VARIANT™ II Hemoglobin Testing System
H e m o g l o b i n T e s T i n g Bio-Rad Laboratories H e m o g l o b i n T e s T i n g
For further information, please contact the Bio-Rad office nearest you or visit our website at www.bio-rad.com/diagnostics
© 2011 Bio-Rad Laboratories, Inc. Printed in USA 05/11 DG11-0353 A-241
Clinical Diagnostics Group
Website www.bio-rad.com/diagnostics U.S. 1-800-2BIO-RAD Australia 61-2-9914-2800 Austria 43-1-877-8901 Belgium 32-9-385-5511 Brazil 5521-3237-9400 Canada 1-514-334-4372 China 86-21-64260808 Czech Republic 420-241-430-532 Denmark +45-4452-1000 Finland 358-9-804-22-00 France 33-1-47-95-60-00 Germany +49-(0)89-318-840 Greece 30-210-7774396 Hong Kong 852-2789-3300 Hungary +36-1-459-6100 India 1-800-180-1224 Israel 972-3-9636050 Italy +39-02-216091 Japan 81-3-6361-7070 Korea 82-2-3473-4460 Mexico +52 (55) 5488-7670 The Netherlands +31-318-540666 New Zealand 64-9-415-2280 Norway 47-23-38-41-30 Poland 48-22-3319999 Portugal 351-21-472-7700 Russia 7-495-721-14-04 Singapore 65-6415-3170 South Africa 27-11-442-85-08 Spain 34-91-590-5200 Sweden 46-8-555-127-00 Switzerland 41-61-717-95-55 Thailand 662-651-8311 United Kingdom +44-(0)20-8328-2000
Printed on recycled paper with soy-based inks
VARIANT™ II Hemoglobin Testing System For HbA1c
Unparalleled Support
Bio-Rad’s world class service and support team is backed by our decades-long leadership
in the fi eld of HbA1c testing. The VARIANT™ II System represents our continued commitment
to helping you be the difference for the patients who count on you.
Uncompromising Performance
VARIANT™ II System combines superior HbA1c
results, exceptional ease of use and powerful data
management in one powerful automated solution
offering HbA1c, β-thalassemia and dual assays.
Ordering InformationCatalog No. Description
270-2000 VARIANT™ II Hemoglobin Testing System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 unit
270-2101NU VARIANT™ II Hemoglobin A1c Program Reorder Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 tests
740 Lyphochek® Diabetes Control, Bilevel (3 each of 2 levels) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 x 0.5 mL
120 Lyphochek® Hemoglobin A1c Linearity Set, (1 each of 4 levels) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 x 0.5 mL
BC80 EQAS™ Hemoglobin Program (3 analytes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 x 0.5 mL
196-2052 Hemoglobin Capillary Collection System (HCCS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 testsHbA1C reportable in patient sample with HbD trait
Superior HbA1c Accuracy• A1C accuracy in the presence of hemoglobins D, E, S or C
• A1C accuracy in the presence of carbamylated hemoglobin (CHb) and labile A1c (LA1c )
• Anchored to the IFCC Reference Method
• NGSP certifi ed and traceable to the Diabetes Control and Complications Trial (DCCT)
Patient DataSample ID: ADPatient ID:Name:Physician:Sex:DOB:
Comments:
Analysis DataAnalysis Performed: 06/21/2010 13:44:09Injection Number: 205Run Number: 24Rack ID:Tube Number: 3Report Generated: 04/07/2011 18:07:54Operator ID:
Peak Name NGSP % Area % Retention Time (min) Peak AreaA1a — 0.3 0.11 7427A1b — 1.8 0.30 52834F — 1.0 0.58 28918LA1c — 1.2 0.77 32890A1c 7.2* — 0.96 78247P3 — 1.8 1.53 82416P4 — 1.1 1.61 31547A0 — 47.1 1.75 1345160E,D — 43.0 1.89 1227588
*Values outside of expected range Total Area: 2,857,028
HbA1c (NGSP) = 7.2*%
Bio-Rad CDM SystemCDM 5.1 VII Instrument
Patient ReportV2_A1c_NU
20.0
17.5
15.0
12.5
10.0
7.5
5.0
2.5
0.00.0 0.5 1.0 1.5 2.0 2.5 3.0
0.11 0.
