RUNWAY INCURSION PREVENTION

& CREW ALERTING SYSTEM

(RIPCAS)

Ing. Roberto Gatti

RIPCAS – Main Concepts

•Very precise detection of vehicles/airplanes moving through the detection area•Very powerful signaling system based on high intensity red flashers•Reliable and proven control logic able to properly read the data coming from the sensors, process the data and generate, in case of unauthorized crossing, the immediate local alarm, alerting the crew and the TWR (via ALCMS system).

RIPCAS - Detection

& EU Regulations

24GHz PRC sensor

AC 150/5340-30

RIPCAS Microwave Sensors

The sensors are based on a transmitted and received microwave beam. Any change in the intensity of the beam on receiver side is processed in order to detect any crossing of the beam by vehicles and/or airplanes.

•250 channels available (24.000GHz .. 24.250 GHz) compliant to :

•ETSI EN 300 440-1 •ETSI EN 300 440-2•R&TTE Directive (1999/5/EC)•MIL-STD-461 (Emissions and Susceptibility)

RIPCAS – Microwave Sensors

Tx Rx

Tx Rx

Region of detection

The region of detection is designed to avoid any wildlife interference. A special antenna makes the beam very sharp and accurate.

Center of the microwave beam to ground 1m

Wild life safe height 0.7m

Wild life

interference free area

RIPCAS – Microwave Sensors

RIPCAS Visual cue (inset)

RIPCAS Visual cue (elevated)

> 3000cd in the Red

-20 -1

7 -14 -1

1 -8

-5

-2

1

4

7 10

13

16

19

20

17

14

11

8

5

2

-1

-4

0

1000

2000

3000

4000

5000

cd

horizontalvertikal

4000-5000

3000-4000

2000-3000

1000-2000

0-1000

FixtureLampFrequencyColor

EL217 SFL

80Ws

1Hz

red

RIPCAS – Flashing Lights

10

Flashing Light Unit > 3.000 cd Mod. ERNI EL 217 SFL - Xenon discharge lamp

Microwave detectors 24 GHz Mod . PRC CLP-MH microprocessor controlled and interfaced to ALCMS Prob. Detections 99,99% - False detections < 5*10 -3

(*)System Reaction time <1s

(*) Tested by third party Poiltecnico di Milano

MXP RIPCAS Configuration