ABBR DESCRIPTION
PLUMBING LEGENDSYMBOL
NOTE: NOT ALL SYMBOLS OR ABBREVIATIONS APPLY
ABBR DESCRIPTION
PLUMBING ABBREVIATIONS
NOTE: NOT ALL SYMBOLS OR ABBREVIATIONS APPLY
ABBR DESCRIPTION
KILOWATTSLABORATORY
MAXIMUM
LEVELPOUNDS
LEAVING WATER TEMPERATURE
THOUSAND BTU PER HOURMINIMUMMISCELLANEOUS
NOT IN PLUMBING WORK
NOT APPLICABLE
NOT IN CONTRACT
NOT TO SCALEON CENTEROUTSIDE DIAMETERPRESSURE DROPPOINT OF CONNECTIONPOUNDS PER SQUARE INCHPOUNDS PER SQUARE INCH GAUGE
KWLAB
MAXMBH
LVLLWT
LBSAC
AMPAGAFF ABOVE FINISHED FLOOR
ABOVE GRADEAMPERES
AIR CONDITIONING
MISCMIN
N/A
NIPWNIC
NTS
BELOW GRADE
BUILDINGBOTTOM OF FOOTING
BRAKE HORSEPOWER
BELOW FINISHED FLOOR
BRITISH THERMAL UNITBRITISH THERMAL UNIT PER HOUR
OCODPD
POC
PSIGPSI
DIAMETER
BOFBLDGBHPBGBFF
BTUBTUH
CONCCLGCFH
DIA
CUBIC FEET PER HOUR
CONCRETECEILING
SLOPESTATIC PRESSURE
STANDARDSTORAGE
SPECIFICATIONS
TYPICALTEMPERATURE
VENT OR VOLTS
UNDERFLOORUNDERGROUND
VENT RISER
UNLESS OTHERWISE NOTED
WEIGHTWATTSVENT THROUGH ROOF
EFFICIENCYEACHEXISTING
ENTERING WATER TEMPERATURESLSP
STOR
SPECSSTD
FLOOR DRAIN
EFFEA(E)
EWTFD
TEMPTYP
UON
UFUG
VVR
FIXTURE UNITFOOT OR FEET
WTW
HORSEPOWERHEAD
INSIDE DIAMETERHEATING, VENT & AIR CONDITIONING
VTR
FUFT
GALVGALGA
GPMGPH
IDHVAC
HPHD
GALLONS PER MINUTEGALLONS PER HOURGALVANIZEDGALLONGAUGE
INCHINVERT ELEVATION
INIE
COTG CLEAN OUT TO GRADE
ELECTRICALELEC
ARCH ARCHITECTURAL
STRUCTURALSTRUCT
NORMALLY CLOSEDNC
NORMALLY OPENNO
DRAWING NUMBERDETAIL NUMBER
DRAWING NUMBERSECTION NUMBER
1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF TITLE 24 OF THE CALIFORNIA CODE OFREGULATIONS (C.C.R.), 2010 CPC.
2. ALL SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, FEDERALAND STATE CODES AND ORDINANCES, AND SHALL MEET ALL REQUIREMENTS OF ALL AUTHORITIES HAVINGJURISDICTION.
3. DRAWINGS SHOWING THE LOCATIONS OF PLUMBING EQUIPMENT, PIPING, ETC. ARE DIAGRAMMATIC AND JOBCONDITIONS WILL NOT ALWAYS PERMIT THEIR INSTALLATION ON THE LOCATIONS SHOWN. THE PLUMBINGDRAWINGS SHOW THE GENERAL ARRANGEMENTS OF EQUIPMENT, PIPING, ETC. AND SHALL BE FOLLOWEDAS CLOSELY AS ACTUAL BUILDING CONSTRUCTION AND THE WORK OF OTHER TRADES WILL PERMIT. THEARCHITECTURAL DRAWINGS SHALL BE PART OF THE WORK INSOFAR AS THESE DRAWINGS FURNISH THECONTRACTOR WITH INFORMATION RELATING TO DESIGN AND CONSTRUCTION OF THE BUILDING.
