Oil / Water / Solids Separators
PRODUCT DATA SHEET
water | wastewater | treatment | recycling
Parameter Units CB1.0 CL1.5 CL3.0 CL5.0 CL10 CL15 CL20 CL30 CL60Nominal Flow Rate L/hr 1000 1500 3000 5000 10000 15000 20000 30000 60000Treatment Rate L/hr 800 1000 1500 4200 7200 11000 15000 25000 56000Inlet TPH ppm <5000 (Typical)TPH Discharge Level ppm <5*
Dimensions (not including WOR) mm1255 H360 W1260 L
1240 H445 W1210 L
1240 H445 W1945 L
1525 H650 W2300 L
1418 H1366 W2430 L
1560 H1366 W3206 L
1597 H1765 W3206 L
1797 H1765 W3809 L
1797 H2160 W6059 L
Power Supply v 240v (Single Phase) ~ 415v (3 Phase)Power Consumption (est) kw 0.4 0.4 0.5 1.1 1.1 1.5 3.0 3.0 5.5
STANDARD SPECIFICATIONS
OVERVIEWClearmake oil/water/solids separators are designed to remove free floating hydrocarbons such as diesel, hydraulic fluid and oil as well as heavier suspended solids from a waste water stream. This form of treatment is the minimum required prior to trade waste (sewer) discharge for any wash bay where hydrocarbons may be present. Clearmake Separators are approved by: Sydney Water - Ref: 2006-365WA Water Corporation - Ref: JT1 2010 01224V01
CONSTRUCTIONStandard Clearmake separators are constructed from high quality 304 stainless steel. They can however be upgraded to 316 grade stainless steel for marine or corrosive environments. Larger models have frames manufactured in hot dipped galvanised steel.
Superior Vertical Tube Coalescing (VTC) technology facilitates improved separation, via the unique spiral tubes, designed to assist in exercising the free floating oils to the surface. These specifically designed VTC blocks also provide optimum flow, serviceability and durability.
TREATMENT RATESStandard treatment rates range from 720 to 25,000L/h and custom systems can be manufactured to treat flow rates in excess of 250,000L/h.
*Refer OWS Testing Results, based on removal of free-floating oils and grease
CONTROL SYSTEMSMAK Water controllers are manufactured to Australian Standards and configurations are available to meet Council requirements Australia wide. Plus all separator control systems can be designed and manufactured to meet intrinsically safe standards for hazardous areas, spill control and general or specific mine specifications.
makwater.com.au
WA Perth +61 8 9249 8007 Karratha +61 8 9159 0068 SA +61 8 8395 6122 VIC +61 3 9314 9181 QLD +61 7 5455 6822
24 Feb 16
STANDARD INCLUSIONS + OPTIONS
MODEL SELECTION
Equipment CB1.0 CL1.5 CL3.0 CL5.0 CL10 CL20 CL30 CL60304 Stainless Steel Separator ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
316 Stainless Steel Separator o o o o o o o o
304 Stainless Steel Frame ✓ ✓ ✓ ✓ - - - -
Galvanised Frame - - - - ✓ ✓ ✓ ✓
Skid Mounting o o o o - - - -
Feed Pump Mono ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Feed Pump Diaphragm o o o o o o o -
VTC Coalescing Blocks ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Pump Controller ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Custom Pump Controller o o o o o o o o
Waste Oil Reservoir 20L ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Waste Oil Reservoir - Custom - - o o o o o o
Final Bag Filter - ✓ ✓ - - - - -
Multi Media Filtration o o o o o o o o
Activated Carbon Filtration o o o o o o o o
✓= Standard Supply o = Optional Supply - = Not Applicable
CB 1.0 CL 1.5 CL 3.0 CL 5.0 CL 10 CL 20 CL 30CL 60CL XX Custom supply
304 304 Stainless steel316 316 Stainless steel
XX Frame mountedSM Skid mounted
PC 1020 controller - start/stopPC 1120 controller - Additional high level alarm & strobe lightPC 1220 controller - hour run meter & audiable alarmPX Custom controller
HR Helical rotor pumpDP Diaphragm pump
WOR Waste oil reservoir 20 L standardWOC Waste oil reservoir - custom
X Post treatment standardC Post treatment custom
OWS _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _