protector series standby generators protector features revolving field heavy duty generator directly...
Post on 27-Apr-2020
7 Views
Preview:
TRANSCRIPT
1 of 11
INCLUDES:
• Two-Line LCD Multilingual Digital Evolution™ Controller (English/Spanish/French/Portuguese) with external viewing window for easy indication of generator status and breaker position.
• Capability to be installed with 18" (457mm) of a building*
• True Power™ Electrical Technology
• Isochronous Electronic Governor
• Sound Attenuated Enclosure
• Closed Coolant Recovery System
• Smart Battery Charger
• UV/Ozone Resistant Hoses
• ±1% Voltage Regulation
• Natural Gas or LP Operation
• 5 Year Limited Warranty
• UL 2200 Listed
Note: 25-45 kW units are field convertible between natural gas or liquid propane. 60 kW units are built per fuel requirement and are not convertible.
Standby Power Rating
Model RG025 (Aluminum - Bisque) - 25 kW 60 HzModel RG030 (Aluminum - Bisque) - 30 kW 60 HzModel RG036 (Aluminum - Bisque) - 36 kW 60 HzModel RG045 (Aluminum - Bisque) - 45 kW 60 HzModel RG060 (Aluminum - Bisque) - 60 kW 60 Hz
PROTECTOR® SERIESStandby Generators
Liquid-Cooled Gaseous Engine
Pro
tect
or® S
erie
s
Protector® Series
Meets EPA Emission Regulations25, 30 & 45 kW CA/MA emissions compliant
36 & 60 kW not for sale in CA / MA
¡ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.
¡ TEST CRITERIA: a PROTOTYPE TESTED a NEMA MG1-22 EVALUATION a SYSTEM TORSIONAL TESTED a MOTOR STARTING ABILITY
¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%.
¡ SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.
¡ GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.
FEATURES
*Assembled in the USA using domestic and foreign parts
ISO9001:2008
*Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes. Applicable for 25kW and 30kW units only.
2 of 11
25 • 30 • 36 • 45 • 60 kW application & engineering data
GENERATOR SPECIFICATIONSType Synchronous
Rotor Insulation Class H
Stator Insulation Class H
Telephone Interference Factor (TIF) <50
Alternator Output Leads 1-Phase 4 wire
Alternator Output Leads 3-Phase 6 wire
Bearings Sealed Ball
Coupling Flexible Disc
Excitation System Direct
VOLTAGE REGULATIONType Electronic
Sensing Single Phase
Regulation ± 1%
GOVERNOR SPECIFICATIONSType Electronic
Frequency Regulation Isochronous
Steady State Regulation ± 0.25%
ELECTRICAL SYSTEM
Battery Charge Alternator12 Volt 15 Amp - 25 & 30 kW
12 Volt 30 Amp - 36, 45 & 60 kW
Static Battery Charger 2 Amp
Recommended Battery (battery not included) Group 26, 525CCA
System Voltage 12 Volts
GENERATOR FEATURESRevolving field heavy duty generatorDirectly connected to the engineOperating temperature rise 120 °C above a 40 °C ambientClass H insulation is NEMA ratedAll models fully prototyped tested
ENCLOSURE FEATURES
Aluminum weather protective enclosure
Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability.
Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
Small, compact, attractive Makes for an easy, eye appealing installation.
SAE Sound attenuated enclosure ensures quiet operation.
ENGINE SPECIFICATIONS: 25 & 30 kWMake Generac
Model In-line
Cylinders 4
Displacement (Liters) 1.5
Bore (in/mm) 3.05/77.4
Stroke (in/mm) 3.13/79.5
Compression Ratio 11:1
Intake Air System Naturally Aspirated
Lifter Type Hydraulic
ENGINE SPECIFICATIONS: 36, 45 & 60 kWMake Generac
Model In-line
Cylinders 4
Displacement (Liters) 2.4
Bore (in/mm) 3.41/86.5
Stroke (in/mm) 3.94/100
Compression Ratio 9.5:1
Intake Air SystemNaturally Aspirated (36 & 45 kW) or
Turbocharged/Aftercooled (60 kW)
Lifter Type Hydraulic
ENGINE LUBRICATION SYSTEMOil Pump Type Gear
Oil Filter Type Full flow spin-on cartridge
Crankcase Capacity (qt/l)4/3.8 - 25, 30, 36 & 45 kW
5.25/4.96 - 60 kW
ENGINE COOLING SYSTEMType Closed
Water Pump Belt driven
Fan Speed (rpm)
2484 - 25 & 30 kW
1865 - 36 & 45 kW
2100 - 60 kW
Fan Diameter (in/mm)17.7/449.6 (25 & 30 kW) or
22/558.8 (36, 45 & 60 kW)
Fan ModePusher (25 & 30 kW) or
Puller (36, 45 & 60 kW)
FUEL SYSTEMFuel Type Natural gas, propane vapor
Carburetor Down Draft
Secondary Fuel Regulator Standard
Fuel Shut Off Solenoid Standard
Operating Fuel Pressure 5-14" water column/9-26 mm HG
LP Fuel Pressure 11 - 14" Water Column
NG Fuel Pressure 5 - 14" Water Column(All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271)
Pro
tect
or® S
erie
s
3 of 11
25 • 30 • 36 • 45 • 60 kW operating data
GENERATOR OUTPUT VOLTAGE/kW - 60 HzkW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both)
RG025
120/240 V, 1Ø, 1.0 pf 25 104 25 104 125
120/208 V, 3Ø, 0.8 pf 25 87 25 87 100
120/240 V, 3Ø, 0.8 pf 25 75 25 75 90
RG030
120/240 V, 1Ø, 1.0 pf 30 125 30 125 150
120/208 V, 3Ø, 0.8 pf 30 104 30 104 125
120/240 V, 3Ø, 0.8 pf 30 90 30 90 100
RG036
120/240 V, 1Ø, 1.0 pf 36 150 36 150 175
120/208 V, 3Ø, 0.8 pf 36 125 36 125 150
120/240 V, 3Ø, 0.8 pf 36 108 36 108 125
277/480 V, 3Ø, 0.8 pf 36 54 36 54 60
RG045
120/240 V, 1Ø, 1.0 pf 45 188 45 188 200
120/208 V, 3Ø, 0.8 pf 45 156 45 156 175
120/240 V, 3Ø, 0.8 pf 45 135 45 135 150
277/480 V, 3Ø, 0.8 pf 45 68 45 68 80
RG060
120/240 V, 1Ø, 1.0 pf 60 250 60 250 300
120/208 V, 3Ø, 0.8 pf 60 208 60 208 250
120/240 V, 3Ø, 0.8 pf 60 180 60 180 200
277/480 V, 3Ø, 0.8 pf 60 90 60 90 100
SURGE CAPACITY IN AMPSVoltage Dip @ < .4 pf
15% 30%
RG025
120/240 V, 1Ø 65 170
120/208 V, 3Ø 80 130
120/240 V, 3Ø 69 112
RG030
120/240 V, 1Ø 75 180
120/208 V, 3Ø 96 155
120/240 V, 3Ø 83 134
RG036
120/240 V, 1Ø 105 240
120/208 V, 3Ø 44 130
120/240 V, 3Ø 38 115
277/480 V, 3Ø 20 60
RG045
120/240 V, 1Ø 105 240
120/208 V, 3Ø 44 130
120/240 V, 3Ø 38 115
277/480 V, 3Ø 20 60
RG060
120/240 V, 1Ø 140 320
120/208 V, 3Ø 70 210
120/240 V, 3Ø 61 182
277/480 V, 3Ø 30 91
ENGINE FUEL CONSUMPTIONNatural Gas Propane
(ft³/hr) (m³ /hr) (gal/hr) (l/hr) (ft³/hr)
RG025
Exercise cycle 60 1.7 0.7 2.5 24
25% of rated load 220 6.3 2.9 9.1 88
50% of rated load 297 8.4 3.3 12.3 119
75% of rated load 362 10.3 4 15 145
100% of rated load 430 12.2 4.7 17.8 172
RG030
Exercise cycle 60 1.7 0.7 2.5 24
25% of rated load 240 6.8 2.6 10 96
50% of rated load 320 9.1 3.5 13.3 128
75% of rated load 400 11.4 4.4 16.6 160
100% of rated load 492 14 5.4 20.4 197
RG036
Exercise cycle 65 1.8 0.7 2.6 25
25% of rated load 210 6 2.3 8.6 83
50% of rated load 380 10.8 4.2 15.7 151
75% of rated load 545 15.5 5.9 22.4 216
100% of rated load 730 20.7 8 30.1 290
RG045
Exercise cycle 65 1.8 0.7 2.6 25
25% of rated load 210 6 2.3 8.6 83
50% of rated load 380 10.8 4.2 15.7 151
75% of rated load 545 15.5 5.9 22.4 216
100% of rated load 730 20.7 8 30.1 290
RG060
Exercise cycle 123 3.5 1.34 5.1 49.3
25% of rated load 267 7.6 2.7 10.5 101
50% of rated load 483 13.7 5 19 183
75% of rated load 672 19.1 7 26.5 255
100% of rated load 862 24.5 9 33.9 327
Pro
tect
or® S
erie
s
STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.
Note: Fuel pipe must be sized for full load.
For Btu content, multiply ft³/hr x 2520 (LP) or ft³/hr x 1000 (NG)
For megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG)
Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes.
4 of 11
25 • 30 • 36 • 45 • 60 kW operating data
Pro
tect
or® S
erie
s
POWER ADJUSTMENT FOR AMBIENT CONDITIONS
Temperature Deration ...........................................................................................................3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °FAltitude Deration (25, 30, 36 & 45 kW) ...............................................................................1% for every 100 m above 183 m or 3% for every 1000 ft above 600 ftAltitude Deration (60 kW) ................................................................................................ 1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft
CONTROLLER FEATURES
Two-Line Plain Text LCD Display ....................................................................................................................................Simple user interface for ease of operation.Mode Switch: Auto ..............................................................................................................................................Automatic Start on Utility failure. 7 day exerciser
Off ...........................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual ......................................................................................... Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Programmable start delay between 10-30 seconds .................................................................................................................................................10 sec StandardEngine Start Sequence ..................................................................................................................... Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)Engine Warm-up ..................................................................................................................................................................................................................... 5 secEngine Cool-Down ..................................................................................................................................................................................................................1 minStarter Lock-out ................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped.Smart Battery Charger ........................................................................................................................................................................................................ StandardAutomatic Voltage Regulation with Over and Under Voltage Protection ................................................................................................................................ StandardAutomatic Low Oil Pressure Shutdown ............................................................................................................................................................................... StandardOverspeed Shutdown .............................................................................................................................................................................................. Standard, 72 HzHigh Temperature Shutdown ............................................................................................................................................................................................... StandardOvercrank Protection .......................................................................................................................................................................................................... StandardSafety Fused ...................................................................................................................................................................................................................... StandardFailure to Transfer Protection .............................................................................................................................................................................................. StandardLow Battery Protection ........................................................................................................................................................................................................ Standard50 Event Run Log ............................................................................................................................................................................................................... StandardFuture Set Capable Exerciser .............................................................................................................................................................................................. StandardIncorrect Wiring Protection ................................................................................................................................................................................................. StandardInternal Fault Protection ..................................................................................................................................................................................................... StandardCommon External Fault Capability ...................................................................................................................................................................................... StandardGovernor Failure Protection ................................................................................................................................................................................................ Standard
ENGINE COOLING
25 kW 30 kW 36 kW 45 kW 60 kW
Air flow (inlet air including alternator and combustion air in cfm/cmm) 2490/70.5 2490/70.5 2725/77.2 2725/77.2 3280/92.9
System coolant capacity (gal/liters) 2/7.6 2/7.6 2.5/9.5 2.5/9.5 2.5/9.5
Heat rejection to coolant (BTU per hr/MJ per hr) 112,000/118.2 135,000/142.4 193,000/203.6 193,000/203.6 270,000/284.9
Maximum operation air temperature on radiator (°C/°F) 60/140
Maximum ambient temperature (°C/°F) 50/122
COMBUSTION REQUIREMENTS
Flow at rated power (cfm/cmm) 62/1.8 72/2 144/4.1 144/4.1 180/5.1
SOUND EMISSIONS
Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* 59 59 61 61 65
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load* 72 73 70 73 72
*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.
