roof specialty products & fall protection systems · (102 mm) trade sizes 3” (76 mm) 4”...
Post on 01-Mar-2021
23 Views
Preview:
TRANSCRIPT
WWW.THALERMETAL.COM
Solution to ALL YOUR ROOFING NEEDS
ROOF SPECIALTY PRODUCTS &FALL PROTECTION SYSTEMS
ABOUT THALER METALThe Thaler Metal Industries Limited story starts around 1969 when Ken Thaler, formerly the Chief Estimator/Supervisor with a large roofing company in the 1950’s and 1960’s, recognized the need for a higher quality of roofing specialty products such as flashings, vents, roof drains, and other roof protrusion products. The high incidence of roof leaks, maintenance and labour intensive roofing specialty products inspired Ken to design and promote a superior line of roofing accessories that continue to be unequalled today.
FLOURISHING AMID THE CHALLENGES OF THE ROOFING INDUSTRYFrom the 1970’s to the 2000’s, Thaler developed, engineered and honed a multitude of roofing accessory products including mechanical and electrical protrusion flashings, roof supports (all disciplines), air vents, relief vents, suspended maintenance fall production safety anchors, davit arms and roof drains. All Thaler products have a number of “Value Added” features that should be considered when trying to equate the “Or Equal Factor”.
FOR EXAMPLE, THE SINGLE MOST IMPORTANT DEVELOPMENT AT THE CENTRE OF THE COMPANY’S ACCOMPLISHMENTS – AN INDUSTRY FIRST – IS THE INVENTION, BY KEN THALER, OF UNIQUE PATENTED EPDM FLASHING SEALS FOR MECHANICAL AND ELECTRICAL ROOF PENETRATIONS. IN GENERAL, ALL ROOF PENETRATIONS ARE SUBJECT TO THE HARMFUL EFFECTS OF CONDENSATION THAT IS RESPONSIBLE FOR UP TO 80% OF ALL ROOF LEAKS.
Today however, the Thaler EPDM Base Seal eliminates condensation and condensation buildup from below, and the Thaler EPDM Triple pressure Grommet Seal eliminates flashing leaks from above. The implementation of these EPDM flashing seals in a wide array of Thaler roofing products represent a new generation of roofing products that meet the requirements of air leakage control better than any protrusion type flashings on the market today.
THALER’S COMMITMENTIn keeping with a tradition for being innovative, Thaler is constantly thinking of new and better ways to enhance roofing system performance recognized dependability. Thaler always has a better idea (keep an eye on our advances in speciality products for metal roofs). Construction professionals will continue to benefit from Thaler’s commitment to providing state-of-the-art, consistently better roofing products while assuring architects, engineers, roofing consultants, specifiers, contractors, and building owners 100% roof penetration protection - an affirmation backed by the THALER 20 YEAR WARRANTY.
THALER METAL Synonymous with the VERY BEST in ROOFING PERFORMANCE and DEPENDABILITY.
Mission Statement - Business Philosophy
PG DIVISIONS
TABLE OF CONTENTS
Exhaust Vent Flashings
Stack Jack Flashings
Mechanical & Electrical Flashings
Architectural Roof Supports
Mechanical & Electrical Roof Supports
1
3
2
4
5
7
9 Relief Vents
10 Gravity Air Vents
11 Fall Arrest Roof Anchors (FARA) - TWA - Econo Anchor
13 Split Flashings
14 Horizontal Lifeline Systems
15 Roof Drains
17 Planning & Engineering Services
19 Roof Replacement Accessories
MISSION STATEMENT
To conscientiously listen to the needs of our partnering patrons and be obligated and accountable to provide technical knowledge, superior quality products and service they need to benefit their business.
KEN THALER
