Technical Guidance
Value your job
Morse Taper Implants
Ti External Hex Implants
II Plus Internal Hex Implants
Zygomatic Implants
Surgical Techniques
Bone Grafting and Orthodontic Anchorage
Kits Neodent
Surgical Instruments
14
18
26
58
84
102
110
128
136
154
22
All Neodent efforts aim to provide what is best for you. Such thinking is part of our mission, and, therefore, we hope to serve you forever, and getting better. Neodent’s commitment is to be 100% for you. Being a company 100% for you reflects in our service, in our business relationships, in our product development, in our events and in our scientific research. Whenever you see a Neodent advisor, a collaborator or even a solution for our company with the brand of 100% for you, know that the meaning is the effort, professionalism and great commitment in working to solve everything you need. For us, all stages, from conception to delivery implant, are vital to ensure that quality is being maintained. Is to obtain this result we add all our efforts. For you to be well attended and have excellent products available, plus all the support necessary to further enrich
Much more than dental implants, a
company made100% for you.
meaning is the effort, professionalism and great commitment in working to solve everything you need. For us, all stages, from conception to delivery implant, are vital to ensure that quality is being maintained. Is to obtain this result we add all our efforts. For you to be well attended and have excellent products available, plus
3
Imagine a manufacturing process beginning
from scratch. Based in science and research,
a specialist analyzes the function, the format,
details, and the materials with which the implant
or the component will be made. All of it with lots
of studies and dedication. When this step is
completed, about 20% of the whole work has
been finalized.
Now, it is time to transform
raw-materials into a refined
surgical material, something
that is possible due to the high
industrial technology and also
because of the involvement of
outstanding professionals with
the project. Now, 50% of the whole
project is completed.
Now it is the time when the strict quality control is
applied, including sterilizing, and the withdrawal
of any errors and imperfections. Approximately
75% of the project is now completed. Then,
products are packed and sent to logistics, to our
advisors, and subsequently to you. 100%. The
work is done!
This is the reason why 100% is so important
for us. All steps, from the implant’s concept
through to delivery, are paramount
in order to maintain Neodent’s
quality assurance. We combine
all our efforts to achieve such
percentage, so that you can
be served well, having reliable
products available and all the
support you need to enhance
even further your own talents.
This catalog, in line with any other
of Neodent’s solutions, is the result of 100%
of commitment and dedication from us to
professionals like you.
All Neodent efforts aim to provide what is best for you. Such thinking is part of our mission, and, therefore, we hope to serve you forever, and getting better. Neodent’s commitment is to be 100% for you. Being a company 100% for you reflects in our service, in our business relationships, in our product development, in our events and in our scientific research. Whenever you see a Neodent advisor, a collaborator or even a solution for our company with the brand of 100% for you, know that the meaning is the effort, professionalism and great commitment in working to solve everything you need. For us, all stages, from conception to delivery implant, are vital to ensure that quality is being maintained. Is to obtain this result we add all our efforts. For you to be well attended and have excellent products available, plus all the support necessary to further enrich
meaning is the effort, professionalism and great commitment in working to solve everything you need. For us, all stages, from conception to delivery implant, are vital to ensure that quality is being maintained. Is to obtain this result we add all our efforts. For you to be well attended and have excellent products available, plus
4
In order to guarantee our innovative potential and our
high technology, in 2009 we inaugurated our New
Industrial Complex, featuring 12.000m2, occupying a plot
of land measuring 50.000m2, expanding our production
capacity like no other one in Latin America. The Complex
is equipped with automated machinery, which runs during
3 non-stop shifts. Thanks to such manufacturing potential,
Neodent is also the only Latin American company in its
segment capable of manufacturing its instruments in-
house. The whole project was planned so as to optimize
production and to allow our structure to irradiate our
company’s fundamental values: advances in technology,
respect for human beings and socio-environmental
responsibility.
QUALITY CONTROL
CLEAN ROOM
INSTRUMENTS PRODUCTION
The Industry
PACKAGE
5
Apart from counting on the best and most modern equipments, the
Industrial Complex has an integrated Materials Laboratory (LIM),
aimed directly at research, development and quality control. This Lab
provides: Scanning Electron Microscope (MEV), which guarantees
quality starting from raw-materials and up to the finishing of the products; mechanic and metallographic
tests that assess the long term mechanical endurance, and also allow the micro-structural analysis of
all products. All of it results in excellence for you, our client who gives us your trust and who take our
name into your consulting room.
TRI-DIMENSIONAL CONTROL
PRODUCTION
MECHANICAL TESTS
ROBOTICS
Continuous Development and Quality Control
5
SCANNINGELECTRON
MICROSCOPE
MECHANICAL TESTS
6
The respect to human standards is a principle trait in
the architectural design of the New Industrial Complex,
highlighted by the preference for naturally lit environment
and of the use of materials and technologies that provide
greater thermoacoustic comfort. Now, our employees
have much more infrastructure and ergonomy for their
daily activities. We also have a fully-equipped restaurant
visually integrated into the grove, which attends to the
necessities of the employees and visitors, including
during the diverse events promoted. Concerned with
constant training, we constructed a spacious auditorium
to promote the transmission of knowledge, one of the
important pillars of our essence. Besides intellectual
development, encouragement towards sport is also a
priority: sport courts, a golf course, football and wood
forest for hiking. These values are the base of a strong
trademark that focuses on the people and works for their
wellbeing.
Respect to human standards
AUDITORIUM: CONSTANT PROFESSIONAL TRAINING
MULTI-PURPOSE COURTS
GAMES ROOM
RESTAURANT
7
Starting with the selective garbage collection, up to the treatment of the residual
waters at our Effluents Treatment Station, we perform continuous monitoring
of environmental issues, observing the applicable environmental and sanitation
regulations. When we conceived our new Industrial Complex, we have adopted
social and environmental solutions that are efficient, respecting the needs of
our associates, and reinforcing the image of the company as a reference icon in
environmentally correct actions.
Environment
EFFLUENTS TREATMENT STATION
WATER RETURNED TO THE ENVIRONMENT AFTER TREATMENT
PREFERENCE FOR NATURAL LIGHTING
8
MULTI-DISCIPLINARY LABORATORY
BLUE CLINIC
We count on the scientific support of ILAPEO – The Latin
American Institute of Research and Dental Education -, a
center of excellence in research, advances and innovations
in the clinical practice of dentistry. An institute made up of
professionals, professors and researchers of the highest level
of knowledge who offer post-graduate courses, such as
specialization and master’s degree, recognized by CFO, MEC
and CAPES.
RECEPTION
LIBRARY
AUDITORIUM
9
ContactWhenever you need, you can count on
our different communication channels:
•www.neodent.com.br
Besides our industrial and commercial headquarters
located in Curitiba (PR – Brazil), we count with ten branches,
located in the cities of Sao Paulo, Bauru, Rio de Janeiro, Belo
Horizonte, Porto Alegre, Goiania, Brasilia, Londrina, Recife
and Vitoria. Also, eight authorized distributors extend our
network into seven different Brazilian states (Amazonas,
Bahia, Mato Grosso, Mato Grosso do Sul, Para, Santa Catarina
and Tocantins), apart from our overseas branches located
in Portugal and in the United States. Our international
distribution network reaches thirteen other countries,
namely Argentina, Bolivia, Chile, Colombia, Ecuador, Spain,
Italy, Lebanon, Paraguay, Peru, Dominican Republic, Taiwan
and Venezuela.
A globally renowned company, made
100% for you.
10
The Neoshape CAD/CAM system allows the selection of several materials, such as Zirconia, Cobalt-Chromium,
Titanium and Acrylic, highlighting also the Lithium Disilicate.
The 3shape scanner is the first step for use of the Neoshape system, having as one of its differentials the precision of laser scanning. With it, the Prosthesis Technician can digitalize the plaster models or moldings, and use a simplified 3D modeling software to create parts in a simple and intuitive way.The scanner is sold in Brazil by Neodent, under its partnership with 3shape, a Danish company that is internationally renowned for its 3D scanning technology and quality. The D700 scanner provides micro-metric precision, as it performs a laser reading in 5 different planes, with no human intervention. Professionals who purchase the system can rely on world-class technical support, provided by the company, and also with all technical information needed to properly operate the product.
The Dental Designer software is very flexible and intuitive. Its tools are simple, and allow
the manipulation of the drawings of prosthetic structures, quickly and efficiently.
The software also allows customized anatomic adjustments, such as: spacing for cementing,
coping thickness, adding or reducing the virtual polishing, customization of abutments, among many other possibilities. As the whole
planning occurs virtually, the waste of time and materials is reduced.
PARTNERSHIP BETWEEN NEODENT AND 3SHAPE
DENTAL DESIGNER SOFTWARE
The Dental Designer software is very flexible and intuitive. Its tools are simple, and allow
the manipulation of the drawings of prosthetic
The software also allows customized anatomic adjustments, such as: spacing for cementing,
virtual polishing, customization of abutments, among many other possibilities. As the whole
planning occurs virtually, the waste of time and
CAD CAM SYSTEM
11
It also allows micrometric adjustments, optimizes the production time, 3D virtual polishing and laser scanning
technology.
The milling process begins after the virtual image (previously designed by the prosthesis technician using the Dental Designer software) is forwarded to the CAM software, which will mathematically determine the angles and the axis to be worked on the material, in order to reach a result absolutely identical to what was designed.
Neodent has established a partnership with Ivoclar Vivadent, and with it will bring to the Brazilian market a new option of material for the fabrication of customized prosthesis.It is the Lithium Disilicate (LS2), the E-max® CAD, a material that combines resistance, esthetics and ease of use.
NEODENT’S MILLING CENTER
PARTNERSHIP BETWEEN NEODENT AND IVOCLAR
Cobalt-ChromiumZirconia
The milling process begins after the virtual image (previously designed by the prosthesis technician using the Dental Designer software) is forwarded to the CAM software, which will mathematically determine the angles and the axis to be worked on the material, in order to reach a result absolutely identical to what was
NEODENT’S MILLING CENTER
AVAILABLE MATERIALS:
- Cobalt-Chromium: ideal for metalloceramics prosthesis.- Titanium: material recommended for infrastructure of hybrid prosthesis.- Zirconia: Aesthetics, high resistance, biocompatibility. - E-max® CAD: Translucent, resistance, esthetics and easy to use.
12
Following years of intense researches and development of
new technologies, Neodent has achieved the most modern
and current techniques for the surface treatment of implants:
the Neoporos Surface.
The NeoPoros surface is obtained from the concept of blasting
with abrasive particles, which has automated controls for
speed, direction, pressure and size of the particles that
collide with the implant. With that, we create craters at the
implant’s surface using oxides of controlled granularity. Next,
the surface is leveled using the acid subtraction technique.
Several scientific researches were performed, attesting
the efficiency of the bio-contact quality between bone and
implant, with the NeoPoros surface.
Electronic microscopes of the Neoporos Surface in amplifications of 2000X
and 5000X.
Surface
Continuous Evolution
and Safety Assurance
Controlled roughness to guarantee the size of the pores between 2.5 and 5.0µm throughout the entire implant surface.
13
Bone crest formed over a cervical portion of the Morse taper implants
with Neoporos surface after a period of osseointegration.
Direct contact of the bone to the implant, showing osteogenesis by contact and the osseous induction potential of Neoporos Surface.
Histological study of the bone tissue response
of Neodent implants with Neoporos Surface.
1414
1515
Technical Guidance
16
CorticalImplant Apex
DriveImplant Apex
IMPLANT INDICATION TABLE
Bone type I Bone type II Bone type III Bone type IV
In accordance with the bone classification of Lekholm and Zard (1985).
NEODENT IMPLANTS APEX
AlvimImplant Apex
EXImplant Apex
Morse Taper
Morse Taper
Morse Taper
Cortical with Mount
With Mount
MEDULLAR
17
CONNECTIONS AND TORQUES
20N.cm
20N.cm
20N.cm
20N.cm
10N.cm
20N.cm
Conical Abutment II Plus and Mini Abutment II Plus
Conical Abutment II Plus Angled
Universal Post and Angled II Plus
INT
ERN
AL
HEX
UCLA II Plus
Mini Ball Attachment
Cylinders
0.9 1.2 1.6 Prosthetic Abutments
Conical Abutment (Ø 4.3) and Slim Fit (Ø 4.3) 20N.cm
20N.cm
20N.cm
20N.cm
32N.cm
32N.cm
32N.cm
20N.cm
32N.cm
10N.cm
Mini Conical Abutment (Ø 3.3 and Ø 4.3)
Conical Abutment (Ø 5.0)
Mini Abutment Slim Fit (Ø 5.0)
Mini Abutment Slim Fit (Ø 4.1)
Angled Mini Conical Abutment (Ø 4.1)
Universal Post SF, Personalizable and Angled
UCLA (Ø 3.3; Ø 4.1; Ø 4.3; Ø 5.0)
EX
TERN
AL
HEX
Mini Ball Attachment
Cylinders
SELECTION OF PROSTHETIC COMPONENTS ACCORDINGTO THE ABUTMENT/IMPLANT INTERFACE
Multiple Prosthesis Multiple Prosthesis
Multiple ProsthesisMultiple Prosthesis
A. Overdenture Abutment B. Directly on the Implant
Working manner
Single Prosthesis
Single Prosthesis
Single Prosthesis
Single Prosthesis
Typ
e o
f p
rost
hesi
s 1.Screw-retained
2. Cemented
•Mini Conical Abutment •Transepithelial Abutment
•Micro abutment
•Universal Post•Personalizable Post
•Conical Abutment•CM Abutment
•Anatomical Post•Universal Post•Personalizable Post
•UCLA
•UCLA
32N.cm
15N.cm
32N.cm
10N.cm
32N.cm
32N.cm
15N.cm
15N.cm
15N.cm
CM Mini Conical Abutment, WS and CM Micro Abutment
CM Abutment and WS
CM Angled Mini Abutment and Exact
Universal Post CM and WS
Anatomic Post CM and Exact
Universal Post CM Through Screw
MO
RS
E T
APE
R
Cylinders
Mini Ball Attachment
Universal Post CM and Angled Exact
18
Value your work
19
The cylinders and UCLAs for overcasting
present with perfect adaption and perfect
fitting, following international quality
regulations and standards. The dimensional
tolerance between implants, intermediates
and manufactured belts, as well as the
individual analysis of each piece, are the
differences of these components that pass
through strict industrial quality control at a
micrometric level.
All of these products are manufactured using
the latest equipment, ensuring the best
adaption. Castable polymers sleeves fitted
over the metal bases are replaced with metal
after the overcasting process, thus the pre-
fabricated metalic base has a higher fusion
temperature than the metal to be overcast.
Such polymers facilitate the finishing process
of the parts and ensure the overlapping of
the overcast metal to the pre-manufactured
metal. However, the casting process does
not follow the same quality control that the
manufacturing process does, therefore, the
dental technician should often check for
the absence of positive metallic porosities
in the screw passage tube. Therefore, the
overcastting technique maintains the quality
of the fittings among the guaranteed parts
from the factory and enables the design and
individualization of the
infrastructure, to allow additional material on
the manufactured base to hold its shape.
The use of these products should be
carried out in accordance with the handling
instructions as described in the manual, as
well as in the instructions provided by the
various manufacturers of overcasting alloys.
Thus, the oral rehabilitation team can ensure
success for the technique more safely. For
best results, always use the entire
sequence of Neodent® products (analogues,
abutments, screws, transfer copings, and
protectors).
Believing in the importance of allowing the
customer to choose the product, we offer
different metallic alloy cylinders with pre-
fabricated belts bases for overcasting.:
- Cobalt-Chromium.
- Gold (Gold Alloy).
20
HANDLING OF
CYLINDERS FOR OVERCASTING
Regardless of the type of alloy chosen,
the dental technician should take special
care when handling the pre-fabricated
cylinders, thus improving the quality
of the overcasting and the ceramic
application processes.
1. Waxing:
The edges waxing of the component
cannot overrun the borders that come
into contact with the implant or the
prosthetic component (metallic base
of cylinder), guaranteed to preserve
and adapt the industrial quality control
process.
2. Overcasting:
The prosthetic cylinders are made
non-sterile and are suitable for single
use. The metal bases are manufactured
with alloys that have a high fusion
temperature compared to the metal
that is to be overcast. In cases where the
metal for overcasting has a higher fusion
temperature than the manufactured
parts, they will deform due to high
temperatures. However, if the metal due
to be overcast has a fusion temperature
much lower than the metal in the
base, bonding may occur between the
parts and the base of the component,
which could result in the release of the
infrastructure.
All the cylinders with pre-fabricated
bases are evaluated one by one, from
the reception of the raw material, which
is analyzed before production, to its final
package, ensuring quality throughout
the entire manufacturing process.
3. Finishing and metal polishing:
The disembedding of the casted object
at the coating must be done carefully,
avoiding abrasive jets blasts, which
may alter the prefabricated surface.
It is recommended to machining the
final infrastructure at a low rotation
with the use of refrigeration, with
specific drills for metal. Both of the
areas corresponding to the stop of
the head of the prosthetic screws
inside the passing tube must maintain
their full original shape, without the
presence of positive metal porosities
or deformations. The edges of the
cylinders must be covered by polishing
protectors during the polishing and
the finishing of the infrastructure.
Corrosive materials, such as those
with iron particles, should also not be
used. Very strict criteria should be
applied, because flaws in overcasting
procedure may cause the loss of the
entire work.
4. Ceramic application:
The porcelain choice should
correspond to the used alloy (CoCr,
Tilite or Gold). The ceramic cannot be
applied directly over the manufactured
bases of the cylinder, so that the
waxing and the overcasting ensure a
complete covering of the infrastructure
area in which the ceramic is to be
applied.
21
COBALT-CHROMIUM LINE (CoCr)
The cylinders for overcasting with
prefabricated bases of Cobalt-Chromium
(CoCr) have a high resistance to water
corrosion and elevated mechanical resistance
to withstand occlusal loads. This is an alloy
that has a high biocompatibility and is easy
to use by the technician, with an excellent
acceptance of ceramic application for CoCr.
In addition, this alloy is compatible with
one of the strongest trends in healthcare
worldwide in its absence of Nickel in its
chemical composition, resulting in lower risks
of allergenic reactions when in contact with
living tissues, such as the oral mucosa.
Several cylinders and UCLAs are available
in this alloy, and from the customised
infrastructures of the Neoshape line. Note
the options and mechanical characteristics
(rotational or antirotational) for each case, as
well as the sequence of products found in this
catalogue.
Important informations:
• Melting range: 1.287 to 1.378°C (2.348 to
2.512 °F);
• Density: 8,28 g/cm3;• Coefficient of thermal expansion: 14,2µm/K
(600°C).
An alloy compatible for the overcasting
procedure that is in accordance with
regulations ASTM F1537, ASTM F799, ISO
5832-12 or ISO 5832-4 should be chosen.
The thickness of the metal after overcasting
must be at least 0.5 mm, and can be reduced
during manufacturing and finishing by up to
0.3 mm.
Welding must be done in the range of 1.120 to
1.150°C (2.048 to 2.102 °F)
21
The chemical composition of the high fusion CoCr alloy
follows is in accordance to the international regulation
ASTM F-1537, by following this chemical composition:
CHEMICAL ELEMENT Composition (%)
Cobalt 58 to 69
Chromium 26 to 30
Molybdenum 5 to 7
Nitrogen Max. 0,25
Carbon Max. 0,14
22
ALUMINA LINE
In line with global aesthetic
trends, the following cylinders
are available for the sequence
of Universal Posts made of
Aluminum Oxide: The Alumina line,
indicated to cemented unitary
prosthesis without metal, has the
following characteristics:
• Superior aesthetics and excellent
biocompatibility;
• Absence of metallic margin;
• Best translucency;
• Security on marginal adaptation;
• Effective Mechanical properties;
• No possibility of thermal
conductivity or oxidation;
• Excellent cost/ benefit;
• Technical procedures
widely known by the DENTAL
TECHNICIANS.
Note the sequence of procedures
for utilization of this product found
in this catalogue.
Aluminized feldspathic ceramics
are suitable for the application
of these Alumina cylinders. Some
situations require the customization
of the cylinder in order to avoid
the excess of unsupported
feldspathic ceramics, as following
the manufacturer’s instructions
of the ceramics. For this, the
DENTAL TECHNICIAN must use
aluminized ceramics of margin
or reconstruction, fabricating the
final infrastructure before the
application of the porcelain.