30
0.58
0.77
0.96
Time (min.)
%A
1c
1.53 1.
611.
751.
89
A1c
E,D — 43.0 1.89
quality results
Now with both IFCC (mmol/mol) and NGSP (%) HbA1c Values
HbA1C reportable in patient sample with HbE trait
HbA1C reportable in patient sample with CHb and LA1c(CHb is identified as the unknown peak between A1C and LA1c )
Analysis Performed: 06/21/2010 13:44:09Injection Number:
Report Generated:
Retention Time (min) 0.11 0.30 0.58 0.77 0.96 1.53 1.61 1.75
2.5
1.89
Patient DataSample ID: AEPatient ID:Name:Physician:Sex:DOB:
Comments:
Analysis DataAnalysis Performed: 06/21/2010 13:51:23Injection Number: 207Run Number: 24Rack ID: Tube Number: 5Report Generated: 04/08/2011 12:22:29Operator ID: YG-IFCC_DAY1
20.0
17.5
15.0
12.5
0.0
7.5
5.0
2.5
0.00.0 0.5 1.0 1.5 2.0 2.5 3.0
0.30
0.20
0.11
0.55
0.73
0.84
A1c
0.96
1.53
1.63
1.75
1.85
Time (min.)
%A
1c
Bio-Rad CDM SystemCDM 5.1 VII Instrument
Patient ReportV2_A1c_NU
Unknown
A1a
A1b
F
LA1c
Unknown
A1c
P3
P4
A0
E,D
—
—
—
—
—
—
37
—
—
—
—
—
—
—
—
—
—
5.6
—
—
—
—
0.3
0.7
0.9
0.6
0.3
0.8
—
2.5
2.7
53.4
35.6
0.11
0.20
0.30
0.55
0.73
0.84
0.96
1.53
1.63
1.75
1.85
6852
17722
23288
17159
7405
22534
62642
66287
70902
1428051
950966
HbA1c (IFCC) = 37 mmol/mol Total Area: 2,673,808
PeakName
IFCCmmol/mol
NGSP%
Area%
Retention Tim (min)
PeakArea
E,D — — 35.6 1.85 950966
LA1c
Unknown
—
—
—
—
0.3
0.8
0.73
0.84
7405
22534
DEAD ZONE(Grey area)
Bio-Rad Laboratories H e m o g l o b i n T e s T i n g
Your patients count on you. You can count on the VARIANT™ II System.
Exceptional Ease of Use• Fullyautomatedoperationsavestimeandlabor
• Built-inqualitycontrolmanagementsimplifiesquality
assurance compliance
• Reagentssuppliedinconvenientkitformat
• Readilyviewablereagentlevelsintransparentbufferbottles
• Primarytubesamplingwithcappiercingeliminates
manual sample handling
• Positivesampletrackingeliminatessamplemisidentification
• STATcapability
• Batchsamplingandcontinuousfeedingofferflexibilityinworkflow
• Easy-to-useonlinetoolsforQC,instrumentsupport,
remote education and communication services
• HemoglobinCapillaryCollectionSystem(HCCS)allowsremote
fingerstick sample collection to support outreach programs
VARIANT™ II Hemoglobin Testing System
Quality patient care is at the heart of what you do. And VARIANT™ II System
enables you to be the difference for the patients who count on you most—
delivering the best chemistry on the market for exceptionally accurate results.