THALER BUSINESS PHILOSOPHY
Research, design and produce a range of roofing products that will outperform and provide longer life than any similar products being offered to the building industry.
1 |
CONCRETE DECK STEEL DECK
4"(102 mm)
7"(1
78 m
m)
13" o
r 19"
(330
or 4
83 m
m)
PATENTED
PREMOULDED TO INNER
(ALUMINUM, COPPER AND
EMBED DECK FLANGEIN LAYER OF PLASTIC CEMENT
TRIPLE PRESSURE GROMMET SEAL
EPDM BASE SEAL BONDED TO METAL SLEEVE
STAINLESS STEEL)
STACK JACK FLASHINGTHALER NEW-STANDARD
URETHANE INSULATION
SIDE OF SLEEVE
TRADE SIZES2” (51 mm)3” (76 mm)4” (102 mm)5” (127 mm)6” (152 mm)
MODEL HEIGHT
SJ-37 7” (178 mm) highSJ-38 13” (330 mm) highSJ-39 19” (483 mm) high
NEW-STANDARD STACK JACK™ FLASHING (Insulated)
CONVENTIONAL ROOFINGILLUSTRATED
INVERTED ROOFING ILLUSTRATED
VENT PIPE
STACK JACK FLASHINGS | 2
STACK JACK FLASHINGSTM
SJ-26 / SJ-27Removable CapSTACK JACK FLASHINGTM
SJ-37 / SJ-38 / SJ-39STACK JACK FLASHINGTM
SJ-31 VandalproofSTACK JACK FLASHINGTM
SJ-44 / SJ-45Sloped RoofSTACK JACK FLASHINGTM
SJ-33Vandalproof Vent CapSTACK JACK FLASHINGTM
SJ-VPC VandalproofSTACK JACK FLASHINGTM
SJ-24 / SJ-25Removable CapSTACK JACK FLASHINGTM
SJ-34 / SJ-35 / SJ-36STACK JACK FLASHINGTM
SJ-26 / SJ-27Removable CapSTACK JACK FLASHINGTM
SJ-37 / SJ-38 / SJ-39STACK JACK FLASHINGTM
SJ-31 VandalproofSTACK JACK FLASHINGTM
SJ-44 / SJ-45Sloped RoofSTACK JACK FLASHINGTM
SJ-33Vandalproof Vent Cap
SJ-VPC VandalproofSTACK JACK FLASHINGTM
SJ-24 / SJ-25Removable CapSTACK JACK FLASHINGTM
SJ-34 / SJ-35 / SJ-36STACK JACK FLASHINGTM
EXHAUST VENT FLASHINGS
EVF-1 / EVF-2Exhaust Vent Flashing
EVF-1Exhaust Vent Flashing
EVF-1 / EVF-2Exhaust Vent Flashing
EVF-1Exhaust Vent Flashing
EVF-3 / EVF-4Exhaust Vent Flashing
3 | EXHAUST VENT FLASHINGS
MODEL HEIGHT
EVF-1 12” (305 mm) highEVF-2 12” (305 mm) high
EXHAUST VENT FLASHINGSPatented
EPDM BASE SEAL BONDEDTO METAL SLEEVE (SEETHALER EPDM FLASHINGSEALS LITERATURE)THALER EXHAUST VENT
FLASHING (ALUMINUM,COPPER OR STAINLESSSTEEL)
REMOVABLE HOOD (ALUMINUM,COPPER ORSTAINLESS STEEL)
4” (102 mm)
TRADE SIZES3” (76 mm)4” (102 mm)5” (127 mm)6” (152 mm)7” (178 mm)8” (203 mm)9” (229 mm)
10” (254 mm)
STEEL DECK CONCRETE DECK
CONVENTIONAL ROOFINGILLUSTRATED
EXHAUST VENT
EVF-2(PERFORATED COLLAR)
URETHANE INSULATIONPRE-MOLDED BETWEENINNER AND OUTERSLEEVE
EVF-1 (SLOTTED COLLAR)
CHERRY RIVETS HAVING8274 kPa (1200 psi)SHEARING STRENGTH
STAINLESS STEELSCREWS (TWO TOTAL)
12”
(305
mm
)
Add suffix -A for Aluminum or -Cfor Copper to Model No. e.g. EVF-1-A, etc.
MECHANICAL & ELECTRICAL FLASHINGS | 4
MECHANICAL & ELECTRICALFLASHINGS
MEF-1Rigid Conduit Flashing
MEF-2AFlexible Conduit Flashing
MEF-3AHot Pipe Flashing
MEF-AE1 Type BRigid Conduit Flashing
MEF-4A“B” Vent Flashing
MEF-AE1 Type ASingle Rigid Conduit Flashing
MEF-2A1Liquid Tight FlexibleConduit Flashing
MEF-9Modcon Gas Pipe Flashing
MEF-1Rigid Conduit Flashing
MEF-2AFlexible Conduit Flashing
MEF-3AHot Pipe Flashing
MEF-AE1 Type BRigid Conduit Flashing
MEF-4A“B” Vent Flashing
MEF-AE1 Type ASingle Rigid Conduit Flashing
MEF-2A1Liquid Tight FlexibleConduit Flashing
MEF-9Modcon Gas Pipe Flashing
MEF-2A/MEF-2A1/MEF-2A2 LIQUID TIGHT FLEXIBLE CONDUIT FLASHINGPatented
EPDM BASE SEAL, BONDED TO METAL BASE (SEE THALER EPDM FLASHINGSEALS LITERATURE)
THALER MEF-2A LIQUIDTIGHT FLEXIBLE CONDUITFLASHING
CONCRETE DECKSTEEL DECK
EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT
LIQUID TIGHT FLEXIBLE CONDUIT (BY OTHERS)
#14 x 2”, COUNTERSUNK STAINLESSSTEEL SCREWS (QUANTITY DIFFERSBETWEEN MODELS).
