surge protection solutions brochure -...
Post on 05-Mar-2018
219 Views
Preview:
TRANSCRIPT
Mersen • Surge Protection Solutions 1
Surge-Trap® Type 2 fail-safe Surge Protective Devices
Surge Protection Solutions SO
LUTI
ON
S g
UId
e
2
Reducing the impactof tRansient damage
Surge-Trap® SPD offers a patented fail-safe Type 2 solution and a superior thermal overload technology that delivers higher safety ratings and protection.
Power-related problems cost U.S. companies more than $80 billion a year. The impact is far-reaching and affects just about every aspect of business. It drives up maintenance and production costs, causes production delays, lost sales, late deliveries, as well as increased spoilage and scrap. Mersen’s Surge-Trap® Surge Protective Devices (SPD) help minimize power-related problems by protecting sensitive electrical equipment from harmful transients.
Most transients originate from within a facility and nearly 80% of today’s overvoltage problems are caused by equipment and power disturbances within the plant. These inner-facility transients are caused by light load panels switching on and off, motors starting and stopping, and close conductor proximity, just to name a few.
Less than 20% of transient problems originate outside of the facility due to lightning strikes, utility grid switching, switching of capacitor banks, and electrical accidents.
Transients cause three general types of damage to sensitive electrical equipment, for example:
• Disruptive – A voltage transient enters an electronic component which interprets the valid logic command, resulting in system lock-up, malfunctions, faulty output or corrupted files.
• Dissipative – A repetitive, short duration energy surge resulting in long-term degradation.
• Destructive – Associated with high level energy surges, resulting in immediate equipment failure (most obvious).
When exploring your surge suppression options, keep in mind that not all SPDs are created equally. If you need a space-saving option or are looking for ways to reduce costs, then consider an integrated system. Mersen’s Surge-Trap® is the only SPD featuring our patented TPMOV® technology inside.
To evaluate the safety performance of an SPD, look for compliance with IEC 61643-11, UTE C 61-740-51, UL 1449 Third Edition, RoHS, and ANSI/IEEE C62.41.
Box connectors
DIN rail mountable
Internal TPMOV®
Visual indicator
IP20 Finger-safe enclosure
1) remote indicator in option
Surge-Trap® Modular1
Remote indicator (3-pin dry contact) Color strip identifies
product type (PV, UL, IEC, etc.)
Visual indicator
IP20 Finger-safe removable plug
Internal TPMOV®
DIN rail mountable base
Surge-Trap® Pluggable
Mersen • Surge Protection Solutions 3
the unique benefits of the suRge-tRap® spdThe Surge-Trap® SPD is a fail-safeType 2 surge protective device that is easy to install or retrofit. Direct connection is available with the DIN-rail mount option. The Surge-Trap® SPD has a small foot print, visual indicator and an IP20 finger-safe design. Optional remote indicators are available when status to critical control circuits are needed.
industRies• Agriculture • Medical • Solar Power/ Photovoltaic• Telecommunication • Water Treatment • Wind Power • Transportation • Oil & Gas • Utilities• Pulp & Paper
applications• AC/DC distribution • Power supplies • Industrial automation • Telecommunications • Motor controls and starter
systems • Programmable logic controller
(PLC) applications• Power transfer equipment • HVAC applications • AC drives • UPS systems • Security systems • IT / Data centers • Medical equipment
Voltage Protection Level (Up)3: A rating per IEC 61643-11, signifying the rounded up average measured limiting voltage of an SPD when the SPD is subjected to an 8/20 μs current impulse equivalent to the SPD’s in rating.
*Short Circuit current Rating (ISCCR)4: Maximum prospective short circuit current that the surge protective device is able to withstand.
Surge Protective Device (SPD): A device that contains at least one nonlinear component and is listed to limit surge voltages and divert surge current.
8/20 current Impulse current: Impulse with a virtual front time1 of 8μs and a time to half-value2 of 20μs.
Clamp Voltage: The peak MOV terminal Voltage measured with an applied 8/20 μs pulse of rated impulse current
Metal Oxide Varistor (MOV): An electronic component that is commonly used to divert excessive current to the ground and/or neutral lines.
*Maximum Continuous Operating Voltage (MCOV or UC): The maximum rms voltage that may be continuously applied to the SPD for each connected mode.