The VARIANT™ IIHemoglobinTestingSystemisflexible,efficientanduses
gold-standard,highperformanceliquidchromatography(HPLC)todeliver
exceptionally precise HbA1c values in the presence of hemoglobin variants
and other interfering substances.
SuperiorHbA1c Accuracy
ExceptionalEase of Use
PowerfulData Management
Every patient deserves quality results. You deserve ease of use.
Powerful Data Management• Resultsandchromatogramscaptured
and archived by Bio-Rad’s Clinical Data
Management™ (CDM) software
• CDM™ interfaces with your laboratory information
system for optimal data management
• Advanceddiagnostics,useralertsandprompts
reduce costs and training time
DEAD ZONE(Grey area)
VARIANT™ II Hemoglobin Testing System
H e m o g l o b i n T e s T i n g Bio-Rad Laboratories H e m o g l o b i n T e s T i n g
For further information, please contact the Bio-Rad office nearest you or visit our website at www.bio-rad.com/diagnostics
© 2011 Bio-Rad Laboratories, Inc. Printed in USA 05/11 DG11-0353 A-241
Clinical Diagnostics Group
Website www.bio-rad.com/diagnostics U.S. 1-800-2BIO-RAD Australia 61-2-9914-2800 Austria 43-1-877-8901 Belgium 32-9-385-5511 Brazil 5521-3237-9400 Canada 1-514-334-4372 China 86-21-64260808 Czech Republic 420-241-430-532 Denmark +45-4452-1000 Finland 358-9-804-22-00 France 33-1-47-95-60-00 Germany +49-(0)89-318-840 Greece 30-210-7774396 Hong Kong 852-2789-3300 Hungary +36-1-459-6100 India 1-800-180-1224 Israel 972-3-9636050 Italy +39-02-216091 Japan 81-3-6361-7070 Korea 82-2-3473-4460 Mexico +52 (55) 5488-7670 The Netherlands +31-318-540666 New Zealand 64-9-415-2280 Norway 47-23-38-41-30 Poland 48-22-3319999 Portugal 351-21-472-7700 Russia 7-495-721-14-04 Singapore 65-6415-3170 South Africa 27-11-442-85-08 Spain 34-91-590-5200 Sweden 46-8-555-127-00 Switzerland 41-61-717-95-55 Thailand 662-651-8311 United Kingdom +44-(0)20-8328-2000
Printed on recycled paper with soy-based inks
VARIANT™ II Hemoglobin Testing System For HbA1c
Unparalleled Support
Bio-Rad’s world class service and support team is backed by our decades-long leadership
in the fi eld of HbA1c testing. The VARIANT™ II System represents our continued commitment
to helping you be the difference for the patients who count on you.
Uncompromising Performance
VARIANT™ II System combines superior HbA1c
results, exceptional ease of use and powerful data
management in one powerful automated solution
offering HbA1c, β-thalassemia and dual assays.
Ordering InformationCatalog No. Description
270-2000 VARIANT™ II Hemoglobin Testing System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 unit
270-2101NU VARIANT™ II Hemoglobin A1c Program Reorder Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 tests
740 Lyphochek® Diabetes Control, Bilevel (3 each of 2 levels) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 x 0.5 mL
120 Lyphochek® Hemoglobin A1c Linearity Set, (1 each of 4 levels) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 x 0.5 mL
BC80 EQAS™ Hemoglobin Program (3 analytes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 x 0.5 mL
196-2052 Hemoglobin Capillary Collection System (HCCS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 testsHbA1C reportable in patient sample with HbD trait
Superior HbA1c Accuracy• A1C accuracy in the presence of hemoglobins D, E, S or C
• A1C accuracy in the presence of carbamylated hemoglobin (CHb) and labile A1c (LA1c )
• Anchored to the IFCC Reference Method
• NGSP certifi ed and traceable to the Diabetes Control and Complications Trial (DCCT)
Patient DataSample ID: ADPatient ID:Name:Physician:Sex:DOB:
Comments:
Analysis DataAnalysis Performed: 06/21/2010 13:44:09Injection Number: 205Run Number: 24Rack ID:Tube Number: 3Report Generated: 04/07/2011 18:07:54Operator ID:
Peak Name NGSP % Area % Retention Time (min) Peak AreaA1a — 0.3 0.11 7427A1b — 1.8 0.30 52834F — 1.0 0.58 28918LA1c — 1.2 0.77 32890A1c 7.2* — 0.96 78247P3 — 1.8 1.53 82416P4 — 1.1 1.61 31547A0 — 47.1 1.75 1345160E,D — 43.0 1.89 1227588
*Values outside of expected range Total Area: 2,857,028
HbA1c (NGSP) = 7.2*%
Bio-Rad CDM SystemCDM 5.1 VII Instrument
Patient ReportV2_A1c_NU
20.0
17.5
15.0
12.5
10.0
7.5
5.0
2.5
0.00.0 0.5 1.0 1.5 2.0 2.5 3.0
0.11 0.
