oSiechem Annealed Tinned Copper Conductor, EBXL - XLPE 90 C Insulated & CSPE Sheathed 600 V rated Cable as Per UL Type TC
Part Number Cable Diameter(Nom.)
Insulation Thickness (Nom.)
Cable Weight (approx.)
No. of Strand/ Stand dia
Application Product Construction Technical Data
Wires & Cables
Cond. Size(AWG)
mm mm kg/km
Outer Sheath Thickness
mm
No.of Cond.
2/C flat
2/C flat
2/C flat
2/C
3/C
4/C
5/C
7/C
9/C
12/C
19/C
25/C
30/C
37/C
2/C
3/C
4/C
5/C
7/C
9/C
12/C
19/C
25/C
30/C
37/C
2/C
3/C
4/C
5/C
7/C
9/C
12/C
19/C
14
12
10
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10
10
7/0.615
7/0.775
7/0.978
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.775
7/0.775
7/0.775
7/0.775
7/0.775
7/0.775
7/0.775
7/0.775
7/0.775
7/0.775
7/0.775
7/0.978
7/0.978
7/0.978
7/0.978
7/0.978
7/0.978
7/0.978
7/0.978
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
5.66 x 9.04
6.15 x 10.01
6.73 x 11.18
9.12
9.63
10.5
11.5
12.5
15.3
17.2
19.9
24.2
25.7
27.7
10.1
10.7
11.7
12.8
14.7
17.1
19.2
23.4
27.1
28.9
31.2
11.3
11.9
13.1
15.1
16.5
19.2
22.6
26.4
116
141
196
121
138
173
201
283
390
479
752
938
1176
1310
158
183
256
305
411
536
679
1049
1302
1511
1820
208
253
374
460
557
778
979
1453
oSiechem Multicore Annealed Tinned Copper Conductor, XLPE 90 C Insulated & CSPE Sheathed 600 V rated Cable
ü�Rated voltage : 600 Voü�Temperature rating : 90 C
ü�Specification : Class IE Qualified in accordance with
IEEE 323-1974 and IEEE 383-1974
ICEA S-73-532(formerly
ICEA S-66-524 & S-19-81)
ü Flame Test : IEEE 383 (70,000 BTU/hr) as modified by NRC
IEEE 383 (70,000 BTU/hr)
IEEE 1202 (70,000 BTU/hr)
ICEA T-29-520 (210,000 BTU/hr )
UL VW -1
ü�Control cable is a 600 V multi-conductor,
thermoset, Class IE rated Construction
specifically designed for application in nuclear
generating stations and where flame
retardancy is critical.
ü�For use in class IE power distribution
and control circuits for power lighting,
control and signal circuits.
ü Can be installed in trays, conduit,
ducts or in direct burial applications.
ü�Conductor
ü�Insulation
ü Outer sheath
:
:
:
Annealed Tinned copper
Conductor as per ASTM B33
Cross-Linked polyethylene o(EBXL-XLPE 90 C)
Heavy-duty chlorosulphonated
polyethlene (CSPE)
ü Traceable
ü Flame retardant
ü Radiation stability
ü Long term moisture
ü Long term thermal endurance
ü Stripping for ease of termination
ü Radiation resistant up to 200 megarads
Features
95979XX
95978XX
95977XX
96079XX
96079XX
96079XX
96079XX
96079XX
96079XX
96079XX
96079XX
96079XX
96079XX
96079XX
96078XX
96078XX
96078XX
96078XX
96078XX
96078XX
96078XX
96078XX
96078XX
96078XX
96078XX
96077XX
96077XX
96077XX
96077XX
96077XX
96077XX
96077XX
96077XX
Catalogue No
959
www.siechem.com
17All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
oSiechem Multicore Annealed Tinned Copper Conductor, XLPE 90 C Insulated 600 V rated Cable
OHSAS 18001
AS
14001
ISO
45001 ISO 9001
ISO/TS 16949
ISO 14001
top related