EPDM END CAP SEAL, FRICTION FIT TO METAL PIPE (SEE THALER EPDM FLASHINGSEALS LITERATURE)
WOOD BLOCKING TO MATCH DECK FLANGE WIDTH, LENGTH ANDINSULATION THICKNESS (BY OTHERS)
CONVENTIONAL ROOFINGILLUSTRATED
3D-VIEW SHOWING MEF-2A1 MODEL
RE
FER
TO
TE
CH
NIC
AL
BIN
DE
R
4”(102 mm)
ARCHITECTURAL ROOF SUPPORTS
ARS-115Rail Post
ARS-400Flag Pole or Rail Roof Support
ARS-122Satellite Dish Roof Support
ARS-450 A/C UnitScreen Roof Support
ARS-133Antenna Roof Support
ARS-510Metal Stair Roof Support
ARS-102Fire Route Walkway
ARS-200 & ARS-210Trellis and BraceRoof Support
ARS-530Stair Platform Roof Support
ARS-540Upright Angle Roof Support
ARS-550Miscellaneous PlateRoof Support
ARS-115Rail Post
ARS-400Flag Pole or Rail Roof Support
ARS-122Satellite Dish Roof Support
ARS-450 A/C UnitScreen Roof Support
ARS-133Antenna Roof Support
ARS-510Metal Stair Roof Support
ARS-102Fire Route Walkway
ARS-200 & ARS-210Trellis and BraceRoof Support
ARS-530Stair Platform Roof Support
ARS-540Upright Angle Roof Support
ARS-550Miscellaneous PlateRoof Support
ARS-520Metal Stair Roof SupportOffset Stringer
5 | ARCHITECTURAL ROOF SUPPORTS
ARCHITECTURAL ROOF SUPPORTS | 6
ARS-590Satellite Dish Roof Support
ARS-680Cross-Over Stair
ARS-685 Tilt-Up AccessLadder & Roof Support
ARS-590Satellite Dish Roof Support
ARS-680Cross-Over Stair
ARS-685 Tilt-Up AccessLadder & Roof Support
ARS-575 TriangularAntenna Roof Support
CONCRETE DECK
STACK JACK FLASHING URETHANEINSULATED, 12" (305 mm) HIGHSLEEVE (ALUMINUM, COPPEROR STAINLESS STEEL)
INVERTED ROOFING ILLUSTRATED
STAINLESS STEEL STUD
CONSULT STRUCTURAL ENGINEER FOR I BEAMSTRENGTH REQUIREMENTS
STEEL PLATE(SEE CHART)
18 GA. (1.2 mm) GALVANIZED CLOSURE PLATE SCREWFASTENED TO STEEL DECK
STEEL DECK
ALL STEEL COMPONENTS EPOXYPRIMED AS STANDARD.FOR GALVANIZED FINISHADD SUFFIX -G TO MODEL NUMBER, I.E. ARS-550-1-G
CONVENTIONAL ROOFINGILLUSTRATED
HSS WELDED TO BASE PLATE USING 5/16" (8 mmFILLET WELD (SEE CHART)
EPDM BASE SEAL BONDED TOMETAL SLEEVE (SEE THALER EPDMFLASHING SEALS LITERATURE)
4"(102 mm)
4-1/
2"(1
14 m
m)
SUPPORT PLATE.SEE CHART FOR SIZES
FOUR S.S. BOLTS AND NUTS (SEE CHART FOR DIA. SIZES)
EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT
CONTINUOSLY WELDEDGUSSET PLATE
EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT
STEEL PLATE(SEE CHART)
ARS-550, 550-1, 550-2 MISCELLANEOUS ROOF SUPPORTPATENTED
1/4" X 8" X 8"(6 mm x 203 mm x 203 mm)
(12 mm x 305 mm x 305 mm)1/2" x 12" x 12"
3/4" x 12" x 12"(19 mm x 305 mm x 305 mm)
PLATE
1/2" X 6" X 6"
(16 mm x 203 mm x 203 mm)
(13 mm x 152 mm x 152 mm)
(10 mm x 102 mm x 102 mm)
HSS SUPPORT PIPENUMBER
ARS-550
ARS-550-1
ARS-550-2
MODEL
2-3/8"14"
(356 mm)14"
14"(356 mm)
(356 mm)
(114 mm)4-1/2"
3-1/2"
(60 mm)
(89 mm)
Height Outside Ø
(25 mm)1"1/4"
(51 mm)
(51 mm)
(6 mm)
(6 mm)
(6 mm)
1/4"
1/4"
2"
2"
THREAD
Thickness Ø
1/4" X 12" X 12"
3/4" X 12 "X 12"(19 mm x 305 mm x 305 mm)
3/8" X 12" X 12"(10 mm x 305 mm x 305 mm)
(6 mm x 305 mm x 305 mm)
Bolt
3/8" X 4" X 4"
5/8" X 8" X 8"
SecurementWeld
Securement
(16 mm)
(10 mm)
(6 mm)1/4"
5/8"
3/8"
FASTENINGBOLT Ø
FOR SUPPORTS OTHER THAN STANDARD 14" (356 mm) HEIGHT, ADD SUFFIX "NS" TO MODEL NUMBER I.E. ARS-550-2/NS
Please be advised Thaler products may undergo improvements from time to time and are subject to change without notice.