23
GOLD LINE
Among the metallic alloys, the
cylinders for overcasting with pre-
fabricated bases in gold are to be
the first choice for the construction of
prosthetic infrastructures on dental
implants. Of all of the existing metallic
alloys for the manufacture of dental
prosthesis, none were better than
the gold alloys in relation to intraoral
survival time due to their following
characteristics:
• Excellent biocompatibility: no
cytotoxic potential (extraction test ISO
10993-5) or allergenic reaction (ISO
10993-10 maximized);
• Extremely low levels of corrosion
(according to regulation ISO/DIS
10271);
• Excellent mechanical properties;
• Reduction of friction coefficient
between parts;
• Increased pre-load of the prosthetic
screw.
From a technical point of view, this
is an alloy of easy handling for the
DENTAL TECHNICIAN, since it has an
optimal hardness, low capacity for
deformation and a white colouring,
which makes aesthetics easier. Its
high fusion temperature permits
overcasting with gold and semi-gold
alloys and results in complete safety
for the ceramic application.
Cylinders on mini abutments and
UCLAs are available in this alloy. Note
the sequence
of this product found in this catalogue.
Important informations:
• Melting range: 1.400 to 1490°C
(2.552 to 2.714 °F);
• Density: 17,5 g/cm3;• Coefficient of thermal expansion:
12,2µm/K (600°C).
The alloys must be chosen to be
compatible with the overcasting
procedure (gold or semigold) that
are in accordance with regulation ISO
9693 and ISO 22674..
The thickness of the metal after
overcastting should be at least 0.5
mm.
Welding must be done in the range of
800 to 890°C (1.472 to 1.634 °F).
The gold alloy with a high melting has the following chemical composition:
CHEMICAL ELEMENT Composition (%)
Gold 60
Palladium 20
Platinum 19
Iridium 1
24
CASTABLE LINE
A product line that gives to the
DENTAL TECHNICIANS complete
freedom to cast the infrastructure
with a metallic alloy of their choice,
directly over the implant platform or
abutment. Often, price is the decisive
factor in this choice. Therefore, the
adaptation quality to the implant
primarily depends on the care
in handling by the professional,
providing quality assurance of
prosthetic components with pre-
fabricated metallic base.
After casting, we suggest that you
always evaluate the adaptation of
the analogues prior to cementing the
crown.
The castable components are
available for all cylinders on
intermediary, Universal Posts and
UCLAs. Note the sequence of this
product found in this catalogue.
25
TITANIUM LINE
Among the more traditional alloy in
implantology, there is the Titanium,
conforming to regulation ASTM F136-
Ti6Al4V. Known as Titanium grade V,
it is widely used in the manufacture of
provisional prosthesis. The dentist or the
DPT can adapt resin crowns pre-fabricated
over the cylinders and can create
provisional crowns with perfect fitting
and security, or even create a provisional
crown directly over the cylinders, which
can be used in immediate loading
situations. The prosthetic components
in Titanium are provided sterile,
guaranteeing security and strengthening
our ethical commitment with you..
Pre-fabricated components in Titanium
must not be overcasted. Although
Titanium has a high fusion temperature
(approx 1680 ºC), the alloy undergoes
structural changes when subjected to high
temperatures. Therefore, metallic alloys
with Titanium base still remain a challenge
to the science of dental material.
The Titanium prosthetic components are
offered as cylinders for all intermediates
and implants, also as customized
infrastructures with the Neoshape line.
Note the mechanical characteristics
(rotational or anti-rotational) of each case
and the sequence of products found in this
catalogue.
2626
The implant with impermeable fitting that optimizes bacterial sealing and the health of peri-implant tissue.
•CM Abutment (single)•CM Mini Abutment
(multiple)•CM Angled Mini
Abutment 17° and 30° (multiple)
•CM Micro Abutment (multiple)
•CM Angled Universal Post 17° and 30°
•CM Universal Post Through Screw
•CM Universal Post (single body)
•Anatomical Post in Titanium
•CM Mini Ball Attachment •CM Micro Abutment•CM Mini Abutment•CM Angled Mini Conical
Abutment 17° and 30°•Cylinder and Distal Bar
Passive Fitting Technique•Castable Cylinder – Mini Abutment •Titanium Cylinder – Mini Abutment •Brass Cylinder – Mini Abutment
•WS Abutment (single)•Ws Mini Abutment
(multiple)•CM Transepithelial
Abutment (multiple)
•WS Universal Post with Through Screw •WS Mini Abutment (single)
Passive Fitting Technique•Castable Cylinder – Mini
Abutment •Titanium Cylinder – Mini
Abutment •Brass Cylinder – Mini Abutment
MORSE TAPER
MORSE TAPER WSZYGOMATIC CM
3.5, 3.75, 4.0, 4.3 and 5.0 mm
4.0, 5.0 and 6.0 mm
Screw-retained Prosthesis
Cemented Prosthesis Overdenture Protocol
Ø 2.5 mm
Ø 3.0 mm
Ø Implant
Ø Implant
MORSE TAPER
COMPONENTS INDICATION TABLE
Inte
rna
l Thre
ad
Ø 1
.8In
tern
al T
hrea
d Ø
1.8
2727
M o r s e T a p e r
• GAP reduced (impermeable fitting);
• Stable Anti-rotational fixing;
• High mechanical strength;
• Unique prosthetic interface, independent of the implant diameter;
• First system with Morse Taper fitting in Brazil;
• The CM angle and the internal thickness of the implant enable the
design of the screw thread to reach the cervical portion of the
implant;
• High resistance, comparable to implants with external hex with
regular platform;
•NeoPoros Surface.
Simplified installation with no mount.
Morse Taper Implants now with indexer.
New line of Exact components, specific for
CM Index Implants.
Each point at Installation Driver corresponds to one plane face of the indexer.
28
The hexagonal prosthetic index simplifies the
implant installation process, reduces surgical
time, increases the resistance to insertion torque
and allows dentists to install the prosthesis
already with a forecast for the positioning of
the crown regarding the implant, thus providing
even more safety, speed and flexibility to clinical
and laboratorial works.
CM Implantsnow with Prosthetic Index
The hexagonal prosthetic index simplifies the
implant installation process, reduces surgical
time, increases the resistance to insertion torque
and allows dentists to install the prosthesis
already with a forecast for the positioning of
the crown regarding the implant, thus providing
even more safety, speed and flexibility to clinical
and laboratorial works.
Capture and Transport of the Implant
Specific drivers to the hexagonal prosthetic
indexer in the implant, available for contra-
angle or ratchet, allow the capture of the
implants directly on the package.
The replacement of old mounts for these drivers
guarantees greater resistance to torque, more
faster and safety on procedures.
Drivers
The installation drivers have six markings
which match with the six faces of the hexagonal
prosthetic index of implant. At the installation
moment, one of these markings in driver should
be in vestibular position, facilitating thus the
posterior prosthetic procedure.
29
CM ExactLine
Versatility of Index Implant
The CM implants with prosthetic index remain
compatible with the entire line of CM prosthetic
components that you already know. However, the
Exact line is only compatible with CM implants
with Index.
Contact one of our consultants and discover the
advantages of the new Morse Taper implants and
whole family of Exact prosthetic components.
Versatility of Index Implant
Apart from the single CM interface for all implant diameters, the CM implants now have one more family of prosthetic components, the EXACT LINE. This line features have at their tip a hex index that allows positioning the prosthesis over the implant (prosthetic indexing), making our Morse Tapers line even more flexible.
CM Index Implants
Conventional
components or Exact
Only Conventional
Components
CM Implant CM Index Implants CM Implant
30
3.5mm
4.3mm
5.0mm
Init
ial
Dri
ll
Alv
im D
rill
2.0
Alv
im D
rill
3.5
Alv
im D
rill
4.3
Alv
im D
rill
5.0
Drill sequence
Launch
Product Characteristics:
•Morse Taper interface;
•NeoPoros Surface;
•Implant with conical central nucleus;
•Cervical conicity to reduce the compressive tension;
•Double and progressive threads;
•Cutting chambers in counterclockwise direction;
•Apical thread with blade shape;
•The installation is performed with specific drivers to the index
of the implant, providing the implant capture directly on
packaging, offering more safety and speed;
•Suitable for bones type III and IV and pos-extracting
installation;
•Unique prosthetic interface for all implant diameters;
•Best prosthetic resolution with CM Implant 2mm infraosseous;
•Perforation rotation: 500-800 rpm;
•Insertion rotation: 30 rpm.
31
Ø 3.3
Ø 4.5
5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm
106.182 106.168 106.169 106.170 106.183 106.184
106.175 106.171 106.172 106.173 106.174 106.180
8.0 mm 10.0 mm 11.5 mm 13.0 mm 16.0 mm
Ø 3.5
Ø 4.3
Ø 5.0
109.692 109.682 109.693 109.683 109.684
109.689 109.688 109.627 109.628 109.629
109.690 109.685 109.691 109.686 109.687
CM Cover Screw
117.013 117.017
2 mm
•Use Digital Driver 1.2mm (104.007) for installation;
•Do not exceed torque of 10 N.cm.
•Use Digital Driver 1.2mm (104.007) for
installation;
•Do not exceed torque of 10 N.cm.
Healings
M o r s e T a p e r
32
3.5mm
3.75mm
4.0mm
Init
ial
Dri
ll
Tit
am
ax
Dri
ll 2
.0
Pil
ot
2/3
Tit
am
ax
Dri
ll 2
.8
Tit
am
ax
Dri
ll 3
.0
CM
Pil
ot
2.8
/3.5
Tit
am
ax
Dri
ll 3
.15
Tit
am
ax
Dri
ll 3
.3
5.0mm
CM
Pil
ot
3/3
.75
CM
Pil
ot
3.3
/4.0
Tit
am
ax
Dri
ll 3
.8
Tit
am
ax
Dri
ll 4
.3
CM
Pil
ot
4.3
/5.0
Drill sequence
Optional
•Cylindrical implant with Morse Taper interface;
•NeoPoros Surface;
•The installation is performed with specific drivers to the index
of the implant, providing the implant capture directly on
packaging, offering more safety and speed;
•Double thread (faster installation and less trauma);
•High cutting capacity;
•Suitable for bones type I and II and grafting areas in block;
•Cover screw not included;
•Unique prosthetic interface for all implant diameters;
•Cervical diameter equal to implant diameter;
•Observe the specific Pilot Drill (countersink function);
•Better prosthetic resolution with CM Implant inserted 2mm
infraosseous;
•Perforation rotation: 800-1200 rpm;
•Insertion rotation: 30 rpm.
Product Characteristics:
33
Ø 5.0
Ø 4.0
7.0 mm 8.0 mm 9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm
109.613 109.614 109.615 109.616 109.617 109.618 109.619
109.606
109.642
109.607
109.643
109.608
109.644
109.609
109.645
109.610
109.646
109.611 109.612
109.630 109.631 109.632 109.633 109.620 109.634 109.635
Ø 3.5
Ø 3.75
CM Cover Screw
117.013 117.017
2 mm
•Use Digital Driver 1.2mm (104.007) for
installation;
•Do not exceed torque of 10 N.cm.
•Use Digital Driver 1.2mm (104.007) for installation;
•Do not exceed torque of 10 N.cm.
Healings
Ø 3.3
Ø 4.5
5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm
106.182 106.168 106.169 106.170 106.183 106.184
106.175 106.171 106.172 106.173 106.174 106.180
M o r s e T a p e r
34
•Cylindrical implant with Morse Taper interface;
•NeoPoros Surface;
•The installation is performed with specific drivers to the index of
the implant, providing the implant capture directly on packaging,
offering more safety and speed;
•Double thread (faster installation and less trauma);
•High compaction capacity (bone expansion);
•Suitable for bones type III and IV and in areas with little bone
thickness;
•Cover screw not included;
•Unique prosthetic interface for all implant diameters;
•Cervical diameter equal to implant diameter;
•Simplified instrumentation in the prepare of surgical alveolus;
•Best prosthetic resolution with CM Implant 2mm infraosseous;
•Perforation rotation: 800-1200 rpm;
•Insertion rotation: 30 rpm.
Product Characteristics:
•Cylindrical implant with Morse Taper interface;
•NeoPoros Surface;
•The installation is performed with specific drivers to the index of
the implant, providing the implant capture directly on packaging,
offering more safety and speed;
•Double thread (faster installation and less trauma);
•High compaction capacity (bone expansion);
•Suitable for bones type III and IV and in areas with little bone
thickness;
•Cover screw not included;
•Unique prosthetic interface for all implant diameters;
•Cervical diameter equal to implant diameter;
•Simplified instrumentation in the prepare of surgical alveolus;
•Best prosthetic resolution with CM Implant 2mm infraosseous;
•Perforation rotation: 800-1200 rpm;
•Insertion rotation: 30 rpm.
Product Characteristics:
Optional
3.5mm
3.75mm
4.0mm
Init
ial
Dri
ll
Tit
am
ax
Dri
ll 2
.0
Pil
ot
2/3
Tit
am
ax
Dri
ll 2
.8
Tit
am
ax
Dri
ll 3
.0
Drill sequence
Morse Taper
35
Ø 4.0
9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm
Ø 3.5
Ø 3.75
109.661 109.662 109.663 109.664 109.665
109.666 109.667 109.668 109.669 109.670
109.636 109.637 109.638 109.639 109.640
M o r s e T a p e r
CM Cover Screw
117.013 117.017
2 mm
•Use Digital Driver 1.2mm (104.007) for
installation;
•Do not exceed torque of 10 N.cm.
Healings
Ø 3.3
Ø 4.5
5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm
106.182 106.168 106.169 106.170 106.183 106.184
106.175 106.171 106.172 106.173 106.174 106.180
•Use Digital Driver 1.2mm (104.007) for installation;
•Do not exceed torque of 10 N.cm.
36
3.5mm
4.3mm
5.0mm
Init
ial
Dri
ll
Alv
im D
rill
2.0
Alv
im D
rill
3.5
CM
Pil
ot
2.8
/3.5
Alv
im D
rill
4.3
CM
Pil
ot
3.6
/4.3
Alv
im D
rill
5.0
CM
Pil
ot
4.3
/5.0
Drill Sequence
Product Characteristics:
• Conical implant with Morse Taper interface;
• NeoPoros Surface;
• The installation is performed with specific drivers to the
index of the implant, providing the implant capture directly
on packaging, offering more safety and speed;
• Double thread (faster installation and less trauma);
• Suitable for bones type III and IV and pos-extracting
installation;
• Cover screw not included;
• Cervical diameter equal to implant diameter;
• Unique prosthetic interface for all implant diameters;
• Observe the specific Pilot Drill (function countersink);
• Best prosthetic resolution with CM Implant 2mm
infraosseous;
• Perforation rotation: 500-800 rpm;
• Insertion rotation: 30 rpm.
37
8.0 mm 10.0 mm 11.5 mm 13.0 mm 16.0 mm
Ø 3.5
Ø 4.3
Ø 5.0
109.657 109.658 109.659 109.621 109.660
109.647 109.648 109.649 109.622 109.651
109.652 109.653 109.654 109.655 109.656
M o r s e T a p e r
CM Cover Screw
117.013 117.017
2 mm
•Use Digital Driver 1.2mm
(104.007) for installation;
•Do not exceed torque of 10 N.cm.
Healings
Ø 3.3
Ø 4.5
5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm
106.182 106.168 106.169 106.170 106.183 106.184
106.175 106.171 106.172 106.173 106.174 106.180
•Use Digital Driver 1.2mm (104.007) for installation;
•Do not exceed torque of 10 N.cm.
38
Obligatory for Cortical Implant and Optional for CM Medullar Implant
•Cylindrical implant with Morse Taper interface;
•NeoPoros Surface;
•Pre-mounted;
•Cover screw not included;
•Optimization of primary stability;
•Excellent alternative to posterior edentulous lower jaw;
•Specific Surgical Kit;
•Observe the specific Pilot Drill (same function of
countersink drill);
•In Medullar Titamax WS Implant, the pilot drill is optional;
•Perforation rotation: 200-300 rpm;
•Insertion rotation: 30 rpm;
•Unique Morse Taper prosthetic interface (same
dimensions as CM Zygomatic Implants).
Product Characteristics:
•Cylindrical implant with Morse Taper interface;
•NeoPoros Surface;
•Pre-mounted;
•Cover screw not included;
•Optimization of primary stability;
•Excellent alternative to posterior edentulous lower jaw;
•Specific Surgical Kit;
•Observe the specific Pilot Drill (same function of
Product Characteristics:
countersink drill);
•In Medullar Titamax WS Implant, the pilot drill is optional;
•Perforation rotation: 200-300 rpm;
•Insertion rotation: 30 rpm;
•Unique Morse Taper prosthetic interface (same
dimensions as CM Zygomatic Implants).
•Pre-mounted;
•Cover screw not included;
•Optimization of primary stability;
•Excellent alternative to posterior edentulous lower jaw;
•Specific Surgical Kit;
•Observe the specific Pilot Drill (same function of
4.0mm
5.0mm
6.0mm
Init
ial
Dri
ll
Tit
am
ax
Dri
ll 2
.0
Pil
ot
2/3
Tit
am
ax
Dri
ll 2
.8
Tit
am
ax
Dri
ll 3
.0
CM
Pil
ot
2.8
/3.5
Tit
am
ax
Dri
ll 3
.3
CM
Pil
ot
3/3
.75
CM
Pil
ot
3.3
/4.0
Tit
am
ax
Dri
ll 3
.8
Tit
am
ax
Dri
ll 4
.3
CM
Pil
ot
3.8
/4.3
Tit
am
ax
Dri
ll 5
.3
CM
Pil
ot
4.3
/5.0
CM
Pil
ot
4.3
/5.3
CM
Pil
ot
5.3
/6.0
Drill sequence
Morse Taper
Medullar and Cortical
39
Cortical Medullar
5.0 mm 6.0 mm
Ø 4.0
Ø 5.0
Ø 6.0
109.604
109.574
109.605
109.575
109.576 109.577
WS Cover Screw
117.016
3.5 mm2.5 mm1.5 mm0.8 mm
106.186 106.187 106.188 106.189
5.0 mm 6.0 mm
Ø 5.0
Ø 6.0
109.578 109.579
109.580 109.581
•Use Digital Driver 1.2mm (104.007)
for installation;
•Do not exceed torque of 10 N.cm.
WS Healings
M o r s e T a p e r
•Use Digital Driver 1.2mm (104.007) for installation;
•Do not exceed torque of 10 N.cm.
4040
Demonstrative sequence of
CM Abutment and WS Abutment
CM Abutment WS Abutment
Torque Connection 1.6
Prosthetic Torque Ratchet Driver
Transfer GT Open Tray
Transfer
Transfer GT Closed Tray
Transfer
GT Analogue
GT Protective Cylinder
GT Cylinder
Co
Cr
Tit
an
ium
Ca
sta
ble
Torque Connection 1.2
Prosthetic Torque Ratchet Driver
32N.cm
•Same prosthetic sequence as the GT Implant;
•Available in Titanium;
•Minimum interocclusal space of 5.0mm from the
mucosa level;
•Conicity 15°;
•Single screw-retained prosthesis (anti-rotational);
•The cylinders come with Neotorque screw, except
the castables, that comes with Titanium screw.
41
106.102
GT ProtectiveCylinder
108.039
OpenTray
ClosedTray
108.040
101.037
GT Analogue
GT CylinderScrew
Titanium Neotorque
116.038 116.228
Castable
Titanium
CoCr
GT Transfer GT Cylinder
118.180
118.179
118.242
• Observe corresponding sequence and indicated torque;
• Use Torque Connection 1.6mm (105.006);• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
•Available: Titanium: for provisional prosthesis; CoCr: overcastting; Castable: casting.•With screw;•To screw torque, use Torque Connection 1.2mm (105.005);
•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);
•Anti-rotational.
•Available in Titanium;•Replica of implant platform or prosthetic component;
•For prosthesis construction or prosthetic planning.
•Available in Titanium;•Used to protect the component during the prosthesis construction;
•To installation, use Digital Driver 1.2mm (104.007).
•Available in Titanium;•For transference and molding of prosthesis;
•For open tray or closed tray technique;
•Anti-rotational.