4. FURNISH AND INSTALL ANY INCIDENTAL WORK NOT SHOWN OR SPECIFIED WHICH ARE NECESSARY TOPROVIDE A COMPLETE AND WORKABLE SYSTEM.
5. PRIOR TO SUBMISSION OF BID, REVIEW FULL SET OF NEW CONSTRUCTION DRAWINGS (INCLUDING ALLOTHER TRADES). INCLUDE ANY ADDITIONAL PIPE OFF-SETS THAT ARE NOT CURRENTLY SHOWN ONDRAWINGS BUT MAY BE REQUIRED TO CLEAR STRUCTURE, FINISHES OR WORK OF OTHER TRADES. NOEXTRA PAYMENT WILL BE ALLOWED FOR WORK RESULTING FROM LACK OF PROPER INITIAL APPRAISAL OFENTIRE SCOPE OF WORK. SUBMIT REQUESTS FOR INFORMATION (RFIs) AS REQUIRED TO ANSWER ANYQUESTIONS THAT MAY ARISE DURING BIDDING PHASE. CLEARLY INDICATE SCOPE INCLUSION ANDEXCLUSION IN BID.
6. FOR PLUMBING PIPING PENETRATING THRU, UNDER AND PARALLEL TO WOOD JOISTS, WOOD BEAMS ANDFOOTINGS, SEE STRUCTURAL DETAILS. PIPE INSTALLATION OTHER THAN SHOWN ON STRUCTURAL DETAILSSHALL BE APPROVED BY THE STRUCTURAL ENGINEER.
7. FOR EXACT LOCATIONS OF PLUMBING FIXTURES, SEE ARCHITECTURAL DRAWINGS.
8. FOR EXACT LOCATIONS OF ROOF DRAINS SEE ARCHITECTURAL DRAWINGS AND DETAILS.
9. COORDINATE WITH CIVIL DRAWINGS FOR SITE CONNECTIONS TO THE COLD WATER, GAS, SANITARY SEWERAND STORM DRAIN STUBOUTS.
10. PROVIDE CLEANOUTS ON DRAINAGE LINES IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE AND ASINDICATED ON THE DRAWINGS.
11. ALL SANITARY SEWER PIPING SHALL BE SLOPED AT 1/4" PER FOOT UNLESS NOTED OTHERWISE.
12. ALL PLUMBING DRAINAGE AND SANITARY VENT TERMINATIONS SHALL TERMINATE IN ACCORDANCE WITHTHE CALIFORNIA PLUMBING CODE.
13. ALL PLUMBING EQUIPMENT SHALL BE SECURELY FASTENED TO THE BUILDING STRUCTURES.
14. WHERE MAIN PIPE SIZE IS NOT INDICATED BETWEEN BRANCH CONNECTIONS ON THE DRAWING, THE PIPESIZE SHALL BE OF THE LARGER PRECEDING PIPE SIZE.
15. ALL VALVES AND ACCESSORIES SHALL BE FULL LINE SIZE. PROVIDE ALL NECESSARY UNIONS, REDUCERSAND STOPS AS REQUIRED WHEN CONNECTING TO EACH FIXTURE AND/OR EQUIPMENT.
16. KEEP ALL PLUMBING PIPING AS HIGH AS POSSIBLE TO THE STRUCTURE ABOVE AND OFFSET PIPING ASREQUIRED.
17. CLOSELY COORDINATE WORK WITH ALL TRADES.
18. CHANGES IN THE DIRECTION OF DRAINAGE FLOW SHALL BE PER CALIFORNIA PLUMBING CODE.
19. ALL SANITARY VENTS SHALL TERMINATE AT LEAST 6" ABOVE ROOF AND AT LEAST 12" FROM ANY VERTICALSURFACE. PROVIDE MINIMUM 10' CLEARANCE FROM VENT TERMINATIONS TO OUTSIDE AIR INLETS OROPENINGS IN THE BUILDING.
20. ALL PIPING PENETRATION THROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH UL-LISTED ANDCALIFORNIA FIRE MARSHAL LISTED SEALANTS. SEE ARCHITECTURAL DRAWINGS FOR ALL LOCATIONS.