SUPPORT BASE PLATE
MERS-925 Air HandlingUnit Roof Support
MERS-915A Air HandlingUnit Roof SupportSmall Multiple Units
MECHANICAL & ELECTRICALROOF SUPPORTS
MERS-700 TerraceLighting Roof Support
MERS-707 Gas Line / ConduitRoof Support
MERS-740 MiscellaneousLighting Roof Support
MERS-650 Re-RoofingLarge Pipe Support
MERS-605Double Pipe Support
MERS-610 Pipe Support(single, insulated)
MERS-615 Pipe Support(double, insulated)
MERS-600A Pipe Support
MERS-708 Tiered GasLine Roof Support
MERS-730 SecurityLighting Roof Support
MERS-850ARe-Roofing Duct Support
MERS-900A Air HandlingUnit Roof Support
MERS-800ADuct Support
7 | MECHANICAL & ELECTRICAL ROOF SUPPORTS
MERS-925 Air HandlingMERS-915A Air Handling
MERS-700 TerraceLighting Roof Support
MERS-707 Gas Line/ConduitRoof Support
MERS-740 MiscellaneousLighting Roof Support
MERS-650 Re-RoofingLarge Pipe Support
MERS-605Double Pipe Support
MERS-610 Pipe Support(single, insulated)
MERS-615 Pipe Support(double, insulated)
MERS-600A Pipe Support
MERS-708 Tiered GasLine Roof Support
MERS-730 SecurityLighting Roof Support
MERS-850ARe-Roofing Duct Support
MERS-900A Air Handling
MERS-800ADuct Support
MERS-910 Re-Roofing AirHandling Unit Roof Support
MERS-930A Re-Roofing AirHandling Unit Roof Support
MECHANICAL & ELECTRICAL ROOF SUPPORTS | 8
MERS-709 Combo PipeSupport & Cross Over Stair
MERS-630 Aluminum PipeSupport (large, insulated)
MERS-930A Re-Roofing Air
MERS-709 Combo PipeSupport & Cross Over Stair
MERS-630 Aluminum PipeSupport (large, insulated)
MERS-900A Air HandlingUnit Roof Support
T-300 ALUMINUM PIPE 2" (51 mm) DIA. URETHANE INSULATED WELDED TO 3/8" x 8" x 8" (9 mm x 204 mm x 204 mm)ALUMINUM PLATE
4"(102mm)
2" (5
1mm
)
2" (5
1mm
)
STAINLESS STEEL STRAP
NOTE:AVAILABLE SIZES 11" TO 22"(270 mm TO 559 mm) IN 1" INCREMENTSSIZES 11"TO 17" (279 TO 432 mm)PROVIDE UP TO 1" (25 mm ) ADJUSTMENTSIZES 18" UP TO 22" (457 mm TO 559 mm)PROVIDE UP TO 4" (102 mm) ADJUSTMENT
STAINLESS STEEL SET SCREW
STAINLESS STEEL BOLT
EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT (BUR)
EPDM BASE SEAL BONDED TO METAL SLEEVE
ACCOMMODATES PIPE SIZES FROM 2' TO 8" (51 mm TO 203 mm)
BUILT-UP ROOFING ILLUSTRATED (SEEINSTALLATION)
EPDM TRIPLE PRESSURE GROMMET SEAL
EXTRUDED ALUMINUM CARRIER ASSEMBLY (T-165, T-175)
SJ-34 STACK JACK (NON-INSULATED)SJ-37 STACK JACK (INSULATED) AVAILABLE ALUMINUM, COPPER OR STAINLESS STEEL
F3Specify the fastening method required by adding the appropriate suffix to a model number (e.g. MERS-615A-F2).
F7F2 F5
FASTENING METHODS
AVA
ILAB
LE 1
1" T
O 2
2' (2
79 m
m T
O 5
59 m
m)
SEE
NO
TE B
ELO
W
MERS-615A ALUMINUM PIPE SUPPORT (Double Insulated Pipe)PATENTED
RELIEF VENTS
RV-2A / RV-2CTwo Way Relief Vent
RV-2A / RV-2CTwo Way Relief Vent
RV-3A / RV-3COne Way Relief Vent
RV-2A / RV-2CTwo Way Relief Vent
RV-2A / RV-2CTwo Way Relief Vent
RV-1A / RV-1CTwo Way Relief Vent
9 | RELIEF VENTS
REMOVABLE HOOD FOR MOISTURE CHECKING
0.064" (1.6 mm) ALUMINUM, 24 oz. (0.831 mm)) COPPER REMOVABLE CONICAL HOODFITTED WITH PERFORATED COLLAR
RIVETS
STAINLESS STEEL SCREWS
0.064" (1.6 mm) ALUMINUM, OR 24 oz. (0.831 mm) COPPER SLEEVE URETHANE INSULATE
12" (
305
mm
)
3-3/
4" (8
6 m
m)
4" (102 mm)
3-1/2" (89 mm)
4-1/2" (114 mm)
12" (305 mm) DIA.
BITUMINOUS PAINTED INSULATION INSERT ACCESSORY. LOWER HALF PERFORATED WITH 1/4" (6 mm) DIA. HOLES.
RV-2A ALUMINUM, RV-2C COPPER RELIEF VENTPATENTED
GRAVITY AIR VENTS
GAV-2A / GAV-2C / GAV-2SSGravity Air Vent (large)
GAV-3A / GAV-3C / GAV-3SSGravity Air Vent(small-slope roof)
GAV-4A / GAV-4C / GAV-4SSGravity Air Vent(large-slope roof)
GAV-2A / GAV-2C / GAV-2SSGravity Air Vent (large)
GAV-3A / GAV-3C / GAV-3SSGravity Air Vent(small-slope roof)
GAV-1A / GAV-1C / GAV-1SSGravity Air Vent (small)
GRAVITY AIR VENTS | 10
144 Square inches (930 cm2) of free venting area is required to vent 300 square feet of roof area (1/300). A minimum of two vents are required to vent any individual roof area. Venting efficiency is increased in direct proportion to the number of vents used.
on a 300 square foot (28 m²) roof is preferable to using two vents, each with72 square inches (464 cm²) of free venting area. Increasing the number of vents, while maintain the required total amount of free venting area by decreasing the size of the individual vents allows air to drawn from the corners of the roof, thereby increasing overall venting efficiency, and avoiding condensation formation.
REMOVABLE CONICAL HOOD (FOR CLEANING) FITTED WITH THREE SUPPORT BRACKETS.0.064" (1.6 mm) ALUMINUM,24 oz. 0.032" (0.831) COPPER OR22 ga. 0.031" (0.79 mm) STAINLESS STEEL.
STAINLESS STEEL SCREW
STAINLESS STEEL SCREW
SLEEVE WITH INTEGRAL DECK FLANGE 0.064" (1.6 mm) ALUMINUM, 24 oz. 0.032" (0.831 mm) COPPER OR22 ga. 0.31" (0.79 mm) STAINLESS STEEL.
