property details - mackay council · pdf filemeterbox, taps, ac odu, watertank, gas bottles...

Post on 19-Mar-2018

217 Views

Category:

Documents

4 Downloads

Preview:

Click to see full reader

TRANSCRIPT

PROPOSED RESIDENCEPAD RL = 8.000

GROUND FFL = 8.300FIRST FLOOR = 11.190

PROPOSEDDRIVEWAY

27.8m²

4390 OMP

4990 WALL

SEWER MAINAPPROX'

123° 47' 20"

22.692

303° 47' 20"

22.692

G I L

L A

N S

T R

E E

T

33°

45' 00"

(18.0

00)

33°

45' 00"

(18.0

00)

CROSSOVERTo Local Shire Council's

Requirements16.5m²

2300 O

MP

2600

WA

LL

2000 O

MP

2600

WA

LL

5400 OMP

6000 GARAGE WALL

2235 OMP

3730 OMP FF

4330 WALL FF

DP

DP

DP

DP DP DP

DPS

DPS

DP

DPS

MB

408 m²

Lot 21 5800 O

MP

FF

6400 W

ALL F

F

EXISTING DOUBLEGARAGE

33°

45' 00"

39.9

72

303° 47' 20"

22.692

123° 46' 40"

18.668

33°

45' 00"

35.9

49

345° 45' 50"

5.691

123° 47' 20"

22.692

EXISTINGRESIDENCE

M I L N E L A N E

G I L

L A

N S

T R

E E

T

33°

45' 00"

(18.0

00)

33°

45' 00"

(18.0

00)

OVERHEADELECTRICAL

N

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALL TIMES.REFER ANY ENQUIRES TO BUILDINGCONTRACTOR. ALL DIMENSIONS TO BEVERIFIED ON SITE PRIOR TOCONSTRUCTION. ALL WORK TO COMPLYWITH LOCAL AUTHORITY REGULATIONSAND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

PROPERTY DETAILS

As indicated

S & R ALCORN

LOT 21 GILLAN STREETWEST MACKAY QLD 4740

10017.02.16

16 00021

1JW BJC

HOWARD

CARLISLE

408

LOT 21 SP233833PROPOSEDRESIDENCE

Site Plan

LOT LOT 21 SP233833PARISH OF HOWARDCOUNTY OF CARLISLEAREA OF 408m²

WORKING DWG'S

NOTE: STORMWATER DRAINAGE CALCULATED FOR BUILDING ROOF AREAS AND ORPAVED AREAS SHOWN ON THIS PROPOSED DEVELOPMENT ONLY, AND MAY NOT BEADEQUATE FOR ANY SUBSEQUENT ROOF OR PAVED AREAS.MIN 100x75 DOWNPIPES ( EACH TO DRAIN MAX 40.00m SQU ROOF AREA) DISCHARINGINTO 100mm S/W DRAINAGE PIPEWORK (EACH RUN CARRYING MAX CAPACITY OF 8litres/sec) MIN GRADE TO RUBBLE PITS ON SITE TO BE 1%. ALL STORMWATER & DRAINAGETO BE IN COMPLIANCE WITH BCA PARTS 3.1.2 & 3.5.2 AS WELL AS ASNZS3500

NOTE : FINAL POSITIONS OF DOWNPIPES,METERBOX, TAPS, AC ODU, WATERTANK, GASBOTTLES AND HOT WATER SYSTEM, MAYDIFFER TO PLAN DUE TO SITE CONDITIONS.

AREA SCHEDULE

ALFRESCO 18.40 m²

FIRST FLOOR LIVING 86.94 m²

GARAGE 41.74 m²

GROUND FLOOR LIVING 85.31 m²

PORCH 5.67 m²

Grand total 238.07 m²

LEGEND

DP DOWNPIPE

DPS DOWNPIPE WITH SPREADER.To lower roof

MB METER BOX

1 : 200

SITE PLAN LOCALISED1

1 : 250

SITE PLAN OVERALL2

REV DATE DESCRIPTION DRAWN CHECKED

1 17.02.16 CONSTRUCTION DOCUMENTATION JW BJC

PROPOSED RESIDENCELOT 21SITE AREA = 408m²SITE COVERAGE = 37.04%

sarahwe
Received (Auto Date)

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALL TIMES.REFER ANY ENQUIRES TO BUILDINGCONTRACTOR. ALL DIMENSIONS TO BEVERIFIED ON SITE PRIOR TOCONSTRUCTION. ALL WORK TO COMPLYWITH LOCAL AUTHORITY REGULATIONSAND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

