product datasheet captair 321 smart & midcap
Post on 22-Jan-2022
1 Views
Preview:
TRANSCRIPT
Safer to operate- ExclusiveErlabfiltrationtechnologycombiningactivatedcarbonandHEPA/ULPAtoadapttothemanipulation - MeetsAFNORNFX15211/ANSIZ9.5-2012filtrationefficiencystandard(class1*and2)- Realtimesensorstodetectmainfiltersaturationwithsolvents,acidsorformaldehyde*- Safetyfilterincaseofmainfiltersaturation - Airfacevelocitypermanentmonitoring - ErlabSafetyProgram:applicationanalysisandvalidation,usageframeworkcertification,usagefollow-up- Connecteddeviceallowingreceptionofsafetynotificationsandusestatus*
Simpler to useRealtimestatuscommunicationbylightandsoundpulses*:-Airfacevelocitydecrease- Mainfiltersaturation- Fanfailure- Excessscheduledworkingtime
Flexibility- Modularfiltrationcolumnadaptingtoapplicationchanges- Easyandfastrelocation
Savings- Noductworkcost- Annualenergycost<100€- Comparedtoanextractionfume cupboard,energysavingscompensate filterreplacementcost
Environment- Nochemicalreleaseintotheatmosphere- Lowenergyconsumption
*:NotavailableonCaptair321Midcap
Captair 321 Smart & MidcapDuctless filtering fume hoods
DowloadoureGuardapplication
Product datasheet
Askforthehighestleveloffiltration performances
Powerfullightguided communication
Connectyourequipmentandbenefitfromtheremoteaccessthankstoourmobilesolutions
694 mm 694 mm
510 mm 510 mm
27 mm
470 mm
700 mm
Heightsaccordingtothefiltrationcolumnconfiguration
Type1Cor1P 1110mm
Please add 150mm between the last filter and the ceiling to allow a good air recirculationandtoreplacefilterseasilyType2Cor1P1Cor1C1P* 1205mm
Type1P2Cor1P1C1P* 1285mm
Tempered glass Trespa® Top LabPLUS 304 L stainless steel
Work surfaces with built in spill tray
Benchcap: fixed work bench Mobicap : mobile rolling cart
800 mm
715mm
780 mm
365mm180 mm
160 mm295 mm
245 mm
1110 mm min
1285 mm max425 mm
620 mm
74 mm
835 mm (without work surface)
822 mm min (with work surface)
FILTRATION TECHNOLOGY
ABOVE
2020 mm min 2195 mm max
2000 mm min2175 mm max
FILTRATION TECHNOLOGY
ABOVE
FILTRATION TECHNOLOGY
ABOVE
2020 mm min 2195 mm max
2000 mm min2175 mm max
FILTRATION TECHNOLOGY
ABOVE
FILTRATION TECHNOLOGY
ABOVE
Communicationinterface*
Simple communication by audible and light pulses: unit running time, air face velocity, automatic filter saturation detection, ventilation settings, fan failure alarm
Filtration technology 1 column that can be configured to handle liquids, powders, or both
Carbon filtration for gases and vapours Following filtration column configuration (see table above)
Particulate filtration for powders Following filtration column configuration (see table above)
eGuard* APP for remote control to monitor the hood, change the settings, and deliver safety alerts immediately to your devices (mobile, tablet and PC)
Internal lighting* LED lighting > 650 Lux
Anemometer* Air face velocity alarm
Anemometer** Air face velocity indicator
Chemical Listing List of approved chemicals
Safety Standards AFNOR NF X 15-211:2009: France - BS 7989: EnglandDIN 12 927:Germany - EN 1822:1998 (HEPA H14 & ULPA U17 Filters) - CE Marking
Air Flow 220 m3/h - 135 CFM
Air Face Velocity 0.4 to 0.6 m/s - 79 fpm to 118 fpm
Voltage/Fequency 220 V / 50-60 Hz
Power consumption 65 W
Sash openings Oblong
Structure Corrosion resistant electro-galvanized steel coated with anti-acid polymer
Side and front panels Chemical resistant acrylic
Filtration module Polypropylene
Equipment
Work Surfaces Trespa® Top Labplus, Glass or 304L Stainless Steel
Molecode* Detection sensor for : Type S, for solvents / Type A, for acids / Type F, for formaldehyde
Benches Mobile (Mobicap) or fixed (Benchcap)
