records force & distance. * calibration “strain gauge” * 6 samples * what it means * video *...

Post on 04-Jan-2016

227 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Measuring Tensile StrengthRecords force & distance

* Calibration “strain gauge”

* 6 Samples

* What it Means

* Video

* Results

* Calibration “strain gauge”

* 6 Samples

* What it Means

* Video

* Results

STEE

L

COPPER

BRASS

TITANIUMALUMINUM

DELRIM

* Calibration “strain gauge”

* 6 Samples

* What it Means

* Video

* ResultsDISTANCE STRETCHED

FORC

E

* Calibration “strain gauge”

* 6 Samples

* What it Means

* Video

* ResultsDISTANCE STRETCHED

FORC

E

* Calibration “strain gauge”

* 6 Samples

* What it Means

* Video

* ResultsDISTANCE STRETCHED

FORC

E

* Calibration “strain gauge”

* 6 Samples

* What it Means

* Video

* ResultsDISTANCE STRETCHED

FORC

E

* Calibration “strain gauge”

* 6 Samples

* What it Means

* Video

* Results

* Calibration “strain gauge”

* 6 Samples

* What it Means

* Video

* Results

Physical Properties of Materials• Melting Point• Boiling Point• Density• Heat and Electric Conductance / Resistance• Thermal Expansion• Young’s Modulus / Tensile Strength• Refractive Index• Viscosity• Glass Transition Temperature

Thermogravimeteric Analyzer

• Measures weight loss upon heating, cooling, or when held at a constant temperature.

• The machine is basically a furnace with a microbalancer that is used to characterize materials with regard to their composition.

DSC - Differential Scanning Calorimeter

measures temperatures and heat flows associated with thermal transitions in a material

Glass Transition Temperature - Tg

the temperature at which a solid, such as glass or a polymer,becomes brittle (crystalline) on cooling, or soft (amorphous) on heating

Punching

Filling Pan

Crimping

Cooling

Heating

Cooling

Heating

0.0

0.5

1.0

1.5

2.0

Tan

Del

ta

0.01

0.1

1

10

100

1000

10000

Com

plex

Mod

ulus

(M

Pa)

-100 -50 0 50 100 150 200 250

Temperature (°C)

Sample: Test 1Size: 7.0848 x 2.9600 x 1.3300 mmMethod: Temperature Ramp

DMAFile: C:\Users\RET\Kraton sample.001Operator: Yi LinRun Date: 14-Jul-2008 14:23Instrument: DMA Q800 V7.4 Build 126

Universal V4.3A TA Instruments

0.0

0.1

0.2

0.3

0.4

Tan

Del

ta

100

1000

10000

Com

plex

Mod

ulus

(M

Pa)

-50 0 50 100 150 200 250

Temperature (°C)

Sample: PETSize: 8.2522 x 4.7500 x 0.1800 mmMethod: Temperature Ramp

DMAFile: C:\Users\RET\PET.001Operator: Yi LinRun Date: 17-Jul-2008 13:31Instrument: DMA Q800 V7.4 Build 126

Universal V4.3A TA Instruments

top related