EXHAUST
Exhaust flow at rated output (cfm/cmm) 203/5.7 237/6.7 300/8.5 420/11.9 494/14
Exhaust temperature at muffler outlet (°C/°F) 593/1100 610/1130 579/1075 593/1100 566/1050
ENGINE PARAMETERS
Rated Synchronous rpm 3600
5 of 11
25 • 30 • 36 • 45 • 60 kW available accessories
Pro
tect
or® S
erie
s
Model # Product Description
G006463-4 Mobile Link™
Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator’s status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only.
G006478-0 Harness Adapter KitThe Harness Adapter Kit is required to make liquid-cooled units compatible with Mobile Link™.
G006175-0 - 25 & 30 kW
G005630-1 - 36, 45 & 60 kWCold Weather Kit
If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap.
G006174-0 - 25 & 30 kW
G005616-0 - 36, 45 & 60 kWExtreme Cold Weather Kit
Recommended where the temperature regularly falls below 32 °F (0 °C) for extended periods of time. For liquid cooled units only.
G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris.
G005703-0 - Bisque Paint KitIf the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure.
G006176-0 - 25 & 30 kW
G006172-0 - 36 & 45 kW
G006171-0 - 60 kW
Scheduled Maintenance Kit
The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform complete maintenance on Generac liquid-cooled generators.
G006664-0Local Wireless Monitor
Completely wireless and battery powered, Generac's wireless remote monitor provides you with instant status information without ever going outside.
G006665-0Wireless Remote Extension Harness
Recommended for use with the Wireless Remote on units up to 60 kW, required for use on units 70 kW or greater.
G006873-0Smart Management Module (50 Amps)
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management flexibility not found in any other power management system.
G006510-0 E-StopE-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency.
G007005-0Wi-Fi LP Fuel LevelMonitor
The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank’s fuel level is an important step in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill.
6 of 11
25 & 30 kW installation layout
Pro
tect
or® S
erie
s
Drawing #0K8420-B (1 of 2)
1490
[58.
7] T
YP
48 [1.9
]TY
P
980
[38.
6]O
VE
RA
LLH
EIG
HT
44[1
.7]
631
[24.
8]D
OO
R T
YP
665.
5 [2
6.2"
]C
EN
TER
OF
GR
AV
ITY
(SE
E N
OTE
5)
45 [1.8
]TY
P
780
[30.
7]77
6[3
0.6]
OV
ER
ALL
WID
TH
1580
[62.
2]O
VE
RA
LL L
EN
GTH
SE
RV
ICE
ITE
M1.
5L
OIL
FIL
L C
AP
EIT
HE
R D
OO
R
OIL
DIP
STI
CK
RIG
HT
DO
OR
O
IL F
ILTE
RR
IGH
T D
OO
RO
IL D
RA
IN H
OS
ER
IGH
T D
OO
RR
AD
IATO
R D
RA
IN H
OS
ER
IGH
T D
OO
RA
IR C
LEA
NE
R E
LEM
EN
TR
IGH
T D
OO
RS
PA
RK
PLU
GS
RIG
HT
DO
OR
MU
FFLE
RS
EE
NO
TE 1
2FA
N B
ELT
EIT
HE
R D
OO
RB
ATT
ER
YR
IGH
T D
OO
R
WE
IGH
T D
ATA
EN
GIN
E/K
WE
NC
LOS
UR
EM
ATE
RIA
L
WE
IGH
TG
EN
SE
T O
NLY
KG
[LB
S]
WE
IGH
T S
HIP
PIN
G S
KID
KG
[LB
S]
SH
IPP
ING
WE
IGH
TK
G [L
BS
]
1.5L
/25K
WS
T39
2 [8
65]
30 [6
6]42
2 [9
31]
1.5L
/30K
WS
T40
6 [8
95]
30 [6
6]43
6 [9
61]
1.5L
/25K
WA
L35
2 [7
77]
30 [6
6]38
2 [8
43]
1.5L
/30K
WA
L36
6 [8
07]
30 [6
6]39
6 [8
73]
RE
AR
EN
CLO
SU
RE
CO
VE
R P
AN
EL
SE
E N
OTE
4
CU
STO
ME
R A
CC
ES
SA
SS
EM
BLY
, CO
NTR
OL
PA
NE
L A
CC
ES
S,
BA
TTE
RY
CH
AR
GE
RLO
CA
TED
WIT
HIN
SE
E N
OTE
4
NO
TES
: 1.
MIN
IMU
M R
EC
OM
ME
ND
ED
CO
NC
RE
TE P
AD
SIZ
E: 1
092
(43"
) WID
E X
188
7 (7
4.3"
) LO
NG
. R
EFE
RE
NC
E IN
STA
LLA
TIO
N G
UID
E S
UP
PLI
ED
WIT
H U
NIT
FO
R C
ON
CR
ETE
PA
D G
UID
ELI
NE
S.
