Results from first tests of TRD prototypes for CBM

DPG Frühjahrstagung Münster 2011Pascal Dillenseger

Institut für Kernphysik Frankfurt am Main

2

Contents

• Overview of the CBM experiment• CBM-TRD– General TRD requirements– The IKF CBM-TRD– Laboratory performance measurements– CERN Nov. 2010 CBM-TRD testbeam• Setup• Preliminary results

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

3

The CBM experiment

• The dedicated heavy ion experiment at FAIR– Study phase diagram at low energies but high

densities• Accelerators

• SIS 100:– 27 GeV/u for U92+ – 5*1011 Ions per bunch

• SIS 300:– 35 GeV/u for U92+

• Observables• Charmonium, direct photons…

4

The electron identification setup

Vertex reconstruction and momentum measurement:

-Micro-Vertex Detector-Silicon Tracking System

Particle IDentification (PID):

-Ring Imaging CHerenkov-Transition Radiation Detector

- 3 stations with 4 layers each-Time Of Flight -EM Calorimeter

CBM TRD-Developement at the IKF Pascal Dillenseger

5

TRD requirements

• The TRD will be used as…– an electron identification detector– a tracking detector

• Main difficulties are… – the expected high hit rates up to 140 kHz/cm² – the big area ( 1000m² ) that needs to be covered

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

6

Design specifications

• High rates -> fast readout• Big area -> easy and economic to build• Good PID -> Pion rejection factor (PRF) 100• Tracking capability• There are several different attemps, build an tested by

working groups from:– Münster, Dubna, Bucharest and Frankfurt

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

7

The attempt of the IKF

A MultiWire Proportional Chamber (MWPC)with:

- a small gas gap - a small wire pitch- no drift region

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

8

The prototypes

Four prototypes with different gas gaps and wire pitches havebeen build

6 mm gas gap - 2 mm wire pitch

6 mm gas gap - 3 mm wire pitch

10 mm gas gap - 5 mm wire pitch

10 mm gas gap - 2.5 mm wire pitch

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

9

Laboratory performance measurements

Energy resolution• Measured with an 55Fe

x-ray source• Fe-Kα-Peak 5,9 keV• Ar-Escape-Peak 2,9 keV• Gas mixture

Ar/CO2 (85%/15%)

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

10

55Fe spectraCBM-TRD 6 mm gas gap 3 mm wire pitchUa = 1450 VΔE = 0,289

CBM-TRD 10 mm gas gap 2.5 mm wire pitchUa = 2440 VΔE = 0,298

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

11

Testbeam setup

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

12

Testbeam specifications

• CERN PS accelerator• Prototypes with 10 mm gas gap were tested• An ALICE type radiator was used• Used gas mixtures were– Ar/CO2 (80%/20%)

– Xe/CO2 (80%/20%)

• High voltage set up– 1800 V for the chamber with 5 mm wire pitch– 2440 V for the chamber with 2.5 mm wire pitch

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

13

Front-end-electronics

• As readout electronics the SPADIC-chip and the SUSIBO-board were used – Self-triggered Pulse Amplification and Digitization

asIC• 8 channels • 90 ns shaping time• 8 Bit ADC• Sampling rate 25 MHz

– SUSIBO-board is a Virtex 5 board with which the data can be transferred to the pc via FTDI-chip

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

14

Single event from the testbeam readout with the spadic-chip

Preliminary results

Raw data Same event baseline corrected and background subtracted

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

15

Electron-Pion Spectra for 5 GeV/c beam Xe/CO2 (80%/20%)

10 mm gas gap5 mm wire pitch

10 mm gas gap 2.5 mm wire pitch

Simulations Patrick Reichelt - HK 39.46 – Testbeam data analysis Weilin Yu

Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

16

Summary

• Fast and easy to build TRD is needed• Solution…

flat symmetric MWPC without a drift region• Good performance in measurements with 55Fe

x-ray source• Good performance at CERN testbeam