30
0.58
0.77
0.96
Time (min.)
%A
1c
1.53 1.
611.
751.
89
A1c
E,D — 43.0 1.89
quality results
Now with both IFCC (mmol/mol) and NGSP (%) HbA1c Values
HbA1C reportable in patient sample with HbE trait
HbA1C reportable in patient sample with CHb and LA1c(CHb is identified as the unknown peak between A1C and LA1c )
Analysis Performed: 06/21/2010 13:44:09Injection Number:
Report Generated:
Retention Time (min) 0.11 0.30 0.58 0.77 0.96 1.53 1.61 1.75
2.5
1.89
Patient DataSample ID: AEPatient ID:Name:Physician:Sex:DOB:
Comments:
Analysis DataAnalysis Performed: 06/21/2010 13:51:23Injection Number: 207Run Number: 24Rack ID: Tube Number: 5Report Generated: 04/08/2011 12:22:29Operator ID: YG-IFCC_DAY1
20.0
17.5
15.0
12.5
0.0
7.5
5.0
2.5
0.00.0 0.5 1.0 1.5 2.0 2.5 3.0
0.30
0.20
0.11
0.55
0.73
0.84
A1c
0.96
1.53
1.63
1.75
1.85
Time (min.)
%A
1c
Bio-Rad CDM SystemCDM 5.1 VII Instrument
Patient ReportV2_A1c_NU
Unknown
A1a
A1b
F
LA1c
Unknown
A1c
P3
P4
A0
E,D
—
—
—
—
—
—
37
—
—
—
—
—
—
—
—
—
—
5.6
—
—
—
—
0.3
0.7
0.9
0.6
0.3
0.8
—
2.5
2.7
53.4
35.6
0.11
0.20
0.30
0.55
0.73
0.84
0.96
1.53
1.63
1.75
1.85
6852
17722
23288
17159
7405
22534
62642
66287
70902
1428051
950966
HbA1c (IFCC) = 37 mmol/mol Total Area: 2,673,808
PeakName
IFCCmmol/mol
NGSP%
Area%
Retention Tim (min)
PeakArea
E,D — — 35.6 1.85 950966
LA1c
Unknown
—
—
—
—
0.3
0.8
0.73
0.84
7405
22534
DEAD ZONE(Grey area)
Bio-Rad Laboratories H e m o g l o b i n T e s T i n g
Your patients count on you. You can count on the VARIANT™ II System.
