thermasheath 3 roof wall insulation for the building ... · pdf filere-siding construction -...

Post on 06-Feb-2018

214 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

TRANSCRIPT

PRODUCT DESCRIPTIONRmax Thermasheath-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded to reinforced aluminum foil facers on each side. Thermasheath-3 utilizes a CFC-, HCFC- and HFC-free blowing agent that has zero Ozone Depletion Potential (ODP) and negligible Global Warming Potential (GWP). This insulation is suitable for use in walls, ceilings and some limited roofing applications in new construction for commercial, residential, agricultural and industrial buildings and in thermal retrofit construction within existing buildings.

COmPlIaNCES• ASTMC1289TypeI,Class1• InternationalBuildingCode(IBC)Section2603,FoamPlastic

• ASHRAE90.1• ESR-1864,ICCEvaluationService• InternationalEnergyConservationCode(IECC)• Miami-DadeCountyProductControlApproved• RR25322,CityofLosAngelesResearchReport• CaliforniaCodeofRegulations,Title24• CanadianConstructionMaterialsCentreEvaluation#CCMC13381-L,manufacturedtoconformto

CAN/ULC-S704-03Type1,Class1• AirBarrierMaterialperASTME2178• 1,2,3or4hourFireRatedAssembliesasshown

intheULFireResistanceDirectory.• DesignNo.:U026,U326,U330,U354,U424,U460,U902,U904,U905,U906,U907,V454,V499

CONSTRUCTION aPPlICaTIONS• Studwalls;cavitywalls;masonrywalls;exteriorstucco;re-siding;vaultedceilings;atticsandcrawlspaces;concretefoundations;limitedroofingapplications

PRODUCT bENEfITS• Reducesenergycosts• ContributestowardLEED® credits• Offerstaxcredits,whereapplicable

Thermasheath®-3Insulation for the building Envelope

ROOF

WALL

SPECIALTY

THERmal PROPERTIES / PRODUCT DaTa “R”meansresistance toheat flow.Thehigher theR-value, thegreaterthe insulating power.

NominalThickness

ThermalR-Value1 SystemR-Value2 Pcs/Bdl

Inches °F•ft2•hr/Btu °F•ft2•hr/Btu

0.50 3.2 5.97 960.75 5.0 7.77 601.00 6.0 8.77 481.50 9.6 12.37 322.00 13.1 15.87 242.50 16.7 19.47 193.00 20.3 23.07 163.50 23.9 26.67 134.00 27.4 30.17 124.50 31.0 33.77 10

1ThermalvaluesaredeterminedbyusingASTMC518testmethodat75°FmeantemperatureonmaterialconditionedaccordingtoPIMATechnicalBulletinNo.101. 2IncludestheASHRAEassigned2.77R-valueofa3/4inchdead-airspaceagainstareflectivefoilinatypicalwallassembly.

AdditionalthermalR-valuescanbefoundontheinserttothisdocument.Thermasheath-3 is shipped in bundles that are approximately 48 inchhighandwrappedinplasticforeasyhandling.Visitwww.rmax.com for a complete list of thicknesses and packaging information.

TYPICal PHYSICal PROPERTIESPhysical properties shown are based on data obtained under controlled conditions and are subject to normal manufacturing tolerances.

Property TestMethod ResultsDensity,Overall,Nominal ASTMD1622 2.0pcfCompressiveStrength ASTMD1621 20psi1

FlameSpread,Core2 ASTME84 75orLessSmokeDeveloped,Core2 ASTME84 <450

WaterVaporTransmission ASTME96 <0.3permWaterAbsorption ASTMC209 <1%Vol.DimensionalStability ASTMD2126,

7days,158°F,98%RH<2%LinearChange

ServiceTemperatures -40°Fto+250°F1Alsoavailablein25psiuponrequest.Lessthan1inchisonlyavailableat16psi. 2Flame spread and smoke numbers are shown for comparison purposes only and are not intended to represent the performance of Thermasheath-3 and related components under actual fire conditions.

2015-08

Masonry Wall Construction - Thermasheath-3 is applied to either the exterior or interior face of concrete or concrete masonry walls to providealayerofcontinuousinsulation(ci)overtheentiresurface.Itmaybe secured to the inside face of a concrete or concrete masonry wall, over or under the furring strips, and coveredwith aminimum1/2 inchgypsumwallboardinteriorfinish.Adhesives,screwsornailsmaybeusedto hold the Thermasheath-3 in place against the wall temporarily, until the furring strips and gypsum wallboard are installed. The furring strips and gypsum wallboard must be secured with suitable screws or nails.

