER TO ARCHITECT'S CONTEXT SECTIONS AND ENGINEER'S

DRAWINGS WHERE LEVELS ARE ARE ALL GIVEN IN RELATION TO LAND

SURVEYOR'S BENCHMARK BASED ON MALIN HEAD DATUM LEVEL.

ROOF : TO BE FINISHED IN SLATE OR CONCRETE ROOF TILES IN

SELECTED COLOUR OR SIMILAR APPROVED.

WALLS : SELECTED CLAY BRICKWORK WHERE INDICATED OTHERWISE

PAINTED SAND / CEMENT RENDER OR SELF COLOURED

RENDER. EXPRESSED BANDS AROUND EXTERNAL OPES/

EXPRESSED LINTOLS OVER EXTERNAL OPES WHERE

INDICATED TO BE RECONSTITUTED STONE (LIGHT CREAM

LIMESTONE OR GRANITE EFFECT) OR RENDER

JOINERY : ALL WINDOWS AND DOORS, FRAMES AND LEAVES, TO BE

ALUMINIUM POWDER-COATED TO APPROVED COLOUR

OR uPVC.

OBSCURE GLAZING WHERE INDICATED TO SENSITIVE

WINDOWS.

RAINWATER GOODS : GUTTERS, DOWNPIPES, AND FIXINGS TO BE uPVC OR

ALUMINIUM POWDER COATED TO SELECTED COLOUR TO

MATCH ROOF SLATES

G E N E R A L N O T E S

N O T E S O N F I N I S H E S :

SOLAR PANELS: INDICATIVE SOLAR PANEL POSITION, FINAL SOLAR PANEL

POSITION DEPENDS ON HOUSE ORIENTATION. THE SOLAR

PANELS SHOWN ARE A PROVISIONAL OPTION TO SATISFY

RENEWABLE ENERGY REQUIREMENTS OF BUILDING REGS

PART L. SOLAR PANELS MAY BE OMITTED IN FAVOUR OF

ALTERNATIVE RENEWABLE ENERGY SOURCE.

*

HOUSE TYPE

2 STOREY

B3

BED 3

Semi-Detached

SQM /106.2 SQF1143

B3

Side Entrance

KEY PLAN

Scale - 1:2500

30-3-20 General update for planning A