R O T A R Y M E T E R S E R I E S R R M
Type approval
MID
EN12480
OIML R137
Weight & Measurement, India
Metrological Approvals
Performance Details
Dimension
Volume 3(dm ) (Kg)
L H A B C Weight
Corporate OfceRPG House 463, Dr. Annie Besant RoadWorli, Mumbai - 400030Tel.: 91-22-24937485 / 6Fax: 91-22-24938879Email: raychem@raychemrpg.com
Marketing Ofce
th 11 Floor, Vishwadeep Bldg., District Centre, Janak Puri, Delhi - 110058Dir: 91-11-45753737Fax: 91-11-2554 6239Email: prashant_pathak@raychemrpg.com
Raychem RPG Pvt. Ltd.
Manufacturing FacilityRaychem RPG Pvt. Ltd.HTS-TRD-WAGHJAIWaghjainagar Industrialist Association, Chakan, Gat No. 357/97, House no. 94, Kharabwadi - 410501, India
G-ValueVolume* 3V (dm )
Q max3(m /hr)
Q min3(m /hr)
Qt (Air) 3(m /hr)
Diameter D (mm)
P (bar) max ∆P* (Pa)
Basic Transfers** 3(rev-m )
G6
G10
G16
G25
G16
G25
G40
G65
G100
G160
G250
G400
G650
10
16
25
40
25
40
65
100
160
250
400
650
1000
0.5
0.5
0.5
0.5
0.65
0.65
0.65
1.00
1.00
1
1.6
2.5
6.25
0.5
0.8
1.25
2
1.25
2
3.2
5
8
12.5
20
32
50
1.5” BSPT
1.5” BSPT
1.5” BSPT
1.5” BSPT
50
50
50
50
80
80
100
100
150
21
21
21
21
21
21
21
21
21
21
21
12
12
8
20
48
120
28
72
190
400
190
635
230
607
662
4004.3250
4004.3250
4004.3250
4004.3250
2574.2680
2574.2680
2574.2680
1638.1630
861.8609
689.4840
315.3520
315.3520
194.0625
0.24973
0.38846
0.61044
1.16028
1.45036
3.17106
5.15298
0.24973
0.38846
0.61044
1.16028
1.45036
3.17106
5.15298
150
171
150/171
171
171/241
241/260
241/260
156/173
240/257
240/257
303/320
371/371
386/403
501/518
33
68
240
92
118
160
501
123/140
172/189
172/189
211/228
236/253
226/243
283/300
163
163
163
202
202
288
288
5
7
7.5
14
15
38
48
ENGINEERING GROWTHPIONEERING EXCELLENCE
Basic/Univ. Basic/Univ.
Email: krishan_shukla@raychemrpg.com
RRM RPD Meter Details
RRM RPD Meter Working Principle
The RRM series type Rotary Gas Flow Meters work on the principle of Positive Displacement. The actual measurement is performed by two oval (8) shaped rotors rotating within a measurement chamber. During a full revolution of the rotor a xed volume is displaced from inlet to outlet of the meter. The RRM series rotary gas meter measurement chamber makes the two ovals (8)-shaped rotors to turn, the volume of gas closed between the measuring chamber walls and rotors is transported four
0times in one full cycle. The timing gears set the rotors at the angle of 90 one to the other. The gear train, and the hermetic magnetic coupling, transfers the rotor rotation to the index unit, which is separated from the pressure tight housing body. The actual volume of gas is indicated on the mechanical counter.
Mechanical Index Counter
Cartridge Cover
Cartridge
Body
Gas entering into the body starts the Rotor
to rotate. In this position, gas is
captured.(1)
Rotors are rotating and now are at 90° angle and have captured
specic amount of gas.(2)
As s rotate further the gas ows at the outlet of the meter. Gas owing
out is equal to the volume captured at inlet.
(3)
With further rotation of impellers the gas ows
at the outlet of the meter. Gas owing out is equal to the volume captured at the inlet.
(4)
Raychem RPG rotary meters can be equipped (optional) with two Thermo-wells and two pressure tapping points. Therefore the rotary meters can be supplied with an Electronic Volume Conversion Device (EVCD). Raychem RPG offers a large variety in conversion devices so all required data can be provided and the best solution for every project can be assembled. Refer to the special brochure for more information about the Electronic Volume Conversion Devices Raychem RPG is able to supply or contact a local supplier.
RRM RPD Meter Application
Metrological Approvals
Main Features
RRM RPD Meters can be used for various non - aggressive gas application. As the meter is based on Positive Displacement Principle, hence it can be installed without any straight runs and can work at high accuracy in low ow and turbulent ow condition. Some of the gas application and industry applications are mentioned below:
Type of Gases : Natural gas, Propane, Butane, Air, Hydrogen, Non-aggressive gases, etc.
Application: City Gas Distribution, Industrial application, Check Metering, Custody Transfer
For other applications, please contact our sales ofce.
Type approval MID (T10738 RO)
Declaration EN12480:2002/A1:2006 Compliance
OIML Certicate of Conformity (OIML-R137-1(2012)
Weight & Measurement-India
Pressure Equipment Directive (PED) 97/23/EC compliant and IP-67 approved
ATEX : Sensor compliant with Ex ia IIC T4….T6 Gb (-40ºC ≤ Ta +70ºC
Encoder compliant with Ex ib IIB T3... T6 Gb (-25ºC ≤ Ta +55ºC)
3 3Flow range :0.5 – 1000 m /h (lower ow up to 0.25 m /hr available on request)
Diameters & End Connection :DN40 Threaded (BSP) / DN50 – DN150 Flanged
Pressure rates : ANSI 150 – 300, (other on Request)0 0MID temperature range : (-25) C to (+70) C (lower temperatures on request)
ATEX : (-25)°C to (+70)°C
Large Range : from 1:20 to 1:200 depends on G rating
Materials
Body : Aluminium Shafts :Stainless Steel
Impellers :Aluminium Gears : Delrin POM
Cartridge : Aluminium Index Frame : Aluminium
Timing Gears : Steel Bearing : Stainless Steel
Metrological Characteristics
RRM series of rotary meter is calibrated with air at atmospheric pressure, which is traceable to NMI calibrated references. It has been proven – as part of the type approval testing - that the difference between the accuracy at atmospheric air and at high pressure natural gas is negligible.
Accuracy Qt to Qmax : ±1% or better Accuracy Qmin to Qt : ± 2 % o r b e t t e r Repeatability : Better than 0.1%