21. PROVIDE DIELECTRIC INSULATING CONNECTIONS BETWEEN ALL DISSIMILAR METALS.
22. HOT AND COLD WATER PIPING SHALL BE COPPER TYPE K OR L.
23. SANITARY SEWER AND VENT PIPING SHALL BE ABS, COPPER OR CAST IRON.
24. CONDENSATE DRAIN SHALL BE AS SANITARY SEWER OR COPPER TYPE M.
25. NATURAL GAS PIPING ABOVE GROUND SHALL BE SCHEDULE 40 BLACK STEEL.
DWG. NO. DESCRIPTION
DRAWING INDEX
P0.1 PLUMBING LEGEND AND NOTES
P3.0
P2.0
P2.1
PLUMBING ISOMETRICS
PLUMBING WASTE & VENT
PLUMBING DOMESTIC WATER AND GAS
P2.2 MECHANICAL ROOM PIPING DETAIL
AB.C ABOVE CEILING
PL
EA
SA
NT
C
RE
EK
H
OM
ES
BA
RK
LE
Y A
VE
NU
E, W
AL
NU
T C
RE
EK
, C
A 9
45
97
2-BEDROOM FIRST FLOOR PLAN2-BEDROOM SECOND FLOOR PLAN2-BEDROOM ROOF PLAN
REFERENCE SHEET NOTES
PLUMBING LINES UNDER WINDOW.
PLUMBING LINES UNDER COUNTER.
SS DROP BETWEEN 1ST AND 2ND FLOOR.
2" VENT RISER BETWEEN 1ST AND 2ND FLOOR.
1" CW RISER BETWEEN 1ST AND 2ND FLOOR.
3/4 HW RISER BETWEEN 1ST AND 2ND FLOOR.
FURNACE IN ATTIC. REFER TO MECHANICAL PLANS.
3/4" SS RISER UP TO ATTIC. PROVIDE AIR GAP FITTING (MIN 1" CLEARANCE) FOR CONNECTIONTO CONDENSATE DRAIN.
1-1/4" G RISER BETWEEN 1ST AND 2ND FLOOR.
PROVIDE HW AND SS CONNECTION FROM KS-1 TO DISHWASHER WITH AIR GAP FITTING.
CLOTHES WASHER/DRYER PROVIDED BY OCCUPANT.
LOCATE VTR MINIMUM 10 FEET FROM OPENING INTO THE BUILIDING.
NATURAL GAS METER RECESSED IN WALL. COORDINATE EXACT LOCATION WITH PG&E.
REFER TO CIVIL DRAWINGS FOR CONTINUATION.
PROVIDE DIRT LEG WITH REMOVABLE CAP AT NATURAL GAS CONNECTIONS TO EQUIPMENT.
GENERAL NOTES
SS LINES TO BE SLOPED TO AT LEAST 1.4" PER FOOT.
COORDINATE LOCATION (AND SLOPE IF REQUIRED) OF ALL PIPE ABOVE FIRST FLOOR CEILINGWITH STRUCTURAL REQUIREMENTS OF FLOOR FRAMING.
2-BEDROOM GAS ISOMETRIC PLAN
2" VTR
2" VTR
2" VTR
2" VTR
3/4" HW
3/4" HW
3/4" CW
3/4" CW
IWH-1
T-1
BT-1
L-1
WB-1
1-1/4" G
3/4" G
1/2" CW
3/4" HW
1" CW
3"
G G
GG
3" SS
3" SS
3" SS
1" CW
3/4" HW
3/4" CW
HB-1
HB-1
1/2" CW
3/4" HW
3/4" CW
T-1
L-1
KS-1
1-1/4" G
WCO (TYP)
2-WAY COTG(IE=18" BFF)
2" SS AB.C
3"
G
G
G
G
METER
CLOTHES DRYER (35 MBH)
FURNACE (60 MBH)
47 FT
3 FT
9 FT
4 FT2 FT
IWH-1(199 MBH)
PL
EA
SA
NT
C
RE
EK
H
OM
ES
BA
RK
LE
Y A
VE
NU
E, W
AL
NU
T C
RE
EK
, C
A 9
45
97
3-BEDROOM FIRST FLOOR PLAN3-BEDROOM SECOND FLOOR PLAN3-BEDROOM ROOF PLAN
REFERENCE SHEET NOTES
PLUMBING LINES UNDER WINDOW.