2. A
LLO
W S
UFF
ICIE
NT
RO
OM
ON
ALL
SID
ES
OF
THE
GE
NE
RA
TOR
FO
R M
AIN
TEN
AN
CE
AN
D S
ER
VIC
ING
. TH
IS U
NIT
MU
ST
BE
INS
TALL
ED
IN A
CC
OR
DA
NC
E W
ITH
CU
RR
EN
T A
PP
LIC
AB
LE N
FPA
37
AN
D N
FPA
70
STA
ND
AR
DS
AS
WE
LL A
S A
NY
OTH
ER
FE
DE
RA
L, S
TATE
, AN
D L
OC
AL
CO
DE
S.
3. C
ON
TRO
L P
AN
EL
/ CIR
CU
IT B
RE
AK
ER
INFO
RM
ATI
ON
: -
SE
E S
PE
CIF
ICA
TIO
N S
HE
ET
OR
OW
NE
RS
MA
NU
AL
- A
CC
ES
SIB
LE T
HR
OU
GH
CU
STO
ME
R A
CC
ES
S A
SS
EM
BLY
DO
OR
ON
RE
AR
OF
GE
NE
RA
TOR
.4.
RE
MO
VE
TH
E R
EA
R E
NC
LOS
UR
E C
OV
ER
PA
NE
L TO
AC
CE
SS
TH
E S
TUB
-UP
AR
EA
S A
S F
OLL
OW
S:
- H
IGH
VO
LTA
GE
CO
NN
EC
TIO
N IN
CLU
DIN
G A
C L
OA
D L
EA
D C
ON
DU
IT C
ON
NE
CTI
ON
N
EU
TRA
L C
ON
NE
CTI
ON
, BA
TTE
RY
CH
AR
GE
R 1
20 V
OLT
AC
(0.5
AM
P M
AX
) CO
NN
EC
TIO
N.
- L
OW
VO
LTA
GE
CO
NN
EC
TIO
N IN
CLU
DIN
G T
RA
NS
FER
SW
ITC
H C
ON
TRO
L W
IRE
S.
5. C
EN
TER
OF
GR
AV
ITY
AN
D W
EIG
HT
MA
Y C
HA
NG
E D
UE
TO
UN
IT O
PTI
ON
S.
6. B
OTT
OM
OF
GE
NE
RA
TOR
SE
T M
US
T B
E E
NC
LOS
ED
TO
PR
EV
EN
T P
ES
T IN
TRU
SIO
N A
ND
RE
CIR
CU
LATI
ON
OF
DIS
CH
AR
GE
AIR
AN
D/O
R IM
PR
OP
ER
CO
OLI
NG
AIR
FLO
W.
7. E
XH
AU
ST
SY
STE
M M
AX
IMU
M B
AC
K P
RE
SS
UR
E: 2
4 IN
CH
ES
H2O
.8.
RE
FER
EN
CE
OW
NE
RS
MA
NU
AL
FOR
LIF
TIN
G W
AR
NIN
GS
.9.
MO
UN
TIN
G B
OLT
S O
R S
TUD
S T
O M
OU
NTI
NG
SU
RFA
CE
SH
ALL
BE
5/8
-11
GR
AD
E 5
(U
SE
STA
ND
AR
D S
AE
TO
RQ
UE
SP
EC
S)
10. M
US
T A
LLO
W F
RE
E F
LOW
OF
INTA
KE
AIR
, DIS
CH
AR
GE
AIR
AN
D E
XH
AU
ST.
SE
E S
PE
C S
HE
ET
FOR
MIN
IMU
M A
IR F
LOW
AN
D M
AX
IMU
M R
ES
TRIC
TIO
N R
EQ
UIR
EM
EN
TS.
11. G
EN
ER
ATO
R M
US
T B
E IN
STA
LLE
D S
UC
H T
HA
T FR
ES
H C
OO
LIN
G A
IR IS
AV
AIL
AB
LE A
ND
TH
AT
DIS
CH
AR
GE
AIR
FR
OM
RA
DIA
TOR
IS N
OT
RE
CIR
CU
LATE
D.
12. E
XH
AU
ST
MU
FFLE
R E
NC
LOS
ED
WIT
HIN
GE
NE
RA
TOR
EN
CLO
SU
RE
, R
EM
OV
E E
NC
LOS
UR
E T
O A
CC
ES
S E
XH
AU
ST
MU
FFLE
R.
RA
DIA
TOR
/EX
HA
US
TD
ISC
HA
RG
E A
IR(B
OTH
SID
ES
)
AIR
INTA
KE
(BO
TH S
IDE
S)
RE
FER
EN
CE
OW
NE
RS
MA
NU
AL
FOR
PE
RIO
DIC
RE
PLA
CE
ME
NT
PA
RT
LIS
TIN
GS
.
RE
AR
VIE
W
CIR
CU
IT B
RE
AK
ER
SE
E N
OTE
3
RIG
HT
SID
E V
IEW
FUE
L LI
NE
CO
NN
EC
TIO
N3/
4" N
PT
FEM
ALE
CO
UP
LIN
G
VIS
E A
CTI
ON
LA
TCH
,O
NE
PE
R D
OO
R, O
NE
LIF
T-O
FFD
OO
R P
ER
SID
E O
F G
EN
ER
ATO
R.
LEFT
SID
E V
IEW
EX
HA
US
T M
UFF
LER
EN
CLO
SE
D W
ITH
IN
GE
NE
RA
TOR
EN
CLO
SU
RE
LIFT
ING
PR
OV
ISIO
N (4
PLA
CE
S)
SE
E N
OTE
S 5
, 8 A
ND
C
EN
TER
OF
GR
AV
ITY
DIM
EN
SIO
NS
.