S & R ALCORN

LOT 21 GILLAN STREETWEST MACKAY QLD 4740

00208.02.16

16 00021

CBJC NV

HOWARD

CONCEPT

AAA

407m²

Lot LOT 21SP233833

PROPOSEDRESIDENCE

PRELIM - NOT FOR CONSTRUCTIONIllustration of DesignREV DATE DESCRIPTION DRAWN CHECKED

2600

3780

2040

6180

3400

5000 9900 3470 4330

720 CSD820

820

720

2115-SGD

21.4

8PA

NE

L

820

720

720

21.1

2SD

1200

W-21.45 01

W-

18.0

602

W-

18.0

603

W-09.12 04

FR

D17

100

FRD17100

W-18.06 05 W-18.06 06

W-

18.3

007

W-06.15 08

GARAGE

B.PTY

KITCHEN

L'D

RY

ENTRYPORCH

OFFICEPWD

LOUNGE

DINING

ALFRESCO

LIN

EN

LIN

EN

DESK

6000

STORE

4.4x2.61

6.0x6.8

3.0x3.6

4.38x4.73

4.4x2.69

1.65x2.26

5.57x4.9

5570 2230

4900

2000

N

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

1 : 100

S & R ALCORN

LOT 21 GILLAN STREETWEST MACKAY QLD 4740

20008.02.16

16 00021

CBJC NV

HOWARD

CONCEPT

AAA

407

LOT 21SP233833

PROPOSEDRESIDENCE

PRELIM - NOT FOR CONSTRUCTIONFloor Plan - GF

WINDOW SCHEDULE

No. Type Height Width Family

01 21.45 2100 450 Double Hung X

02 18.06 1800 610 Double Hung X

03 18.06 1800 610 Double Hung X

04 09.12 900 1210 Sliding Window - XO

05 18.06 1800 610 Double Hung X

06 18.06 1800 610 Double Hung X

07 18.30 1800 3010 Sliding Window - XOX-OOO

08 06.15 600 1510 Fixed Glass - O

09 09.06 900 610 Sliding Window - XO

10 06.09 600 910 Sliding Window - XO

11 12.12 1200 1210 Sliding Window - XO

12 09.21 900 2110 Sliding Window - XOX

13 12.06 1200 610 Double Hung X

14 12.06 1200 610 Double Hung X

15 09.21 900 2110 Sliding Window - XOX

16 18.21 1800 2110 Sliding Window - XO-OO

17 12.15 1200 1510 Sliding Window - XO

18 06.18 600 1810 Sliding Window - XO

19 06.18 600 1810 Sliding Window - XO

20 10.15 1000 1510 Double Hung XX

AREA SCHEDULE

ALFRESCO 18.40 m²

FIRST FLOOR LIVING 86.94 m²

GARAGE 41.74 m²

GROUND FLOOR LIVING 85.31 m²

PORCH 5.67 m²

Grand total 238.07 m²

LEGEND

NOTES :- FINAL POSITIONS OF DOWNPIPES, METERBOX, TAPS, AC ODU,WATERTANK, GAS BOTTLES AND HOT WATER SYSTEM, MAY DIFFERTO PLAN DUE TO SITE CONDITIONS.- LIFT OFF HINGES TO WC DOOR- SARKING TO ROOF- R1.5 INSULATION TO CEILINGS- ALL SHOWER ROSES TO BE AAA RATED- WATER PRESSURE LIMITED TO 500 KPA AT THE METER- ROOMS WITH NO NATURAL VENTILATION TO HAVE MECHANICALVENTILATION INSTALLED- PROVIDE WATER AND POWER PROVISION TO DISHWASHER SPACE- WINDOW, SGD & INTERNAL DOOR SIZES ARE NOMINAL ONLY & TOBE CONFIRMED WITH MANUFACTURER

820 820

820

720

720

720 720

770

21.18SD21.18SD

W-

09.0

609

W-06.09 10 W-12.12 11

W-

09.2

112

W-

12.0

613

W-

12.0

614

W-09.21 15

W-

18.2

116

W-

12.1

517

W-06.18 18 W-06.18 19

LIN

ENBED 4

WC

BATH WIREN'S

VOID

BED 2 BED 3

BED 1

W-

10.1

520

3.4x3.9

3.0x3.03.0x3.0

3.0x3.0

820

21.1

8SD

N

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALLTIMES. REFER ANY ENQUIRES TOBUILDING CONTRACTOR. ALLDIMENSIONS TO BE VERIFIED ON SITEPRIOR TO CONSTRUCTION. ALL WORKTO COMPLY WITH LOCAL AUTHORITYREGULATIONS AND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