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm
115.162 115.147 115.148 115.152 115.163 115.164
CM Abutment
0.8 mm 1.5 mm 2.5 mm 3.5 mm
WS Abutment
115.180 115.181 115.182 115.183
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
M o r s e T a p e r
42
WS MiniConical Abutment
CM MiniConical Abutment
CM Angled MiniConical Abutment
and EXACT(170 and 300)
ProstheticAbutment Driver
ProstheticAbutment Driver
TorqueConnection 0.9mm
Transfer Mini Conical Abutment
Transfer Mini Conical Abutment
Multifuncional
Analogue Mini Conical Abutment
Protective Cylinder of Mini Conical Abutment
Cylinder of Mini Conical Abutment
No
ble
/ C
oC
r
Tit
an
ium
Ca
sta
ble
Torque Connection 1.2
Prosthetic Torque Ratchet Driver
Prosthetic Torque Ratchet Driver
32N.cm
32N.cm
15N.cm
42
Demonstrative sequence
CM Mini Abutment and WSCM Angled Mini Abutment
•Available in Titanium;
•Minimum interocclusal space of 4.4mm from the
mucosa level;
•Multiple and screw-retained prosthesis;
•Conicality 20°;
•The cylinders come with Neotorque screw, except
the castables, that comes with Titanium screw.
43
115.154
115.176
115.149
115.177
115.166170
115.169300
115.150
115.178
115.167
115.170
115.151
115.179
115.168
115.171
115.153 115.160
Analogue of MiniConical Abutment
Castable Titanium Noble CoCr CoCrfor welding
116.036
116.227116.037
0.8 mm
0.8 mm
1.5 mm
1.5 mm
1.5 mm
2.5 mm
2.5 mm
2.5 mm
3.5 mm
3.5 mm
3.5 mm
4.5 mm 5.5 mm
CM Mini Conical Abutment
WS MiniConical Abutment
CM AngledMini Conical Abutment
•Observe sequence and indicated torque;•To component torque, use Prosthetic Abutment Driver (105.009);•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
• Height of CM angled prosthetic components available on page 54;• To component torque, use Torque Connection 0.9 (105.065).
CylinderMini Conical Abutment
•Available in: Titanium: provisional prosthesis; CoCr: overcastting; Castable: casting; Gold: gold alloy with high melting range.•With screw;•To screw torque, use Torque Connection 1.2mm (105.005)•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Rotational for screw-retained multiple elements.
118.112Ø 4.1
Ø 4.1
Ø 4.1
Ø 4.1
Ø 4.1
118.113 118.206 118.209 118.210
106.054
Protective Cylinder ofMini Conical Abutment
108.022 108.068
101.020
Transfer of MiniConical Abutment
OpenTray
Short Screw
Multifunctional
Cylinder Screw
Titanium Neotorque•Available in Titanium;•Replica of prosthetic component;•For prosthesis construction or prosthetic planning.
•Available in Titanium;•Used to protect the component during the prosthesis construction;•To installation, use Digital Driver 1.2mm (104.007).
•Available in Titanium;•Component with molding function by prosthesis construction;•For open tray or closed tray technique;•Rotational.
108.021
ClosedTray
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
M o r s e T a p e r
44
Cylinder of Micro Abutment
Co
Cr
Ca
sta
ble
Tit
an
ium
CM Micro Abutment
Prosthetic Abutment Driver
Prosthetic Torque
Ratchet Driver
Transfer CM Micro Abutment Open tray
Analogue of Micro Abutment
Protective Cylinder of Micro Abutment
Torque Connection 1.2
Prosthetic TorqueRatchet Driver
32N.cm
44
Demonstrative sequence of
CM Micro Abutment
•Available in Titanium;
•Multiple and screw-retained prosthesis;
•Indicated to CM Implants with diameter of 3.5mm
and close to each other;
•Minimum interocclusal space of 4.4mm from the
mucosa level;
•Prosthetic fitting diameter of 3.3mm ;
•The cylinders come with Neotorque screw, except
the castables, that comes with Titanium screw.
3.5
45
Transfer ofCM Micro Abutment
118.246
Titanium
118.245 118.247
CoCr Castable
115.200 115.201 115.202
1.5 mm 2.5 mm 3.5 mm
CM MicroAbutment
•Observe sequence and indicated torque;•To component torque, use Prosthetic Abutment Driver (105.009);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Cylinder of CM Micro Abutment
•Available in: Titanium: provisional prosthesis; CoCr: overcastting; Castable: casting.•With screw;•To screw torque, use Torque Connection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Rotational for screw-retained multiple elements.
116.227116.037
106.199
Protective Cylinder ofCM Micro Abutment
CylinderScrew
Titanium Neotorque
•Available in Titanium;•Used to protect the component during the prosthesis construction;
•To installation, use Digital Driver 1.2mm (104.007).
Analogue ofCM Micro Abutment
108.070
101.057
Rotational
•Available in Titanium;•Replica of prosthetic component;
•For prosthesis construction or prosthetic planning.
•Available in Titanium;•Component with molding function by prosthesis construction;•For open tray technique;•Rotational.
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
M o r s e T a p e r
46
Transfer of CM Exact Implant Closed tray
Transfer of CM Exact Implant Closed tray
Transfer of CM Exact Implant Open
tray
CM Implant Analogue
Torque Connection 0.9mm
Prosthetic TorqueRatchet Driver
Optional sequenceIndicated sequence
CM Anatomic Post
Customization if is necessary
Conventional molding
Laboratorial Phase
Laboratorial Phase
Prosthesis conclusion
Torque Connection 0,9mm
Prosthetic TorqueRatchet Driver
CM Anatomic Post
15N.cm
15N.cm
46
Demonstrative sequence of
CM and Exact Anatomic Post
•Available in Titanium;
•Cemented unitary prosthesis;
•Possible customization;
•Indicated for aesthetic area;
•Height of anatomic prosthetic
components available on page 55.
maximum
47
1.5 mm
1.5 mm
2.5 mm
2.5 mm
3.5 mm
3.5 mm
Lateral CMAnatomic Post
Lateral ExactCM Anatomic Post
114.419 114.420 114.421
CM Implant Transfer
•Available in Titanium;•Component with molding function for the prosthesis confection;
•For open tray and closed tray technique;•Length: - Short: 15 mm; - Conventional: 20 mm.
CM ImplantAnalogue
101.058
•Available in Titanium;•Replica of the implant;•To the prosthesis confection or prosthetic planning.
1.5 mm
1.5 mm
2.5 mm
2.5 mm
3.5 mm
3.5 mm
CM AnatomicPost
Exact CMAnatomic Post
•Available in Titanium;•Cemented prosthesis;•To installation, use Torque Connection 0,9mm (105.065);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
•Available in Titanium;•Cemented prosthesis;•To installation, use Torque Connection 0,9mm (105.065);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Exact component exclusive for CM Index implants.
114.328
114.422 114.425
114.329
114.423 114.426
114.330
114.424 114.427
108.069
Short
Exact
Conventional
Opentray
108.065
108.041
108.076
Closed tray
M o r s e T a p e r
48
Prosthetic Torque
Ratchet Driver
Transfer of CM Post
Analogue of
CM Post
Cylinder of Universal Post
Ø 3.3
Ø 3.3
Ø 3.3
Ø 4.5
Ø 4.5
Ø 4.5
Alu
min
a
Alu
min
a
Pro
vis
ion
al
Pro
vis
ion
al
Ca
sta
ble
Ca
sta
ble
32N.cm
CM Universal Post
Torque Connection 1.2 mm
48
Demonstrative sequence of
CM Universal Post
•Available in Titanium;
•Cemented single prosthesis;
•Straight component with single body.
49
114.129 114.077 114.078 114.079 114.136 114.137
114.130 114.086 114.087 114.088 114.139 114.140
114.131 114.080 114.081 114.082 114.142 114.143
114.132 114.083 114.084 114.085 114.145 114.146
UniversalPost Transfer
UniversalPost Set
UniversalPost Analogue
118.186
108.042
108.060101.038
118.181 118.192
118.188
108.044
108.062101.040
118.183 118.194
118.187
108.043
108.061101.039
118.182 118.193
118.189
108.045
108.063101.041
118.184 118.195
ProvisionalAlumina Castable
UniversalPost Cylinder
0.8 mm
Ø 3.3
Ø 3.3
Ø 3.3
Ø 3.3 Ø 3.3
Ø 3.3
Ø 3.3
Ø 3.3 Ø 3.3
Ø 3.3
Ø 4.5
Ø 4.5
Ø 4.5
Ø 4.5Ø 4.5
Ø 4.5
Ø 4.5
Ø 4.5Ø 4.5
Ø 4.5
4 m
m
4 m
m
4 m
m4
mm
4 m
m6
mm
6 m
m6
mm
6 m
m
6 m
m
1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm
CM Universal Post
•To installation, use Torque Connection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
• Available in: Acrylic: provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting.• Compatible with all Universal Posts, if not prepared.
•Available in polymer;•Component with molding function by prosthesis construction;
•For closed tray technique;•Select transfer according to the component to be molded, as prosthetic planning;
•Anti-rotational.
• Available in Titanium;• Replica of prosthetic component platform;
• For prosthesis construction and prosthetic planning.
•Components Kit of Universal Post line, containing Transfer and Provisional / Castable Cylinders.
M o r s e T a p e r
50
WS ImplantTransfer
Closed tray
CM Implant
Analogue
WS Implant
Analogue
Torque Connection 0.9mm
Torque Connection 1.2mm
Prosthetic Torque
Ratchet Driver
WS Post
Laboratorial PhaseLaboratorial Phase
CM ImplantTransfer
Closed tray
CM ImplantTransfer
Open tray
Transfer of ExactCM ImplantClosed tray
32N.cm
15N.cm
CM UniversalPost Through
Screw
Exact CMUniversal Post
50
Demonstrative sequence of
CM Universal Post Through Screw Exact CM Universal PostWS Universal Post
•Available in Titanium;
•Cemented single prosthesis;
•Indicated for laboratorial customization.
Prosthesis concludedProsthesis concluded
maximum
51
WS Universal Post
114.183 114.184 114.185 114.186
114.187 114.188 114.189 114.190
0.8 mm
Ø 4.5 4 m
m6
mm
1.5 mm 2.5 mm 3.5 mm
•In two pieces (body and screw);•To installation, use Torque Connection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
101.058 101.055
CM WS
Analogue
•Available in Titanium;•Replica of prosthetic component platform;
•For prosthesis construction and prosthetic planning.
114.148 114.149 114.150 114.151 114.152 114.153
114.155 114.156 114.157 114.158 114.159 114.160
114.115 114.117 114.118 114.119 114.162 114.163
114.116 114.120 114.121 114.122 114.165 114.166
CM UniversalPost Through Screw
0.8 mm
Ø 3.3
Ø 3.3
Ø 4.5
Ø 4.5
4 m
m6
mm
1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm
•To installation, use Torque Connection 0.9mm (105.065);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
114.408 114.360 114.361 114.362 114.363 114.364
114.409 114.366 114.367 114.368 114.369 114.370
114.410 114.357 114.358 114.359 114.372 114.373
114.411 114.340 114.341 114.342 114.375 114.376
Exact CMUniversal Post
0.8 mm
Ø 3.3
Ø 3.3
Ø 4.5
Ø 4.5
4 m
m6
mm
1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm
•Component with through screw;•To installation, use Torque Connection 0.9mm (105.065);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Component Exact exclusive for CM Implant Index.
M o r s e T a p e r
CM Implant Transfer
•Available in Titanium;•Component with molding function for the prosthesis confection;
•For open tray and closed tray technique;•Length: - Short: 15 mm; - Conventional: 20 mm
108.069
Short
Exact
WS
Conventional
Opentray
108.065
108.041
108.076
108.064
Closed tray
52
Prosthetic Torque
Ratchet Driver
CM AngledUniversal Post
Exact CMAngled Universal
Post
Torque
Connection 0.9mm
15N.cm
CM Post Transfer
CM Post
Analogue
Universal Post
Cylinder
Ø 3.3
Ø 3.3
Ø 3.3
Ø 4.5
Ø 4.5
Ø 4.5
Alu
min
a
Alu
min
a
Pro
vis
ion
al
Pro
vis
ion
al
Ca
sta
ble
Ca
sta
ble
52
Demonstrative sequence of
Universal PostAngled CM and Exact
•Available in Titanium;
•Cemented single prosthesis.
53
Ø 3.3
Ø 3.3
Ø 3.3
Ø 3.3
Ø 4.5
Ø 4.5
Ø 4.5
Ø 4.5
4 m
m4
mm
6 m
m6
mm
1.5 mm 2.5 mm 3.5 mm
Exact CMAngled Universal Post
114.390
114.396
114.402 114.403 114.404
114.405 114.406 114.407
114.397 114.398
114.399 114.400 114.401
114.391 114.392
114.393 114.394 114.395
114.384 114.385 114.386
114.387 114.388 114.389
170 170
300 300
•Component with through screw;•To installation, use Torque Connection 0.9mm (105.065);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Height of CM angled prosthetic components available on page 54;•Exact component exclusive for CM Index implant.
Universal PostTransfer
UniversalPost Set
UniversalPost Analogue
108.042
108.060101.038
108.044
108.062101.040
108.043
108.061101.039
108.045
108.063101.041
Ø 3.3
Ø 3.3 Ø 3.3
Ø 3.3
Ø 3.3Ø 3.3
Ø 4.5
Ø 4.5Ø 4.5
Ø 4.5
Ø 4.5Ø 4.5
4 m
m4
mm
4 m
m
6 m
m6
mm
6 m
m
•Available in polymer;•Component with molding fuction to the prosthesis confection;
•For closed tray technique;•Select Transfer according to the component to be molded as prosthetic planning;
•Anti-rotational.
•Available in Titanium;•Replica of prosthetic component platform;
•For prosthesis construction and prosthetic planning.
•Components Kit of Universal Post line, containing Transfer and Provisional / Castable Cylinders.
Ø 3.3
Ø 3.3
Ø 3.3
Ø 3.3
Ø 4.5
Ø 4.5
Ø 4.5
Ø 4.5
4 m
m4
mm
6 m
m6
mm
1.5 mm 2.5 mm 3.5 mm
CM AngledUniversal Post
114.095
114.101
114.107 114.108 114.109
114.110 114.111 114.112
114.102 114.103
114.104 114.105 114.106
114.096 114.097
114.098 114.099 114.100
114.089 114.090 114.091
114.092 114.093 114.094
M o r s e T a p e r
118.186 118.181 118.192
118.188 118.183 118.194
118.187 118.182 118.193
118.189 118.184 118.195
ProvisionalAlumina Castable
UniversalPost Cylinder
Ø 3.3
Ø 3.3
Ø 4.5
Ø 4.5
4 m
m6
mm
•Available in: Acrylic: provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting.•Compatible with all Universal Posts, if not prepared.
54
Angled Universal Post
Ø 4.5Ø 3.3
Angled Mini Conical Abutment
300
170
300170
5.8
0
4.5
05
.20
4.9
0
4.8
0
3.5
04
.20
3.9
0
3.8
0
2.5
03
.20
2.9
0
3.5
0
3.5
03
.50
3.5
0
4.9
0
3.5
0
5.9
0
3.5
0
2.5
0
2.5
02
.50
2.5
0
3.9
0
2.5
0 4.9
0
2.5
0
1.5
0
1.5
01.
50
1.5
0
2.9
0
1.5
0 3.9
0
1.5
0
54
Height of CM AngledProsthetic Components
55
CM Anatomic Post
CM Lateral Anatomic Post
8 m
m6 m
mT
ran
smu
co
sal
Tra
nsm
uc
osa
l
5 mm6 mm
6.5
mm
5.3
mm
Tra
nsm
uc
osa
l
Tra
nsm
uc
osa
l
4.3 mm4.7 mm
55
Height of Anatomic Post andLateral Anatomic Post
56
CM Mini Ball
Attachment
Prosthetic Abutment Driver
Prosthetic Torque Ratchet Driver
Straight
positioner
Positioner
70
Positioner
140
O’ring with Cylinder
Disk
32N.cm
Protection Disk Positioner
56
Demonstrative sequence of
CM Mini Ball Attachment
•Available in Titanium;
•Application of Nitride Titanium coating for increased the
wear resistance;
•Directly over the implant;
•For Overdenture prosthesis, its function is the O’ring
retention;
•It’s recommended capture the components in patient’s
mouth, one by one;
•Obligatory to use positioner for capture;
•O’ring with protection disc;
•See the demonstrative sequence of Mini Ball Attachment
on page 126.
57
M o r s e T a p e r
CastableBall Attachment
102.069 102.070 102.071 102.097
CM Mini BallAttachment
1.5 mm 2.5 mm 3.5 mm 4.5 mm
•Select according to the mucosa height;•To installation, use Prosthetic Abutment Driver (105.009);•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
•Casting in various metals;•May be cemented in natural roots or waxed in bars for overdenture retention.
102.078
straight, 70 and 140
Positioners
•Available in polymer;•Indicated to define the correct distance between Attachment Ball components and O’ring with cylinder;•Corrects the parallelism between the implants;•Essential for O’ring capturing.
102.076
102.073
102.077
O’ring with Cylinder
Mini O’ring
Protection Disk
102.075
O’ringRemover
O’ringMount
104.044
104.043
•Digital Driver with function of O’ring replacing to the cylinder.
•Digital Driver with function of O’ring replacing to the cylinder.
•Available in Titanium (cylinder);•Available in polymer (O’ring);•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
•Protection disk included;•Not autoclavable.
•Available in polymer;•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
•Not Autoclavable.
•Package with 10 units.
58
• Ensures the integrity of external hexagon;
• Maintains original rotational freedom;
• More practicality and safety;
• Increased mechanical strength to the insertion;
• Transport tweezers to the safety in handling the implant.
The solution to the limitations of conventional external hexagon.
Area of Internal torque. Tweezers that ensures increased safety in the
implant transport.
59
Hex 2
.37 m
m
Ø4.1 mm
Ø3.3 mm
1 mm
0.7 mm
Hex 3.3 mm
Ø 5.0 mm
Hex 2.7 mm
Hex 2.7 mm
Ø 3.3
Ø 4.1
Ø 4.3
Ø 5.0
•Castable UCLA •CoCr UCLA
•SF Mini Conical Abutment (multiple)
•Angled Mini Conical Abutment 17°and 30° (multiple)
•SF Conical Abutment (single)
•Castable UCLA •Noble UCLA •CoCr UCLA
•Mini Conical Abutment (multiple)
•Angled Mini Conical Abutment 17°and 30° (multiple)
•Conical Abutment (single)
•Castable UCLA •CoCr UCLA
•SF Mini Conical Abutment (multiple)
•Angled Mini Conical Abutment 17° and 30° (multiple)
•SF Conical Abutment (1 piece)
•Castable UCLA •CoCr UCLA
•Angled Post 17° •Universal Post •Castable UCLA •Titanium UCLA •CoCr UCLA
•Mini Ball Attachment
•Angled Post 17° and 30° •Universal Post •Customizable Post •Castable UCLA •Noble UCLA •Titanium UCLA •CoCr UCLA
•Mini Ball Attachment •Mini Conical Abutment •Angled Mini Conical
Abutment 17°and 30° •Cylinder and Distal
External Bar
Passive Fitting Technique•Castable Cylinder of Mini
Abutment •Titanium Cylinder of Mini
Abutment •Brass Cylinder of Mini
Abutment
•Mini Conical Abutment •Angled Mini Conical
Abutment 17°and 30° •Cylinder and Distal
External Bar
Passive Fitting Technique•Castable Cylinder of Mini
Abutment •Titanium Cylinder of Mini
Abutment •Brass Cylinder of Mini
Abutment
•Mini Conical Abutment •Angled Mini Conical
Abutment 17°and 30° •Cylinder and Distal
External Bar
Passive Fitting Technique•Castable Cylinder of Mini
Abutment •Titanium Cylinder of Mini
Abutment •Brass Cylinder of Mini
Abutment
•Angled Post 17° •Castable UCLA •Titanium UCLA •CoCr UCLA
3.3 and 3.5 mm
3.75 and 4.0 mm
4.3 mm
4.5 and 5.0 mm
EXTERNAL HEX
Inte
rna
l Thre
ad
Ø 1
.8In
tern
al T
hre
ad
Ø 2
.0In
tern
al T
hre
ad
Ø 2
.0In
tern
al T
hre
ad
Ø 2
.5
•Angled Post 17° •Customizable Post •Castable UCLA •Titanium UCLA •CoCr UCLA
•Mini Ball Attachment
1 mm
1 mm
Ø 4.3 mm
E x t e r n a lH e x
COMPONENTS INDICATION TABLE
Screw-retained Prosthesis
Cemented Prosthesis
Overdenture Protocol
60
•Cylindrical implant with External Hex interface;
•NeoPoros Surface;
•Capture and installation with contra-angle or manual
without mount use (reduction of surgical time);
•Installation by the internal hexagon of the implant,
increasing the mechanical strength when high torques are
applied, preserving the integrity of the external hexagon;
•Double thread (faster installation and less trauma);
•High cutting capacity;
•Suitable for bones type I and II and grafting areas in block
•Cover screw and mount not included;
•Prosthetic platform: 4.1mm and 5.0mm;
•Perforation rotation: 800-1200 rpm;
•Installation rotation: 30 rpm.