RA
DIA
TOR
/EX
HA
US
TD
ISC
HA
RG
E A
IR
TOP
VIE
WR
EM
OV
E C
OV
ER
FOR
AC
CE
SS
TO
RA
DIA
TOR
FIL
L C
AP
BA
TTE
RY
12V
GR
OU
P 2
6N
EG
ATI
VE
GR
OU
ND
P/N
: 077
483
CIR
CU
IT B
RE
AK
ER
NE
UTR
AL
AN
D C
US
TOM
ER
CO
NN
EC
TIO
N O
PE
NIN
G
7 of 11
25 & 30 kW installation layout
Pro
tect
or® S
erie
s
735
[28.
9]
776
[30.
6]
96[3
.8]
723
[28.
5] T
YP
MO
UN
TIN
G S
LOT
CE
NTE
RS
27[1
.0]
TYP
1580
[62.
2]
1345
[53.
0]22
6[8
.9]
100
[3.9
]*S
TUB
-UP
A
RE
A
50 [2.0
] 51 [2
.0]
9 [.4]
104.
5[4
.114
17]
*STU
B-U
P A
RE
A
674
[26.
5]
1380
[54.
3] T
YP
MO
UN
TIN
G S
LOT
CE
NTE
RS
45[1
.8] T
YP
RE
MO
VA
BLE
STU
B-U
P C
OV
ER
* N
OTE
- S
TUB
-UP
AR
EA
FO
R H
IGH
AN
D L
OW
VO
LTA
GE
CO
NN
EC
TIO
NS
.C
IRC
UIT
BR
EA
KE
R, N
EU
TRA
L A
ND
CU
STO
ME
R C
ON
NE
CTI
ON
OP
EN
ING
.
LEFT
SID
E V
IEW
RE
AR
VIE
W
13.5
X 2
9.5
MO
UN
TIN
G S
LOTS
4X
TOP
VIE
W
Drawing #0K8420-B (2 of 2)
8 of 11
36 & 45 kW installation layout
Pro
tect
or® S
erie
s
Drawing #0K8636-B (1 of 2)
758
[29.
8]D
OO
R T
YP
443
[17.
5]
187
[7.4
]
50 [2.0
]10
00[3
9.4]
1170
[46.
1]O
VE
RA
LLH
EIG
HT
888
[35.
0]O
VE
RA
LL W
IDTH
58 [2.3
]TY
P
46.5
[1.8
3]18
57[7
3.1]
TY
P
1950
[76.
8]O
VE
RA
LL L
EN
GTH
749.
3 [2
9.5]
CE
NTE
R O
F G
RA
VIT
Y(S
EE
NO
TE 5
)
SE
RV
ICE
ITE
M2.
4L
OIL
FIL
L C
AP
EIT
HE
R S
IDE
OIL
DIP
STI
CK
RIG
HT
SID
EO
IL F
ILTE
RR
IGH
T S
IDE
OIL
DR
AIN
HO
SE
RIG
HT
SID
ER
AD
IATO
R D
RA
IN H
OS
ELE
FT S
IDE
CO
OLA
NT
RE
CO
VE
RY
BO
TTLE
LEFT
SID
ER
AD
IATO
R F
ILL
CA
PR
OO
F TO
PA
IR C
LEA
NE
R E
LEM
EN
TLE
FT S
IDE
SP
AR
K P
LUG
SLE
FT S
IDE
MU
FFLE
RS
EE
NO
TE 1
1D
RIV
E B
ELT
EIT
HE
R S
IDE
FAN
BE
LTS
EE
NO
TE 1
1B
ATT
ER
YLE
FT S
IDE
LUB
E O
IL M
AIN
TAIN
ER
SU
PP
LY T
AN
K F
ILL
CA
PR
OO
F TO
P
WE
IGH
T D
ATA
EN
GIN
E/K
WE
NC
LOS
UR
EM
ATE
RIA
L
WE
IGH
TG
EN
SE
T O
NLY
KG
[LB
S]
WE
IGH
T S
HIP
PIN
G S
KID
KG
[LB
S]
SH
IPP
ING
WE
IGH
TK
G [L
BS
]
2.4L
36K
WS
T56
9 [1
255]
44 [9
8]61
3 [1
353]
2.4L
36K
WA
L54
5 [1
202]
44 [9
8]59
0 [1
300]
2.4L
45K
WS
T59
6 [1
313]
44 [9
8]64
0 [1
411]
2.4L
45K
WA
L57
2 [1
260]
44 [9
8]61
6 [1
358]
NO
TES
: 1.
MIN
IMU
M R
EC
OM
ME
ND
ED
CO
NC
RE
TE P
AD
SIZ
E: 1
194M
M (4
7") W
IDE
X 2
256M
M (8
8.8"
) LO
NG
. R
EFE
RE
NC
E IN
STA
LLA
TIO
N G
UID
E S
UP
PLI
ED
WIT
H U
NIT
FO
R C
ON
CR
ETE
PA
D G
UID
ELI
NE
S.
2. A
LLO
W S
UFF
ICIE
NT
RO
OM
ON
ALL
SID
ES
OF
THE
GE
NE
RA
TOR
FO
R M
AIN
TEN
AN
CE
AN
D S
ER
VIC
ING
. TH
IS U
NIT
MU
ST
BE
INS
TALL
ED
IN A
CC
OR
DA
NC
E W
ITH
CU
RR
EN
T A
PP
LIC
AB
LE N
FPA
37
AN
D N
FPA
70
STA
ND
AR
DS
AS
WE
LL A
S A
NY
OTH
ER
FE
DE
RA
L, S
TATE
, AN
D L
OC
AL
CO
DE
S.
3. C
ON
TRO
L P
AN
EL
/ CIR
CU
IT B
RE
AK
ER
INFO
RM
ATI
ON
: -
SE
E S
PE
CIF
ICA
TIO
N S
HE
ET
OR
OW
NE
RS
MA
NU
AL
- A
CC
ES
SIB
LE T
HR
OU
GH
CU
STO
ME
R A
CC
ES
S A
SS
EM
BLY
DO
OR
ON
RE
AR
OF
GE
NE
RA
TOR
.4.
