the experts for industrial sealing ... - mechanical seal india seal.pdf · hi- tech seal pvt. ltd....

Post on 05-Jun-2018

232 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

The Experts for industrial The Experts for industrial Sealing technologySealing technology

Hi- Tech Seal Pvt. Ltd. 2002

Ankleshwar 15,000

Hi- Tech

Hi- Tech

Introduction...

HTS /open

HTS /Close

HTS /50U

HTS /MG1

HTS /53U

HTS /12,13

HTS /20M

HTS /20R

HTS /20C

HTS /20S

HTS /M44

HTS /M45

HTS /M65

HTS /M46

HTS /M65S

HTS /87U

HTS /87W

HTS /150

HTS /2U

HTS /80A

HTS /80B

HTS /M70W-1

HTS /M70W-4

HTS /85U

HTS /80B

HTS /150S

HTS /2W

HTS /2WW

HTS /82B

HTS /82W

HTS /80IBO

HTS /80IBV

HTS /80UU

HTS /75U

HTS /M70W-2

HTS

HTS 80B

HTS /90 B 31

HTS /90 B 32

HTS /90 B 335

HTS /90 B 345

HTS /90 B 38

HTS /90 B 36

HTS /90 B 39

HTS /90 B 35

HTS /90 B 35D

NOTERecirculation From Pump Case Through Orice and Cooler to SealConnections ‘1’ For Flushing Inlet.

API Plan 21

NOTERecirculation From Seal with Pumping Ring Through Cooler and BACK to SealConnection ‘1’ & ‘2’ for Circulation Inlet & Outlet

API Plan 23

NOTERecirculation From Seal with Pumping Ring Through Cooler and BACK to SealConnection ‘1’ & ‘2’ for Circulation Inlet & Outlet

API Plan 23

NOTERecirculation From Pump case Through clone separator Delivering Clean FluidThrough Cooler to Seal & Fluid with Solids Back to Pump Suction Connection ‘1’ For Flushing Inlet

API Plan 31

API Plan 32

NOTEConnection ‘1’ For Flushing InletExternal Liquid Mixes in the Pump MediaInjection to seal From External Source of Clean LiquidThe Purchase Will Specify The Fluid Characteristics and The Vendor Shall Specify Volume Pressure & Temperature Required

API Plan 41

NOTEConnection ‘1’ For Flushing InletRecirculation From Pump Case Through Cyclone Separator Delivering Clean Fluid Through Cooler to Seal & Fluid with Solids Back to Pump Suction

API Plan 52

NOTEConnections ‘1’& ‘2’ For Flushing inlet & Outlet for Out Board Seal Non Pressurized Thermosyphon

NOTEConnection ‘1’ & ‘2’ For Flushing Inlet & Outlet For Outboard Seal

API Plan 53

NOTEConnection ‘1’ & ‘2’ For Flushing Inlet & Outlet

API Plan 54

NOTEConnection ‘1’ & ‘2’For Vent & Dran

API Plan 61

NOTEConnection ‘1’ & ‘2’For Quenching Inlet & Outlet

API Plan 61

API Plan 1

API Plan 2

API Plan 11

API Plan 13

Note

Flushing Connection need not be Provided in the Gland Plate

NOTE Recirculation From Seal Chamber Through Orice & Back to Pump SuctionConnections ‘1’ For Flushing Liquid Circulation

NoteDead Ended Seal Box With No Circulation of Flushed Fluid, Water CooledStufng Box Jacket & Throat Bushing Required When SpeciedConnections ‘1’ & ‘2’ Plugged for Possible Future Circulation

NoteRecirculaton From Pump Case Though Orice To SealConnection ‘1’ For Flushing Inlet

Integral ( Internal ) Connection for Flushing Exists in The Stufng Box

HTS / 90 B 39

HTS / 90 B 38

HTS / 90 B 37

HTS / 90 B 42

HTS / 90 B 33D

Model : HTS /SD3 Model : HTS /DS 3A

Model : HTS /SD2

Model : HTS /SH3

Model : HTS /SH4

Model : HTS /DS 2A

Model : HTS /DS 1

Model : HTS /SH3A

Model : HTS /DB5

Model : HTS /SH4A

REFURBISHMENT OF EAGLE - BURGMANN, FLOWSERVE ( FSL), LEAK -PROOF FLEXIBOX, SEALOL, PILLAR, EKATO, SUMIKA, ROLON SEALS

Tra

ns

Prin

ters

@ 9

42

63

34

91

8 /

99

78

10

73

92

Unit -I

Marketing Location : Dahej, Vadodara, Ahemdabad, Surat, Vapi, Mumbai, Pune, Hydrabad, Goa, Chennai, Delhi,

Baddi, Indore,Panipat, Haridwar, Dehradun, Ludhiana, J&K.....

Plot No. -3, Opp. India Hotal,Rajosana Ahemdabad Palanpur Highway, Chapi - 385210 Tal Vadgam, Dist - B.K. Gujarat

Unit -I

top related