Nominal Discharge Current (In): Peak value of the current through the SPD, selected by the manufacturer from a list of predetermined values, having a short-circuit current wave shape of 8/20 μs where the SPD remains functional after 15 surges.
appRovals/standaRds• IEC 61643-11 Class 2• pr. EN 50539-11• ANSI/IEEE C62.41• CE • RoHS compliant• UL 1449 Third Edition, File No E210793 • Type 2 UL Recognized Component (tested to SPD Type 2)
Note 1: The front time is defined according to IEC 60060-1 to be 1.25 x (t90 – t10). Note 2: The time to half-value is defined as the time between the virtual origin and the 50% point on the tail. Note 3: Up was mesured at 20kA for all SPD’s in this brochure.Note 4: Per IEC 61643-11.*Terms are referenced in the table on the reverse side.
Surge-Trap® applied in an electrical panel.
4
meeting the toughestwoRld standaRds
oveRvoltage pRotection teRms to Know
choosing the Right pRoduct is as easy as 1, 2, 3
choose youR pRoduct define the catalog numbeR
C a T a L O g N U M b e RComments on system type
Type Voltage System Type M
STP - Pluggable 230 TN Blank - No Microswitch TN System 1 line
ST- Modular 400 IT M - Microswitch Included IT system 1 line
600 TN1 TN System 1 phase + neutral
1000 TNC TNC System 3 phase + neutral
TNS TNS System 3 phase + neutral
Indicates PV Only PV Photovoltaic DC Application
1
2
3
configuRations and gRounding – iec
Agriculture Medical
Water Treatment Wind Power Transportation
Solar Power
Telecom
Automation
choose youR industRy
TT (neutral connected to earth)SinglePhase230V400V
Or
ThreePhase230/400V400/690V
TN-C wiring diagram
IT (neutral isolated or via impedance) PV
TN-S wiring diagram
Solar panels Inverter
AC
SPDSPD
DC
PE
>10m
Mersen • Surge Protection Solutions 5
oveRvoltage pRotectionsuRge-tRap®iec standaRd - ac pRotection
approvals• IEC 61643-11 Class II• EN 61643-11 Type 2• RoHS Compliant
benefits• Easy to install and retrofit• Fully fail-safe protection• World-class technology
to enhance equipment and installations
application• AC Low Voltage Distribution• Power supplies• Industrial automation• Motor controls and starter systems• Power transfer equipment• HVAC• AC drives• UPS systems• IT/Data centers• Medical equipement
Surge-Trap® Surge Protection Devices offers a patented fail-safe solution to protect against transient overvoltages.
Their superior thermal overload technology delivers higher safety ratings and protection.
Whatever they are disruptive, dissipative or destructive the damages caused by overvoltage transients are very harmful.
Surge-Trap® SPDs limit the amount of energy into the load at the lowest level avoiding the costly consequences induced by these damages.
Wiring diagrams
TN/IT TN (1 Ph + N) TNC (3 Ph + PEN) TNS (3 Ph + N)
STP/ST 230 TNC M
I I I I
STP - Pluggable Voltage System Type Auxiliary Microswitch
ST - Modular 230 TN - TN Blank - No Microswitch
400 IT - IT M - Microswitch included
600 TN1 - TN (1 Ph + N)
1000 TNC - TNC (3 Ph + PEN)
TNS - TNS (3 Ph + N)
PV - DC
Rated Voltage (V) Size With indicator Without indicator Fuseholder
400 NH00 NH00GG40V125 - BB002EPR
500 NH00 NH00GG50V125 - BB002EPR
400 22x58 cylindrical FR22GG40V125I FR22GG40V125 CMS22
6
suRge-tRap® pluggable spdsiec standaRd - ac pRotection
IeC Surge-Trap® Pluggable range DIN-Rail SPD offering
Catalog Number
Reference Number
RatedVoltage
(V)
No of Poles
MCOV(UC) L-Pe
MCOV(UC) L-N
MCOV(UC) N-Pe
MCOV(UC) L-L
Voltage Protection Level (Up @ 20 ka), (kV)
electricalstrength
(kV)
Freq(Hz)
STP230TNM H1011041C 230 1 275 N/A N/A N/A < 1.5 2.2 50/60
STP400ITM K1011043C 400 1 510 N/A N/A N/A < 2.0 2.2 50/60
STP230TN1M M1011045B 230 2 275 550 275 N/A < 1.5 2.2 50/60
STP230TNCM R1011049A 230 3 275 N/A N/A 550 < 1.5 2.2 50/60
STP230TNSM T1011051A 230 4 275 550 275 550 < 1.5 2.2 50/60
STP400TNCM E1029875A 400 3 510 510 N/A 1020 < 2.0 2.2 50/60
STP400TNSM F1029876A 400 4 510 1020 510 1020 < 2.0 2.2 50/60
environmental & Physical characteristics• Operating and storage temperature (C°): -25 to 60• Response time (ta) (ns): <25• Cross section solid (mm²): 6 to 35• Cross section flexible (mm²): 4 to 25• Terminal torque (N.m): 3.5 max• Enclosure material: UL 94 V0• Insulation resistance (MOhms): >10• Recommended gG 125A fuse for
IEC applications (contact us).