STAINLESS STEEL WOOD SCREWON 6" (162 mm) APPROX. DISTANCE
4.5" (114 mm)3" ( 76 mm)
12" (
305
mm
)
INSECT SCREEN
3" (75 mm)
4" (1
02 m
m)
"A"
EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT
T-8 BITUMEN PROTECTION (OPTIONAL)
3 PLY FELT FLASHING OVER FLANGEAND 4" (102 mm), 6" (152 mm), AND 8" (203 mm) ONTO ROOF
WHEN ORDERING, STATE INSIDE DIAMETER (ID) OF VENT PIPE
AVAILABLE DIAMETERS "A"
3" (75 mm) 4" (102 mm) 5" (127 mm) 6" (152 mm) 7" (178 mm) 8" (203 mm) 9" (229 mm)10" (254 mm)
GAV-1A, GAV-1C, GAV-1SS GRAVITY AIR VENTS (Small Size Vents)
CONCRETE DECK STEEL DECK
CALCULATING THE NUMBER OF GRAVITY AIR VENTS
For example: Four vents each with 36 square inches (232 cm²) of free venting area
FALL ARREST ROOF ANCHORS
11 | FALL ARREST ROOF ANCHORS
FARA -2/ -12 / -12SS /-12U / -12USSAdhesive Bolt
FARA -3/ -13 / -13SS /-13U / -13USSBolt Around Beam
FARA -33/ -43 / -43SS/ -43U / -43USSFARA -35/ -45 / -45SS/ -45U / -45USS
FARA -4/ -14 / -14SS /-14U / -14USSWeldable
FARA -5/ -15 / -15SS /-15U / -15USSCast In Place
FARA -3/ -13 / -13SS /-13U / -13USSBolt Around Beam
FARA -1 / -11 / -11SS /-11U / -11USSBolt Through
FARA -32/ -42 / -42SS /-42U / -42USS“SWIVEL EYE” Adhesive Bolt
FARA -33/ -43 / -43SS /-43U / -43USS “SWIVEL EYE”Bolt Around Beam
FARA -34/ -44 / -44SS /-44U / -44USS“SWIVEL EYE” Weldable
FARA -31/ -41 / -41SS /-41U / -41USS“SWIVEL EYE” Bolt-Through
FARA -37/ -47 / -47SS /-47U / -47USS “SWIVEL EYE”Pre Cast Core Bolt
FARA -82 / -92 / -92U /WALL ANCHORCast In Place
FARA -96TERRACE ANCHOR
FARA -84/ -94 / -94SS /-94U / -94USSCladding Bolt
FARA -96A / -106A / -106ASS /-106AU / -106AUSS High FallArrest Terrace Roof Anchor
FARA -36/ -46 / -46SS /-46U / -46USS “SWIVEL EYE”Bolt Around OWSJ
FARA -150DAVIT Arm Base
FARA -155Movable DAVIT Arm
FARA -170 Swivel OutriggerBeam and Arm
FARA -180Fall Arrest “Rope Drop” Anchor
FARA -96A / -106A / -106ASS /-106AU / -106AUSS High Fall
FARA -96B / -106B / -106BSS /-106BU / -106BUSS High FallArrest Terrace Roof Anchor
FARA -2/ -12 / -12SS /-12U / -12USSAdhesive Bolt
FARA -4/ -14 / -14SS /-14U / -14USSWeldable
FARA -5/ -15 / -15SS /-15U / -15USSCast In Place
FARA -1 / -11 / -11SS /-11U / -11USSBolt Through
FARA -32/ -42 / -42SS /-42U / -42USS“SWIVEL EYE” Adhesive Bolt
FARA -33/ -43 / -43SS /-43U / -43USS “SWIVEL EYE”Bolt Around Beam
FARA -34/ -44 / -44SS /-44U / -44USS“SWIVEL EYE” Weldable
FARA -31/ -41 / -41SS /-41U / -41USS“SWIVEL EYE” Bolt-Through“SWIVEL EYE” Bolt-Through
FARA -37/ -47 / -47SS /-47U / -47USS “SWIVEL EYE”Pre Cast Core Bolt
FARA -82 / -92 / -92U /WALL ANCHORCast In Place
FARA -96TERRACE ANCHOR
FARA -84/ -94 / -94SS /-94U / -94USSCladding Bolt
FARA -96A / -106A / -106ASS /-106AU / -106AUSS High FallArrest Terrace Roof Anchor
FARA -36/ -46 / -46SS /-46U / -46USS “SWIVEL EYE”-46USS “SWIVEL EYE”Bolt Around OWSJ
FARA -150DAVIT Arm Base
FARA -155Movable DAVIT Arm
FARA -170 Swivel OutriggerBeam and Arm
FARA -180Fall Arrest “Rope Drop” Anchor
FARA -96A / -106A / -106ASS /-106AU / -106AUSS High Fall
FARA -96B / -106B / -106BSS /-106BU / -106BUSS High FallArrest Terrace Roof Anchor
TWA (ECONO) ANCHORSASK ABOUT THIS PRODUCT
FROM OUR TEAM OF ENGINEERS
(ECONO) ANCHORS THATMEET ALL CANADIAN AND
U.S. STANDARDS ATCOMPETITIVE PRICING
Arrest Terrace Roof Anchor-Top View
FALL ARREST ROOF ANCHORS | 12
FARA -100 / -101 / -110 /Fall Arrest Rope Stop
FARA -7/ -17 / -17SS /-17U / -17USSPre Cast Core Bolt
FARA -35/ -45 / -45SS /-45U / -45USS “SWIVEL EYE”Cast in Place
FARA -85/ -95 / -95U /Wall Anchor
FARA -100 / -101 / -110 /Fall Arrest Rope Stop
FARA -7/ -17 / -17SS /-17U / -17USSPre Cast Core Bolt
FARA -35/ -45 / -45SS /-45U / -45USS “SWIVEL EYE”Cast in Place
FARA -85/ -95 / -95U /Wall Anchor
FARA -1500Recessed David Arm Base
1/4' x 4-1/2" DIA. (6 mm x 114 mm ) HSS WELDED TO 5/8" x 8" x8"(16 mm x 203 x 203 mm)BASE PLATE USING 5/16"(8 mm ) FILLET WELD, ALL HOT DIP GALVANIZED AND URETHANE INSULATED TO PREVENT CORROSION.