Exceptional Ease of Use• Fullyautomatedoperationsavestimeandlabor
• Built-inqualitycontrolmanagementsimplifiesquality
assurance compliance
• Reagentssuppliedinconvenientkitformat
• Readilyviewablereagentlevelsintransparentbufferbottles
• Primarytubesamplingwithcappiercingeliminates
manual sample handling
• Positivesampletrackingeliminatessamplemisidentification
• STATcapability
• Batchsamplingandcontinuousfeedingofferflexibilityinworkflow
• Easy-to-useonlinetoolsforQC,instrumentsupport,
remote education and communication services
• HemoglobinCapillaryCollectionSystem(HCCS)allowsremote
fingerstick sample collection to support outreach programs
VARIANT™ II Hemoglobin Testing System
Quality patient care is at the heart of what you do. And VARIANT™ II System
enables you to be the difference for the patients who count on you most—
delivering the best chemistry on the market for exceptionally accurate results.
The VARIANT™ IIHemoglobinTestingSystemisflexible,efficientanduses
gold-standard,highperformanceliquidchromatography(HPLC)todeliver
exceptionally precise HbA1c values in the presence of hemoglobin variants
and other interfering substances.
SuperiorHbA1c Accuracy
ExceptionalEase of Use
PowerfulData Management
Every patient deserves quality results. You deserve ease of use.
Powerful Data Management• Resultsandchromatogramscaptured
and archived by Bio-Rad’s Clinical Data
Management™ (CDM) software
• CDM™ interfaces with your laboratory information
system for optimal data management
• Advanceddiagnostics,useralertsandprompts
reduce costs and training time
DEAD ZONE(Grey area)
VARIANT™ II Hemoglobin Testing System
H e m o g l o b i n T e s T i n g Bio-Rad Laboratories H e m o g l o b i n T e s T i n g
For further information, please contact the Bio-Rad office nearest you or visit our website at www.bio-rad.com/diagnostics
© 2011 Bio-Rad Laboratories, Inc. Printed in USA 05/11 DG11-0353 A-241
Clinical Diagnostics Group
Website www.bio-rad.com/diagnostics U.S. 1-800-2BIO-RAD Australia 61-2-9914-2800 Austria 43-1-877-8901 Belgium 32-9-385-5511 Brazil 5521-3237-9400 Canada 1-514-334-4372 China 86-21-64260808 Czech Republic 420-241-430-532 Denmark +45-4452-1000 Finland 358-9-804-22-00 France 33-1-47-95-60-00 Germany +49-(0)89-318-840 Greece 30-210-7774396 Hong Kong 852-2789-3300 Hungary +36-1-459-6100 India 1-800-180-1224 Israel 972-3-9636050 Italy +39-02-216091 Japan 81-3-6361-7070 Korea 82-2-3473-4460 Mexico +52 (55) 5488-7670 The Netherlands +31-318-540666 New Zealand 64-9-415-2280 Norway 47-23-38-41-30 Poland 48-22-3319999 Portugal 351-21-472-7700 Russia 7-495-721-14-04 Singapore 65-6415-3170 South Africa 27-11-442-85-08 Spain 34-91-590-5200 Sweden 46-8-555-127-00 Switzerland 41-61-717-95-55 Thailand 662-651-8311 United Kingdom +44-(0)20-8328-2000
Printed on recycled paper with soy-based inks
VARIANT™ II Hemoglobin Testing System For HbA1c
Unparalleled Support
Bio-Rad’s world class service and support team is backed by our decades-long leadership
in the fi eld of HbA1c testing. The VARIANT™ II System represents our continued commitment
to helping you be the difference for the patients who count on you.
Uncompromising Performance
VARIANT™ II System combines superior HbA1c
results, exceptional ease of use and powerful data
management in one powerful automated solution
offering HbA1c, β-thalassemia and dual assays.