3" SS DROP BETWEEN 1ST AND 2ND FLOOR.
2" VENT RISER BETWEEN 1ST AND 2ND FLOOR.
3/4" CW RISER BETWEEN 1ST AND 2ND FLOOR.
3/4 HW RISER BETWEEN 1ST AND 2ND FLOOR.
FURNACE IN ATTIC. REFER TO MECHANICAL PLANS.
3/4" SS RISER UP TO ATTIC. PROVIDE AIR GAP FITTING (MIN 1" CLEARANCE) FOR CONNECTIONTO CONDENSATE DRAIN.
3/4" G RISER BETWEEN 1ST AND 2ND FLOOR.
PROVIDE HW AND SS CONNECTION FROM KS-1 TO DISHWASHER WITH AIR GAP FITTING.
CLOTHES WASHER/DRYER PROVIDED BY OCCUPANT.
LOCATE VTR MINIMUM 10 FEET FROM OPENING INTO THE BUILIDING.
LOCATE CW, HW AND G SHUTOFF VALVES FOR WATER HEATER IN CABINET.
NATURAL GAS METER. COORDINATE EXACT LOCATION WITH PG&E.
REFER TO CIVIL DRAWINGS FOR CONTINUATION.
PROVIDE DIRT LEG WITH REMOVABLE CAP AT NATURAL GAS CONNECTIONS TO EQUIPMENT.
COORDINATE LOCATION AND SLOPE OF SS PIPE BELOW FLOOR WITH STRUCTURALREQUIREMENTS OF FLOOR FRAMING.
GENERAL NOTES
3-BEDROOM GAS ISOMETRIC PLAN
SS LINES TO BE SLOPED TO AT LEAST 1.4" PER FOOT.
COORDINATE LOCATION (AND SLOPE IF REQUIRED) OF ALL PIPE ABOVE FIRST FLOOR CEILINGWITH STRUCTURAL REQUIREMENTS OF FLOOR FRAMING.
G G
G
2" VTR
2" VTR
2" VTR
2" VTR
3"SS
1"CW
3"SS
3/4"CW
3/4"CW
3/4"HW
HB-1
HB-1
1"CW
3/4"HW
1-1/4" G
IWH-2
GG
GG
1-1/4" G
3/4" G1/2" G
1"HW3/4"CW
1"CW
3/4"HW
3/4"CW T-1BT-1
L-1 KS-1
T-1L-1
WCO (TYP)
2-WAY COTG(IE=15" BFF)
COTG3"SS
3/4" CD
WB-1
2" SS AB.C
METER
DRYER
FURNACE
IWH-2(199 MBH)
G
G
G
(35 MBH)
(60 MBH)
34 FT
36 FT2 FT
18 F
T
CLOTHES
15 FT
PL
EA
SA
NT
C
RE
EK
H
OM
ES
BA
RK
LE
Y A
VE
NU
E, W
AL
NU
T C
RE
EK
, C
A 9
45
97
4-BEDROOM FIRST FLOOR PLAN4-BEDROOM SECOND FLOOR PLAN4-BEDROOM ROOF PLAN
REFERENCE SHEET NOTES
PLUMBING LINES UNDER WINDOW.
3" SS DROP BETWEEN 1ST AND 2ND FLOOR.
2" VENT RISER BETWEEN 1ST AND 2ND FLOOR.
3/4" CW RISER BETWEEN 1ST AND 2ND FLOOR.
3/4" HW RISER BETWEEN 1ST AND 2ND FLOOR.
FURNACE IN ATTIC. REFER TO MECHANICAL PLANS.
3/4" SS RISER UP TO ATTIC. PROVIDE AIR GAP FITTING (MIN 1" CLEARANCE) FOR CONNECTIONTO CONDENSATE DRAIN.
3/4" G RISER BETWEEN 1ST AND 2ND FLOOR.
PROVIDE HW AND SS CONNECTION FROM KS-1 TO DISHWASHER.
CLOTHES WASHER/DRYER PROVIDED BY OCCUPANT.
LOCATE VTR MINIMUM 10 FEET FROM OPENING INTO THE BUILIDING.
