LEDLab, Gosford
Sylvania Way,
Lisarow NSW 2250 AustraliaPh (61) 2 4328 0678
or 0409661972
email sales@ledlab.com.au
The Actual Lumen Maintenance Life is not guaranteed by this laboratory it is merely a standardised method of extrapolation. The data specified in this report relates to the sample measured under standard conditions specified in the Test Specification, and may not necessarily relate to other similar luminaires or other operating conditions. The tests and measurements covered by this document are traceable to Australian national standards of measurement. This report shall only be reproduced in full unless approved in writing by Light Emission Distribution Laboratory (LEDLab).
Page 1 of 9
Accredited for compliance with ISO/IEC 17025Accreditation No. 19541
Test Report: 216181
In-Situ Temperature Measurement Test (ISTMT) for
Lumen Maintenance Life of BSSLED Australia
luminaire in accordance with IES TM-21-11
by the method of IES TM 21 (lumen depreciation method), IES LM 84-14 (Annex A) and AS/NZS 60598.2.1:2014
Prepared for: BSSLED
Model:61900-90
Test Report: 216181
LEDLab, Gosford
Sylvania Way,
Lisarow NSW 2250 Australia
Ph (61) 2 4328 0678
or 0409661972
email sales@ledlab.com.au
The Actual Lumen Maintenance Life is not guaranteed by this laboratory it is merely a standardised method of extrapolation. The data specified in this report relates to the sample measured under standard conditions specified in the Test Specification, and may not necessarily relate to other similar luminaires or other operating conditions. The tests and measurements covered by this document are traceable to Australian national standards of measurement. This report shall only be reproduced in full unless approved in writing by Light Emission Distribution Laboratory (LEDLab).
Page 2 of 9
Product
Luminaire Type: HiBay
Name of Product: 90w LED High Bay Model/Catalogue number: 61900-90
Description: Suspended IP65 Hibay Black Body Glass lens 195mm
LED Brand Name/ Model No: Osram DURIS S 5 GW PSLR31.EM
Driver Brand name/Model No: Osram Optronic OT 165/170-240/1A0 4DIMLT2 E
Results
Supply Voltage 254.0V (1.06x rated voltage) 50Hz, Current 0.345A and Power 83.6 W at 0.955 Power Factor.
In-Situ Temperature Measurement Test (ISTMT) on LED measuring point 59 Deg C
Total driver output current being supplied to panel 560 mA.
Consideration of LED arrangement, yields an LED drive current of maximum 70mA. Note that the drive current
employed in the LM80 report is 160mA.
Conclusion
The calculator below gives a projected 70% lumen maintenance life under normal operating conditions of 61,100
hours, however, according to IES TM-21-11 the luminaire manufacturer can only claim “6 times the test hours” or
54000 hours. At 54000 hours of life, the lumen maintenance is projected as 73.15%.
Client:
BSSLED
Tested by: Alain Yetendje On: 08/08/2016 Authorised Signatory
Alain Yetendje
Date: 08/08/2016
Test Report: 216181
LEDLab, Gosford
Sylvania Way,
Lisarow NSW 2250 Australia
Ph (61) 2 4328 0678
or 0409661972
email sales@ledlab.com.au
The Actual Lumen Maintenance Life is not guaranteed by this laboratory it is merely a standardised method of extrapolation. The data specified in this report relates to the sample measured under standard conditions specified in the Test Specification, and may not necessarily relate to other similar luminaires or other operating conditions. The tests and measurements covered by this document are traceable to Australian national standards of measurement. This report shall only be reproduced in full unless approved in writing by Light Emission Distribution Laboratory (LEDLab).
Page 3 of 9
Test specifications
The luminaire was tested in accordance with the procedures given in IES LM-84-14, "IES Approved Method for
Measuring Luminous Flux of LED Luminaires" using the In-Situ Temperature Measurement Test (ISTMT) referred
to in IES TM-21-11 “Projecting Long Term Lumen Maintenance of LED Light Sources". In particular, the method
of Test is described in IES LM-84-14 Annex A Recommendations for Measurement of In-Situ conditions LED Case
Temperature, TS. In addition, the conditions of test are as specified in AS/NZS 60598.2.1:2014 Clause A17; this
refers to Clause 12.4 of AS/NZS 60598.1.
Use has been made of IES LM-80-2008 test report Test Documentation No.: Osram Test Document no: 160022W1,
Osram Opto Semiconductors and the Energy Star Calculator Spreadsheet based around IES TM-21-11. This method
is the preferred Option 1 in Appendix 1 – US Department of Energy –Guide to evaluating LED lumen
maintenance.pdf.
The data specified in this report apply to the luminaire with the components nominated and only if it uses the LED
package described in the above LM-80 report, and will not be applicable to the use of other LED sizes or ratings,
other drive Currents, nor to any other luminaire of similar design.
Test Configuration & Method
The luminaire was measured for LED Chip temperature at the point marked TMPLED on the DURIS S 5
GW PSLR31.EM chip by the laboratory as this is specified in the Test Documentation No.: 160022W1 – 3rd
February 2016.
