terrart_brochure_en
Post on 21-Mar-2016
224 Views
Preview:
DESCRIPTION
TRANSCRIPT
NBK Ceramic GmbH & Co.KG
Reeser Straße 235
D-46446 Emmerich
Germany
Phone +49 (0) 28 22 / 81 11-0
Fax +49 (0) 2822 / 81 11-20
E-mail: info@nbk.de
NBK (UK) Office
John Wimbush
PO Box 6779 · Ripley · Derbyshire, DE5 8YQ
Phone +44 (0) 1773 512 363
Fax +44 (0) 1773 512 644
E-mail: john@nbk-uk.com
www.nbk.de
ARC
HIT
ECTU
RA
L TE
RR
AC
OT
TA
GB
NBK CeramicARCHITECTUR AL TERR ACOT TA
NBK CeramicARCHITECTUR AL TERR ACOT TA
Technikband GB_05 17.08.2006 9:50 Uhr Seite 1
ARCHITECTURAL TERRACOTTA
1
1 Potsdamer Platz, Berlin / DArchitects: Renzo Piano Building Workshop
2 AIG European Headquarters, London / GBArchitects: KPF London / New York
3 Landesbank Baden-Württemberg, Stuttgart / DArchitects: WWA Architects Stuttgart / Munich
4 Sammon Keskuslukio / FINArchitects: Arkkit. TSTO OP Jokela Ltd., Helsinki
5 Center for Government and International Studies, HarvardUniversity, Boston / USAArchitects: Pei Cobb Freed & Partners, New York
6 Evelina Children’s Hospital, London / GBArchitects: Hopkins Architects
7 City Square, Liverpool / GBArchitects: GM Architects
8 Hilton Hotel, London / GBArchtects: Jestico + Whiles
5
2
3
2 3
6
4
8
7
TERRART®
Technikband GB_05 17.08.2006 9:51 Uhr Seite 3
ARCHITECTURAL TERRACOTTA4 5
1 Temple House, Birmingham / GBArchitects: GMW
2 Office Development, Farnborough / GBArchitects: Allies and Morrison
3 Telford College, Edinburg / GBArchitects: HOK
4 Bilborough College, Nottingham / GBArchitects: CPMG
5 Oldham College, Oldham / GBArchitect: Pringle Richards Sharrat
6 Bio-Medical, Glasgow / GBArchitects: Boswell Mitchell Associates
7 Jamaica Street Car Park, Glasgow / GBArchitects: Farrell & Clarke
8 Eastburne Terrace, London / GBArchitects: Fletcher Priest
1
5
6
2
4
7
3
8
TERRART®
Technikband GB_05 17.08.2006 9:51 Uhr Seite 5
ARCHITECTURAL TERRACOTTA6 7
1 Natural History Museum, London / GB.Architects: HOK Architects London
2 New Art Galery, Walsall / GB.Architect: Caruso St. John
3 Vodafone World Headquarter, Newbury / GB.Architect: Fletcher Priest London
4 Parliament View, London / GB.Architects: EPR Architects London
5 Royal Infirmary, Manchester / GB. Architects: Pulmann Associates
6 Riverside Houe, London / GB. Archtects: RHWL Architects London
7 Office building Davies Street, London / GB.Architechts: KPF Architects, London
1
2
6
3
5
4
7
TERRART®
Technikband GB_05 17.08.2006 9:52 Uhr Seite 7
Medium-sized format ceramic elements
Hollow chamber cross-section with a thickness of 30 mm.
Variable heights and lengths on request.
Height: max. 300 mm
Length: max. 1,200 mm
Special feature: also available as regular curved cross-
section R ≥ 6 m
Surface: smooth, polished, textured or peeled, curved
surfaces only: smooth, textured or peeled
Mass per unit area: approx. 55 kg/m2
Solid ceramic elements
Solid ceramic cross-section with a thickness of 30 mm for
use as a prefab facing element or as a mounted façade
system. Calibrated on two sides or all sides.
Height: max. 600 mm
Length: max. 1,200 mm
Variable heights and lengths
Mass per unit area: approx. 65 kg/m2
TERRART®-SOLID
Large format ceramic elements
Hollow chamber cross-section with a thickness of 40 mm.