05Masonary Wall ConstructionThermasheath-3 Interior Application A1.00

THERMASHEATH - 3

1/2" GYSUM WALLBOARD

TREATED WOODFURRING 16" O.C.

CMU WALL

TREATED WOODFURRING AT BASE

TREATED WOODEND CAP

FOUNDATION WALL

Exterior Stucco Construction - Thermasheath-3 may be used as the insulative sheathing under hard coat stucco finishes.It may be secured to the studs with bugle-head screws, galvanizedroofing nails or common-nails driven through cap washers. Cover theThermasheath-3 with a suitable separation layer such as an organic or inorganic felt. Then, attach conventional metal wire lath andexpansion joints with appropriate fasteners as dictated by the local Building Code. Rmax does not recommend the direct attachment ofstucco, such as Portland cement or polymer-modified types, directly to the face of the insulation product. Consult stucco manufacturers for details.

06Stucco ConstructionThermasheath-3 Exterior Application A1.00

THERMASHEATH - 3

ORGANIC / INORGANICFELT

METAL FLASHING

HARD COAT STUCCO

FOUNDATION WALL

SUBFLOORING &FLOOR FRAMING

TERMITE SHIELD

VAPOR RETARDER(if required)

METAL LATHE

FLASHING TAPE

1/2" GYPSUMWALLBOARD

Notes:1. Stud walls must be properly braced for lateral loadsaccording to the requirements of local Building Codes.

aPPlICaTION / INSTallaTIONStud Wall Construction - Thermasheath-3 applied to the exterior or interior face of studs, to cover all studs, sills, plates and headerconstructions,providesa layerofcontinuous insulation(ci)overdetailsnot normally covered by insulation products. Itmay be secured to theframing or structural sheathing with bugle-head screws, galvanizedroofingnailsorcommonnailsdriventhroughcapwashers.Quality-gradeconstructionadhesivesmayalsobeusedtosecuretheThermasheath-3oninteriorapplications.Exteriorfacadesmayincludebrick/stoneveneer,exterior siding and stucco. Thermasheath-3 must be covered on theinteriorwithaminimum1/2inchgypsumwallboardinteriorfinishthatismechanically attached.

02Stud Wall Construction (Brick Veneer)Thermasheath-3 Exterior Application A1.00

THERMASHEATH - 3

AIR / WATER RESISTIVEBARRIER (if required)

FLASHING TAPE

BRICK VENEER (Provideweeps as required)

THRU-WALL FLASHING(Metal)

SUBFLOORING &FLOOR FRAMING

BRICK TIES AS REQ.

TREATED WOOD

TERMITE SHIELD

VAPOR RETARDER(if required)

FOUNDATION WALL

1/2" GYPSUMWALLBOARD

Notes:1. Stud walls must be properly braced for lateral loadsaccording to the requirements of local Building Codes.

Cavity Wall Construction (Brick Veneer) - Thermasheath-3 is an excellent cavity insulation product fitting between the masonryblockandfinishedbrickveneerofanyresidentialorcommercialproject.It may be secured to the dry face of the masonry block wall with aquality grade construction adhesive. Thermasheath-3 can be cut to fitbetweenmasonry joint reinforcementsplaced to tie thebrickveneer tothe concrete block back-up and installed horizontally in strips to allow the wall ties toextendbeyond the faceof the insulation leaving theproperairspacesasrequired.

04Cavity Wall Construction (Brick Veneer)Thermasheath-3 Exterior Application A1.00

THERMASHEATH - 3

16" OR 24" WIDTHS AVAILABLETO FIT BETWEEN MASONRYWALL TIES OR IMPALEINSULATION OVER WALLTIE PENTILES

BRICK VENEER (Provideweeps as required)

THRU-WALL FLASHING(Metal)

BRICK LEDGE

CMU WALL

FOUNDATION WALL

FLASHING TAPE

Thermasheath®-3

Re-Siding Construction - Thermasheath-3 may be used in retrofit constructionprovided theexistingsiding issoundandsolidlyattached.It is securedwith galvanized nails of sufficient length to penetrate theold sidings, sheathings below and at least one inch into the existing wall studs. Then, cover theThermasheath-3with a suitable new siding ofaluminum,vinyl,fibercement,woodorwoodfiberbasedproducts.

