waste incineration plants
Post on 04-Feb-2016
100 Views
Preview:
DESCRIPTION
TRANSCRIPT
Waste incineration plants
E.ON Energy from wasteEEW Hannover GmbH
Waste incineration plants in Germanyand in the Netherlands and Luxenburg
Facts about the waste incineration plants
• 230.000 tons per year
• Only household waste and household similar industrial waste
• No dangerous waste
• You get energy for 40.000 households
The principle
1 delivery2 bunker3 (pusher) grade4 slag remover5 cinder bunker6 ammonia water
7 boiler 8 turbine 9 generator10 condenser11 transformer12 spray absorber
13 absorber14 fabric filter15 induced draft fan16 emission measurement17 chimney
Delivery and bunker
• The waste is offloaded from trucks
• The waste is in the bunker
• A cran transports the waste into the boiler
Standpoint
Boiler and grade
• In the boiler the waste is spreaded by grades
• The fire temperature must be everytime over 870°C
Slag remover and cinder bunker
• The residue of the burned waste (slag) is transferred into the slag remover
• Now the slag is cooled down• The cold slag is brought into the cinder bunker• The slag will be transported to another
company• Iron, non ferric metals and not burned material
is taken out• The neutral slag is used for street building
Standpoint
But the smoke would damage the
nature, wouldn‘t it ?!?
No, because there is a cleaning principle!
First step:
Neutralisation of nitrogen oxides by spraying
25% ammonia water.
NH OH + NOx
are getting to
H O + N
4
ammonia water nitrogen oxides
2 2
water atmospheric nitrogen
Second step (spray absorber):
By atomisation of quick lime follows various reactions:
Ca(OH)2 Ca(OH)2 Ca(OH)2
+ + +
SO2 2 HCl 2 HF
H2O + CaSO3 2 H2O + CaCl2 2 H2O + CaF2
quick lime
sulphur oxid hydrochloric acid hydrofluoric acid
water calcium sulfite calcium chloride calcium fluoridwater water
Third step (absorber):Addition to spray absorber:
Gaseous heavy metals and dioxines were bound on carbon.
For reaching that, lime and activated carbon is sprayed against the cours of the smoke:
heavy metal doxines
activated carbon
attaches to attaches to
Forth step (fabric filter):
The solid components in the smoke get drained out by the filter membrane
Regular the solid components get cleaned from the filters by compressed air
The shaken off components are getting into a residue silo and after some time they get into an underground
depot
The clean gas leaves the Waste incineration plants threw the chimney
The induced draft fan supports the escape of the clean gas
Emission measurement
The leaving
Water circulation and steam circuit
How to get energy by burning waste…
… see where it is
•Inside the boiler are pipes in wich water is flowing
•The water is vaporized because of the heat in the boiler
•The steam rises because of the big pressure
•The steam powers the rator of the turbine•The generator produces electricity from the rator energy
•The transformer plant leads the electricity into
•The condenser cools the water down to 60°C
•The circulation begins again
the electricity grid
The principle
The endMade by Jolanda & Joana
top related