Variable heights and lengths on request.
Height: max. 600 mm
Length: max. 1,800 mm
Special feature: also available as regular curved cross-
section R ≥ 6 m
Surface: smooth, polished, textured or peeled, curved
surfaces only: smooth, textured or peeled
Mass per unit area: approx. 65 kg/m2
Ceramic shingle
Hollow chamber cross-section with a thickness of 40 mm.
Variable heights and lengths on request.
Height: max. 600 mm
Length: max. 1,800 mm
Surface: smooth, polished, textured or peeled
Mass per unit area: approx. 65 kg/m2
TERRART®-SHINGLETERRART®-MIDTERRART®-LARGE 8 9
Technikband GB_05 17.08.2006 9:53 Uhr Seite 9
Ceramic square pipes
The TERRART®-Baguette is one of the ceramic variants.
Its minimum cross-section is 40 x 40 mm. The cross-
section of the most common format is 50 x 50 mm.
Special feature: also available as regular curved cross-
section R ≥ 6 m.
Surface: smooth, ground, textured as double-baguette or
peeled, curved surfaces: smooth only.
Weight: approx. 5 kg per running metre for baguettes
50 x 50 mm, approx. 2.5 kg per running metre for
baguettes 40 x 40 mm.
A multitude of profiles are available for the surface design
of the TERRART® ceramic elements. The broad design
spectrum ranges from the finest structure up to the strongly
profiled plastic relief. Natural surfaces, horizontal profiles
and peeled surfaces are part of our standard program. In
addition, TERRART® façades can also be designed with
individual profiles and surfaces.
TERRART®-PROFILESTERRART®-BAGUETTE10 11
The range of TERRART® products offers numerous other
ceramic variants.
On an individual basis, custom production is possible for a
particular property, through to elements with varying radii
for the creation of elliptic shapes. Production is carried out
according to specifications, also as a hand-made single
element if required. All bonded single elements must ad-
ditionally be fixed mechanically on the construction site
(by the customer) in accordance with DIN 18516 part 3,
point 3.2 (both sides in the case of corners, on three sides
in the case of U-shaped elements).
TERRART®-VARIANTS
Technikband GB_05 17.08.2006 9:54 Uhr Seite 11
natural surface
1.01-0
4.01-0
6.02-0
8.01-0
honed surface
1.01-1
2.01-0 2.01-1
3.01-0 3.01-1
4.01-1
5.01-0 5.01-1
6.01-0 6.01-1
6.02-1
7.03-0 7.03-1
7.04-0 7.04-1
8.01-1
9.04-0 9.04-1
glaze surface
12 13
Remark: All other formats, dimensions and special sizes are available on inquiry basis. Subject change without notice. NBK, February 2006
water absorptioncolour:1.01-0 Arezzo white2.01-0 Molino light yellow 5.01-0 Torrita terra cotta red6.01-0 Siena red
EN ISO 10545 part 12
4.5 - 6.0 %4.0 - 5.7 %4.3 - 6.3 %4.3 - 6.4 %
bending tensile strengthcolour:1.01-0 Arezzo white2.01-0 Molino light yellow 5.01-0 Torrita terra cotta red6.01-0 Siena red
EN ISO 10545 part 4(replaces EN 100)
13 - 20 N/mm2
17 - 24 N/mm2
15 - 25 N/mm2
14 - 20 N/mm2
dimensions and tolerances
width400 mm to 1,450 mm
height150 mm to 500 mm(colour M 6.01-0 and M 6.02-0just to max. 450 mm)
thickness30 mm or 40 mm
straightness in hole direction
diagonal flatness
vertical flatness cross to hole direction
torsion
center in hole direction
opposite to hole direction
DIN EN ISO 10545-2deviation if surface is honed
DIN EN ISO 10545-2
DIN EN ISO 10545-2
DIN EN ISO 10545-2
DIN EN ISO 10545-2
+/- 1.0 mm for cuts
+/- 2.0 mm to 250 mm+/- 2.5 mm to 400 mm+/- 3.0 mm to 500 mm
+/- 1.5 mm
+/- 0.25 % of length
+/- 0.25 % of diagonal
+/- 1.0 % of height
+/- 0.25 % of diagonal
linear thermal expansion∆t = 100°C
EN ISO 10545 part 8(replaces EN 103)
< 0.4 mm referring to a length of 1,000 mm
freeze / thaw resistance EN ISO 10545 part 12(100 cycles)
fulfilled
efflorescence and soluble salts DIN 105 part 1 well below the permittedmaximum limit
chemical resistance DIN 105 part 4 fulfilled
raw density 2.09 - 2.16 kg/dm3
compressive strength 36.5 - 66.5 N/mm2
TECHNICAL DATA SHEET FOR UNGLAZED NATURAL TERRA COTTA TILES COLOURS AND SURFACES
TERRART® glazes and honed finishes are being
increasingly exploited as a design feature in
contemporary architecture. NBK's expertise in compli-
cated mixing techniques and traditional
firing methods, allows virtually any colour and
surface texture specification to be met to the letter. This
allows our company, in consultation with designers of
exclusive product assortments, to make unique buildings.