Product Characteristics:
•Cylindrical implant with External Hex interface;
•NeoPoros Surface;
•Capture and installation with contra-angle or manual
without mount use (reduction of surgical time);
•Installation by the internal hexagon of the implant,
increasing the mechanical strength when high torques are
applied, preserving the integrity of the external hexagon;
•Double thread (faster installation and less trauma);
•High cutting capacity;
•Suitable for bones type I and II and grafting areas in block
•Cover screw and mount not included;
•Prosthetic platform: 4.1mm and 5.0mm;
•Perforation rotation: 800-1200 rpm;
•Installation rotation: 30 rpm.
Product Characteristics:
3.75 mm
4.0 mm
4.5 mm
5.0 mm
Init
ial
Dri
ll
Tit
am
ax
Dri
ll 2
.0
Pil
ot
2/3
Tit
am
ax
Dri
ll 3
.0
Tit
am
ax
Dri
ll 3
.3
Tit
am
ax
Dri
ll 3
.15
Pil
ot
3/3
.75
Co
un
ters
ink
4.1
SF
Tit
am
ax
Dri
ll 3
.8
Tit
am
ax
Dri
ll 4
.3
Co
un
ters
ink
5.0
SF
Optional
Drill sequence
61
9.0 mm7.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm
Ø 4.0
Ø 3.75
Platform(4.1)
Platform(4.1)
Platform(5.0)
Platform(5.0)
Ø 4.5
Ø 5.0
109.284 109.285 109.286 109.287 109.288
109.302 109.303 109.304 109.305 109.306
109.327 109.328 109.329
109.294 109.295 109.296 109.297
Cover Screw
117.018 117.003
4.1 mm 5.0 mm
•Use Digital Driver 0.9mm (104.039) to the
installation of Cover Screw platform 4.1 and Digital
Driver 1.2mm (104.007) to the installation of Cover
Screw platform 5.0;
•Do not exceed torque of 10 N.cm.
106.092
106.127 106.128 106.129
106.093 106.094
2.0 mm 3.0 mm 4.0 mm
Ø 4.1
Ø 5.0
Divergent Healings
2.0 mm 3.0 mm 4.0 mm
Ø 4.1
Ø 5.0
Slim Fit Healings
106.195 106.196 106.197
106.190 106.191 106.192
E x t e r n a lH e x
62
•Cylindrical implant with External Hex interface;
•NeoPoros Surface;
•Capture and installation with contra-angle or manual without
mount
use (reduction of surgical time);
•Installation through implant internal hex, increasing the
mechanical resistance (when applied elevated torque),
preserving the external hex integrity;
•Double thread (faster installation and less trauma);
•High compaction capacity (bone expansion);
•Suitable for bones type III and IV;
•Cover screw not included;
•Simplified instrumentation in the prepare of surgical alveolus;
•Prosthetic platform 4.1mm;
•Perforation rotation: 800-1200 rpm;
•Installation rotation: 30 rpm.
Product Characteristics:
•Cylindrical implant with External Hex interface;
•NeoPoros Surface;
•Capture and installation with contra-angle or manual without
mount
use (reduction of surgical time);
•Installation through implant internal hex, increasing the
mechanical resistance (when applied elevated torque),
preserving the external hex integrity;
•Double thread (faster installation and less trauma);
•High compaction capacity (bone expansion);
•Suitable for bones type III and IV;
•Cover screw not included;
•Simplified instrumentation in the prepare of surgical alveolus;
•Prosthetic platform 4.1mm;
•Perforation rotation: 800-1200 rpm;
•Installation rotation: 30 rpm.
Product Characteristics:
3.75 mm
4.0 mm
Init
ial
Dri
ll
Tit
am
ax
Dri
ll 2
.0
Pil
ot
2/3
Tit
am
ax
Dri
ll 2
.8
Tit
am
ax
Dri
ll 3
.0
Optional
Drill sequence
Internal Torque
63
9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm
Ø 4.0
Ø 3.75
109.588
109.582
109.589
109.583
109.590
109.584
109.591
109.585
109.592
109.586Platform
(4.1)
Platform(4.1)
Cover Screw
117.0184.1 mm
•Use Digital Driver 0.9mm (104.039) to the
installation of Cover Screw platform 4.1;
•Do not exceed torque of 10 N.cm.
106.092 106.093 106.094
2.0 mm 3.0 mm 4.0 mm
Ø 4.1
Divergent Healings
2.0 mm 3.0 mm 4.0 mm
Ø 4.1
Slim Fit Healings
106.190 106.191 106.192
E x t e r n a lH e x
64
•Conical implant with External Hex interface;
•NeoPoros Surface;
•Capture and installation with contra-angle or manual
without mount use (reduction of surgical time);
•Installation through implant internal hex, increasing the
mechanical resistance (when applied elevated torque),
preserving the external hex integrity;
•Suitable for bones type III and IV and pos-extracting
installation;
•Cover screw and mount not included;
•External Hex with height of 1mm: platform 4.3 and 5.0;
•Perforation rotation: 500-800 rpm;
•Installation rotation: 30 rpm.
Product Characteristics:
•Conical implant with External Hex interface;
•NeoPoros Surface;
•Capture and installation with contra-angle or manual
without mount use (reduction of surgical time);
•Installation through implant internal hex, increasing the
mechanical resistance (when applied elevated torque),
preserving the external hex integrity;
•Suitable for bones type III and IV and pos-extracting
installation;
•Cover screw and mount not included;
•External Hex with height of 1mm: platform 4.3 and 5.0;
•Perforation rotation: 500-800 rpm;
•Installation rotation: 30 rpm.
Product Characteristics:
4.3 mm
5.0 mm
Init
ial
Dri
ll
Alv
im D
rill
2.0
Alv
im D
rill
3.5
Alv
im D
rill
4.3
Alv
im D
rill
5.0
Co
un
ters
ink
4.3
Co
un
ters
ink
5.0
SF
Optional
Drill sequence
65
Ø 5.0
Ø 4.3
10.0 mm 13.0 mm 16.0 mm
109.321 109.322 109.323
109.324 109.325 109.326
Cover Screw
117.006 117.003
4.3 mm 5.0 mm
•Use Digital Driver 0.9mm (104.039) to the installation
of Cover Screw platform 4.3 and Digital Driver 1.2mm
(104.007) to the installation of Cover Screw platform 5.0;
•Do not exceed torque of 10 N.cm.
106.140
106.127 106.128 106.129
106.141 106.142
2.0 mm 3.0 mm 4.0 mm
Ø 4.3
Ø 5.0
Divergent Healings
2.0 mm 3.0 mm 4.0 mm
Ø 4.3
Parallel Healings
106.132 106.133 106.134
2.0 mm 3.0 mm 4.0 mm
Ø 5.0
Slim Fit Healings
106.195 106.196 106.197
E x t e r n a lH e x
66
•Cylindrical implant with External Hex;
•NeoPoros Surface;
•Cover screw not included;
•Double thread (faster installation and less trauma);
•High cutting capacity;
•Suitable for bones type I and II in reduced prosthetic
spaces (upper lateral incisor and lower incisor);
•Prosthetic platform 3.3mm;
•External Hex with height of 1mm;
•Resistance to the installation torque: 45 N.cm;
•Perforation rotation: 800-1200 rpm;
•Installation rotation: 30 rpm.
Product Characteristics:In
itia
l D
rill
Tit
am
ax
Dri
ll 2
.0
Tit
am
ax
Dri
ll 2
.8
Co
un
ters
ink
3.3
Drill Sequence
Cortical with Mount
67
11.0 mm9.0 mm 13.0 mm 15.0 mm 17.0 mm
Ø 3.3
109.140 109.141 109.142 109.143 109.144
Cover Screw
117.0013.3 mm
•Use Digital Driver 0.9mm (104.039) to the installation
of Cover Screw platform 4.3;
•Do not exceed torque of 10 N.cm.
106.065 106.066 106.067
2.0 mm 3.0 mm 4.0 mm
Ø 3.3
Divergent Healings
2.0 mm 3.0 mm 4.0 mm
Ø 3.3
Parallel Healings
106.060 106.061 106.062
68
•Conical implant with External Hex;
•NeoPoros Surface;
•Cover screw not included;
•Suitable for bones type III and IV in reduced
prosthetic spaces (upper lateral incisor and lower
incisor) and pos-extracting installation;
•Prosthetic platform 3.3mm;
•External Hex with height of 1mm;
•Resistance to the installation torque: 45 N.cm;
•Perforation rotation: 500-800 rpm;
•Installation rotation: 30 rpm.
Product Characteristics:
Optional
Init
ial
Dri
ll
Alv
im D
rill
2.0
Alv
im D
rill
3.5
Co
un
ters
ink
3.3
Drill sequence
with Mount
69
Ø 3.5
10.0 mm 13.0 mm 16.0 mm
109.217 109.218 109.219
Platform(3.3)
Cover Screw
117.0013.3 mm
•Use Digital Driver 0.9mm (104.039) for the installation
of Cover Screw platform 3.3;
•Do not exceed torque of 10 N.cm.
106.065 106.066 106.067
2.0 mm 3.0 mm 4.0 mm
Ø 3.3
Divergent Healings
2.0 mm 3.0 mm 4.0 mm
Ø 3.3
Parallel Healings
106.060 106.061 106.062
70
External Hex
The Slim Fit Line is the Neodent’s innovation for External Hex components, due to its parallel emergent profile which minimizes the bone renoval.
Get to know the benefits of the SLIM FIT line, and see how
certain details can make all the difference:
- Facilitates the fitting of the prosthetic component
by reducing the interference with the cortical bone;
- Preserves the cortical bone plates;
- Optimizes installation;
- Eases the procedures for soft tissue synthesis
(stitching) by increasing the abutment’s conicity.
Reduced Osteotomy
CONVENTIONAL ABUTMENT WITH SF OSTEOTOMY
SF ABUTMENT WITHCONVENTIONAL OSTEOTOMY
71
The SLIM FIT intermediaries provide an excellent
accommodation of peri-implant soft tissue, easing the
prosthetic procedures in surgical cases with immediate
loading and tissue stabilization at long term.
Less Aggressive Drills
For the SLIM FIT line, it is necessary to use the new
Countersink SF Drill, which has a new shape that reduces
the drilling diameter, reducing trauma and preserving the
bone tissue.
Soft Tissue Accommodation
Countersink SF Drill, which has a new shape that reduces
the drilling diameter, reducing trauma and preserving the
bone tissue.
Emergent Profile Slim Fit
Emergent Profile Conventional
CONVENTIONAL OSTEOTOMY
COUNTERSINK CONVENTIONAL NEW DRILL COUNTERSINK SLIM FIT
SLIM FIT OSTEOTOMY(LESS BONE REMOVAL)
7272
Demonstrative sequence of
External Hex
Conical Abutment
•Available in Titanium;
•Minimum interocclusal space of 6.1mm on platform 4.1,
and 6.7mm on platform 5.0mm, from the mucosa level;
•Conicality 15°;
•Single screw-retained prosthesis (anti-rotational);
•Cylinders with screw;
•Slim Fit components, that minimize bone remotion of
the Countersink Drill, facilitating the intermediate seating
and the tissue accommodation.
Torque Connection 1.2
SF ConicalAbutment 4.1mm
ConicalAbutment 4.3mm
ConicalAbutment 5.0mm
ProstheticAbutment Driver
TorqueConnection 1.6mm
Prosthetic Torque Ratchet Driver
Sequence 4.1 / 4.3 mm
Sequence5.0 mm
Conical AbutmentTransfer 5.0Open Tray
Conical AbutmentTransfer 4.1Open Tray
Conical AbutmentTransfer 5.0Closed Tray
Conical AbutmentTransfer 4.1Closed Tray
Conical AbutmentAnalogue 4.1
Conical AbutmentAnalogue 5.0
Protective Cylinder ofConical Abutment 4.1
Protective Cylinder ofConical Abutment 5.0
Prosthetic Torque Ratchet Driver
Conical Abutment Cylinder 4.1 Conical Abutment Cylinder 5.0
Ca
sta
ble
Tit
an
ium
Co
Cr
Ca
sta
ble
Tit
an
ium
Co
Cr
20N.cm
73
Ø 4.1
Ø 5.0
ConicalAbutment Analogue
Ø 4.1
Ø 5.0
Protective Cylinder ofConical Abutment
ConicalAbutment Transfer
Ø 4.1
Ø 5.0
Ø 4.1
Ø 5.0
Cylinder Screw ofConical Abutment
Titanium Neotorque
•Available in Titanium;•Component with molding function by prosthesis construction;
•For open tray or closed tray technique;•Select transfer according to the component to be molded, as prosthetic planning;
•Anti-rotational.
•Available in Titanium;•Used to protect the component during the prosthesis construction;
•To installation, use Digital Driver 1.2mm (104.007);
•Observe the compatible diameter with the prosthetic component.
•Available in Titanium;•Replica of implant platform or prosthetic component;
•For prosthesis construction or prosthetic planning;
•Observe compatible diameter with the prosthetic component.
Castable Titanium CoCr
ConicalAbutment Cylinder
Ø 4.1
Ø 5.0
•Observe corresponding sequence to the component diameter and indicated torque;
•For torque, use Prosthetic Abutment Driver (105.009), except for Ø 5.0 Torque Connection 1.6mm (105.006);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
•Available in: Titanium: provisional prosthesis; CoCr: overcasting; Castable: casting.•Observe the corresponding sequence to the component diameter;
•Screw included;•To screw torque, use Torque Conection 1.2mm (105.005);
•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);
•Anti-rotational.
1 mm 2 mm
Ø 4.1
Ø 5.0
Ø 4.3
3 mm
Conical Abutment
Sli
m F
it
115.051 115.052 115.053
115.007 115.008 115.009
115.192 115.193 115.194
101.030
101.027
106.051
106.052
118.106 118.107 118.233
118.253118.110 118.111
108.035
108.025 108.104
Open Tray
108.075
Closed Tray
116.004 116.231
116.005 116.232
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
74
Torque Connection 1.2
Torque Connection
1.2 mm
Prosthetic Torque Ratchet Driver
Sequence 3.3 / 4.1 / 4.3 mm
Sequence 5.0 mm
Mini Conical Abutment Analogue 4.1 Mini Conical Abutment Analogue 5.0
Protective Cylinder ofMini Conical Abutment 4.1
Protective Cylinder ofMini Conical Abutment 5.0
Prosthetic Torque Ratchet Driver
Open TrayTransfer Mini
Conical Abutment 4.1
Open TrayTransfer Mini
Conical Abutment 5.0
Closed TrayTransfer Mini
Conical Abutment 5.0
Angled Mini
Abutment 170 and 300
20N.cm
20N.cm
Cylinder of Mini Conical Abutment 4.1 Cylinder of Mini Conical Abutment 5.0
Ca
sta
ble
Tit
an
ium
Co
Cr
Ca
sta
ble
Tit
an
ium
No
ble
/ C
oC
r
Prosthetic
Abutment Driver
Prosthetic
Abutment Driver
Mini Conical Abutment
3.3 mm / 4.3 mm
SF Mini Conical
Abutment 4.1mm
32N.cm
Torque Connection
1.6mm
SF Mini Conical
Abutment 5.0 mm
32N.cm
Closed TrayTransfer Mini
Conical Abutment 4.1
74
Demonstrative sequence of
Mini Conical AbutmentAngled Mini Conical Abutment
•Available in Titanium;
•Minimum interocclusal space of 4.4mm on platform 4.1,
and 4.8mm on platform 5.0mm, from the mucosa level;
•Screw-retained and multiple prosthesis (rotational);
•Conicality 20°;
•Mini Angled Abutment presents 12 positions of fitting;
•The cylinders come with Neotorque screw, except the
castables, that comes with Titanium screw;
•Slim Fit components improve tissue accommodation,
installed after using Countersink Drill, which minimizes
bone removal.
External Hex
75
108.024
108.022 108.068
Mini ConicalAbutment Transfer
Short Screw
Opentray Multifunctional
Ø 4.1
Ø 5.0
•Available in Titanium;•Component with molding function to the prosthesis confection;
•For Open Tray or Closed Tray technique;•Select the transfer in accordance with the component to be moulded conforming to the planned prosthetics;
•Rotational.
2 mm
Ø 4.1
Ø 3.3
Ø 5.0
Ø 4.3
3 mm 4 mm
Angled MiniConical Abutment
115.084
115.137
115.074
115.138
115.075
115.139
115.076 115.077 115.078
115.094 115.095 115.096
170
•Minimum interocclusal space of 5.0mm for 17º and 5.5mm for 30º;
•Screw-retained and multiple prosthesis (rotational);
•Observe corresponding sequence to the component diameter;
•For torque, use Torque Connection 1.2 (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
118.112 118.113
118.114 118.115 118.240
Castable Titanium
118.206 118.209 118.210
Noble CoCrCoCr
for welding
Mini ConicalAbutment Cylinder
Ø 4.1
Ø 5.0
1 mm 2 mm
115.187 115.188
115.054
115.134
115.055
115.135
115.056
115.136
115.057
115.197 115.198 115.199
Ø 4.1
Ø 5.0
Ø 4.3
Ø 3.3
3 mm 4 mm
115.189 115.190
Mini Conical Abutment
Sli
m F
itS
lim
Fit
•Observe corresponding sequence to the component diameter;•For torque, use Prosthetic Abutment Driver (105.009), except for Ø 5.0 Torque Connection 1.6mm (105.006);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Ø 4.1
Ø 5.0
106.054
106.055
Protective Cylinder ofMini Conical Abutment
•Available in Titanium;•Used to protect the component during the prosthesis construction;
•To installation, use Digital Driver 1.2mm (104.007);
•Observe the compatible diameter with the prosthetic component.
Ø 4.1
Ø 5.0 101.022
101.020
Mini ConicalAbutment Analogue
•Available in Titanium;•Replica of prosthetic component;•For prosthesis confection or prosthetic planning.
Ø 4.1
Ø 5.0
Cylinder Screw ofMini Conical Abutment
Titanium Neotorque
116.037 116.227
116.038 116.228
Ø 4.1
Ø 5.0
Ø 4.3 115.111 115.112
115.143 115.144
115.140 115.141
300
108.023
108.021
Closed tray
116.036
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
•Available in: Titanium: provisional prosthesis; CoCr: overcasting; Castable: casting; Noble: gold alloy with high melting range.•Screw included;•Observe the corresponding sequence to the component diameter;•To screw torque, use Torque Conection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Rotational for screw-retained multiple elements.
76
4.5
4.1
Transm
uco
us
4 ou 6
Universal Post Transfer
SF Universal Post
Neotorque Screw
Torque Connection 1.2
Universal Post Analogue
Universal Post Cylinder
Alumina
Universal Post Cylinder
Provisional
Universal Post Cylinder
Castable
Ø4.5 Ø4.5 Ø4.5
Ø4.5
Ø4.5
32N.cm
76
Demonstrative sequence of
SF Universal Post
•Available in Titanium;
•Cemented prosthesis;
•The Universal Post can be prepared according to
circunstances, and, in this case, the prosthetic sequence
can not be used;
•Compatible with platform 4.1 and 4.3 External Hex;
•Screw not included, for single elements select Neotorque
Screw;
•Available in two heights of cemented area: 4 or 6mm.
External Hex
Prosthetic TorqueRatchet Driver
77
•Available in polymer;•Component with molding function to prosthesis confection;
•For closed tray technique;•Select transfer according to the component to be molded, as prosthetic planning;
•Anti-rotational.
1 mm
4 m
m
4 m
m
4 m
m
4 m
m
2 mm
6 m
m
6 m
m
6 m
m
6 m
m
Ø 4.5
Ø 4.5
Ø 4.5
Ø 4.5
3 mm
SF UniversalPost
UniversalPost Analogue
UniversalPost Set
•Available in Titanium;•Replica of prosthetic component;•For prosthesis confection or prosthetic planning.
•Components Kit of Universal Post line, containing Transfer and Provisional / Castable Cylinders.