FORGED EYE AND BASE WELDED TO HSS PIPE AND HOT DIP GALVANIZED
FOUR 5/8" (16 mm) S.S. BOLTS, LOCK WASHERAND NUTS
EPDM BASE SEALBONDED TO METAL SLEEVE(SEE THALER EPDM FLASHING SEALS LITERATURE)
5/8" x 8" x 8" (16 mm x203 mm x 203 mm) PLATE
DEFORM THREADSAS PER CSA OR OSHA GUIDELINE
THALER SJ-37(9) NEW STANDARD STACK JACK FLASHING (ALUMINUM, COPPER OR STAINLESS STEEL)
INVERTED ROOFILLUSTRATED (BUR)
CONVENTIONAL ROOF ILLUSTRATED (BUR)
GUSSET PLATESBY OTHERS (WHEN REQUIRED)
4-1/2" (114 mm)
3-1/4" (82 mm)
14" (
356
mm
)12
-5/8
" (32
1 m
m )
18 GA. GALVANIZED CLOSURE PLATE SCREWFASTENED TO STEEL DECK
EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT (BUR)
EPDM TRIPLE PRESSURE GROMMET SEAL
FARA-3/-13/-13U FALL ARREST ROOF ANCHORS (Bolt Around Beam)PATENTED
FORGED EYE(FARA-3/-13)
U BOLT EYE(FARA-13U)
FARA-13
FARA-3
Anchor Type
FARA-13U
ALL TESTING REPORTS AVAILABLE UPON REQUEST
Forged Eye, Stainless Steel
U Bolt, Stainless Steel
Forged Eye, Galvanized
Eye Construction
Load Direction
Deflection After Load of 5400 lbs (24.03 kN) was Released
Perpendicular to the eye (x)
0.016"(0.406 mm)
0.046"(1.168 mm)
xy
Note: Anchors are designed to resist without fracture and/or pull-out a force of 5400 lbs (24.03 kN), applied in the most adverse direction (x).
0.203"(5.156 mm)
Parallelto the eye (y)
Parallelto the eye (y)
Perpendicular to the eye (x)
Perpendicular to the eye (x)
Parallelto the eye (y)
0.008"(0.203 mm)
0.019"(0.482 mm)
0.013"(0.330 mm)
Typical tie-offdirection
All stainless steel anchor alsoavailable (FARA-13SS/-13USS)e.g. eye, HSS, base plates,fastening and flashing.
* FOR NON-STANDARD ALTERNATIVES PLEASE CONTACT OFFICE
SPLIT FLASHINGS
13 | SPLIT FLASHINGS
SPJ-2Round Split Flashing
SPJ-3Square Split Flashing
SPJ-4Square Split FlashingVented Cap
SPJ-2Round Split Flashing
SPJ-3
SPJ-1Round Split Flashing
0.018" (26 ga.) TYPE 304STAINLESS STEEL CAP
0.018" (26 ga.) TYPE 304STAINLESS STEEL SLEEVE
S.S INSTALLATION CLAMPING CLIPS SPOT WELDED TO SLEEVE ON TWO SIDES (3 OR 4 CLIPS DEPENDING ON HEIGHT)
5" (127 mm)
EPDM TRIPLE PRESSURE GROMMET SEAL
PATENTED
1/8" (3 mm) STAINLESS STEEL SCREW
12" (
305
mm
) OR
18"
(457
mm
)
1" (2
5 m
m)
3 PLY FELT FLASHING OVER FLANGE 4" (102 mm) 6" (152 mm) AND 8" (203 mm) ONTO ROOF
EMBED DECK FLANGE IN LAYER OF PLASTIC CEMENT
TOP VIEW OF CAP
KCED ETERCNOCKCED LEETS
SPJ-3 SQUARE SPLIT FLASHING PATENTED
TERMINAL END HORIZONTAL LIFELINE ANCHOR (K-FARA-93-709)PATENT PENDING
PLAN VIEW
FRONT VIEW
CARABINER
SHACKLE
THALER ENERGY ABSORBER (TEA)
STAINLESS STEEL SWAGED END
3/8" (10 mm) S.S.END BRACKET WELDED TOTO 5/8" x 8" x 8" (16 mm x 203 mm x 203 mm) S.S. WALL PLATE
CONTINUOUS CAULKINGAROUND WALL PLATES (BY OTHERS)
CONTINUOUS 5/16 (8 mm)FILLET WELD
FOUR 5/8" (16 mm) ADHESIVE FASTENERS(RETROFIT APPLICATION)
MINIMUM 5" (127 mm)
MINIMUM 6" (152 mm)
SECTION VIEW
SHACKLE
THALER ENERGY ABSORBER (TEA)
2-3/4" (70 mm)
30'-0" (9.15 m) MAX. SPACING BETWEEN ANCHORS FOR SYSTEM WITH ONE ENERGY ABSORBER
30'-0" TO 60'-0" (9.15 TO 18.3 m)FOR SYSTEM WITH TWO ENERGY ABSORBERS
304 3/8" (10 mm) STAINLESS STEEL CABLE,7 x 19 STRUCTURE
Top View of End Wall AnchorWith Mobile Shuttle Runner
NOTE: ADHESIVE FASTENING ANCHORSECUREMENT IS ILLUSTRATED (RETROFIT APPLICATION). SEE PAGE K-3AFOR OTHER FASTENING METHODS
HORIZONTAL LIFELINE SYSTEMS | 14
HORIZONTAL LIFELINE SYSTEMS
K-700 (4) Shackle Connectionwith Tensioner
K-700 (7)Shuttle on Cable
K-700 (9)Single Straight Line
K-700 (10)Corner Anchor
K-700 (4) Shackle Connectionwith Tensioner
K-700 (7)Shuttle on Cable
K-700 (9)Single Straight Line
K-700 (3)Terminal Corner Anchor withTensioner and Energy Absorber