• The Report gave chip dimensions Illustration 1 this laboratory concluded the yellow section of the chip
measures 3.3 mm long by 3.1 mm wide. The chips in the luminaire were inspected and measured in Length
3.3 mm long by 3.1 mm wide. This laboratory concludes the chip is the same shape and size as shown in the
Report but cannot be held responsible that the chip is the same. Responsibility for this rests with the
luminaire supplier.
• The luminaire as supplied by the client was tested in the controlled temperature room at 40 Deg C as it was
marked Ta = 40°C.
• The luminaire was hung facing down as it is constructed with suspension points.
• The LED was measured with a fine 36-gauge Type K thermocouple glued with two part clear epoxy to the
TMF point in the Report, see Illustrations 1 and 2.
• A calibrated reference thermometer together with the thermocouple of total Uncertainty 0.4 Deg C was used to
take this measurement.
Test Report: 216181
LEDLab, Gosford Sylvania Way, Lisarow NSW 2250 Australia
Ph (61) 2 4328 0678 or 0409661972
email sales@ledlab.com.au
The Actual Lumen Maintenance Life is not guaranteed by this laboratory it is merely a standardised method of extrapolation. The data specified in this report relates to the sample measured under standard conditions specified in the Test Specification, and may not necessarily relate to other similar luminaires or other operating conditions. The tests and measurements covered by this document are traceable to Australian national standards of measurement. This report shall only be reproduced in full unless approved in writing by Light Emission Distribution Laboratory (LEDLab).
Page 4 of 9
Luminaire Thermocouples
Test Equipment used
Room Ambient thermometer: AMA 136 2983 0.1degC Serial No 526,10942
Temperature Data Logger: AoiP TC-TM6602 Serial No:WEM41021-002B
Current Data logger: Agilent 34970A Serial No: MY44014871, Agilent 34901A 20 Channel
Multiplexer: Serial No: MY41055589 used to determine driver output current
.
llustration 1: LED chip as shown
Test Report: 216181
LEDLab, Gosford Sylvania Way, Lisarow NSW 2250 Australia
Ph (61) 2 4328 0678 or 0409661972
email sales@ledlab.com.au
The Actual Lumen Maintenance Life is not guaranteed by this laboratory it is merely a standardised method of extrapolation. The data specified in this report relates to the sample measured under standard conditions specified in the Test Specification, and may not necessarily relate to other similar luminaires or other operating conditions. The tests and measurements covered by this document are traceable to Australian national standards of measurement. This report shall only be reproduced in full unless approved in writing by Light Emission Distribution Laboratory (LEDLab).
Page 5 of 9
and with additional thermocouples to ensure stability is achieved.
Illustration 3: TM21 inputs ( projected 70% lumen life)
Test Report: 216181
LEDLab, Gosford Sylvania Way, Lisarow NSW 2250 Australia
Ph (61) 2 4328 0678 or 0409661972
email sales@ledlab.com.au
The Actual Lumen Maintenance Life is not guaranteed by this laboratory it is merely a standardised method of extrapolation. The data specified in this report relates to the sample measured under standard conditions specified in the Test Specification, and may not necessarily relate to other similar luminaires or other operating conditions. The tests and measurements covered by this document are traceable to Australian national standards of measurement. This report shall only be reproduced in full unless approved in writing by Light Emission Distribution Laboratory (LEDLab).
Page 6 of 9
Illustration 4: TM21 inputs ( lumen maintenance at 54000 hours)
Test Report: 216181
LEDLab, Gosford Sylvania Way, Lisarow NSW 2250 Australia
Ph (61) 2 4328 0678 or 0409661972
email sales@ledlab.com.au
The Actual Lumen Maintenance Life is not guaranteed by this laboratory it is merely a standardised method of extrapolation. The data specified in this report relates to the sample measured under standard conditions specified in the Test Specification, and may not necessarily relate to other similar luminaires or other operating conditions. The tests and measurements covered by this document are traceable to Australian national standards of measurement. This report shall only be reproduced in full unless approved in writing by Light Emission Distribution Laboratory (LEDLab).
Page 7 of 9
Additional Information on LEDLab NATA Accreditation, see last page for accreditation of this report.
Test Report: 216181
LEDLab, Gosford Sylvania Way, Lisarow NSW 2250 Australia
Ph (61) 2 4328 0678 or 0409661972
email sales@ledlab.com.au
The Actual Lumen Maintenance Life is not guaranteed by this laboratory it is merely a standardised method of extrapolation. The data specified in this report relates to the sample measured under standard conditions specified in the Test Specification, and may not necessarily relate to other similar luminaires or other operating conditions. The tests and measurements covered by this document are traceable to Australian national standards of measurement. This report shall only be reproduced in full unless approved in writing by Light Emission Distribution Laboratory (LEDLab).
Page 8 of 9
Test Report: 216181
LEDLab, Gosford Sylvania Way, Lisarow NSW 2250 Australia
Ph (61) 2 4328 0678 or 0409661972
email sales@ledlab.com.au
The Actual Lumen Maintenance Life is not guaranteed by this laboratory it is merely a standardised method of extrapolation. The data specified in this report relates to the sample measured under standard conditions specified in the Test Specification, and may not necessarily relate to other similar luminaires or other operating conditions. The tests and measurements covered by this document are traceable to Australian national standards of measurement. This report shall only be reproduced in full unless approved in writing by Light Emission Distribution Laboratory (LEDLab).