108.045
108.044
UniversalPost Transfer
101.041
101.040
108.062
108.063
4 m
m6
mm
Ø 4.5
118.188 118.183 118.194
118.189 118.184 118.195
ProvisionalAlumina Castable
UniversalPost Cylinder
Ø 4.1
Ø 4.3
Neotorque Titanium
Hex Screw
116.180
114.428
114.431
114.429
114.432
114.430
114.433
116.002
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
• Available in: Acrylic: provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting.• Compatible with all Universal Posts, if not prepared.
78
Torque Connection 1.2
Prosthetic Torque
Ratchet Driver
Neotorque Screw4.1mm
Neotorque Screw5.0 mm
Titanium Screw
Customizable Post 4.1mm
CustomizablePost 5.0mm
Angled Post(170 and 300)
3.3/ 4.1/ 4.3 / 5.0 mm
Implant Analogue
3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm
Closed tray Transfer
3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm
Open tray Transfer
3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm
32N.cm
32N.cm
32N.cm
Neotorque Screw
78
Demonstrative sequence of
Customizable Post Angled Post
• Available in Titanium;
• Cemented prosthesis;
• Angled Post presents 12 positions of fitting, and include
Titanium screw;
• Customizable Post without screw. It is recommended to
use the Neotorque screw.
External Hex
79
Ø 3.3
Ø 3.3
Ø 4.3
Ø 4.3
Ø 4.1
Ø 4.1
Ø 5.0
Ø 5.0
•Available in Titanium; •Component with molding function by prosthesis construction;•For open tray or closed tray technique;•Select transfer according to the implant to be molded, as prosthetic planning.
Implant Transfer
108.012
Anti
-rota
tiona
lRota
tiona
l
108.013
108.038
108.029
108.066 (SF)
108.003
108.002
108.001
108.011
108.034
108.067 (SF)
108.006
Open tray Closed tray
2 mm 3 mm
Ø 3.3
Ø 4.3
Ø 4.1
Ø 4.1
Ø 5.0
4 mm
Angled Post
•Titanium screw included;•To torque, use Torque Connection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);•Anti-rotational.
114.025 114.026 114.027
114.016 114.017 114.018
114.049 114.050 114.051
114.071 114.072 114.073
170
114.009 114.010300
Ø 3.3
Ø 4.3
Ø 4.1
Ø 5.0
ImplantAnalogue
101.002 101.001
Titanium Brass
101.004 101.003
101.028 101.024
101.006 101.005
•Available in Brass and Titanium;•Replica of implant platform;•For prosthesis construction and/or prosthetic planning.
Ø 4.1 para Ø 5.0
Ø 4.1 para Ø 6.0
Ø 5.0 para Ø 6.0
•To unitary elements, select Neotorque Screw;•Screw not included;•To installation, use Torque Connection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
CustomizablePost
114.029
114.030
114.035
Ø 3.3
Ø 4.3
Ø 4.1
Ø 5.0
Hex Screw
116.188 116.001
116.189 116.003
116.180 116.002
Neotorque Titanium
• Observe indicated torque;• Use Torque Connection 1.2mm (105.005);
• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
80
Analogue3.3 mm
Analogue4.1 mm
Analogue4.3 mm
Analogue5.0 mm
UCLA3.3 mm
UCLA4.1 mm
UCLA4.3 mm
UCLA5.0 mm
Torque Connection 1.2
Prosthetic Torque Ratchet Driver
32N.cm
Neotorque Screw
Closed Tray Transfer
3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm
Open Tray Transfer
3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm
80
Demonstrative sequence of
UCLA
•Prosthetic component directly over the implant hex;
•For screw-retained or cemented prosthesis;
•Available in Rotational or Anti-Rotational;
- Tilite and CoCr: overcastting;
- Castable: casting;
- Titanium: Provisional or Cemented Prosthesis
- Gold: Overcasting with high melting range leagues.
•With Titanium and Neotorque screw;
•For unitary elements, select Neotorque screw.
External Hex
81
108.011
108.034
Ø 3.3
Ø 3.3
Ø 4.3
Ø 4.3
Ø 4.1
Ø 4.1
Ø 5.0
Ø 5.0
Implant Transfer
108.012
Anti
-rota
tiona
lRota
tiona
l
108.013
108.038
108.029
108.066 (SF)
108.003
108.002
108.001
108.067 (SF)
108.006
Open Tray Closed Tray
116.003
116.002
116.001Ø 3.3
Ø 4.3
Ø 4.1
Ø 5.0
Hex Screw
116.188
116.189
116.180
Neotorque Titanium
Ø 3.3
Ø 4.3
Ø 4.1
Ø 5.0
ImplantAnalogue
101.002
Titanium
101.001
Brass
101.004 101.003
101.028 101.024
101.006 101.005
•Available in Brass and Titanium;•Replica of implant platform;•For prosthesis construction and/or prosthetic planning.
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
Ø 3.3
Ø 3.3
Ø 4.3
Ø 4.3
Ø 4.1
Ø 4.1
Ø 5.0
Ø 5.0
UCLA
Anti
-rota
tiona
lRota
tiona
l
118.204
118.097
118.009
118.040
118.212
118.235
118.237 118.006
118.101
118.004
118.001
CastableCobalt-Chromium
(Cocr)
118.008
NobleTitanium
118.205
118.152
118.030
118.211
118.234
118.236 118.007
118.119
118.005
118.002
•Available in Titanium; •Component with molding function by prosthesis construction;•For open tray or closed tray technique;•Select transfer according to the implant to be molded, as prosthetic planning.
82
Mini BallAttachment
4.1
Mini BallAttachment
4.3
Mini BallAttachment
5.0
Prosthetic Abutment Driver
Prosthetic Torque Ratchet Driver
Straightpositioner
Positioner70
Positioner140
O’ring with Cylinder
Protection Disk
32N.cm
82
Demonstrative sequence of
Mini Ball Attachment
•Available in Titanium;
•Application of Nitride Titanium coating to increase the
wear resistance;
•Directly over the implant;
•It´s recommended capture the components in patient’s
mouth, one by one;
•O’ring with protection disc;
•See the demonstrative sequence of Mini Ball Attachment
on page 126.
External Hex
Protection Disk Positioner
83
102.060 102.061 102.062
102.063 102.064 102.065
102.066 102.067 102.068
Mini BallAttachment
2 mm
Ø 4.1
Ø 4.3
Ø 5.0
3 mm 4 mm
•Select according to mucosa height;•To installation, use Prosthetic Abutment Driver (105.009);
•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Castable BallAttachment
•Casting in various metals;•May be cemented in natural roots or waxed in bars for overdenture retention.
102.078
straight, 70 and 140
Positioners
•Available in polymer;•Defines the correct distance between Attachment Ball and O’ring;•Corrects the parallelism between implants;•Essential for O’ring capturing.
102.076
102.073
102.077
O’ring with Cylinder
Mini O’ring
Protection Disk
102.075
O’ringRemover
O’ringMount
104.044
104.043
•Digital Driver with function of O’ring replacing to the cylinder.
•Digital Driver with function of O’ring placement to the cylinder.
•Available in Titanium (cylinder);•Available in polymer (O’ring);•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
•Not autoclavable.
•Available in polymer;•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
•Not autoclavable.
•Package with 10 units.
84
INTERNAL HEX
Inte
rna
l thre
ad
Ø 1
.6
•Mini Conical Abutment II Plus (multiple)
•UCLA CoCr II Plus (single)
•Conical Abutment II Plus (single)
•Angled Conical Abutment II Plus (multiple)
•Universal Post II Plus •Angled Post II Plus 17°
and 30° •UCLA CoCr II Plus
(single) •UCLA Titanium II Plus
(single)
•Attachment Mini Ball II Plus
•Angled Conical Abutment II Plus
•Conical Abutment II Plus•Cylinder and Ext. Distal
Bar
Passive Fitting Technique•Castable – Mini Abutment
Cylinder •Titanium – Mini Abutment
Cylinder •Brass – Mini Abutment
Cylinder
3.75, 4.3 and 5.0 mm
4.3 and 5.0 mm
Implant diameter
Diameter of Prosthetic Platform
Screw-retained Prosthesis
CementedProsthesis Overdenture Protocol
Platform diameter
2.5 mm
HEXAGON
2.6 mm
COMPONENTS INDICATION TABLE
Deep internal interface which provides more stability and resistance between screw and component.
85
I n t e r n a lH e x
•Prosthetic components with reduced platform in relation to
the implant (Switching Platform);
•Installation driver with tweezers to increase the transport
security and the implant placement;
•Cervical microretentions to bone tissue maintenance;
•Unique prosthetic sequence independent of the implant
platform diameter.
Cervical micro-retentions.Prosthetic components with reduced platform in relation
to the implant(Switching Platform).
86
3.75mm
5.0mm
Init
ial
Dri
ll
Tit
am
ax
Dri
ll 2
.0
Pil
ot
2/3
Tit
am
ax
Dri
ll 3
.0
Pil
ot
3/3
.75
Tit
am
ax
Dri
ll 3
.15
Co
un
ters
ink
II
4.3
Tit
am
ax
Dri
ll 3
.8
Tit
am
ax
Dri
ll 4
.3
Co
un
ters
ink
II
5.0
Optional
Drill Sequence
•Cylindrical implant with Internal Hex interface;
•NeoPoros Surface;
•Double thread (faster installation and less trauma);
•High cutting capacity;
•Suitable for bones type I and II and areas of block grafting;
•Cover screw not included;
•Unique prosthetic interface for all implant diameters;
•Perforation rotation: 800-1200 rpm;
•Installation rotation: 30 rpm.
Product Characteristics:
Prosthetic components with reduced platform in relation to the implant (Switching Platform).
5.0
3.8
87
11.0 mm9.0 mm7.0 mm 13.0 mm 15.0 mm
Ø 3.75
Ø 5.0
109.462 109.463 109.464 109.465 109.466
109.474 109.475 109.476 109.477
Platform(4.3)
Cover Screw
117.014
Healings
4.0 mm3.0 mm2.0 mm
106.176 106.177 106.178
•Use Digital Driver 1.2mm (104.007) for installation;
•Do not exceed torque of 10 N.cm.
I n t e r n a lH e x
88
Product Characteristics:
•Conical implant with Internal Hex interface;
•NeoPoros Surface;
•Suitable for bones type III and IV and pos-extracting
installation;
•Cover screw not included;
•Unique prosthetic interface for all implant diameters;
•Perforation rotation: 500-800 rpm;
•Installation rotation: 30 rpm.
4.3mm
5.0mm
Init
ial
Dri
ll
Alv
im D
rill
2.0
Alv
im D
rill
3.5
Alv
im D
rill
4.3
Co
un
ters
ink
II
4.3
Alv
im D
rill
5.0
Co
un
ters
ink
II
5.0
Optional
Drill sequence
Prosthetic components with reduced platform in relation to the implant (Switching Platform).
5.0
3.8
89
Ø 4.3
Ø 5.0
10.0 mm 13.0 mm 16.0 mm
109.478 109.479 109.480
109.481 109.482 109.483
I n t e r n a lH e x
Cover Screw
117.014
Healings
4.0 mm3.0 mm2.0 mm
106.176 106.177 106.178
•Use Digital Driver 1.2mm (104.007) for installation;
•Do not exceed torque of 10 N.cm.
90
Demonstrative sequence of
Conical Abutment II PlusAngled Conical Abutment II Plus
Torque
Connection 1.2mm
Prosthetic Torque
Ratchet Driver
Prosthetic Abutment
Driver
Conical Abutment
II Plus
Angled Conical
Abutment II Plus
Prosthetic Torque
Ratchet Driver
Conical Abutment Analogue 4.1
Protective Cylinder of
Conical Abutment 4.1
Conical Abutment Cylinder 4.1
Ca
sta
ble
Tit
an
ium
Co
Cr
20N.cm
•Available in Titanium;
•Minimum interocclusal space of 6.1mm from the
mucosa level;
•Conicality 15°;
•Single screw-retained prosthesis (anti-rotational);
•Concept Switching Platform;
•Compatible components with implants diameter
(Ø 3.75, Ø 4.3 and Ø 5.0);
•The cylinders come with Neotorque screw, except
the castables, that comes with Titanium screw.
Conical Abutment
Transfer 4.1Closed tray
Conical AbutmentTransfer 4.1Open tray
Torque
Connection 1.2mm
90
Internal Hex
91
106.051
Protective Cylinder ofConical Abutment
108.035
108.020
108.075
108.018
101.027
ConicalAbutment Analogue
Open tray
Closedtray
Titanium Neotorque
116.004 116.231
Castable
Rota
tio
na
l
Anti
-rota
tio
na
l
Anti
-rota
tio
na
l
Rota
tio
na
l
Titanium CoCr
Conical AbutmentCylinder II Plus
1.0 mm 2.0 mm
Ø 4.1Ø 4.1
Ø 4.1
Ø 4.1
2.0 mm 3.0 mm3.0 mm 4.0 mm
ConicalAbutment II Plus
Angled ConicalAbutment II Plus 170
115.184 115.203115.185 115.204115.186 115.205
118.106
118.104
118.107
118.105
118.233
118.232
•To torque, use Prosthetic Abutment Driver (105.009);
•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);
•Single screw-retained prosthesis (anti-rotational).
• To torque, use Torque Connection 1.2mm (105.005);
• To torque control, use Prosthetic Torque Ratchet Driver (104.026);
• Observe sequence and indicated torque;•For multiple prosthesis (rotational).
•Available: Titanium: Provisional prosthesis; Tilite and CoCr: Overcasting; Castable: Casting.•Screw included;•To screw torque, use Torque Connection 1.2mm (105.005);
•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
•Available in Brass and Titanium;•Replica of implant platform or prosthetic component;
•For prosthesis construction or prosthetic planning.
•Available in Titanium;•Used to protect the component during the prosthesis construction;
•To installation, use Digital Driver 1.2mm (104.007).
•Available in Titanium;•Component with molding function by prosthesis construction;
•For open tray or closed tray technique.
ConicalAbutment Transfer
Cylinder Screw ofConical Abutment
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
I n t e r n a lH e x
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
92
Demonstrative sequence of
Mini Conical Abutment II Plus
Mini ConicalAbutment II Plus
Prosthetic Abutment Driver
Prosthetic TorqueRatchet Driver
Mini Conical AbutmentOpen Tray Transfer
Mini ConicalAbutmentClosed Tray Transfer
Mini ConicalAbutment Analogue
Protective Cylinderof Mini Conical
Abutment
Mini Conical Abutment Cylinder
Tit
an
ium
Ca
sta
ble
Torque Connection 1.2mm
Prosthetic Torque Ratchet Driver
No
ble
/ C
oC
r
20N.cm
•Minimum interocclusal space of 4.4mm from the
mucosa level;
•Screw-retained and multiple prosthesis (rota-
tional);
•Conicality 20°;
•Concept Switching Platform;
•Compatible component with implants diameter II
Plus (Ø 3.75, Ø 4.3 and Ø 5.0);
•The cylinders come with Neotorque screw, except
the castables, that comes with Titanium screw.
92
Internal Hex
93
118.112 118.113
Calcinable Titanium
118.206 118.209 118.210
Noble CoCr CoCrfor welding
Mini ConicalAbutment Cylinder
Ø 4.1
115.155
1 mm 2 mm
115.156 115.157 115.158
3 mm 4 mm
Mini ConicalAbutment II Plus
•To torque, use Prosthetic Abutment Driver (105.009);
•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Ø 4.1 106.054
Protective Cylinder of Mini Conical Abutment
•Available in Titanium;•Used to protect the component during the prosthesis construction;
•To installation, use Digital Driver 1.2mm (104.007).
Ø 4.1 101.020
Mini ConicalAbutment Analogue
•Available in Titanium;•Replica of prosthetic component platform;
•For prosthesis construction or prosthetic planning.
•Available in: Titanium: provisional prosthesis; CoCr: overcastting; Castable: casting; Gold alloy: overcastting with high melting range leagues.•Screw included;•To screw torque, use Torque Connection 1.2mm (105.005);
•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);
•Rotational for screw-retained multiple elements.
Ø 4.1
Cylinder Screw of Mini Conical Abutment
Titanium Neotorque
116.037 116.227
116.036
Ø 4.1 108.022 108.068
Mini ConicalAbutment Transfer
ClosedTray
Short Screw
Multifunctional
•Available in Titanium;•Component with molding function by prosthesis construction;•For open tray or closed tray technique;•Rotational.
108.021
OpenTray
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
I n t e r n a lH e x
94
Demonstrative sequence of
Universal Post II Plus
20N.cm
Universal Post Transfer
Prosthetic Torque Ratchet Driver
Universal Post II Plus
Neotorque Screw
Torque Connection 1.2
Universal Post Analogue
Universal Post
Cylinder Provisional
Universal Post
Cylinder Castable
Ø4.5
Ø4.5
Prosthetic Torque Ratchet Driver
•Available in Titanium;
•Cemented prosthesis;
•The Universal Post can be prepared according
to circunstances, and, in this case, the prosthetic
sequence can not be used;
•Compatible component with implants diameter II
Plus (Ø 3.75, Ø 4.3 and Ø 5.0);
•Screw not included. For single elements, use
Neotorque Screw;
•Available in two heights of cemented area: 4 or 6mm.
Ø3.8
Ø4.5
4 ou 6
Transmucous
Ø4.5 Ø4.5 Ø4.5
94
Internal Hex
Universal Post
Cylinder Alumina
95
•Available in polymer;•Component with molding function by prosthesis construction;
•For closed tray technique;•Select transfer according to the component to be molded, as prosthetic planning;
•Anti-rotational.
1 mm
4 m
m
4 m
m
4 m
m
4 m
m2 mm
6 m
m
6 m
m 6 m
m
6 m
m
Ø4.5
Ø 4.5
Ø 4.5
Ø 4.5
3 mm
Universal Post
UniversalPost Analogue
UniversalPost Set
•Available in Titanium;•Replica of prosthetic component platform;
•For prosthesis construction or prosthetic planning.
•Components Kit of Universal Post line, containing Transfer and Provisional / Castable Cylinders.
114.123 114.124 114.125
114.126 114.127 114.128
108.045
108.044
UniversalPost Transfer
101.041
101.040
108.062
108.063
•Available in: Acrylic: for provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting.•Cemented prosthesis;•Compatible for all Universal Posts, when not prepared.
4 m
m6
mm
Ø 4.5
118.188 118.183 118.194
118.189 118.184 118.195
ProvisionalAlumina Castable
UniversalPost Cylinder
Neotorque Titanium
Hex ScrewII Plus
116.226 116.224
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
96
Demonstrative sequence of
Angled Post II Plus
•Available in Titanium;
•Cemented prosthesis;
•With 6 fitting positions;
•Titanium screw included.
Prosthetic Torque Ratchet Driver
Torque Connection 1.2 mm
Angled Post II Plus
Transfer II Plus
Open Tray
Transfer II Plus
Closed Tray
Analogue II Plus
20N.cm
96
Internal Hex
97
2 mm 3 mm
Ø 4.3
Ø 5.0
4 mm
AngledPost II Plus
•Available in Titanium;•Component with molding function by prosthesis construction;
•For open tray or closed tray technique.
114.171 114.172 114.173170
114.174 114.175300
Analogue II Plus
101.032
101.034
Implant Transfer
Anti
-rota
tiona
l
108.046 108.047
Open TrayClosed Tray
•Available in Brass;•Replica of implant platform;•For prosthesis construction or prosthetic planning.
•To torque, use Torque Connection 1.2mm (105.005);
•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026);
•Anti-rotational.
98
Demonstrative sequence of
UCLA II Plus
Analogue II Plus
UCLA II Plus UCLA II Plus
Co
Cr
Tit
an
ium 20
N.cm
Torque Connection 1.2
Prosthetic Torque Ratchet Driver
Neotorque Screw
•Prosthetic component directly over the implant;
•For screw-retained or cemented prosthesis;
•Available in rotational or anti-rotational models;
•Available in:
-CoCr: overcasting;
-Titanium: provisional or cemented prosthesis;
•Screw not included;
•For unitary elements, select Neotorque screw.
Transfer II Plus
Open Tray
Transfer II Plus
Closed Tray
Internal Hex
98
99
UCLA II Plus
Anti
-rota
tiona
lRota
tiona
l
118.214
118.213
Cobalt-Chromium (Cocr)
118.185
Titanium
116.224
Hex Screw II Plus
116.226
Neotorque Titanium
Ø 4.3
ImplantAnalogue II Plus
101.032
•Available in Brass;•Replica of implant platform;•For prosthesis construction or prosthetic planning.