1 : 100

S & R ALCORN

LOT 21 GILLAN STREETWEST MACKAY QLD 4740

20108.02.16

16 00021

CBJC NV

HOWARD

CONCEPT

AAA

407

LOT 21SP233833

PROPOSEDRESIDENCE

PRELIM - NOT FOR CONSTRUCTIONFloor Plan - FF

WINDOW SCHEDULE

No. Type Height Width Family

01 21.45 2100 450 Double Hung X

02 18.06 1800 610 Double Hung X

03 18.06 1800 610 Double Hung X

04 09.12 900 1210 Sliding Window - XO

05 18.06 1800 610 Double Hung X

06 18.06 1800 610 Double Hung X

07 18.30 1800 3010 Sliding Window - XOX-OOO

08 06.15 600 1510 Fixed Glass - O

09 09.06 900 610 Sliding Window - XO

10 06.09 600 910 Sliding Window - XO

11 12.12 1200 1210 Sliding Window - XO

12 09.21 900 2110 Sliding Window - XOX

13 12.06 1200 610 Double Hung X

14 12.06 1200 610 Double Hung X

15 09.21 900 2110 Sliding Window - XOX

16 18.21 1800 2110 Sliding Window - XO-OO

17 12.15 1200 1510 Sliding Window - XO

18 06.18 600 1810 Sliding Window - XO

19 06.18 600 1810 Sliding Window - XO

20 10.15 1000 1510 Double Hung XX

AREA SCHEDULE

ALFRESCO 18.40 m²

FIRST FLOOR LIVING 86.94 m²

GARAGE 41.74 m²

GROUND FLOOR LIVING 85.31 m²

PORCH 5.67 m²

Grand total 238.07 m²

LEGEND

NOTES :- FINAL POSITIONS OF DOWNPIPES, METERBOX, TAPS, AC ODU,WATERTANK, GAS BOTTLES AND HOT WATER SYSTEM, MAY DIFFERTO PLAN DUE TO SITE CONDITIONS.- LIFT OFF HINGES TO WC DOOR- SARKING TO ROOF- R1.5 INSULATION TO CEILINGS- ALL SHOWER ROSES TO BE AAA RATED- WATER PRESSURE LIMITED TO 500 KPA AT THE METER- ROOMS WITH NO NATURAL VENTILATION TO HAVE MECHANICALVENTILATION INSTALLED- PROVIDE WATER AND POWER PROVISION TO DISHWASHER SPACE- WINDOW, SGD & INTERNAL DOOR SIZES ARE NOMINAL ONLY & TOBE CONFIRMED WITH MANUFACTURER

Ground Floor0

GF Ceiling2590

FF Ceiling5330

First Floor2890

Ground Floor0

GF Ceiling2590

FF Ceiling5330

First Floor2890

2440

300

2590

Ground Floor0

GF Ceiling2590

FF Ceiling5330

First Floor2890

Ground Floor0

GF Ceiling2590

FF Ceiling5330

First Floor2890

DWG NO:

SCALE:

DATE:

JOB NO:

ISSUE:

JOB ADDRESS:

CHECKED:DRAWN:CLIENT:

S.P:

PARISH:

COUNTY:

LAND AREA:

PROPERTY DETAILS

USE FIGURED DIMENSIONS AT ALL TIMES.REFER ANY ENQUIRES TO BUILDINGCONTRACTOR. ALL DIMENSIONS TO BEVERIFIED ON SITE PRIOR TOCONSTRUCTION. ALL WORK TO COMPLYWITH LOCAL AUTHORITY REGULATIONSAND BCA.

STAGED PLAN:DESIGN:

CLIENTS SIGNATURE:___________________________________CLIENTS SIGNATURE:________________________________________

1 : 100

S & R ALCORN

LOT 21 GILLAN STREETWEST MACKAY QLD 4740

30008.02.16

16 00021

CBJC NV

HOWARD

CONCEPT

AAA

407m²

Lot LOT 21SP233833

PROPOSEDRESIDENCE

PRELIM - NOT FOR CONSTRUCTIONElevations

1 : 100

FRONT ELEVATION1

1 : 100

REAR ELEVATION2

LEGEND

REV DATE DESCRIPTION DRAWN CHECKED

A xx.xx.xxxx SCHEMATIC DESIGN MN BJC

1 : 100

RIGHT ELEVATION3

1 : 100

LEFT ELEVATION4