pn monitoring mallorca, november 2007

Post on 05-Feb-2016

43 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

PN Monitoring Mallorca, November 2007. Mainly Column 64 Hot Pixels. Hot Pixels. M. Smith. Decrease in number of Noisy Pixels due to modified blanking of Column 64 segments in latest BPT update (Rev 1408 onwards). Noisy Pixels. M. Smith. EPIC Telemetry. M. Stuhlinger. - PowerPoint PPT Presentation

TRANSCRIPT

XMM-Newton1

M.Stuhlinger/M.Smith, ESAC

PN Monitoring

Mallorca, November 2007

XMM-Newton2

M.Stuhlinger/M.Smith, ESAC

Hot Pixels

Mainly Column 64 Hot Pixels

M. Smith

XMM-Newton3

M.Stuhlinger/M.Smith, ESAC

Noisy Pixels

Decrease in number of Noisy Pixels due tomodified blanking of Column 64 segments in latest BPT update (Rev 1408 onwards)

M. Smith

XMM-Newton4

M.Stuhlinger/M.Smith, ESAC

EPIC Telemetry

M. Stuhlinger

XMM-Newton5

M.Stuhlinger/M.Smith, ESAC

Offset Median

Increase in offset median: 2 – 5 ADU for Q0 CCDs since ~ Rev 1410

Perhaps other CCDs also, e.g. CCD5

Coincides with latest PN BPT implementation (Rev 1409); however, the changes in the BPT affected CCD11 only…

Similar to onset of theoffset median trend seen in Revs 605 – 660

M. Smith

XMM-Newton6

M.Stuhlinger/M.Smith, ESAC

Offset Median (cont.)

Regarding the Rev 605 – 680 offset median trend:

A correlation was found with the respective Quadrant VC Currents (params F1189-92)

(discussed at the Saclay 2003 Ops Meeting)…

J. Fauste, S. Rives

M. Smith

XMM-Newton7

M.Stuhlinger/M.Smith, ESAC

Offset Median (cont.)

F1189: Q0 VC Current

…however, in the recent trend:

NO correlation with VC Current found.

G. Buenadicha, P. Calderon

M. Smith

XMM-Newton8

M.Stuhlinger/M.Smith, ESAC

Offset VarianceFirst Observations per Revolution

Eclipse Season Boundaries

Behaviour still not understood

M. Smith

XMM-Newton9

M.Stuhlinger/M.Smith, ESAC

M. Kirsch

Energy Scale vs Time very good, esp. for FF mode.

Slight over-correction for EFF mode.

SW mode under-correction, esp. at Mn

(Result of SAS 7.1 Processing)

XMM-Newton10

M.Stuhlinger/M.Smith, ESAC

M. Kirsch

Line width trend is stable

~0.5 ADU/year increase at Mn

(Result of SAS 7.1 Processing)

M. Kirsch

XMM-Newton11

M.Stuhlinger/M.Smith, ESAC

MOS Monitoring

Mallorca, November 2007

XMM-Newton12

M.Stuhlinger/M.Smith, ESAC

MOS1 Bad Pixels MOS2

Still fewer Bad Pixels than before cooling

Nevertheless, steadily increasing trend for most CCDs

M. Smith

XMM-Newton13

M.Stuhlinger/M.Smith, ESAC

New MOS fixed offsets from Rev. 1400 onwards.

MOS fixed offsets lowered by 1 ADU for:

- MOS1 CCD 5

- MOS2 CCDs 1, 2, 3 and 6

M. Smith

XMM-Newton14

M.Stuhlinger/M.Smith, ESAC

M. Stuhlinger

XMM-Newton15

M.Stuhlinger/M.Smith, ESAC

MOS1_Al_width.ps

M. Stuhlinger

XMM-Newton16

M.Stuhlinger/M.Smith, ESAC

M. Stuhlinger

XMM-Newton17

M.Stuhlinger/M.Smith, ESAC

Low Energy Noise (MOS2CCD5-Effect):

MOS2

MOS1

XMM-Newton18

M.Stuhlinger/M.Smith, ESAC

Low Energy Noise (MOS2CCD5-Effect):

XMM-Newton19

M.Stuhlinger/M.Smith, ESAC

Due to Charge Injection?

RAWY

~40

XMM-Newton20

M.Stuhlinger/M.Smith, ESAC

Charge Injection Spectra along RAWY

top related