•Available in Titanium;•Component with molding function by prosthesis construction;
•For open tray or closed tray technique;•Anti-rotational.
Implant Transfer
108.046 108.047
Open TrayClosed Tray
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
100
Demonstrative sequence of
Mini Ball Attachment II Plus
Mini Ball Attachment
II Plus
•Available in Titanium;
•Application of Nitride Titanium coating for
increased the wear resistance;
•Directly over the implant;
•It´s recommended capture the components in
patient’s mouth, one by one;
•Obligatory to use positioner for capture;
•O’ring with protection disc;
•See the demonstrative sequence on page 126.
Prosthetic
Abutment Driver
Prosthetic Torque Ratchet Driver
StraightPositioner
Positioner 70
Positioner140
O’ring with Cylinder
Protection Disk
32N.cm
100
Protection Disk Positioner
101
102.090 102.091 102.092
Mini Ball Attachment II Plus
2 mm 3 mm 4 mm
•Select according to mucosa height; •To installation, use Prosthetic Abutment Driver (105.009);
•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
CastableBall Attachment
•Casting in various metals;•May be cemented in natural roots or waxed in bars for overdenture retention.
102.078
straight, 70 and 140
Positioners
•Available in polymer;•Defines the correct distance between Attachment Ball and O’ring;•Corrects the parallelism between implants;•Essential for O’ring capturing.
102.076
102.073
102.077
O’ring with Cylinder
Mini O’ring
Protection Disk
102.075
O’ringRemover
O’ringMount
104.044
104.043
•Digital Driver with function of O’ring replacing to the cylinder.
•Digital Driver with function of O’ring placement to the cylinder.
•Available in Titanium (cylinder);•Available in polymer (O’ring);•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
•Not autoclavable.
•Available in polymer;•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
•Not autoclavable.
•Package with 10 units.
102
103
Zygomatic Implants
104
Product Characteristics:
• Cylindrical implant;
• Morse Taper interface, with different dimensions of the
conventional implants (same dimensions of WS Titamax
Implant) or External Hex 4.1mm;
• Smooth surface;
• Pre-mounted;
• Cover screw not included;
• Double thread in CM Zygomatic version;
• It is indicated to use the Transepithelial Abutment according
to the prosthetic interface.
Observation: This technique requires specific accreditation.Information on www.neodent.com.br.
Ø 4.4mm
Nom
ina
l leng
th
Ø 3.9mm
Hex 2.7 m
mØ 4.1 mm
0.7 mm
Ø 3
.0 m
m
105
Zygomatic CMCover Screw
117.016
30.0 mm
30.0 mm
35.0 mm
35.0 mm
40.0 mm
40.0 mm
45.0 mm
45.0 mm
47.5 mm
47.5 mm
50.0 mm
50.0 mm
52.5 mm
52.5 mm
109.522 109.523 109.524 109.525 109.526 109.527 109.528
External HexCover Screw
109.460 109.450 109.451 109.452 109.461 109.453 109.454
117.018
4.1 mm
External Hex
Morse Taper
•Use Digital Driver 0.9mm (104.039) to the
installation of Cover Screw;
• Do not exceed torque of 10 N.cm.
•Use Digital Driver 1.2mm (104.007) to the
installation of Cover Screw;
•Do not exceed torque of 10 N.cm.
106
Transepithelial Abutment
External HexTransepithelial
Abutment
Morse TaperTransepithelial
Abutment
Prosthetic Abutment Driver
Transepithelial AbutmentOpen Tray Transfer
Transepithelial Abutment Analogue
Protective Cylinder ofTransepithelial Abutment
Torque Connection 1.2mm
Prosthetic TorqueRatchet Driver
Prosthetic Torque
Ratchet Driver
20N.cm
Transepithelial AbutmentCylinder
CoCr
32N.cm
Demonstrative sequence of
106
Prosthetic Abutment
Transepithelial AbutmentOpen Tray Transfer
Transepithelial Abutment Analogue
Protective Cylinder ofTransepithelial Abutment
Torque Connection 1.2mm
Prosthetic TorqueRatchet Driver
Transepithelial Abutment
323232N.cmN.cmN.cmN.cmN.cmN.cm
•Available in Titanium;
•Minimum interocclusal space of 4.5mm;
•Screw-retained and multiple prosthesis;
•Exclusive for Zygomatic Implants;
•CM model compatible with WS Titamax Implant.
Castable
107
Morse TaperTransepithelial Abutment
CylinderTransepithelial Abutment
Castable CoCr
118.034 118.254
•Available in: Castable: casting; CoCr: overcasting.•With screw.
•To installation, use Prosthetic Abutment Driver (105.009);
•Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Cylinder Screw
116.004 116.231
NeotorqueTitanium
TransferTransepithelial Abutment
108.026
•Available in Titanium; •For Open tray technique; •Rotational.
AnalogueTransepithelial Abutment
101.018
•Available in Titanium; •Replica of transepithelial abutment;
•To the prosthesis confection or prosthetic planning.
Protective CylinderTransepithelial Abutment
106.056
• Available in Titanium;• Suitable to protect the component in mouth during the prosthesis elaboration;
• To installation, use Digital Driver 1.2mm (104.007).
115.023 115.024 115.025
External HexTransepithelial Abutment
3 mm 4 mm 5 mm
115.172 115.173 115.174
3 mm 4 mm 5 mm
•Observe indicated torque;•Use Torque Connection 1.2mm (105.005);
•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Neotorque •Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
108108
Product Characteristics:
• Case in autoclavable polymer;
• Drills and connections for Zygomatic Implants –
External Hex and Morse Taper;
• Insert not included (KAVO).
Observation: This technique requires specific accreditation.
Information on www.neodent.com.br
109
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
110.214
104.042
105.067
105.069
103.190
103.191
103.192
103.193
103.197
103.208
128.016
124.004
129.011
129.012
104.007
104.039
Zygomatic Surgical Kit Case
Zygomatic Installation Driver
Zygomatic Contra-Angle Connection
Connection for exchange of Zygomatic Drills
Zygomatic Spherical Drill 2.9 Plus
Zygomatic Twist Drill 2.7 Plus
Zygomatic Pilot Twist Drill 2.7/3.3 Plus
Zygomatic Twist Drill 3.3 Plus
Zygomatic Countersink Drill CM Plus
Zygomatic Pilot Twist Drill 3.3/3.7 Plus
Zygomatic Height Measurer CM
Zygomatic Labial Protector
Zygomatic Bicortal Probe
Zygomatic Probe
Short Digital Driver 1.2
Short Digital Driver 0.9
Items contained in Zygomatic Kit
* illustrative image
110
111
Surgical Techniques
112
•Specific composition for the technique;
•Case in autoclavable polymer;
•Drivers, connections and surgical
instruments necessary to the Neoguide
technique;
•Technique suitable for virtual planning
and flapless surgery.
Obs.: This technique requires specific accreditation.
Information on www.neodent.com.br
112
•Specific composition for the technique;
•Case in autoclavable polymer;
Characteristics of Neoguide Kit
113
Items included in Neoguide Surgical Kit
Neoguide Surgical Kit Case
Neoguide Mucosal Punch for Contra-Angle
Neoguide Mucosal Punch Manual
Neoguide Drill 1.3
Neoguide Drill 2.0
Neoguide Drill 2.8
Neoguide Drill 3.0
Neoguide Drill 3.3
Neoguide Pilot Drill 3.5
Neoguide Pilot Drill 3.75
Neoguide Pilot Drill 4.0
Narrow Neoguide Mucosal Punch for Contra-angle
Narrow Neoguide Mucosal Punch Manual
Narrow Neoguide Pilot Drill
Neoguide CM Connection 3.5 for Contra-angle
Neoguide CM Connection 3.75 for Contra-angle
Neoguide CM Connection 4.0 for Contra-angle
Neoguide CM Connection 3.5 for Ratchet
Neoguide CM Connection 3.75 for Ratchet
Neoguide CM Connection 4.0 for Ratchet
Narrow Neoguide CM Connection for Contra-angle
Narrow Neoguide CM Connection for Ratchet
Digital Driver 1.2 Short
Digital Driver for Torque Connection
Neoguide Drill Guide 2.0
Neoguide Drill Guide 2.8
Neoguide Drill Guide 3.0
Neoguide Drill Guide 3.3
Neoguide Guide Clamp
Narrow Neoguide Drill Guide 2.0
Narrow Neoguide Drill Guide 2.8
Neoguide Guide Stabilizer
Narrow Neoguide Guide Stabilizer
Surgical Torque Ratchet Driver
Titanium Tweezers
Implant Guide 3.5 Neoguide
Implant Guide 3.75 Neoguide
Implant Guide 4.0 Neoguide
110.250
103.180
103.181
103.179
103.183
103.184
103.185
103.186
103.187
103.188
103.189
103.194
103.195
103.196
105.079
105.080
105.081
105.082
105.083
105.084
105.091
105.092
104.007
104.005
125.033
125.034
125.035
125.036
125.032
125.039
125.040
125.041
125.059
104.027
129.001
125.029
125.030
125.031
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
5
5
5
Reg
ular
Co
mp
lete
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
* illustrative im
age
114
Neoguide Drills
•Available in surgical stainless steel;•Twist Drill for Ø1.3 and Ø2.0 and Tri-Spade for another diameters;
•Drill 1.3 for perforation in the fixing tubes of Surgical Guide;
•Markings from 7 to 17mm.
103.179 103.183 103.184 103.185 103.186
Ø1.3 Ø2.0 Ø2.8 Ø3.0 Ø3.3
103.187 103.188 103.189
Neoguide Pilot Drills
•Available in surgical stainless steel coated in carbon, which provides a lower friction coefficient;
•Preparation of the bone crest for seating of cervical third in CM Titamax Implants;
•Indicated for bones type I and II.
Ø3.5 Ø3.75 Ø4.0
125.029
125.032
125.030 125.031
Ø3.5 Ø3.75 Ø4.0
Mucosal Punch
•Surgical stainless steel coated in carbon, which provides a lower friction coefficient;
•Guided circular incision for mucosa removing;•Rotatory Punch – used with contra-angle;•Manual Punch – used manually with Digital Drivers for Torque Connections (104.028);
•Also indicated as circular scalpel.
•Available in Titanium; •Its function is to stabilize the prototyped guide, after the installation of each implant.
103.180
125.041
103.194
125.059
103.181
103.195
Contra-angle Manual
Neoguide Implant Guide
•Available in Titanium;•Guide for installation of CM Implants in Neoguide Technique;
•The colors indicate the CM Implant diameter.
Guide Clamp
Stabilizer
•Titanium;•Pin for fix the surgical guide over the ridge;•Effective length of 12mm and Ø 1.3mm.
Neoguide Kit
Neoguide Kit
Neoguide Kit
NarrowNeoguide Kit
NarrowNeoguide Kit
NarrowNeoguide Kit
103.196
DRILL PLUS: Count with the application of a thin pellicle with carbon basis, which promotes low friction coefficient and reduction of the heat generated on osteotomy.
115
Drill Guide
•Use the corresponding drill to the Surgical Guide diameter (colors);
•Embedded in the washers of Surgical Guide;•The colors indicate the CM Implant diameter.
125.033Neoguide Kit
125.039NarrowNeoguide Kit
125.034
125.040
125.035 125.036
Ø2.0 Ø2.8 Ø3.0 Ø3.3
•Available in Titanium;•Used with Mini Conical Abutment Ana-logue for obtain the work model;
•3 spreaders with 1mm of height included;•Technique for prosthesis construction before the surgery.
NeoguidePositioner
101.054
Neoguide CM Connection for Contra-angle
Neoguide CM Connectionfor Ratchet
•Available in Titanium; •To insert the implant using motor and contra-angle.
•Available in Titanium; •For manual insertion of the implant using Surgical Torque Ratchet Driver (104.027).
105.079
105.082
Neoguide Kit
Neoguide Kit
105.091
105.092
NarrowNeoguide Kit
NarrowNeoguide Kit
105.080
105.083
105.081
105.084
3.5
3.5
3.75
3.75
4.0
4.0
116
The Neoshape System combines the new technologies in this segment, in order to guarantee precision and quality in the production of the countless prosthetic techniques available in the market. This novelty broadens horizons, offering excellence, adaptation, precision and esthetics in a customized manner, with digital planning.
With it, the prosthesis technician can plan in the PC screen, in a tri-dimensional manner, all the esthetics and functional details of the prosthesis solutions of the laboratory’s daily routine.
Following the completion of the virtual polishing, a digital file is forwarded online to Neodent’s milling center. There, the information of each received case is managed. Next, the file is sent
to last generation equipments, which accurately reproduce the 3D drawings by milling, assuring precision in adaptation and finishing.
The Neoshape System offers, along with its 3D modeling software, a comprehensive library of prosthetic interfaces, including: rotational external hex, anti-rotational external hex, internal hex, Morse taper, Mini Conical Abutment and Universal Post, which can be directly attached to the implant.
Regardless the choice of material for prosthesis fabrication, the mechanic properties and the quality assurance are guaranteed by raw-materials with international quality standards, supplied by controlled origin sources, reinforcing our ethical commitment.
2. Scanning
WORK OF PROSTHESIS
TECHNICIAN
4. Fabrication of the customized piece at the Neodent Milling
Center
NEODENT WORK
3. CAD Modeling with 3D planning software
WORK OF PROSTHESIS
TECHNICIAN
5. Concluded prosthesis with
application of porcelain
WORK OF PROSTHESIS
TECHNICIAN
DENTIST WORK
1. Patient
CAD CAM SYSTEM
117
PROSTHETIC SOLUTIONS
OF THE NEOSHAPE
SYSTEM
Customized Abutment
Unitary Over Intermediate
External Hex, Internal Hex
and Morse Taper
Multiple Over Tooth
External HexUnitary Multiple MultipleUnitary
Universal Post, Customized Post, Conical Abutment, GT
Abutment
Customized Post, Mini Conical
Abutment
Infrastructure
Copings
InfrastructureMini Conical
Abutment
118
Machining of copings virtually planned.
119
Scanning of work model and opposite arch.
Molding of the elements to be restored and opposite arch.
Industrial machining. Quality control at micrometric level.
Virtual planning.
For work over teeht, the plaster model shall be die-cast and have its preparation margins exposed and delimited. For over implant works, the model shall be cast with artificial gingiva.
Different possibilities of techniques and materials.
3
1
5
4
2
6
CAD CAM SYSTEM
120
Passive Fitting
Technique which allows the passive fitting
without welding through Titanium cylinder
cementation in the metallic structure. Used for
multiple prosthesis and results in laboratorial
working time reduction.
Demonstrative sequence of
120
121
118.083
118.250
118.086
118.174
118.089
118.081
118.248
118.084
118.173
118.087
118.082
118.249
118.085
118.172
118.088
Castable
Castable
Castable
Castable
Ø4.1
Ø5.0
Brass
Brass
Brass
Brass
Titanium
Titanium
Titanium
Titanium
Cylinders Passive FittingMini Conical Abutment
Cylinders Passive FittingMicro CM Abutment
Cylinders Passive FittingTransepithelial Abutment
CylindersPassive Fitting GT
Work Screw Passive Fitting
4.1 mm 5.0 mm
116.086 116.087
•Cylinders of brass and titanium with screw; •For installation, use Torque Connection 1.2mm (105.005);
•For torque control, use Prosthetic Torque Ratchet Driver (104.026).
•Cylinders of brass and titanium with screw; •For installation, use Torque Connection 1.2mm (105.005);
•For torque control, use Prosthetic Torque Ratchet Driver (104.026).
•Cylinders of brass and titanium with screw; •For installation, use Torque Connection 1.2mm (105.005); •For torque control, use Prosthetic Torque Ratchet Driver (104.026).
•Cylinders of brass and titanium with screw; •For installation, use Torque Connection 1.2mm (105.005);
•For torque control, use Prosthetic Torque Ratchet Driver (104.026).
•To use in laboratory.
122
1 Regularization of the alveolar ridge. 2 Surgical perforation concluded, checking the correct distance of the Distal Implant in relation to the mentual foramen with a 7mm flag.
3 Installation of 5 CM Cortical Titamax Implants Ø3.75.
4 Installation of CM Mini Abutments. 5 Installation of squared transfers, replacing by the short screws (mini abutment cylinder screw) and making the union of transferents with acrylic resin.
6 Positioning of the Multifunctional Guide to obtain the intermaxillary relations. Make the union with acrylic resin of the transferents. After union, inject fluid silicon to the soft tissue impression.
7Removal of Multifunctional Guide and installation of Mini Abutment Analogues to the transferents.
8 Work model with artificial gingiva. 9 Castable Passive Fitting Cylinder, Brass Passive Fitting Cylinder and Titanium Passive Fitting Cylinder with slots and lower diameter than brass, compensating the casting contraction.
Passive Fiiting Demonstrative sequence of
122
123
1 0 Brass Cylinders are placed over the analogues and receive Castable Cylinders fixed with work screws.
1 1 1 2Casting ring with waxed infrastructure.
1 3
Casted infrastructure.
1 4Infrastructure adaptation over the model.
Final intraoral view.
1 5Observe area for cementation.
1 6
Cementation with Panavia® (Kuraray Med. Inc. Tokyo-Japan) of the structure over the Titanium cylinders;
1 7Cementation with Panavia® (Kuraray Med. Inc. Tokyo-Japan) of the structure over the Titanium cylinders;
124124
Demonstrative sequence of
Distal Bar
•Technique for facilitate mandibular rehabilitations
with Passive Fitting using a prosthesis type
implant-supported provisional protocol.
Ø 4.1
Ø 5.0
Distal BarCylinder
118.169
MiniAbutment
GT
118.170
118.171
•Available in Titanium;•Retentions to facilitate the acrylic resin union;
•Indicated torque: 10 N.cm;•To torque, use Torque Connection 1.2 (105.005).
Ø 4.1
Ø 5.0
Distal Bar
125.011
MiniAbutment
•Use in Distal Implants to strengthen the Cantilever.
GT
125.012
125.023
125
1 2GT Implant installed. 3Wear prosthesis, maintaining the integrity of posterior area.
4
Cylinders installation in Central Implants and of Distal Bar in posterior implants.
5Proof of the inferior prosthesis with wear (centrical occlusion position, without interference in cylinders).
6Placement of a rubber dam over the cylinders to the soft tissue protection.
7
Application of autopolymerizable acrylic resin in the cylinders.
8 9Acrylic resin application between the cylinders.
1 0
Application of inferior prosthesis in wear area, repositioning in mouth, patient in occlusion even your full polimerization.
Implant-supported provisional prosthesis concluded.
1 1
Remotion of inferior prosthesis after resin polimerization, cylinders captured.
Final intraoral posterior view.1 2Wear, finishing and polishing of inferior prosthesis with polishing protectors.
126
Mini Ball Attachment Demonstrative Sequence of
126
127
1 Construction of new total prosthesis
Lateral view of set.
2 Implants installed. 3 Components.
4 Attachment Ball installed. 5 Using of positioners to correct the parallelism between the Implants and determinate the correct distance between O’ring and Attachment.
6 Placement of protection disks.
Placement of O’rings.7 8 9Inferior view of alleviation.
10 First O’ring captured. 11
Proof of prosthesis to verify adaption without interference.
Second O’ring captured. 12
128
129
Bone Grafting and Orthodontic Anchorage
130130
* illustrative image
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Bone Grafting and Orthodontic Anchorage Case
Bone Grafting Manual Driver
Philips Connection for Manual Driver
Philips Connection for Contra-angle
Drill 1.6 for Contra-angle
Drill 1.3 for Contra-angle
Drill 1.1 for Contra-angle
Drill 1.6 for Straight Piece
Drill 1.3 for Straight Piece
Drill 1.1 for Straight Piece
Punch for Bone Grafting and Orthodontic Anchorage
Orthodontic Anchorage Driver
Contra-angle connection – Anchorage - Long
Contra-angle connection – Anchorage – Short
Ratchet Adaptor for contra-angle connections
110.227
104.018
105.063
105.023
103.045
103.079
103.044
103.043
103.078
103.042
103.207
104.033
105.039
105.040
105.025
Complete Kit:Bone Grafting and Orthodontic Anchorage
131
1
1
1
1
1
1
1
1
1
1
1
Bone Grafting and Orthodontic Anchorage Case
Bone Grafting Manual Driver
Philips Connection for Manual Driver
Philips Connection for Contra-angle
Drill 1.6 for Contra-angle
Drill 1.3 for Contra-angle
Drill 1.1 for Contra-angle
Drill 1.6 for Straight Piece
Drill 1.3 for Straight Piece
Drill 1.1 for Straight Piece
Punch for Bone Grafting and Orthodontic Anchorage
110.227
104.018
105.063
105.023
103.045
103.079
103.044
103.043
103.078
103.042
103.207
Bone Grafting Kit
1
1
1
1
1
1
1
1
1
Bone Grafting and Orthodontic Anchorage Case
Drill 1.3 for Contra-angle
Drill 1.1 for Contra-angle
Drill 1.3 for Straight Piece
Drill 1.1 for Straight Piece
Orthodontic Implant Driver
Long Connection
Short Connection
Ratchet Adaptor
110.227
103.079
103.044
103.078
103.042
104.033
105.039
105.040
105.025
Orthodontic Anchorage Kit
132
Expandedhead
Expanded Head
Standard Head
6 mm
Ø 1.5 mm
Ø 2.0 mm
Ø 2.0 mm Ø 3.0 mmØ 3.85 mm
Ø 1.5 mm
Ø 1.5 mm Ø 2.5 mmØ 3.70mm
Ø 2.0 mm
8 mm
8 mm
10 mm
10 mm
12 mm
12 mm
14 mm
14 mm
116.194
Screw forBone Grafting
•Available in Titanium;•Osseous block fixation;•Self-drilling.