RE
MO
VE
TH
E R
EA
R E
NC
LOS
UR
E C
OV
ER
PA
NE
L TO
AC
CE
SS
TH
E S
TUB
-UP
AR
EA
S A
S F
OLL
OW
S:
- H
IGH
VO
LTA
GE
CO
NN
EC
TIO
N IN
CLU
DIN
G A
C L
OA
D L
EA
D C
ON
DU
IT C
ON
NE
CTI
ON
N
EU
TRA
L C
ON
NE
CTI
ON
, BA
TTE
RY
CH
AR
GE
R 1
20 V
OLT
AC
(0.5
AM
P M
AX
) CO
NN
EC
TIO
N.
- L
OW
VO
LTA
GE
CO
NN
EC
TIO
N IN
CLU
DIN
G T
RA
NS
FER
SW
ITC
H C
ON
TRO
L W
IRE
S.
5. C
EN
TER
OF
GR
AV
ITY
AN
D W
EIG
HT
MA
Y C
HA
NG
E D
UE
TO
UN
IT O
PTI
ON
S.
6. B
OTT
OM
OF
GE
NE
RA
TOR
SE
T M
US
T B
E E
NC
LOS
ED
TO
PR
EV
EN
T P
ES
T IN
TRU
SIO
N A
ND
RE
CIR
CU
LATI
ON
OF
DIS
CH
AR
GE
AIR
AN
D/O
R IM
PR
OP
ER
CO
OLI
NG
AIR
FLO
W.
7. R
EFE
RE
NC
E O
WN
ER
S M
AN
UA
L FO
R L
IFTI
NG
WA
RN
ING
S.
8. M
OU
NTI
NG
BO
LTS
OR
STU
DS
TO
MO
UN
TIN
G S
UR
FAC
E S
HA
LL B
E 5
/8-1
1 G
RA
DE
5 (
US
E S
TAN
DA
RD
SA
E T
OR
QU
E S
PE
CS
)9.
MU
ST
ALL
OW
FR
EE
FLO
W O
F IN
TAK
E A
IR, D
ISC
HA
RG
E A
IR A
ND
EX
HA
US
T. S
EE
SP
EC
SH
EE
T FO
R M
INIM
UM
AIR
FLO
W A
ND
MA
XIM
UM
RE
STR
ICTI
ON
RE
QU
IRE
ME
NTS
.10
. GE
NE
RA
TOR
MU
ST
BE
INS
TALL
ED
SU
CH
TH
AT
FRE
SH
CO
OLI
NG
AIR
IS A
VA
ILA
BLE
AN
D T
HA
T D
ISC
HA
RG
E A
IR F
RO
M R
AD
IATO
R IS
NO
T R
EC
IRC
ULA
TED
.11
. EX
HA
US
T M
UFF
LER
AN
D F
AN
BE
LT E
NC
LOS
ED
WIT
HIN
GE
NE
RA
TOR
EN
CLO
SU
RE
, R
EM
OV
E F
RO
NT
PA
NE
L TO
AC
CE
SS
.
RE
FER
EN
CE
OW
NE
RS
MA
NU
AL
FOR
PE
RIO
DIC
RE
PLA
CE
ME
NT
PA
RT
LIS
TIN
GS
.
RA
DIA
TOR
/EX
HA
US
TD
ISC
HA
RG
E A
IRRA
DIA
TOR
/EX
HA
US
TD
ISC
HA
RG
E A
IR(B
OTH
SID
ES
)A
IR IN
TAK
E(B
OTH
SID
ES
)
DIM
EN
SIO
NS
: MM
[IN
CH
]
RE
AR
VIE
W
RE
AR
EN
CLO
SU
RE
CO
VE
R P
AN
EL
SE
E N
OTE
4
CU
STO
ME
R A
CC
ES
SA
SS
EM
BLY
, CO
NTR
OL
PA
NE
L A
CC
ES
S,
BA
TTE
RY
CH
AR
GE
RLO
CA
TED
WIT
HIN
SE
E N
OTE
4
CIR
CU
IT B
RE
AK
ER
SE
E N
OTE
3
VIC
E A
CTI
ON
LA
TCH
,O
NE
PE
R D
OO
R,
ON
E L
IFT
OFF
DO
OR
PE
R S
IDE
OF
GE
NE
RA
TOR
LEFT
SID
E V
IEW
FUE
L LI
NE
CO
NN
EC
TIO
N3/
4" N
PT
FEM
ALE
CO
UP
LIN
G
EX
HA
US
T M
UFF
LER
EN
CLO
SE
D W
ITH
ING
EN
ER
ATO
R E
NC
LOS
UR
E
TOP
VIE
W
RE
MO
VE
CO
VE
RFO
R A
CC
ES
S T
OR
AD
IATO
R F
ILL
CA
P
BA
TTE
RY
12V
GR
OU
P 2
6N
EG
ATI
VE
GR
OU
ND
P/N
: 077
483
RE
MO
VE
CO
VE
R F
OR
AC
CE
SS
TO
LU
BE
OIL
MA
INTA
INE
R S
UP
PLY
TA
NK
RE
FER
EN
CE
OW
NE
RS
MA
NU
AL
-A-
-A-
-A-
9 of 11
36 & 45 kW installation layout
Pro
tect
or® S
erie
s
162
[6.4
]*S
TUB
-UP
AR
EA9 [.4
]51 [2
.0]
786
[30.
9]
162
[6.4
]*S
TUB
-UP
AR
EA
50[2
.0]
TYP
1750
[68.