The colors shown represent only a few of our overall
range. Any required shade can be provided upon
request.
Technikband GB_05 17.08.2006 9:54 Uhr Seite 13
14 15THE RAINSCREEN SYSTEM
The NBK TERRART® ceramic clay tile façade system,
which is based on the rainscreen principle, is custom
designed and engineered.
The vertical joints are backed by a support system which
drains rainwater away from the cavities behind. The
gaskets, together with balanced air pressure, discourages
water from entering the wall cavities.
The tile design allows for air to flow through „open
joints“, which helps to balance air pressure in the cavities
behind the terra cotta cladding elements with that of
outside air, hence, the term – pressure equalization.
Driven rainwater will not enter the cavities because of
the overlapping joints („protected openings“) and lack
of pressure differential.
The „back ventilation“ assists in maintaining a dry cavity
and negates the build up of hot air, an additional benefit
to the TERRART® rainscreen system.
TERRART®-FLEX-SYSTEM
Technikband GB_05 17.08.2006 9:55 Uhr Seite 15
16 17
VERTICAL WINDOW SOFFIT
HORIZONTAL SECTION
VERTICAL SECTION
TERRART®-Large
TERRART®-Large
TERRART®-Large
Spacer profileTile holder
T2 vertical profile
Module
Mod
ule
Mod
ule
Mod
ule
Mod
ule
Module
Plugs suitable for the statics of the building
Height displaced plug
Heat insulation
Heat insulation
T1 vertical profile
Tile holder
PinJoint profile
Heat insulation
Heat insulation
HORIZONTAL SECTION WINDOW SOFFIT
Technikband GB_05 17.08.2006 9:55 Uhr Seite 17
18 19TERRART® BAGUETTE SYSTEMDETAIL EXTERNAL CORNER
DETAIL INTERNAL CORNER
Height displaced plug
Module Module
Mod
ule
ModuleTERRART-Large
T1 vertical profile
Joint profile
Heat insulation
Pin
Tile holder
Technikband GB_05 17.08.2006 9:55 Uhr Seite 19
20 21TERRART®-BAGUETTETERRART®-BAGUETTE
Technikband GB_05 17.08.2006 9:56 Uhr Seite 21
22 CONVINCING FAÇADESPACKING AND SHIPPING
For shipping and transport, NBK provides packing of all
terra cotta elements in custom made heavy duty wooden
crates or on pallets. All pieces are carefully packed;
fibreboard and styrofoam are used as spacers so that the
tiles cannot touch each other.
This packing will limit damage during shipping and trans-
port under normal conditions.
The advantages of the TERRART® product series are
appreciated by an ever increasing number of architects.
The versatility and the almost limitless applicability of the
terra cotta façade elements open up possibilities that
creative and innovative designers need to realize their ideas.
23
For further information on trends,
technical developments
and current construction projects
please visit our web site at: www.nbk.de
PROGRESS THROUGH DIVERSITY
Technikband GB_05 17.08.2006 9:56 Uhr Seite 23
top related