116.196 116.198 116.199 116.200
116.203 116.205 116.207
116.210 116.211 116.212
116.214 116.215 116.216
116.213
116.209
7 mm5 mmBand
Ø 1.3mm
Ø 1.3mm
Ø 1.6mm
Ø 1.6mm
9 mm 11 mm
Low
Low
Medium
Medium
•Available in Titanium alloy according to ASTM-F136 (level V);
•Implants for orthodontic movement; •Self-drilling; •Collar height: -Low: 0mm; -Medium: 1mm;•Torque resistance up to 10 N.cm (Ø 1.3mm) and 20 N.cm (Ø 1.6mm).
109.484 109.485 109.486
Hex Size:2.7 mm
Hole Diameter: 0,7mm
109.487 109.488 109.489
109.493109.701 109.494 109.495
109.496109.702 109.497 109.498
Implants forOrthodontic Anchorage
1 m
m
132
Bone Grafting andOrthodontic Anchorage
133
•Available in stainless steel; •Manual installation of Orthodontic Anchorage Implants.
OrthodonticAnchorage Driver
104.033
Punch for Bone Grafting and Orthodontic Anchorage
103.207
•Available in stainless steel ; •Initial severance of cortical.
Connections and Adaptor Orthodontic Anchorage
•Connections for installation of Anchorage Implants with Ratchet or Contra-angle;
•Ratchet Adaptor for Contra-angle Connections(105.025).
105.040
Short
105.039
Long
105.025
Drills forOrthodontic Anchorage
•Available in surgical stainless steel; •Suitable for bones tipe I and II; •Markings referent to the implant length (5, 7, 9 and 11mm).
103.042
7 mm5 mm
9 mm11 mm
103.078 103.043
103.044
Ø 1.1mm Ø 1.3mm Ø 1.6mm
Straight piece
Contra-angle 103.079 103.045
OrthodonticAnchorage Driver
134
Philips Driver
Manual Driver
104.018
105.063
Straight Piece
105.023
Contra-angle
•Assists in handling of Philips Driver (105.063) and of Graver for Bone Grafting and Orthodon-tic Anchorage (103.207).
•Available in stainless steel; •Screw installation for bone grafting.
134
Bone Grafting andOrthodontic Anchorage
135
Package of Orthodontic Anchorage Implant. Cover removal to access the implant.
Capture of the implant with Orthodontic Anchorage Contra-angle Connection.
Installation of the implant with Contra-Angle Connections (105.039 or 105.040).
Insertion option of the implant manually, with Orthodontic Anchorage Driver (104.033) or with Ratchet and Ratchet Adaptor for Contra-angle Connections (105.025).
Implant installed.
1
3
5
2
4
6
•Resistance to torque until 10 N.cm (Ø1.3mm) and 20 N.cm (Ø1.6mm).
136
STERILISE
Sterilize on the eve of or in the day of procedure.
It is recommended, preferably, follow the method
of sterilization by steam autoclaving, and also the
parameters and procedures established in the
regulation BS EN ISO 17665-1:2006 Moist heat.
Requirements for the development, validation
and routine control of a sterilization process for
medical devices, or to proceed conforming to the
instructions manual from the manufacturer of the
autoclave.
WARNING: THE KITS ARE DAMAGED WHEN SEALED
WITH ADHESIVE TAPE.
DO NOT STERILIZE PRODUCTS MADE IN POLYMER AT
HOTHOUSE.
VALIDITY OF STERILIZATION: 7 to 15 days, since kept
in clean environment, dry and away from the sun.
HYGIENE
Kits Neodent and surgical instruments should be
properly cleaned after each use. Do not let them in
contact with moisture for prolonged periods.
1st Step: Disassemble piece (if applicable).
2nd Step: Immerge the whole piece in enzymatic
detergent with solution of 10%.
3rd Step: Wash in an ultrasonic washer for about 10
minutes.
4th step: Rinse with distilled water in abundance to
remove completely the solution residues, making
use of brushes.
5th step: Dry with paper towel or compressed air.
6th step: Realize visual inspection, observing if the
cleaning process has been successful.
If there is any dirt, the piece should be re-immersed
in detergent – 1st and 2nd steps -, and, if is necessary,
the cleaning should be done with the
help of a nylon brush for dental use (repeat the
rinsing and drying sequence).
7th Step: Select the package in accordance with
the sterilization process. Preferably use self-sealing
package of medical grade paper with laminated film.
IMPORTANT: Never store the material without
complete drying. Drying is very important to prevent
oxidations.
ATTENTION: Do not use not incrusted products (non-
enzymatic). They tend to darken the pieces and also
cause oxidation. The use of enzymatic liquid with
concentration higher than 10%, as well as drying of
pieces containing cleaning solution residues, helps
oxidation and must be avoided.
KitsNeodent
137
Surgical and Prosthetic Ratchets are removable and
with torque control.
The parallel indicators have different colors and numbering to indicate the exact size of the implant to
be used.
Drills with carbon treatment (Plus) which reduce friction during surgical procedure.
Surgical tweezers with self-locking of the implant
and milimeter scale for conference during
proceedings.
Great controlduring drilling.
Elimination of lateral cutting, reducing the warming during osteotomy.
Less heating and higher irrigation flow, less surgical trauma.
GASH
POLISHING PROPELLERS
TWIST DRILL
138138
Product Characteristics:
•Case in autoclavable polymer;
•Drivers, connections and surgical instruments
for Titamax Implants and External Hex Alvim,
Internal Hex and Morse Taper.
Obs.: Items contained in Surgical Kit are also
sold separately. Following, three surgical kits are
suggested: Initial, Intermediary and Advanced.
139
Items contained in Surgical Kit Ad
vance
d
Inte
rmed
iary
Init
ial
110.251
103.170
103.171
103.162
103.213
103.163
103.164
103.165
103.166
103.167
103.168
103.172
103.173
103.174
103.209
103.239
103.211
103.242
103.216
103.217
103.218
103.219
103.220
103.091
105.047
105.045
105.046
105.050
105.048
105.049
105.001
105.018
105.002
105.073
105.074
105.075
128.015
113.014
128.019
128.020
128.021
128.022
128.023
104.039
104.007
104.028
104.027
129.004
129.001
105.030
105.031
105.068
103.296
103.297
Surgical Kit Case
Initial Drill PLUS
Alvim Twist Drill 2.0 PLUS
Twist Drill 2.0 PLUS
Pilot Drill 2/3 PLUS
Twist Drill 2.8 PLUS
Twist Drill 3.0 PLUS
Twist Drill 3.15 PLUS
Twist Drill 3.3 PLUS
Twist Drill 3.8 PLUS
Twist Drill 4.3 PLUS
Alvim Drill 3.5 PLUS
Alvim Drill 4.3 PLUS
Alvim Drill 5.0 PLUS
Countersink Drill 3.3 PLUS
SF Countersink Drill 4.1 PLUS
Countersink Drill 4.3 PLUS
SF Countersink Drill 4.5 and 5.0 PLUS
CM Pilot Drill 2.8/3.5 PLUS
CM Pilot Drill 3/3.75 PLUS
CM Pilot Drill 3.3/4.0 PLUS
CM Pilot Drill 3.6/4.3 PLUS
CM Pilot Drill 4.3/5.0 PLUS
Extension Drill
Connection for TI Contra-angle 4.1 and 4.3
Short TI Ratchet Connection 4.1 and 4.3
Long TI Ratchet Connection 4.1 and 4.3
Contra-angle TI Connection 5.0
Short TI Ratchet Connection 5.0
Long TI Ratchet Connection 5.0
Short Hex Connection for Ratchet
Long Hex Connection for Ratchet
Hex Connection for Contra-angle
Short CM Connection for Ratchet
Long CM Connection for Ratchet
CM Connection for Contra-angle
Height Measurer CM
H.E. Long Mount 3.3
Parallel Indicators 2.8/3.5
Parallel Indicators 3.0/3.75
Parallel Indicators 3.3/4.0
Parallel Indicators 3.6/4.3
Parallel Indicators 4.3/5.0
Short Digital Driver 0.9
Short Digital Driver 1.2
Digital Driver for Contra-angle Connections
Surgical Torque Ratchet Driver
Depth Probe
Titanium Tweezers
Short Ratchet Connection II Plus
Long Ratchet Connection II Plus
Contra-angle Connection II Plus
Countersink Drill II Plus 4.3
Countersink Drill II Plus 5.0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
* illustrative image
140140
Product Characteristics:
•Case in autoclavable polymer;
•Drivers, connections and surgical instruments
for CM Titamax Implants and WS Titamax
installation.
Obs.: Items contained in Surgical Kit are also sold separately. Descriptions are shown next.
141
Items contained in WS Kit
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
WS Surgical Kit Case
Initial Drill Plus
Twist Drill 2.0 PLUS
Twist Drill 2.8 PLUS
Twist Drill 3.0 PLUS
Twist Drill 3.3 PLUS
Twist Drill 3.8 PLUS
Twist Drill 4.3 PLUS
Twist Drill 5.3 PLUS
Extension Drill
Pilot Drill 2/3 PLUS
CM Pilot Drill 3.0/3.75 PLUS
CM Pilot Drill 3.3/4.0 PLUS
Pilot Drill 3.8/4.3 PLUS
CM Pilot Drill 4.3/5.0 PLUS
Pilot Drill 4.3/5.3 PLUS
CM Pilot Drill 5.3/6.0 PLUS
Short Digital Driver 1.2
Surgical Torque Ratchet Driver
Short Hex Connection for Ratchet
Long Hex Connection for Ratchet
Hex Connection for Contra-angle
WS Post 4.5x6x0.8 Prosthetic Selection
WS Post 4.5x6x1.5 Prosthetic Selection
WS Post 4.5x6x2.5 Prosthetic Selection
WS Post 4.5x6x3.5 Prosthetic Selection
Parallel Indicators 3.0/3.75
Parallel Indicators 3.3/4.0
WS Parallel Indicators 4.3/5.0
WS Parallel Indicators 5.3/6.0
Titanium Tweezers
Depth Probe
110.218
103.170
103.162
103.163
103.164
103.166
103.167
103.168
103.169
103.091
103.213
103.217
103.218
103.214
103.220
103.215
103.221
104.007
104.027
105.001
105.018
105.002
114.230
114.231
114.232
114.233
128.020
128.021
128.024
128.025
129.001
129.004
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
110.218
103.170
103.162
103.163
103.164
103.166
103.167
103.168
103.169
103.091
103.213
103.217
103.218
103.214
103.220
103.215
103.221
104.007
104.027
105.001
105.018
105.002
114.230
114.231
114.232
114.233
128.020
128.021
128.024
128.025
129.001
129.004
* illustrative image
142
Product Characteristics:
DRILLS PLUS: Counts upon the application
of a thin pellicle with carbon basis which
promotes reduced friction and reduction of
the heat generated in the osteotomy.
ATTENTION:
The drills suffer wear during their use.
Evaluate their cut effectiveness periodically
and observe the need for substitution to
avoid loss of implants.
16.0
13.0
10.011.5
8.0
1.0
Bone level2.0
142
13.0
10.0
5.0
17.015.0
6.0
7.09.0
11.0 13.0
143
InitialDrill Plus
103.170Ø 2.0
•Available in Surgical Stainless Steel;
•Cortical disruption;•Diameter of 2.0mm.
Alvim Drill Plus(Scaled)
•Available in surgical stainless steel and Zirconia;
•Instrumentation sequence of surgical alveolus for Alvim Implants.
103.174 103.255
103.173 103.254
103.172 103.253
SurgicalStainless Steel
SurgicalStainless Steel
SurgicalStainless Steel
SurgicalStainless Steel
SurgicalStainless Steel
Zirconia
Zirconia
Zirconia
Zirconia Zirconia
Ø 3.5
Ø 4.3
Ø 5.0
•Available in Surgical Stainless Steel and Zirconia;
•Its function is increase the surgical alveolus diameter, facilitating the next drill entry;
•Substitutes the Countersink Drill in use of the Morse Taper Implants.
Pilot Drill
103.216 103.272
103.218 103.274
103.219 103.275
103.220 103.276
103.213
103.217 103.273
103.214 103.270
103.215 103.271
2.8/3.5 mm
3.3/4 mm
3.6/4.3 mm
4.3/5 mm
2/3 mm
3/3.75 mm
3.8/4.3 mm
4.3/5.3 mm
103.221 103.2775.3/6 mm
Countersink Drill
•Available in Surgical Stainless Steel and Zirconia;
•Prepare of the bone crest for cervical third seating in Implants 3.3, 3.75, 4.0,4.5 and 5.0mm (external hex) and 4.3, 5.0mm (internal hex).
103.212 103.268
103.239 103.292
103.209 103.265
External Hex
Internal Hex
Ø 4.1(SF)
(SF)
Ø 3.3
103.211 103.267Ø 4.3
Ø 4.3
Ø 4.5/ Ø 5.0
Ø 5.0
103.296 103.298
103.297 103.299
Twist Drill
Ø 2.0 103.162
•Available in Surgical Stainless Steel and Zirconia;
•Instrumentation sequence of surgical alveolus for Titamax Implant;
•Length: 35mm.
Ø 3.0
Ø 3.15
Ø 3.3
103.164 103.245
103.166 103.247
103.165 103.246
Ø 3.8
Ø 4.3
Ø 5.3
103.167 103.248
103.168 103.249
103.169 103.250
Ø 2.8 103.163 103.244
144
CM Contra-Angle Connection
105.075
•For the installation of CM Implants with Surgical Torque Ratchet Driver (104.027);
•With six markings, indicating the position of hex index face;
•The laser markings indicate the implant installation depth, bone level, 1 and 2mm infraosseous and the last marking (3mm) biological space.
•Available in Titanium;•Instrumental for implant position orientation;
•Diameter of the central belt corresponding to the CM Implants diameter;
•Smaller side for use after drill 2.0mm;•Bigger side for use after last drill, before the implant installation.
Parallel Indicators
128.019
128.020
128.021
128.022
128.023
128.024
128.025
WS
2.8/3.5
3.0/3.75
3.3/4.0
3.6/4.3
4.3/5.0
Ø 4.3/5.0
Ø 5.3/6.0
•To capture the implant directly on the pack-age;
•For installation of CM implants with contra-an-gle, or coupled to the Digital Driver (104.028) for manual installation;
•With six markings, indicating the position of hex index face;
•The laser markings indicate the implant instal-lation depth, bone level, 1 and 2mm infraos-seous and the last marking (3mm) biological space.
CM Ratchet Connection
105.073 105.074
Short Long
145
Ratchet ConnectionExternal Hex – Ti
Ratchet ConnectionInternal Hex – Ti
105.049
105.030 105.031
105.048105.046105.045
5.0
4.3/5.0 4.3/5.0
5.04.1/4.34.1/4.3
Short Short
Short
Long Long
Long
•For installation of External Hex Ti Im-plants with Surgical Torque Ratchet Driver (104.027).
•For installation of Internal Hex II PLUS Implants with Surgical Torque Ratchet (104.027);
•With six markings, indicating the position of hex index face.
Contra-angle ConnectionInternal Hex – Ti
•To capture the implant directly on the package;
•For installation of External Hex Ti Implants and Internal Hex Ti Implants with contra-angle, or coupled to the Digital Driver (104.028) for manual installation;
•With tweezers to increase the security in transport and implant installation.
•To capture the implant directly on the package;
•For installation of Internal Hex II PLUS Implants with contra-angle, or coupled to the Digital Driver (104.028) for manual installation;
•With tweezers to increase the security in transport and implant installation.
105.068
4.3/5.0
Contra-angle ConnectionExternal Hex – Ti
105.047 105.050
4.1/4.3 5.0
146
128.015
•Available in Titanium;•For CM prosthetic components selection;•Markings corresponding to the transmucosal height.
1.5
3.55.5
2.5
6.5
4.5
0.8
CM Height Measurer
Drill Extension
•Available in surgical stainless steel;•With screw for drill fixation;•Fixed screw to the drill extension;•For tighten and unleash the screw, it is necessary only around half turn of Hex Driver 1.2 (104.007).
103.091
Titanium Tweezers
•For implants manipulation;•New system of tweezers, that avoids the deviation of the active tip;
•Scale in milimeters, for conference during the procedures;
•Implant self-locking. 129.001
147
Hex Connection for Contra-angle
•Available in surgical stainless steel;•Adaptation of hex mounters;•For implant insertion, using motor and contra-angle;•Silicone ring for best fixing and mounter transport.
105.002
Hex Connection for Ratchet (Ratchet Driver Connection)
•Available in surgical stainless steel;•Adaptation of hex mounters;•Fit in squared ratchets;•Silicone ring for best fixing and mounter transport.
105.018105.001
Long Mount
•Available in Titanium;•Requires Hex Connections 105.002 in motor use and 105.001 for Ratchet;
•Use Hex Driver 1.2mm for handling (104.007);•Long mounters 3.3 and 3.5 indicated for substitute the implant mount in cases of reduced interproximal space (mesio-distal).
113.014
Ø3.3 mm
Depth Probe
•Available in Titanium;•For probing preparation and depth analysis;
•Scale in milimeters for conferences during procedure.
129.004129.004
148
Digital Driver for Contra-angle Connections
•Available in surgical stainless steel;•Connected to the Contra-angle Connections Ti and II Plus, it becomes a manual driver for the implant installation.
104.028
Hex Digital Driver 0.9mm
•Available in surgical stainless steel;•With divergent hex for best fixing and screw transport;
•Handling of Cover Screws in Implants 3.3, 3.5, 3.75, 4.0, 4.3 and Healing 3.3 height 2mm.
-Short: 20 mm; -Medium: 25 mm; -Long: 38 mm.
104.040104.041104.039
Medium LongShort
Hex Digital Driver 1.2mm
•Available in surgical stainless steel;•With divergent hex for best fixing and screw transport;
•Handling of Mounters in Implants and Cover Screws.
-Short: 20mm; -Medium: 25mm; -Long: 38mm.
104.010104.012104.007
Medium LongShort
149
Surgical Torque Ratchet Driver
• Available in surgical stainless steel;• Extremely secure (a variation of less than 5%);• Fitting for square connections;• Collapsible ratchet, that allows the correct cleaning of set.
104.027
Use Instructions
The Surgical Torque Ratchet Driver was projected to allow the required torque application, and also allow that this torque be checked simultaneously with the same instrument.
The Neodent Surgical Torque Ratchet Driver has pre-calibrated torques: 45, 60 and 80 N.cm.
The ratchet function serves for both sides. Just pull and turn the pin driver 180°. However, the torque function is only in clockwise.
•CAUTION: When you reverse the direction of torque, the gear can be detached from the driver body and fall it. Therefore, this reversal should only be done with the driver connected to the piece or outside the patient’s mouth.
• Available in surgical stainless steel;• Extremely secure (a variation of less than 5%);• Fitting for square connections;• Collapsible ratchet, that allows the correct cleaning of set.
For this, only apply the force on the ratchet stem, 1 until it reaches the value set in lateral graduation 2 , which corresponds to the desired torque.