9] T
YP
MO
UN
TIN
G S
LOT
CE
NTE
RS
1950
[76.
8]
850
[33.
5]
116
[4.6
]
25[1
.0]
TYP
838
[33.
0] T
YP
MO
UN
TIN
G S
LOT
CE
NTE
RS
888
[35.
0]
12[.5
]
217
[8.5
]17
33[6
8.2]
DIM
EN
SIO
NS
: MM
[IN
CH
]*NO
TE -
STU
B-U
P A
RE
A F
OR
HIG
H A
ND
LO
W V
OLT
AG
E C
ON
NE
CTI
ON
S.
CIR
CU
IT B
RE
AK
ER
, NE
UTR
AL
AN
D C
US
TOM
ER
CO
NN
EC
TIO
N O
PE
NIN
GS
.
TOP
VIE
W
13.5
X 2
9.5
MO
UN
TIN
G S
LOTS
4X
LEFT
SID
E V
IEW
RE
AR
VIE
W
RE
MO
VA
BLE
STU
B-U
P C
OV
ER
Drawing #0K8636-B (2 of 2)
10 of 11
Pro
tect
or® S
erie
s
60 kW installation layoutDrawing #0L2090-B (1 of 2)
357
[14.
0]
167
[6.6
]68
3.3
[26.
9]C
EN
TER
OF
GR
AV
ITY
50[2
.0]
1000
[39.
4]
1170
[46.
1]O
VE
RA
LLH
EIG
HT
888
[35.
0]O
VE
RA
LL W
IDTH
58 [2.3
]TY
P
1857
[73.
1]19
50[7
6.8]
OV
ER
ALL
LE
NG
TH
758
[29.
8]D
OO
R T
YP
SE
RV
ICE
ITE
M2.
4L
OIL
FIL
L C
AP
EIT
HE
R S
IDE
OIL
DIP
STI
CK
RIG
HT
SID
EO
IL F
ILTE
RLE
FT S
IDE
OIL
DR
AIN
HO
SE
RIG
HT
SID
ER
AD
IATO
R D
RA
IN H
OS
ELE
FT S
IDE
CO
OLA
NT
RE
CO
VE
RY
BO
TTLE
LEFT
SID
ER
AD
IATO
R F
ILL
CA
PR
OO
F TO
PA
IR C
LEA
NE
R E
LEM
EN
TLE
FT S
IDE
SP
AR
K P
LUG
SLE
FT S
IDE
MU
FFLE
RS
EE
NO
TE 1
1D
RIV
E B
ELT
EIT
HE
R S
IDE
FAN
BE
LTS
EE
NO
TE 1
1B
ATT
ER
YLE
FT S
IDE
LUB
E O
IL M
AIN
TAIN
ER
SU
PP
LY T
AN
K F
ILL
CA
PR
OO
F TO
P
WE
IGH
T D
ATA
EN
GIN
E/K
WE
NC
LOS
UR
EM
ATE
RIA
L
WE
IGH
TG
EN
SE
T O
NLY
KG
[LB
S]
WE
IGH
T S
HIP
PIN
G S
KID
KG
[LB
S]
SH
IPP
ING
WE
IGH
TK
G [L
BS
]
2.4L
60K
WS
T58
2 [1
283]
44 [9
8]62
6 [1
381]
2.4L
60K
WA
L55
8 [1
230]
44 [9
8]60
2 [1
328]
NO
TES
: 1.
MIN
IMU
M R
EC
OM
ME
ND
ED
CO
NC
RE
TE P
AD
SIZ
E: 1
194M
M (4
7") W
IDE
X 2
256M
M (8
8.8"
) LO
NG
. R
EFE
RE
NC
E IN
STA
LLA
TIO
N G
UID
E S
UP
PLI
ED
WIT
H U
NIT
FO
R C
ON
CR
ETE
PA
D G
UID
ELI
NE
S.
2. A
LLO
W S
UFF
ICIE
NT
RO
OM
ON
ALL
SID
ES
OF
THE
GE
NE
RA
TOR
FO
R M
AIN
TEN
AN
CE
AN
D S
ER
VIC
ING
. TH
IS U
NIT
MU
ST
BE
INS
TALL
ED
IN A
CC
OR
DA
NC
E W
ITH
CU
RR
EN
T A
PP
LIC
AB
LE N
FPA
37
AN
D N
FPA
70
STA
ND
AR
DS
AS
WE
LL A
S A
NY
OTH
ER
FE
DE
RA
L, S
TATE
, AN
D L
OC
AL
CO
DE
S.
3. C
ON
TRO
L P
AN
EL
/ CIR
CU
IT B
RE
AK
ER
INFO
RM
ATI
ON
: -
SE
E S
PE
CIF
ICA
TIO
N S
HE
ET
OR
OW
NE
RS
MA
NU
AL
- A
CC
ES
SIB
LE T
HR
OU
GH
CU
STO
ME
R A
CC
ES
S A
SS
EM
BLY
DO
OR
ON
RE
AR
OF
GE
NE
RA
TOR
.4.
RE
MO
VE
TH
E R
EA
R E
NC
LOS
UR
E C
OV
ER
PA
NE
L TO
AC
CE
SS
TH
E S
TUB
-UP
AR
EA
S A
S F
OLL
OW
S:
- H
IGH
VO
LTA
GE
CO
NN
EC
TIO
N IN
CLU
DIN
G A
C L
OA
D L
EA
D C
ON
DU
IT C
ON
NE
CTI
ON
N
EU
TRA
L C
ON
NE
CTI
ON
, BA
TTE
RY
CH
AR
GE
R 1
20 V
OLT
AC
(0.5
AM
P M
AX
) CO
NN
EC
TIO
N.
- L
OW
VO
LTA
GE
CO
NN
EC
TIO
N IN
CLU
DIN
G T
RA
NS
FER
SW
ITC
H C
ON
TRO
L W
IRE
S.