Catalog Number
RatedVoltage
(V)
Nom. Discharge
Current (In, 8/20, ka)
Max. Discharge
Current (Imax, 8/20, ka)
ISCCR(ka)
STP230TNM 230 20 40 25
STP400ITM 400 10 40 25
STP230TN1M 230 20 40 25
STP230TNCM 230 20 40 25
STP230TNSM 230 20 40 25
STP400TNCM 400 20 40 25
STP400TNSM 400 20 40 25
Surge-Trap® Microswitch Diagram
Signal Wire Range: 0.05mm2 to 1.31mm2
NO 1
Common 2
NC 3
Subminiature Switch125 VAC-3A max
• Terminal Torque 0.25N.m max• Cont. between Comm + NO = Product Offline, Not Protected• Cont. between Comm + NC = Product Offline, Protected
2.82(15.2)2
(50.7)
0.44(11.1)
3.89(98.9)
0.15(3.9)
0.35(8.9)
0.6(15.2)
0.70(17.8)
A
Poles a (mm)
1 18.03
2 36.06
3 54.10
4 72.13
Catalog Number Reference Number Rated Voltage (V) No of Poles System Type Replacement Plug Part No
STP230TNM H1011041C 230 1 TN SP275E
STP400ITM K1011043C 400 1 IT SP510E
STP230TN1M M1011045B 230 2 TN (1 Ph + N) SP275E
STP230TNCM R1011049A 230/400 3 TNC (3 Ph + PEN) SP275E
STP230TNSM T1011051A 230/400 4 TNS (3 Ph + N) SP275E
STP400TNCM E1029875A 400/690 3 TNC (3 Ph + PEN) SP510HE
STP400TNSM F1029876A 400/690 4 TNS (3 Ph + N) SP510HE
Features• DIN Rail mountable base 35mm• IP20 finger-safe removable plug• Visual indicator for plug replacement• Internal TPMOV® (Thermal Protected
Metal Oxide Varistor)
• Remote indicator (3-pin dry contact)• Small footprint• 25kA short-circuit withstand capability
Dimensional diagrams: inches and mm
Mersen • Surge Protection Solutions 7
suRge-tRap® modulaR spdsiec standaRd - ac pRotection
Features• DIN Rail mountable base 35mm• IP20 finger-safe• Internal TPMOV® (Thermal Protected Metal Oxide Varistor)• Small footprint• 25kA short-circuit withstand capability
Catalog Number Reference Number Rated Voltage (V) No of Poles System Type
ST230TN E1011061C 230 1 TN
ST400IT G1011063C 400 1 IT
ST230TN1 J1011065B 230/400 2 TN (1 Ph + N)
ST230TNC N1011069A 230/400 3 TNC (3 Ph + PEN)
ST230TNS Q1011071A 230/400 4 TNS (3 Ph + N)
Catalog Number
RatedVoltage
(V)
Nom. Discharge
Current (In, 8/20, ka)
Max. Discharge
Current (Imax, 8/20, ka)
ISCCR (ka)
ST230TN 230 20 40 25
ST400IT 400 10 40 25
ST230TN1 230 20 40 25
ST230TNC 230 20 40 25
ST230TNS 230 20 40 25
IeC Surge-Trap® Modular range DIN-Rail SPD offering
Catalog Number
Reference Number
RatedVoltage (V)
No of Poles
MCOV(UC) L-Pe
MCOV(UC) L-N
MCOV(UC) N-Pe
MCOV(UC) L-L
Voltage Protection Level (Up @ 20 ka), (kV)
electricalstrength (kV)
Freq(Hz)
ST230TN E1011061C 230 1 270 N/A N/A N/A < 1.5 3.3 50/60
ST400IT G1011063C 400 1 510 N/A N/A N/A < 2.0 3.3 50/60
ST230TN1 J1011065B 230 2 270 540 270 N/A < 1.5 3.3 50/60
ST230TNC N1011069A 230 3 270 N/A N/A 540 < 1.5 3.3 50/60
ST230TNS Q1011071A 230 4 270 540 270 540 < 1.5 3.3 50/60
Dimensional diagrams: inches and mm
0.41”10.5mm
0.70”17.8mm
WIRE MARKERLOCATION
0.27”6.9mm
1.09”27.7mm
3.58”91mm
1.77”45mm
3.82"97mm
1.93”49mm
2.7”68,5mm
0.20”5.1mm
INDICATORIN TRIPPED
POSITION
A
Poles a (mm)
1 17.8
2 35.5
3 53.3
4 71.0
environmental & Physical characteristics