150
110.213
105.065
105.041
105.005
105.006
105.007
105.008
105.009
105.044
105.071
128.015
104.005
104.016
104.026
Prosthetic Kit Case
Torque Connection 0.9
Short Torque Connection 1.2
Torque Connection 1.2
Torque Connection 1.6
Slot Torque Connection
Square Torque Connection
Prosthetic Abutment Driver
Short Prosthetic Abutment Driver
Long Torque Connection 1.2
CM Height Measurer
Digital Driver for Torque Connections
Transfer Driver
Prosthetic Torque Ratchet Driver
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Co
mp
lete
Basi
c
150
* illustrative image.
151
•Surgical stainless steel;•Extremely secure (variation less than 5%);•Fitting for square connections;•Collapsible ratchet, that allows the correct cleaning of set.
Prosthetic Torque Ratchet Driver
104.026
Use Instructions
The Prosthetic Torque Ratchet Driver was projected to allow the required torque application, and also allow that this torque be checked simultaneously with the same instrument.
The Neodent Prosthetic Torque Ratchet has pre-calibrated torques: 10,15,20,32 and 45 N.cm;
The ratchet function serves for both sides. Just pull and turn the pin driver 180°. However, the torque function is only in clockwise.
For this, only apply the force on the ratchet stem, 1 until it reaches the value set in lateral graduation 2 , which corresponds to the desired torque.
•CAUTION: When you reverse the direction of torque, the gear can be detached from the driver body and fall it. Therefore, this reversal should only be done with the driver connected to the piece or outside the patient’s mouth.
Prosthetic Adaption Driver
•Used to fix the analogues and machine the prosthetic components.
104.036
152
Drivers and Connections for Torque
•Available in Surgical Stainless Steel;•Observe corresponding connection to the prosthetic component screw;
•To torque control, the connections must be adapted to the Prosthetic Torque Ratchet Driver (104.026);
•To connections manual torque, must be adapted to the Digital Driver (104.007);
105.009
SquareSlot 1.61.20.9
105.065 105.005 105.006 105.007 105.008 104.005105.041 105.042 105.044
1.6short
1.2short Prosthetic Prosthetic Digital
105.071
1.2long
•Available in Surgical Stainless Steel;•Indicated for Conical Transfer (used in closed tray transfer).
Transfer Driver
104.016
•Available in Surgical Stainless Steel;•Length: -Short: 2 cm; -Medium: 2,6 cm; -Long: 3,8 cm.•Observe screw indications.
Digital Driver 0.9mm Digital Driver 1.2mm
104.039 104.007
Short ShortMedium Medium Long Long
104.041 104.012104.040 104.010
•Available in Surgical Stainless Steel;•Length: -Short: 2 cm; -Medium: 2,6 cm; -Long: 3,8 cm.•Observe screw indications.
105.065
•Observe corresponding connection to the
•To torque control, the connections must be adapted to the Prosthetic Torque Ratchet
•To connections manual torque, must be
153
110.223
114.191
114.192 114.193
114.194
114.195
114.196
114.197
114.198
114.199
114.200
114.201
114.202
114.203
114.204
114.205
114.206
114.207
114.208
114.209
114.226
114.227
114.228
114.210
114.211
114.212
114.213
114.214
114.215
114.216
114.217
114.218
114.219
114.220
114.221
114.222
114.223
114.224
114.230
114.231
114.232
114.233
104.007
114.335
114.336
114.337
CM Post 4.5x4x5.5 Prosthetic Selection
CM Post 4.5x4x6.5 Prosthetic Selection
CM Post 4.5x6x0.8 Prosthetic Selection
CM Post 4.5x6x1.5 Prosthetic Selection
CM Post 4.5x6x2.5 Prosthetic Selection
CM Post 4.5x6x3.5 Prosthetic Selection
CM Post 4.5x6x4.5 Prosthetic Selection
CM Post 4.5x6x5.5 Prosthetic Selection
CM Post 4.5x6x6.5 Prosthetic Selection
CM Angled Post 3.3x6x1.5 17º Prosthetic Selection
CM Angled Post 3.3x6x2.5 17º Prosthetic Selection
CM Angled Post 3.3x6x3.5 17º Prosthetic Selection
CM Angled Post 3.3x6x1.5 30º Prosthetic Selection
CM Angled Post 3.3x6x2.5 30º Prosthetic Selection
CM Angled Post 3.3x6x3.5 30º Prosthetic Selection
WS Post 4.5x6x0.8 Prosthetic Selection
WS Post 4.5x6x1.5 Prosthetic Selection
WS Post 4.5x6x2.5 Prosthetic Selection
WS Post 4.5x6x3.5 Prosthetic Selection
Short Digital Driver 1.2
CM Anatomical Post Lateral 1.5 Prosthetic Selection
CM Anatomical Post Lateral 2.5 Prosthetic Selection
CM Anatomical Post Lateral 3.5 Prosthetic Selection
CM Prosthetic Selection Kit Case
CM Post 3.3x4x0.8 Prosthetic Selection
CM Post 3.3x4x1.5 Prosthetic Selection
CM Post 3.3x4x2.5 Prosthetic Selection
CM Post 3.3x4x3.5 Prosthetic Selection
CM Post 3.3x4x4.5 Prosthetic Selection
CM Post 3.3x4x5.5 Prosthetic Selection
CM Post 3.3x4x6.5 Prosthetic Selection
CM Post 3.3x6x0.8 Prosthetic Selection
CM Post 3.3x6x1.5 Prosthetic Selection
CM Post 3.3x6x2.5 Prosthetic Selection
CM Post 3.3x6x3.5 Prosthetic Selection
CM Post 3.3x6x4.5 Prosthetic Selection
CM Post 3.3x6x5.5 Prosthetic Selection
CM Post 3.3x6x6.5 Prosthetic Selection
CM Post 4.5x4x0.8 Prosthetic Selection
CM Post 4.5x4x1.5 Prosthetic Selection
CM Post 4.5x4x2.5 Prosthetic Selection
CM Post 4.5x4x3.5 Prosthetic Selection
CM Post 4.5x4x4.5 Prosthetic Selection
CM Anatomical Post Height 1.5 Prosthetic Selection
CM Anatomical Post Height 2.5 Prosthetic Selection
CM Anatomical Post Height 3.5 Prosthetic Selection
Optional
153
110.223
114.191
114.192 114.193
114.194
114.195
114.196
114.197
114.198
114.199
114.200
114.201
114.210
114.211
114.212
114.213
114.214
114.215
114.216
114.217
CM Post 4.5x4x5.5 Prosthetic Selection
CM Post 4.5x4x6.5 Prosthetic Selection
CM Post 4.5x6x0.8 Prosthetic Selection
CM Post 4.5x6x1.5 Prosthetic Selection
CM Post 4.5x6x2.5 Prosthetic Selection
CM Post 4.5x6x3.5 Prosthetic Selection
CM Post 4.5x6x4.5 Prosthetic Selection
CM Prosthetic Selection Kit Case
CM Post 3.3x4x0.8 Prosthetic Selection
CM Post 3.3x4x1.5 Prosthetic Selection
CM Post 3.3x4x2.5 Prosthetic Selection
CM Post 3.3x4x3.5 Prosthetic Selection
CM Post 3.3x4x4.5 Prosthetic Selection
CM Post 3.3x4x5.5 Prosthetic Selection
CM Post 3.3x4x6.5 Prosthetic Selection
CM Post 3.3x6x0.8 Prosthetic Selection
CM Post 3.3x6x1.5 Prosthetic Selection
CM Post 3.3x6x2.5 Prosthetic Selection
* illustrative image.
154
155
Surgical Instruments
156
Trephine Burs
103.051 103.026 103.087 103.027 103.028 103.029
Ø3.3 mm Ø 4.1 mm Ø 4.3 mm Ø 5.0 mm Ø 8.0 mm Ø10.0 mm
•Available in Surgical Stainless Steel;
•Osseous cylinder collect;•Implants removal.
Bone Profile Drill
Ø3.3 mm Ø 4.1 mm
External Hex Internal Hex
Ø 4.3 mm Ø 5.0 mm Ø 4.3 mm Ø 5.0 mm
•Available in Surgical Stainless Steel;•Used in the second surgical phase;•Adapt the bone around implant platform, preparing the emergency profile compatible with the prosthetic component profile;
•Each drill has a guide with specific diameter.
103.039 103.030 103.085 103.031 103.102 103.103
Angle Measurer
•Available in Titanium;•Angulations: 17° and 30°;•For selection and angulation planning of prosthetic component during the surgical procedure;
•Use indication: after Twist Drill 2.0.
128.017
170
128.018
300
Flags
128.008 128.007
9 mm 12 mm
128.003
7 mm
•Available in Surgical Stainless Steel;•Adaptive to mirrors handle;•Indicated for surgical/prosthetic planning.
AlvimRadiographic Positioner
129.013 129.014129.009
•Available in Titanium;•Used to check flapless osteotomy depth;•It is suggested make the periapical radiography for evaluation.
Ø 3.5 mm Ø 4.3 mm Ø 5.0 mm
0.35mm
16
11.5
13
10
8
157
1.8 mm
1.8 mm
2.5 mm
2.5 mm
3.0 mm
3.0 mm
3.5 mm
3.5 mm
4.0 mm 4.5 mm
•Available in Surgical Stainless Steel;•Concave cutting tip for atraumatic elevation of maxillary sinus floor;•Used in the preparing of surgical alveolus for implants installation in posterior maxillary area whith less osseous height;•Markings from 7 to 17mm.
•Available in Surgical Stainless Steel;•Convex tip;•Used when thickness bone is insufficient, requiring compression and prior bone expansion to the implant placement;
•Markings from 7 to 17mm.
110.154
110.160
110.155
110.161
110.156
110.162
110.157
110.163
110.158 110.159
Concave Osteotomes
Spreading Osteotomes
Osteotomes Kit Case
• Available in polymer;• Autoclavable;• Osteotomes sold separately.
110.180
4.5 mm
110.159
17 mm
13 mm
9 mm
15 mm
11 mm
7 mm
17 mm
13 mm
9 mm
15 mm
11 mm
7 mm
158
Surgical Mallet
Long Sinus Curette
126.001
• Available in Surgical Stainless Steel;• Used for detachment of sinusal membrane.
126.008
1
126.009
3
126.010
4
126.011
5
126.012
7
•Available in Surgical Stainless Steel;•Active tip in polymer;•Used in Concave and Spreading Osteotomes; •Weight: 130g.
159
Disposable Bone Scraper
•Used to remove autogenous bone;•Single use;•Supplied sterile.
127.023
127.016
Straight
127.017
Positive
127.018
Negative
127.019
Blade
Metal Bone Scraper
•Used to remove autogenous bone applied in reconstructive surgery;
•Includes a blade coated with Titanium Nitride;
•Silicone handle;•Autoclavable.
Disposable Bone Collector
•Available in polymer;•Used to collect autogenous bone;•Single use;•Adaptive to vacuum pump;•Two disposable sieves included;•Use the second tip to saliva suction (beware of contamination).
107.003
107.008
160
Surgical Labial Retractor
124.001
Columbia Retractor
•Available in Surgical Stainless Steel;•Rounded corners to minimize the surgical trauma.
•Available in Surgical Stainless Steel;•Rounded corners to minimize the surgical trauma.
124.003
Scalpel Handle
•Available in Surgical Stainless Steel;•For use of conventional scalpel blade;•Blade not included.
129.008
Blade and Handle Bivers
•Handle and blade in surgical stainless steel;
•Atraumatic exodontics to implants installation;
•Similar with a periostomal;•Blades supplied individually.
129.002
129.005
•Available in Surgical Stainless Steel;
161
Complement Case
•Available in autoclavable polymer;•Used to organize the drills and auxiliar connections.
110.233
Test
Bone Mill
•Available in Surgical Stainless Steel;•Bone volume gain;•The blade has 3 years of warranty against rust;•With lever for better facility during utilization;•Bone mill pestle with slots to optimize the bone block locking during use;•Avoid bone handling originated in tissue bank.
Bovine bone block withvolume = 1,76 cm3
Volume gain was approximately of 7 times.
Amplified particles.
127.011
162
1
2
3
6
7
4
5
Advanced design with simple and intuitive panel. Membrane type keys, free of indentations to facilitate the asepsis.
The Neosurg XT Plus is small, light and can be easily transported anywhere. It is a product ideal for anyone who tends to more than one surgery and wishes to have just one surgical motor.
As well as electronic calibration, the motor has a torque ratchet to guarantee yet more precision of the micro motor and contra-angle. The calibration is executed directly by the professional, without the need for maintenance from the manufacturer.
It´s not necessary to autoclave, the hose system is sterilisation only.
Allows perfect adaption of the irrigation handle, offering resistance and security. Can be sterilised.
Use the magnetic induction system, which does not produce noises nor vibrations. High Precision of the torque and variation of speeds.
Rigid body of the micro motor for no risk breaking. Doesn´t lose brightness with time of use, unlike the LED.
Internal and external irrigation system. Head with a reduced size and ergonomically compact body. Better visibility, access and mobility within the oral cavity.
All adjustments of the irrigation system, programs and speeds can be triggered by the pedal, leaving the hands free for surgical procedure. It was developed to avoid the accidental activation of micro motor system (progressive acceleration).
162
The Neosurg XT Plus is small, light and can be easily transported anywhere. It is a product ideal for anyone who tends to more than one surgery and
system, programs and speeds can be triggered by the pedal, leaving the hands free for surgical procedure. It was developed to avoid the accidental activation of micro motor system
CONTROL PANEL WITH EASIER INTERFACE
Con
trol
Uni
t M
icro
Mot
or a
nd C
ontr
a-an
gle
MECHANICAL CALIBRATION SYSTEM
PERISTALTIC PUMP CONNECTED TO THE MOTOR
IRRIGATION SYSTEM WITH METAL CONNECTORS INTELLIGENT CONTROL PEDAL
PORTABLE
MICRO MOTOR REINFORCED WITH TITANIUM COATING
OPTICAL FIBER (VERSION WITH LIGHT)
CONTRA- ANGLE PUSH BOTTOM
Surgical Motor
Contra-angle
Calibration System
With Light
Electronic and Mechanical
Optical Non-optical
Without Light
Electronic and Mechanical
163163
2 MECHANICAL CALIBRATION
5
67
4
3
1
ILLUMINATION
164
AFFILIATES
Bauru Al. Dr. Octávio Pinheiro Brizolla, 7-46 17.012-059 - Bauru - SP - Brasil Phone: +55 14 3201-3500
Belo Horizonte R. Grão Pará, 554 30.150-341 - Belo Horizonte - MG - Brasil Phone: +55 31 3071-8700
Brasília SH/SUL, QD. 06 CONJ “A” BL. “F” Loja 20 70.316-901 - Brasília - DF - Brasil Phone: +55 61 3298-3200
Curitiba Av. Visconde de Guarapuava, 3832 80.250-220 - Curitiba - PR - Brasil Phone: +55 41 2169-1000
Goiânia R. T-55, 199 - Sl. 4 a 6 74.150-320 - Goiânia - GO - Brasil Phone: +55 62 3878-7700
Londrina R. Senador Souza Naves, 1510 86.010-160 - Londrina - PR - Brasil Phone: +55 43 3306-2000 Porto Alegre R. Félix da Cunha, 836 - Cj. 202 90.570-000 - Porto Alegre - RS - Brasil Phone: +55 51 3272-7400
Recife R. Francisco Alves, 325 - Sl. 401 50.070-490 - Recife - PE - Brasil Phone: +55 81 3202-6900
Rio de JaneiroRua Bento Lisboa, 120 - Lj. “E” Bl. 01 22.221-011 - Rio de Janeiro - RJ - BrasilPhone: +55 21 3622-8900
São Paulo R. Francisco Leitão, 469 - Sl. 1809 05.414-020 - São Paulo - SP - Brasil Phone: +55 11 3728-2700
VitóriaRua Cassiano Antonio Moraes, 100 Loja 0229.050-525 - Enseada do Suá - Vitória - ESPhone: +55 27 3203-5300
INTERNATIONAL AFFILIATES
Portugal Av. Defensores de Chaves, 15 - 3º D 10.00-109 Lisboa - Portugal Phone: +351 21 013 4400
USAJGC North America Corporation3785 NW82 - Avenue Suite 21133166 - Doral, Florida, USAPhone: +305 436 1818
PONTOS DE DISTRIBUIÇÃO NEODENT
FortalezaRua Pedro Borges, nº. 20, sala nº. 808Fortaleza – CE CEP: 60.055-900 UberlândiaAv. Cesário Alvim, 818, sala nº. 504Uberlândia-MGCEP: 38.400-098 Ribeirão PretoRua Rui Barbosa, nº 1145, sala 63, 6º andarRibeirão Preto – SPCEP: 14.015-120
DISTRIBUTORS NEODENT
Campo Grande – MS Alphadent Implantes e Instrumentais R. Padre João Cripa, 2371 – Bairro: Vila Alta CEP: 79.010-180 Phone: 0800 600 5993 / (67) 3027-5993
Cuiabá – MTAlphadent Implantes e Instrumentais Rua das Orquídeas, 337Bairro: Jardim CuiabáCEP: 78.043-148Phone: 0800 601 5993 / (65) 3027-5993 Florianópolis – SC Implantológica - Revenda Neodent R. Felipe Schmidt, 649 - Sala 1401 – CentroCEP: 88.010-001Phone: 0800 600 6069(48) 3225-6069 / (48) 3028-7169
Manaus – AM A R. Rodriguez Av. Joaquim Nabuco, 2235 CEP: 69.020-030Phone: (92) 2121-7700
Salvador - BA Implante Way Produtos Médicos - Odontológicos Ltda Rua Senador Theotônio Vilela, 190 Ed. Convention Center , SL 506 - Pq Bela VistaCEP: 40.279-435 Phone: 0800 284 5378 / Fax: (71) 3351-5378 Palmas – TOProdentis Produtos OdontológicosCentro Comercial Água VivaQuadra 104 Norte, Rua NE 01, nº 27 - Sala 03CEP: 77.006-016Phone: 0800 646 1012 / (63) 3224-1010
Belém – PACIRUBELCirúrgica Belém Com. & Representações LtdaTravessa 9 de Janeiro, 1295CEP: 66.060-370 Phone: (91) 3204 2729 / 8802 4359odonto.vendas@cirubel.com.br
INTERNATIONAL DISTRIBUTORS
ArgentinaDis-Den 1. Santa Fé 3153 2000 Rosario Phone: +54 341 438 4433 2. Fernando Ochoa, 645 1852 Burzaco, Buenos Aireshcalamante@disden.com.ar
Bolivia Odonto Market Calle Ichilo, 205 – Zona B Palermo, Santa Cruz Phone: +591 3 339 4089 / +591 3 339 6410ronald_v@hotmail.com
Chile Comercial Express Dent Av. Presidente Errazuriz, 4125 Las Condes – Santiago - Chile Phone: +56 2 233 6690 / +56 2 263 3720 rafaelrecabarren@expressdent.cl
Colombia Pluss Dent Calle 23 Norte, nº 5 –BN – 69 - Cali Phone: +57 2 660 0050 luismancera@plussdent.com
Equator Odontotec Portete, E 1380 Iñaquito - Quito Phone: +593 2 245 4575 eandrade@cadcam.ec
Spain Perdental Calle Cristóbal De Boleda, 14 25006 - Lleida Phone: +34 9021 17077 / 9021 17120 oficina@perdental.com
ItalyBio-Sfera Via C. Pavese, 50 Peschiera Borromeo – Mi Phone: +39 349 224 1190 roberto.vernice@bio-sfera.com
Lebanon Implanet Dekwaneh Slaf Main Road Yervan Bldg - Beirut Phone: +961 169 2123 joumanasaade@gmail.com
Paraguay Dent. Par Shopping Yguazú Av San Blás 765 - Ciudad del EstePhone: +595 61 510 829/ 30 dentpar@yahoo.comskype: sac.dentpar
Peru Dent Import Av. Teodóro Cárdenas 163, OFC. 1 - Lima Phone: +51 1 411 0600 Anx.204+51 1 265 0759 / +51 1 98911 7300 jalcantara@dentimport.com.pe Dominican Republic Idemefa Calle Pedro A Bobea, Esq. Primera, Bella Vista Santo Domingo Phone: +1 809 535 2585 idemefa@codetel.net.do
Thailand Integrated Dental Equipment54 Soi Phanit Anan, Sukumvit 71 RoadKlongton Nua, Wattana – BangkokPhone: 66 2713 3355 / 668 9798 7199jareeporn@ide.co.th
Venezuela Dental El Bosque Av. Universitaria Resd Diamante Local P.B. Valle Abajo - Caracas Phone: +58 212 6614280 / 6617790 / 6619497 implantesneodent@gmail.com
www.neodent.com.br
top related