5. C
EN
TER
OF
GR
AV
ITY
AN
D W
EIG
HT
MA
Y C
HA
NG
E D
UE
TO
UN
IT O
PTI
ON
S.
6. B
OTT
OM
OF
GE
NE
RA
TOR
SE
T M
US
T B
E E
NC
LOS
ED
TO
PR
EV
EN
T P
ES
T IN
TRU
SIO
N A
ND
RE
CIR
CU
LATI
ON
OF
DIS
CH
AR
GE
AIR
AN
D/O
R IM
PR
OP
ER
CO
OLI
NG
AIR
FLO
W.
7. R
EFE
RE
NC
E O
WN
ER
S M
AN
UA
L FO
R L
IFTI
NG
WA
RN
ING
S.
8. M
OU
NTI
NG
BO
LTS
OR
STU
DS
TO
MO
UN
TIN
G S
UR
FAC
E S
HA
LL B
E 5
/8-1
1 G
RA
DE
5 (
US
E S
TAN
DA
RD
SA
E T
OR
QU
E S
PE
CS
)9.
MU
ST
ALL
OW
FR
EE
FLO
W O
F IN
TAK
E A
IR, D
ISC
HA
RG
E A
IR A
ND
EX
HA
US
T. S
EE
SP
EC
SH
EE
T FO
R M
INIM
UM
AIR
FLO
W A
ND
MA
XIM
UM
RE
STR
ICTI
ON
RE
QU
IRE
ME
NTS
.10
. GE
NE
RA
TOR
MU
ST
BE
INS
TALL
ED
SU
CH
TH
AT
FRE
SH
CO
OLI
NG
AIR
IS A
VA
ILA
BLE
AN
D T
HA
T D
ISC
HA
RG
E A
IR F
RO
M R
AD
IATO
R IS
NO
T R
EC
IRC
ULA
TED
.11
. EX
HA
US
T M
UFF
LER
AN
D F
AN
BE
LT E
NC
LOS
ED
WIT
HIN
GE
NE
RA
TOR
EN
CLO
SU
RE
, R
EM
OV
E F
RO
NT
PA
NE
L TO
AC
CE
SS
.
RE
FER
EN
CE
OW
NE
RS
MA
NU
AL
FOR
PE
RIO
DIC
RE
PLA
CE
ME
NT
PA
RT
LIS
TIN
GS
.
RIG
HT
SID
E V
IEW
RE
AR
VIE
WLE
FT S
IDE
VIE
W
TOP
VIE
W
DIM
EN
SIO
NS
: MM
[IN
CH
]
RA
DIA
TOR
/EX
HA
US
TD
ISC
HA
RG
E A
IR
EX
HA
US
T M
UFF
LER
EN
CLO
SE
D W
ITH
ING
EN
ER
ATO
R E
NC
LOS
UR
E
FUE
L LI
NE
CO
NN
EC
TIO
N3/
4" N
PT
FEM
ALE
CO
UP
LIN
G
CIR
CU
IT B
RE
AK
ER
SE
E N
OTE
3
RE
AR
EN
CLO
SU
RE
CO
VE
R P
AN
EL
SE
E N
OTE
4
CU
STO
ME
R A
CC
ES
SA
SS
EM
BLY
, CO
NTR
OL
PA
NE
L A
CC
ES
S,
BA
TTE
RY
CH
AR
GE
RLO
CA
TED
WIT
HIN
SE
E N
OTE
4
VIC
E A
CTI
ON
LA
TCH
,O
NE
PE
R D
OO
R,
ON
E L
IFT
OFF
DO
OR
PE
R S
IDE
OF
GE
NE
RA
TOR
RA
DIA
TOR
/EX
HA
US
TD
ISC
HA
RG
E A
IR(B
OTH
SID
ES
)A
IR IN
TAK
E(B
OTH
SID
ES
)
BA
TTE
RY
12V
GR
OU
P 2
6N
EG
ATI
VE
GR
OU
ND
P/N
: 077
483
RE
MO
VE
CO
VE
RFO
R A
CC
ES
S T
OR
AD
IATO
R F
ILL
CA
P
RE
MO
VE
CO
VE
R F
OR
AC
CE
SS
TO
LU
BE
OIL
MA
INTA
INE
R S
UP
PLY
TA
NK
RE
FER
EN
CE
OW
NE
RS
MA
NU
AL
11 of 11
Pro
tect
or® S
erie
s
60 kW installation layout
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com©2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0L0037SBY-L 9/25/17
1733
[68.
2]
217
[8.5
]
12[.5
]
162
[6.4
]*S
TUB
-UP
AR
EA
9 [.4]
162
[6.4
]*S
TUB
-UP
A
RE
A
51 [2.0
]
786
[30.
9]
1950
[76.
8]
50[2
.0]
TYP
1750
[68.
9] T
YP
MO
UN
TIN
G S
LOT
CE
NTE
RS
25[1
.0]
TYP
838
[33.
0] T
YP
MO
UN
TIN
G S
LOT
CE
NTE
RS
888
[35.
0]
116
[4.6
]
850
[33.
5]
DIM
EN
SIO
NS
: MM
[IN
CH
]
*NO
TE -
STU
B-U
P A
RE
A F
OR
HIG
H A
ND
LO
W V
OLT
AG
E C
ON
NE
CTI
ON
S.
CIR
CU
IT B
RE
AK
ER
, NE
UTR
AL
AN
D C
US
TOM
ER
CO
NN
EC
TIO
N.
LEFT
SID
E V
IEW
13.5
X 2
9.5
MO
UN
TIN
G S
LOTS
4X
TOP
VIE
W
RE
MO
VA
BLE
STU
B-U
P C
OV
ER
RE
AR
VIE
W
Drawing #0L2090-B (2 of 2)
top related