Ordering InformationCatalog No. Description
270-2000 VARIANT™ II Hemoglobin Testing System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 unit
270-2101NU VARIANT™ II Hemoglobin A1c Program Reorder Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 tests
740 Lyphochek® Diabetes Control, Bilevel (3 each of 2 levels) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 x 0.5 mL
120 Lyphochek® Hemoglobin A1c Linearity Set, (1 each of 4 levels) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 x 0.5 mL
BC80 EQAS™ Hemoglobin Program (3 analytes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 x 0.5 mL
196-2052 Hemoglobin Capillary Collection System (HCCS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 testsHbA1C reportable in patient sample with HbD trait
Superior HbA1c Accuracy• A1C accuracy in the presence of hemoglobins D, E, S or C
• A1C accuracy in the presence of carbamylated hemoglobin (CHb) and labile A1c (LA1c )
• Anchored to the IFCC Reference Method
• NGSP certifi ed and traceable to the Diabetes Control and Complications Trial (DCCT)
Patient DataSample ID: ADPatient ID:Name:Physician:Sex:DOB:
Comments:
Analysis DataAnalysis Performed: 06/21/2010 13:44:09Injection Number: 205Run Number: 24Rack ID:Tube Number: 3Report Generated: 04/07/2011 18:07:54Operator ID:
Peak Name NGSP % Area % Retention Time (min) Peak AreaA1a — 0.3 0.11 7427A1b — 1.8 0.30 52834F — 1.0 0.58 28918LA1c — 1.2 0.77 32890A1c 7.2* — 0.96 78247P3 — 1.8 1.53 82416P4 — 1.1 1.61 31547A0 — 47.1 1.75 1345160E,D — 43.0 1.89 1227588
*Values outside of expected range Total Area: 2,857,028
HbA1c (NGSP) = 7.2*%
Bio-Rad CDM SystemCDM 5.1 VII Instrument
Patient ReportV2_A1c_NU
20.0
17.5
15.0
12.5
10.0
7.5
5.0
2.5
0.00.0 0.5 1.0 1.5 2.0 2.5 3.0
0.11 0.
30
0.58
0.77
0.96
Time (min.)
%A
1c
1.53 1.
611.
751.
89
A1c
E,D — 43.0 1.89
quality results
Now with both IFCC (mmol/mol) and NGSP (%) HbA1c Values
HbA1C reportable in patient sample with HbE trait
HbA1C reportable in patient sample with CHb and LA1c(CHb is identified as the unknown peak between A1C and LA1c )
Analysis Performed: 06/21/2010 13:44:09Injection Number:
Report Generated:
Retention Time (min) 0.11 0.30 0.58 0.77 0.96 1.53 1.61 1.75
2.5
1.89
Patient DataSample ID: AEPatient ID:Name:Physician:Sex:DOB:
Comments:
Analysis DataAnalysis Performed: 06/21/2010 13:51:23Injection Number: 207Run Number: 24Rack ID: Tube Number: 5Report Generated: 04/08/2011 12:22:29Operator ID: YG-IFCC_DAY1
20.0
17.5
15.0
12.5
0.0
7.5
5.0
2.5
0.00.0 0.5 1.0 1.5 2.0 2.5 3.0
0.30
0.20
0.11
0.55
0.73
0.84
A1c
0.96
1.53
1.63
1.75
1.85
Time (min.)
%A
1c
Bio-Rad CDM SystemCDM 5.1 VII Instrument
Patient ReportV2_A1c_NU
Unknown
A1a
A1b
F
LA1c
Unknown
A1c
P3
P4
A0
E,D
—
—
—
—
—
—
37
—
—
—
—
—
—
—
—
—
—
5.6
—
—
—
—
0.3
0.7
0.9
0.6
0.3
0.8
—
2.5
2.7
53.4
35.6
0.11
0.20
0.30
0.55
0.73
0.84
0.96
1.53
1.63
1.75
1.85
6852
17722
23288
17159
7405
22534
62642
66287
70902
1428051
950966
HbA1c (IFCC) = 37 mmol/mol Total Area: 2,673,808
PeakName
IFCCmmol/mol
NGSP%
Area%
Retention Tim (min)
PeakArea
E,D — — 35.6 1.85 950966
LA1c
Unknown
—
—
—
—
0.3
0.8
0.73
0.84
7405
22534
DEAD ZONE(Grey area)
top related