• Operating and storage temperature (C°): -25 to 60• Response time (ta) (ns): <25• Cross section solid (mm²): 2.5 to 16• Cross section flexible (mm²): 1.5 to 10• Terminal torque (N.m): 1.7• Enclosure material: UL 94 V0• Insulation resistance (MOhms): >10• Recommended gG 125A fuse for IEC applications
(contact us)In option: M for microswitch, e.g:ST230TNM refer drawing page 7
In option: M for microswitch, e.g: ST230TNM refer drawing page 7
In option: M for microswitch, e.g:ST230TNM refer drawing page 7
8
oveRvoltage pRotectionsuRge-tRap®iec standaRd - pv pRotection
approvals• IEC 61643-11 Class II• EN 61643-11 Type 2• UTE C 61740-51• pr. EN 50539-11• UL1449 3rd edition• ANSI/EEE C6241• RoHS Compliant
application• Solar Photovoltaic• DC Application• Battery charge controllers• Re-combiner (sub-combiner, array combiner, master combiner)
applications
Surge-Trap® Surge Protection Devices offers a patented fail-safe solution to protect against transient overvoltages.
Their superior thermal overload technology delivers higher safety ratings and protection.
Whatever they are disruptive, dissipative or destructive the damages caused by overvoltage transients are very harmful.
Surge-Trap® SPDs limit the amount of energy into the load at the lowest level avoiding the costly consequences induced by these damages.
System type
Installation instructionsSolar panels Inverter
AC
SPDSPD
DC
PE
>10m
STP/ST 230 TNC M
I I I I
STP - Pluggable Voltage System Type Auxiliary Microswitch
ST - Modular 230 TN - TN Blank - No Microswitch
400 IT - IT M - Microswitch included
600 TN1 - TN (1 Ph + N)
1000 TNC - TNC (3 Ph + PEN)
TNS - TNS (3 Ph + N)
PV - DC
benefits• Easy to install and retrofit• Fully fail-safe protection• No additional overcurrent protection
required• World-class technology to enhance
equipment and installations
Mersen • Surge Protection Solutions 9
IeC PV Surge-Trap® Pluggable range DIN-Rail SPD offering
Catalog Number Reference Number Rated Voltage (V) No ofPoles Ucpv Voltage Protection Level
(Up @ 20 ka), (kV)electrical
strength (kV) Freq (Hz)
STP600YPVM B1015750A 600VDC 3 720VDC <2.4 2.2 DC/PV
STP1000YPVM C1015751A 1000VDC 3 1200VDC <4.0 2.2 DC/PV
CatalogNumber
RatedVoltage
(V)
Nom. DischargeCurrent
(In, 8/20, ka)
Max. DischargeCurrent
(Imax, 8/20, ka)
ISCCR(ka)
STP600YPVM 600VDC 20 40 10kA*
STP1000YPVM 1000VDC 20 40 10kA
environmental & Physical characteristics
• Operating and storage temperature (C°): -25 to 60
• Response time (ta) (ns): <25• Cross section solid (mm²): 6 to 35• Cross section flexible (mm²): 4 to 25• Terminal torque (N.m): 3.5 max• Enclosure material: UL 94 V0• Insulation resistance (MOhms): >10
suRge-tRap® pluggable spdsiec standaRd - pv pRotection
Features• DIN Rail mountable base 35mm• IP20 finger-safe removable plug• Visual indicator for plug replacement• Internal TPMOV® (Thermal Protected
Metal Oxide Varistor)
Surge-Trap® Microswitch Diagram
Signal Wire Range: 0.05mm2 to 1.31mm2
NO 1
Common 2
NC 3
Subminiature Switch125 VAC-3A max
• Terminal Torque 0.25N.m max• Cont. between Comm + NO = Product Offline, Not Protected• Cont. between Comm + NC = Product Offline, Protected