Bench equipment Technical gases outlets, water outlets, front control valves, sink, power sockets (Only compatible with Trespa® Top Labplus worktop and fixed bench)
Particulate Pre-filter Protects the main filter(s) from dustTransparentBack Panel Clear acrylic panel for easy viewing
Accessories
Modular design of the filtration column allows toadapt to every protectionneeds
Carbon filtration for gases and vapoursAS:FororganicvapoursBE+:Polyvalentforacid+organicvapoursF:ForformaldehydevapoursK:Forammoniavapours
Particulate filtration for powdersHEPAH14:99.995%efficiencyfiltrationofparticlesover0.1µminsizeULPAU17:99.999995%efficiencyfiltrationofparticlesover0.1µminsize
Ventilation
MolecodeAutomaticalarmtodetectfiltersaturation
Products handled / Applications
Liquid chemicals handlings Powders handlings Liquid chemicals and powders handlings
Liquid chemicals handlings in clean room
Cus
tom
ized
filtr
atio
n co
lum
n ClassI*accordingtothe
NFX15-211
NA
Class2accordingtothe
NFX15-211
Maximum
protection Maxi
mum
protection Maxi
mum
protection
P C
2C
1C 1P 1P1C
1P2C 2C1P
1C1P
Available filters :
*:NotavailableonCaptairMidcap/**:NotavailableonCaptairSmart
Captair 321 Smart & MidcapDuctless Filtering Fume Hoods
Cap
tair
Smar
t 321
V.0
4_20
21_0
2 - E
rlab
Fran
ce -
Tech
nica
l dat
a ar
e no
t con
tract
ual.
Erla
b re
serv
es th
e rig
ht to
mod
ify th
e pr
esen
t doc
umen
t with
out p
rior n
otic
e.
Erlab’s state of the art Research & Development Laboratory relies exclusively on filtration
1 Erlab R&D Laboratory Theengineersandchemistsinourstate-of-the-artR&Dlaboratoryunderstandmolecularfiltration.Wearecommittedto
designing products that are safe and of the highest quality, strive to improve our products, and continuously develop new productsthatprovidegreaterprotectioninthelaboratory.
2 Strict Safety Standards WeholdourselvestothehigheststandardandadheretothestrictAFNORNFX15-211:2009filtrationsafetystandard
asendorsedbyANSIZ9.5-2012.
3 A Published Chemical Listing Itallbeginshere.Withoutthislisting,wearenotcompliantwithAFNORNFX15-211.Ourin-houselaboratorytests,aswell
asindependenttesting,toverifytheretentioncapacityofover700chemicalsforourfilters.
4 Independent Testing Erlab filters have been independently tested multiple times at various concentrations guaranteeing that our safety
solutionsalladheretothestrictperformancecriteriaoftheAFNORNFX15-211:2009standardassuringthattheemissionconcentrationatthefilterexhaustwillalwaysbelowerthan1%oftheTLV.
5 Application Questionnaire (Valiquest) Ourlaboratoryspecialistswillrecommendtheappropriatefiltrationfumehood,typeoffilter,andpersonalizedadvice.
6 Certificate of Validation for the chemicals used in the hood AcertifiedPhDchemistissuesaCertificateofValidationwithalistofthechemicalsapprovedforuseinthehood.
7 Our Safety Program Webackupourproducts100%.Thisprogramincludesyourspecializedchemicalevaluation,validationofyourhood
uponinstallation,andafiltrationsafetyspecialistatyourservicetoensurethatyourhoodisoperatingtoitsfullpotential.
About Erlab
We provide safety, we protect your healthErlabinventedtheductlessfumehoodin1968.Withmorethan50yearsofexperienceinthefieldofchemicalfiltrationandprotectionoflaboratorypersonnel;weknowtheformulaforsafety.WithErlab,youwillneverhavetowonderorworryifourproductsaresafe.Webuildeachoneofthefollowing7ingredientsintoourproducts,andwithoutallofthem,yourhealthandsafetywillbecompromised.
France +33 (0) 2 32 09 55 80 │ ventes@erlab.net
Germany 0800 330 47 31│ export.north@erlab.net
China +86 (0) 512 5781 4085 │ sales.china@erlab.com.cn
Italy +39 (0) 2 89 00 771 │ export.south@erlab.net
Spain +34 936 732 474│ export.south@erlab.net
United States+1 800-964-4434 │ captairsales@erlab.com
United Kingdom +44 (0) 1722 341 940 │export.north@erlab.net
www.erlab.com