LOCATE CW, HW AND G SHUTOFF VALVES FOR WATER HEATER IN CABINET.
NATURAL GAS METER. COORDINATE EXACT LOCATION WITH PG&E.
REFER TO CIVIL DRAWINGS FOR CONTINUATION.
PROVIDE DIRT LEG WITH REMOVABLE CAP AT NATURAL GAS CONNECTIONS TO EQUIPMENT.
GENERAL NOTES
4-BEDROOM GAS ISOMETRIC PLAN
SS LINES TO BE SLOPED TO AT LEAST 1.4" PER FOOT.
COORDINATE LOCATION (AND SLOPE IF REQUIRED) OF ALL PIPE ABOVE FIRST FLOOR CEILINGWITH STRUCTURAL REQUIREMENTS OF FLOOR FRAMING.
2" VTR 2" VTR
2" VTR
2" VTR3/4"CW
3/4" G
AB.C
AB.C
3/4" CD
BT-1
T-1L-1
G G
GG
3"SS
1" CW AB.C
1"CW1""HW AB.C
HB-1
HB-1
1" HW3/4"HW
IWH-2
GG
G
3/4" CW
1"CW AB.C
3/4"HW AB.C
3/4" CW AB.C
3"SS
2"SS
G
1-1/4" G AB.C
1-1/4" G AB.C
1-1/4" G AB.C
1/2" GAB.C
AB.C
AB.C
2-WAY COTG(IE=15" BFF)
COTG (TYP)
2" SS
3" SS
3/4" SS AB.C
WCO (TYP)
KS-1
T-1L-1
BT-1
WB-1
METER
DRYER
FURNACE
IWH-2(199 MBH)
G
G
(35 MBH)
(80 MBH)
43 FT
29 FT16 F
T
CLOTHES
G
G
8 FT
G
G
G
18 FT
PL
EA
SA
NT
C
RE
EK
H
OM
ES
BA
RK
LE
Y A
VE
NU
E, W
AL
NU
T C
RE
EK
, C
A 9
45
97
GENERAL SHEET NOTESREFER TO FLOOR PLAN FOR SIZES.
REFERENCE SHEET NOTES
PLUMBING LINES UNDER WINDOW.
PLUMBING LINES UNDER COUNTER.
SS DROP BETWEEN 1ST AND 2ND FLOOR.
VENT RISER BETWEEN 1ST AND 2ND FLOOR.
3/4" SS FOR FURNACE IN ATTIC SPACE.
WALL CLEANOUT.
LOCATE VTR MINIMUM 10 FEET FROM OPENING INTO THE BUILIDING.
2" SS BFF.
CW RISER BETWEEN 1ST AND 2ND FLOOR.
HW RISER BETWEEN 1ST AND 2ND FLOOR.
PROVIDE HW AND SS CONNECTION FROM KS-1 TO DISHWASHER.
KS-1
L-1
T-1
WB-1
L-1
T-1BT-1
VTR
VTR
SANITARY WASTE & VENT ISOMETRIC 2-BEDROOM
L-1
T-1
SS OUT THE BUILDING
SANITARY WASTE & VENT ISOMETRIC 3-BEDROOM
KS-1
BT-1
T-1
L-1
WB-1
VTR VTR
BT-1
SANITARY WASTE & VENT ISOMETRIC 4-BEDROOM
KS-1
L-1
T-1
WB-1
L-1
BT-1
T-1
VTR VTR
CW LINE INTO BUILDING
COLD & HOT WATER ISOMETRIC 2-BEDROOM COLD & HOT WATER ISOMETRIC 3-BEDROOM COLD & HOT WATER ISOMETRIC 4-BEDROOM
HB-1
L-1
HB-1
T-1
BT-1T-1L-1
WB-1
IWH-1
CW LINE INTO BUILDINGHB-1
KS-1
IWH-2
T-1
L-1
HB-1
WB-1
BT-1
L-1
T-1
CW LINE INTO BUILDING
HB-1
IWH-2
KS-1
HB-1
WB-1 T-1
L-1
BT-1
BT-1
T-1
L-1
KS-1
COTG
2-WAYCOTG
SS OUT THE BUILDING
2-WAYCOTG
SS OUT THE BUILDING
2-WAYCOTG