Vaulted Ceiling Construction - Thermasheath-3 may be applied to the inside face of the roof rafters in vaulted ceilingconstruction to provide a layer of continuous insulation (ci) andincrease the R-value of the roof. Simply nail the Thermasheath-3 to thefaceoftherafter,coverwithaminimum1/2inchgypsumwallboard and finish.

Attics and Crawl Spaces - Thermasheath-3 may be applied to the interior face of stud walls or roof rafters within attics and crawl spaces toprovidea layerofcontinuous insulation (ci). Simplynail theThermasheath-3 to the framingmembers and cover with an approvedignition barrier such as 3/8 inch gypsum wallboard or 1/4 inch woodstructural panel, particle board or hardboard.

Concrete Foundations - Thermasheath-3 may be installed horizontally under foundations and vertically inside of the footings. Aseparate vapor retarder sheet should be installed directly against thecrushed stone base and well tamped backfill or undisturbed earth. Then simplylayintheinsulationwithtightlybuttedjoints.Whilenotrequired,tapingthejointsisacceptableusingRmaxR-SEAL3000,RmaxR-SEALConstructionTape,orequivalent.

Roofing Construction-Thermasheath-3islaidoverasuitableroofdeck such as tongue-and-groove timber, plywood or metal deck andcoveredwithasuitablelayerofplywood,waferboardorOSB.Asphaltorwood shingles, concrete or clay tiles or a standing seam metal roof may beinstalledovertheinsulatedroofdeckaccordingtotheroofingsysteminstructions. NOTE: It may not be necessary to cover the insulationwith a nailable surface when used under a standing seam metal roof assembly, consult manufacturer for details.

10Asphalt Shingle Roof ConstructionThermasheath-3 Exterior Application A1.00

UNDERLAYMENT

ASPHALT SHINGLEROOFING SYSTEM

NAILABLE SURFACE

THERMASHEATH - 3

VAPOR RETARDER(if required)

STRUCTURALROOF DECK

WOOD RAFTER ORTRUSS

FASCIA

Notes:1. Consult shingle manufacturer for above deckroofing ventilation requirements.

lImITaTIONSThermasheath-3 is not recommended, nor warranted, for use as a commercial roof insulation directly under membrane systems. Consult RmaxSalesforsuitablecommercialroofinsulationproducts.

Thermasheath-3isnotastructuralpanel.Itmustnotbeusedasanailingbase for any other building products. Furthermore, stud walls insulated with Thermasheath-3 must be properly braced for lateral loads according totherequirementsoflocalBuildingCodes.

WaRNINGDO NOT leave Thermasheath-3 exposed. Polyiso foam is an organicmaterial which will burn when exposed to an ignition source of sufficient heat and intensity and may contribute to flames spreading.

InstallationsutilizingThermasheath-3mustbefullyprotectedontheinteriorsideofthebuildingbyathermalbarriersuchasaminimumof1/2inchgypsumwallboard.Masonryorconcretethatisaminimumofoneinchthick,plywoodthatisaminimumof1/2inchthickandwoodthatisaminimum of one inch nominal thickness may also be recognized as suitable thermal barriers.ConsultyourlocalBuildingOfficialforspecificgoverningcodesandrequirements.

The interior and/or exterior of the building should be protected with asuitablevaporretarderand/orawaterresistivebarrier,ifrequired,basedonlocalBuildingCodesandclimatezone.

WaRRaNTYSeeRmax“SalesPolicy”forwarrantyconditions.Rmaxdoesnotassumeany responsibility or liability for the performance of any products other than those manufactured by Rmax. NOTE: All Rmax products must be tarped, placed on skids and kept dry before and throughout construction.

07Stud Wall & Vaulted Ceiling ConstructionThermasheath-3 Interior Application A1.00

ROOF JOIST / RAFTER

STUD WALL

1/2" GYPSUMWALLBOARD

THERMASHEATH - 3

Notes:1. Refer to local building codesfor requirements on proper ventilation2. Stud walls must be properly braced forlateral loads according to the requirements oflocal Building Codes.