MaintenancePersonnelWorking AroundLow Parapet andNarrow Roof Area,a Typical FallHazard Area
Montage Illustration Shows K-701 EASY SLIDER Horizontal Lifeline Fall ProtectionSystem For Walls
Corner WallAnchorK-FARA-93-711WithEASY SLIDERShuttle (90° AngleIllustrated)
Any-Angle Corner Anchor K-FARA-93-712 And EAASY SLIDERShuttle
EndAnchor
IntermediateAnchor
Corner Anchor(90° Illustrated)
EASY SLIDERLifeline
End Tensioner
Intermediate WallAnchorK-FARA-93-710With Thaler EASYSLIDER Shuttle
End Anchor
Thaler Energy Absorber (TEA)
Terminal End AnchorK-FARA-93-709 (adhesive bolt fastening for retrofit applications)
Any-AngleCorner Anchor
Corner Anchor(Any Angle)
Roof AccessHatch
6’-6” (1.98 m)Recommended TypicalSpacing From Roof Edge
ShackleCarabiner
Swaged End
Terminal End AnchorK-FARA-93-709 With Thaler EnergyAbsorber (TEA). Adhesive Bolt Fastening For Retrofit Applications
TM EASY SLIDER is a registered trade mark of Thaler Metal industries Ltd. Patent and design pending
K-700 EASY SLIDER(Roof Application)
K-701 EASYSLIDER (WallApplication)
Inset Shows Top View of Corner Scenario
Top View ofInternal CornerAnchor
ROOF DRAINS
15 | ROOF DRAINS
RD-14 VandalproofRoof Drain
RD-14 RR VandalproofRoof Drain
RD-16 VandalproofRoof Drain
RD-16 RR VandalproofRoof Drain
RD4-RR VandalproofRoof Drain
RD-4 Vandalproof Roof Drain RD-4-8, RD4-10 Vandalproof BigRoof Drain with New 16” Dome
RD-7 RR Vandalproof Roof Drain
RD-1C Vandalproof CopperRoof Drain
RD-160 RR VandalproofRoof Drain
RD-19 SS Stainless SteelRoof Drain
RD-24 VandalproofRoof Drain
RD-160 VandalproofRoof Drain
RD-240 VandalproofRoof Drain
RD-24-8, RD-24-10Vandalproof Roof Drain
RD-28 Economy Roof Drain RD-28 RR EconomyRetrofit Roof Drain
RD-24 RR VandalproofRetrofit Roof Drain
RDX-30 RR EconomyRetrofit Roof Drain
RDX-30 Economy Roof Drain RD-38 Economy Roof Drain RD-38 RR Economy RetrofitRoof Drain
RDX-300 Economy Roof Drain RDX-300 RR EconomyRetrofit Roof Drain
RD-14 VandalproofRoof Drain
RD-14 RR VandalproofRoof Drain
RD-16 VandalproofRoof Drain
RD-16 RR VandalproofRoof Drain
RD4-RR VandalproofRoof Drain
RD-4 Vandalproof Roof Drain RD-4-8, RD4-10 Vandalproof BigRoof Drain with New 16” Dome
RD-7 RR Vandalproof Roof Drain
RD-1C Vandalproof CopperRoof Drain
RD-160 RR VandalproofRoof Drain
RD-19 SS Stainless SteelRoof Drain
RD-24 VandalproofRoof Drain
RD-160 VandalproofRoof Drain
RD-240 VandalproofRoof Drain
RD-24-8, RD-24-10Vandalproof Roof Drain
RD-28 Economy Roof Drain RD-28 RR EconomyRetrofit Roof Drain
RD-24 RR VandalproofRetrofit Roof Drain
RDX-30 RR EconomyRetrofit Roof Drain
RDX-30 Economy Roof Drain RD-38 Economy Roof Drain RD-38 RR Economy RetrofitRoof Drain
RDX-300 Economy Roof Drain RDX-300 RR EconomyRetrofit Roof Drain
RDX-30 RR Roof Drain
12" (
305
mm
) FO
R A
LUM
INU
M,
9" (2
29 m
m) F
OR
CO
PP
ER
AN
D
STA
INLE
SS
STE
EL,
STA
ND
AR
D
STEEL DECKCONCRETE DECK
EPDM PRESURE PLUG
CAST ALUMINUM STRAINER
3/8" (9 mm) STAINLESS STEEL RETAINING BOLT
STAINLESS STEEL BOLTAND NUT
0.064" (1.6 mm) ALUMINUM FUNNEL TYPE STRAIGHT OUTLET
STAINLESS STEEL WASHER AND NUT
CONVENTIONAL ROOF DECK ILLUSTRATED (EPDM)
T-12 STAINLESS STEEL BALLAST GUARD
T-7 ALUMINUMFLOW CONTROL ACCESSORY
EPDM SUPER-SEAL
EXISTING RAINWATER LEADER
URETHANE INSULATION (BY OTHERS) IS RECOMMENDED ONLY FOR DEPTH OF DECK TO ELIMINATE COLD SPOT AND CONDENSATION. PREVENTS ICE BUILD-UP IN WINTER AND MOISTURE DRIPPING TO SPACE BELOW IN SPRING
Note: Specify accessories required by adding appropriate suffix to model number e.g. RDX30-A-T-6 for ferrule, T-7 for flow control, T-10 stainless steel underdeck clamp and T-12 for stainless steel ballast guard.