2.82(15.2)2
(50.7)
0.44(11.1)
3.89(98.9)
0.15(3.9)
0.35(8.9)
0.6(15.2)
0.70(17.8)
A
Poles a (mm)
1 18.03
2 36.06
3 54.10
4 72.13
Dimensional diagrams: inches and mm
• Remote indicator (3-pin dry contact)
• Small footprint• 25kA short-circuit withstand capability
Catalog Number Reference Number Rated Voltage (V) No of Poles System Type Replacement Plug Part No
STP600YPVM B1015750A 600VDC 3 Y SP420PV
STP1000YPVM C1015751A 1000VDC 3 Y SP670PV
10
CatalogNumber
ReferenceNumber
RatedVoltage (V)
No ofPoles
SystemType
ST600PV Y1007421A 600VDC 2 V
ST600YPV G1029877A 600VDC 3 Y
ST1000PV N1004353A 1000VDC 3 Y
IeC PV Surge-Trap® Modular range DIN-Rail SPD offering
Catalog Number Reference Number Rated Voltage (V) No ofPoles Ucpv Voltage Protection Level
(Up @ 20 ka), (kV)electrical
strength (kV) Freq (Hz)
ST600PV Y1007421A 600VDC 2 720VDC <2.0 3.3 DC/PV
ST600YPV G1029877A 600VDC 3 720VDC <2.5 3.3 DC/PV
ST1000PV N1004353A 1000VDC 3 1200VDC <4 3.3 DC/PV
CatalogNumber
RatedVoltage
(V)
Nom. DischargeCurrent
(Inom, 8/20, ka)
Max. DischargeCurrent
(Imax, 8/20, ka)
ISCCR(ka)
ST600PV 600VDC 10 40 10kA
ST600YPV 600VDC 20 40 10kA
ST1000PV 1000VDC 10 40 10kA
environmental & Physical characteristics
• Operating and storage temperature (C°): -25 to 60
• Response time (ta) (ns): <25• Cross section solid (mm²): 2.5 to 16• Cross section flexible (mm²): 1.5 to 10• Terminal torque (N.m): 1.7• Enclosure material: UL 94 V0• Insulation resistance (MOhms): >10
Dimensional diagrams: inches and mm
0.41”10.5mm
0.70”17.8mm
WIREMARKERLOCATION
0.27”6.9mm
1.09”27.7mm
3.58”91mm
1.77”45mm
3.82"97mm
1.93”49mm
2.7”68,5mm
0.20”5.1mm
INDICATORIN TRIPPED
POSITION
A
Poles a (mm)
2 35.5
3 53.3
suRge-tRap® modulaR spdsiec standaRd - pv pRotection
Features
• DIN Rail mountable base 35 mm• IP20 finger-safe• Internal TPMOV® (Thermal Protected Metal
Oxide Varistor)• Small footprint• 25kA short-circuit withstand capability
In option: M for microswitch, e.g:ST600PVM refer drawing page 10
In option: M for microswitch, e.g:ST600PVM refer drawing page 10
In option: M for microswitch, e.g:ST600PVM refer drawing page 10
Mersen • Surge Protection Solutions 11
Main production sites
Industrial or commercial branch
A WORLD LEADERin safety & reliabilityfor electrical power
a gLObaL PLaYeRMersen designs innovative solutions to address its clients’ specific needs to enable them to optimize their manufacturing process in sectors such as Energy, Transportation, Electronics, Chemical, Pharmaceutical and Process Industries.
Global expert in materials and equipment for extreme environments and in the safety
and reliability of electrical equipment.
Mersen France SB S.A.S.
Rue Jacques de Vaucanson F-69720 Saint-Bonnet-de-Mure Tel : + 33 4 72 22 66 11 www.mersen.com
MERSEN Shanghai Co. Ltd.
No.55-A6. Shu Shan Road,Songjiang201611 ShanghaiTel: +8621 67602388 www.mersen.com
MERSEN USA Newburyport-MA L.L.C.
374 Merrimac Street Newburyport, MA 01950 Phone: 978-462-6662 www.mersen.com
- 72
28 -
BR
-STE
-002
-021
2
top related