VAPOR RETARDER(if required)

EXTERIOR WOODSHEATHING

03Re-Siding ConstructionThermasheath-3 Exterior Application A1.00

EXISTING SHEATHINGAND SIDING SEENOTE #1

AIR / WATER RESISTIVEBARRIER (if required)

EXTERIOR SIDING

FLASHING TAPE

METAL FLASHING

TREATED WOOD

FOUNDATION WALL

SUBFLOORING &FLOOR FRAMING

VAPOR RETARDER(if required)

FOUNDATION

THERMASHEATH - 3

Notes:1. Existing siding must be inspected and re-nailed to providefor solid back-up to attach new sheathing and sidingmaterials. Deteriorated or rotted areas of existing sidingmust be removed and replaced to restore original thickness.2. Stud walls must be properly braced for lateral loadsaccording to the requirements of local Building Codes.

TERMITE SHIELD

1/2" GYPSUMWALLBOARD

AddiTiONAl THERMAl R-VAluEs“R” means resistance to heat flow. The higher the R-value, thegreaterthe insulatingpower.AccordingtotheASHRAEHandbookofFundamentals,thereflectivefoilfacingofThermasheath-3contributesadditional R-value to the overall assembly when installed against adeadairspace.Forexample,ASHRAEassignsa2.77R-valuetoa3/4inchdead-airspaceagainstareflectivefoilinatypicalwallassembly.ThisvalueisinadditiontotheR-valueofthepolyisofoam-seeSytemR-Valuebelow.

NominalThickness

Thermal R-Value1

SystemR-Value Pcs/Bdl

Inches °F•ft2•hr/Btu °F•ft2•hr/Btu0.50 3.2 5.97 960.75 5.0 7.77 601.00 6.0 8.77 481.25 7.8 10.57 381.50 9.6 12.37 321.55 10.0 12.77 301.75 11.4 14.17 272.00 13.1 15.87 242.25 14.9 17.67 212.30 15.3 18.07 202.50 16.7 19.47 192.75 18.5 21.27 173.00 20.3 23.07 163.25 22.1 24.87 143.50 23.9 26.67 133.75 25.7 28.47 124.00 27.4 30.17 124.25 29.2 31.97 114.50 31.0 33.77 10

1ThermalvaluesaredeterminedbyusingASTMC518testmethodat75°FmeantemperatureonmaterialconditionedaccordingtoPIMATechnicalBulletinNo.101.

Thermasheath-3isshippedinbundlesthatareapproximately48inchhighandwrappedinplasticforeasyhandling.Visitwww.rmax.com for a complete list of thicknesses and packaging information.

Thermasheath-3

Doing one thing well in so many ways...RmaxisaU.S.ownedcompany that only manufactures polyiso insulation. Thermasheath-3 ismanufacturedintheU.S.and is offered through anextensivedistributionnetwork.Itisavailableinstandard four foot wide panels, with standard panel lengths of eight or nine feet. Customlengthsareavailablefor special orders. Contact RmaxSalesatyourregionalCustomerServiceCenterforproductavailability,pricing information, and your nearest distribution center.

Corporate & TechnicalRmaxOperating,LLC13524WelchRoadDallas, Texas 75244-5291Phone:(972) 387-4500Fax:(972) 387-4673Email:rmax@rmax.comWeb:www.rmax.com

Customer Service &Plant locationsCentral Region Dallas, Texas(800) 527-0890 Ext. 102Eastern RegionGreer,SouthCarolina (800) 845-4455 Ext. 156Western Region Fernley,Nevada (800) 762-9462 Ext. 156

Thermasheath®-3

2015-08

For warranties, limitations and conditions refer to Rmax Sales Policy and applicable warranties. All documents are located at www.rmax.com. For technical and sales support, email rmax@rmax.com or call (800) 527-0890.

Proudly Made and Engineered in the U.S.A.

Rmax Sales Offices and Plant Locations

E-mail us at rmax@rmax.com or visit our website www.rmax.com

Central:13524 Welch RoadDallas, Texas 75244

Phone: 972-387-4500Fax: 972-387-4673Toll Free: 1-800-527-0890

East:1649 South Batesville RoadGreer, South Carolina 29650

Phone: 864-297-1382Fax: 864-234-7548Toll Free: 1-800-845-4455

West:210 Lyon DriveFernley, Nevada 89408

Phone: 775-575-4849 Fax: 775-575-5035 Toll Free: 1-800-762-9462

Improving Your Design.

top related