proliferation of pots

Post on 01-Jan-2016

33 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

DESCRIPTION

Proliferation of Pots. In late 80’s there were UA8 Roman pots and temporary CDF pots (total cross section) Since then ZEUS LPS has been very successful H1 FPS less succesful due to acceptance, but VFPS planned . E811 (total cross section) CDF (1 spectrometer) end of Run I and Run II - PowerPoint PPT Presentation

TRANSCRIPT

Proliferation of Pots

In late 80’s there were UA8 Roman pots andtemporary CDF pots (total cross section)

Since then ZEUS LPS has been very successfulH1 FPS less succesful due to acceptance, butVFPS planned.

E811 (total cross section)

CDF (1 spectrometer) end of Run I and Run II

DØ FPD Run II

PP2PP (RHIC elastic scattering)

LHC: CMS, TOTEM, ATLAS

DØ Forward Proton Detector

Q4D SQ3S

A1A2

P1UP

p p

Z(m)

D1

Detector

Bel

low

s

Roman Pot

233359 3323057

P2OUT

Q2

P1DN P2IND2Q4 Q3 Q2

Series of 18 Roman Pots forms 9 independentmomentum spectrometers allowing measurementof proton momentum and angle.

1 Dipole Spectrometer ( ) min

8 Quadrupole Spectrometers (p or , up or down,

in or out) t > tmin

pp

Diffraction Thesis Topics

Soft Diffraction and Elastic Scattering: Inclusive Single Diffraction

Elastic scattering (t dependence)

Total Cross Section

Centauro Search

Inclusive double pomeron

Search for glueballs/exotics

Hard Diffraction: Diffractive jet

Diffractive b,c

Diffractive W/Z

Diffractive photon

Diffractive top

Diffractive Higgs

Other hard diffractive topics

Double Pomeron + jets

Other Hard Double Pomeron topics

Rapidity Gaps: Central gaps+jets

Gap tags vs. proton tags

Double pomeron with gaps

E

<100 events in Run I, >1000tagged events in Run II

All 6 castles with 18 Roman pots comprising the FPD were constructed in Brazil, installed in the Tevatron in fall of 2000, and have been functioning as designed.

Quadrupole castle A2 installed in the beam line.

Castle Status

At the University of Texas, Arlington (UTA), scintillating and optical fibers were spliced and inserted into the detector frames.

Detector Assembly

Event DisplayP1D P2D

beam beam

x1xp16 v1

vp20

up1

u20

X –view (above) Y - view

x1

Data Elastic x,y Correlations

PD1x vs. PD2x (mm)

PD1y vs. PD2y (mm)

Good correlation between x1,x2 and y1,y2 in data but shifted from MC expectation (3 mm in x and 1 mm in y)

Elastic ,t (calibrated)

Minimum t about 1.0 Gev2

peak reasonably Gaussian, still 2x ideal MC resolution

Calibrated now peaks at 0

FPD Goals for 2002

• Finish commissioning Phase I of FPD

(10 pots/5 spectrometers)

• Become fully integrated with DØ

• Start with diffractive jets and double

pomeron studies

top related