T-10 STAINLESS STEEL UNDERDECKCLAMP (OPTIONAL)
15" (381 mm)
ALUMINUM STRAINER RETAINER/MEMBRANE COMPRESSION UNIT
CONVENTIONAL ROOF DECK ILLUSTRATED (EPDM)
RDX30-A-RR RETROFIT ROOF DRAIN (Aluminum, Funnel Type Outlet)RDX30-C-RR RETROFIT ROOF DRAIN (Copper, Funnel Type Outlet)
RDX30-SS-RR RETROFIT ROOF DRAIN (Stainless Steel, Funnel Type Outlet) Note: RDX30-C-RR (Copper) and RDX30-SS-RR (Stainless Steel) similar. See reverse side
of page for material changes.
15
ROOF DRAINS | 16
RD-7-8 Vandalproof Roof Drainwith New 16” Dome
RD-19 SS-RR Stainless SteelRetrofit Roof Drain
RD-29 RR EconomyRoof Drain
DD-1A Terrace Deck Drain
RD-7-8 Vandalproof Roof Drainwith New 16” Dome
RD-19 SS-RR Stainless SteelRetrofit Roof Drain
RD-29 RR EconomyRoof Drain
RD-39 Economy Roof Drain
DD-1 TERRACEDECK DRAIN
FLOOR DRAIN
RD-19-SS-BDB(Bolted Drain Body)
RD-19-SS
PLANNING & ENGINEERINGSERVICES
17 | PLANNING & ENGINEERING SERVICES
Engineered stamped layout or shop drawings for any fall protection scenario, including section details, can be produced for any building and any structural condition without obligation providing Thaler products are specified. Following the requirements of OSHA, labour regulations, safety standards or other regulatory bodies, roof anchors are located to provide the safest and most economical layout possible. Detailed installation instructions are supplied with every Thaler product for installation by others, or by Thaler if desired.
SAMPLESThaler will supply samples at no charge to specifiers on request, provided samples are returned upon completion of the evaluation.
SPECIFICATIONSSpecifications (Section Format) for fall protection roof anchors detailing the product, installation methodology, and structural loads are also provided.
ESTIMATING / PRICINGAn estimate can be provided for any roof anchor project based upon a published price list of all products supplied that is available upon request.
CUSTOM PRODUCTSThe need for custom designed products arises in many instances. Thaler can design, test and produce custom products to provide a workable solution. Simply provide the structural drawings, a roof plan, and building elevations, and Thaler will produce a layout, review it with the architect, engineer or specifier, refine it where necessary, and construct a prototype for acceptance and testing.
PLANNING & ENGINEERING SERVICES | 18
ROOF ACCESSORIES
T-5 Sediment Collar
T-6 Ferrule
T-7 Flow Control
T-9 Super Seal
T-10 Underdeck Clamp
T-12 Stainless SteelBallast Guard
Emseal Tape
T-13 Cast Aluminum Strainer(for RDX-30)
T-14 Cast Aluminum Strainer(RD-28 & RD-29)
T-15 Cast Aluminum Strainer (RD-4)
T-16 Cast Aluminum Strainer(for RD-7, RD-24)
New 16” Thaler Domes
T-17 Cast Aluminum Strainer(for RD-4-8, RD-4-10,
RD-7-8, RD-24-8, RD-24-10)
T-18 Cast Aluminum Strainer(for RD-14, RD-16)
T-19 Cast Aluminum Strainer(RD-38, RD-39)
T-20 PVC Strainer (RD-28, RD-29)
19 | ROOF ACCESSORIES
Roof Accessories
Replacement Roof Accessories
T-5
T-7
T-6
T-9
T-10
T-12
T-20
T-14 T-13
T-15 T-17
T-19
T-18
Emseal Tape
T-16
For a complete listing of all Thaler Roofing Products please refer to our Comprehensive Technical Binder.
LET US TELL YOU ABOUT THE THALER METAL DIFFERENCE!
WWW.THALERMETAL.COM
WWW.THALERMETAL.COM
HEAD OFFICEThaler Metal Industries Ltd.3857 Nashua DriveMississauga, ON L4V 1R3, CANADATEL. 905-677-1520 / 1-800-387-7217FAX 905-677-1503
USA Thaler Metal USA Inc.USA-CDN TOLL-FREE 1-800-576-1200USA Thaler Metal USA Inc.USA-CDN TOLL-FREE 1-800-576-1200
top related