In Technical Collaboration with M/s. RBP Ltd. U. K.
®
WATERGUARD MEMBRANE PVCHigh Polymer Underground Waterproofing Membrane
The House of Construction Chemicals
The House of Construction Chemicals
FAIRMATE
FAIRMATE
QUALITY FOCUS
VALUES
Customer Delight :
is an Indian Multi-national construction chemicals manufacturing
company having offices and operations in various parts of the world. We have our
Corporate office in Baroda, India and our branch offices are spread across
country. FAIRMATE is serving Construction Industry for more than three
decades. Apart from our existing manufacturing facilities in India, Dubai and
Far-East, FAIRMATE has widened its presence to few more countries like Nepal,
Pakistan, Sri Lanka, South Korea, Turkey, Lebanon and Qatar etc.
manufactures complete range of construction chemicals and is also
providing total cost-effective solutions and World Class Services to Speciality
Construction Chemical Industry by using our expertise and strategic alliances
with leading partners. We have a primary technical collaboration with M/s Resin
Building Products Ltd., UK and M/s Morton Chemicals, USA. Our continuous
research and efforts in developing new products have resulted in introducing
more than 350 products in the Civil Engineering Industry. Our products are
broadly classified as Concrete Admixture, Waterproofing System,
Engineering Grouts, Industrial Flooring System, Surface Treatment,
Concrete Repairs, Pre-packed Concrete and Mortar, Protective Coating,
Sealants, Highway Repairs and Fire Protection systems.
FAIRMATE has set-up its plant and state-of-art R&D centres in various parts of
the globe. Quality has always been an integral part of Management Philosophy.
Ensuring international standard products to our esteemed customers, we have
been accredited by ISO 9001 and ISO (EMS) 14001, which emphasize the
quality system of each and every step of processing and 'zero' defect operations.
We have gone further and have implemented ISO (OHSAS) 18001, which
relates to total operational Health and Safety. To ensure Total Customer
Satisfaction FAIRMATE is now marching towards “SIX SIGMA”.
The values that drive us underscore our commitment to: consistently surpass customer expectations.
FAIRMATE also ensures application of the products through authorized trained
applicators.FAIRMATE caters to a large group of customers ranging from multinational
companies to individual domestic customers. We have a wide network in India as
well as internationally.
< Africa Bangladesh Bhutan Nepal Qatar Singapore Srilanka Thailand U.A.E Vietnam
<<<<<<<<<
BHUBANESWAR FACTORY
BENGALURU FACTORY
Advantages
Products : PVC Waterproofing Membranes cover the requirements of
<
<
<
<
<
<
<
<
<
<
<
<
WATERGUARD MEMBRANE PVC is easy to apply using hot air welding for joints. The joints are
homogeneously welded (PVC to PVC). No sealant or chemicals are required for joints (overlaps)
No adhesives or Primers are required for installation of WATERGUARD MEMBRANE PVC. Self
extinguishing material. (Safe In case of fire)
No Fire requirement for application.
WATERGUARD MEMBRANE PVC is resistant to high temperature fluctuations.
WATERGUARD MEMBRANE PVC remains flexible throughout its life span and could be easily joined to
new materials after installation, in case of extension or any mechanical damage.
Minimum slope is sufficient.
Roofing (covered & exposed roofs)/ Re- roofing
Tunnel Lining
Tanking of Underground structures
Lining of evaporation ponds & artificial lakes
Lining of drinking water tanks & swimming pools
Agricultural purposes & Lining of irrigation canals
Use to WATERGUARD MEMBRANE PVC
SCOP IF WORK FOR UNDERGROUND STRUCTURES
1. Installing ( Horizontal Area )
A.
B.
C.
D.
E.
Blinding concrete surface should be smooth, clean & free from sharp projections, otherwise, a
protection layer (non-woven polyester, min140 gr./m2) must be used to receive PVC membrane.
Apply (PVC 1500 TNL) membranes loose laid for horizontal areas with 50mm overlap by using hot air
welding technique. Horizontal PVC membranes shall be installed with extension of 300mm to enable
the welder to join the horizontal membranes at the corners properly with the followed vertical PVC
membrane.
Apply horizontally protection layer Non-woven polyester, min140gr./m2) with 100mm overlap over
the entire horizontal PVC membrane or as required.
Cover sheets with permanent overlaying construction as soon as possible. This can be by applying a
minimum 50mm thick concrete protection layer.
Lay steel reinforcement and concrete as specified
2. Installing ( Vertical area )
A.
B.
Vertical surfaces should be smooth, clean & free from sharp projections, otherwise a protection layer
(non woven polyester, min140 gr./m²) must be used to receive PVC membrane.
Apply (PVC 1500 TNL) membrane vertically by mechanical fixing using PVC coated metal strips (50mm
width) fixed horizontally to the walls by fasteners and receiving PVC membrane by using hot air
welding technique over the strips. PVC rolls should be joined vertically with 50mm overlaps using hot
air welding technique.
Pipes, ducts, cables, etc. where passing through sheets., must be completely watertight using pre-
formed collars fully bonded/sealed to both pipes and sheets. Dressing can be made at site using the
same PVC liner.
C.
<
<
<
<
The most common technique used to join PVC waterproofing sheets.
The sheets should overlap by at least 50 mm.
The Leister Triac hand welder is used for Hot Air welding of
WATERGUARD MEMBRANE PVC.
The hand welder is supplied with a 20mm, 40mm, wide welding nozzles
and 40mm wide leister rubber roller
HOT AIR WELDING
As per the hot air is being applied, the seam must at the same time be rolled
flat to the membrane edge using the pressure roller
WELDING THE SEAM
The House of Construction Chemicals
The House of Construction Chemicals
3. Protection
4. Test Method
Cover external walls of tanking system with at least (10, mm thick)
Protection Boards, provide a temporary support or Insurbond-106
contact adhesive to ensure full contact of boards to tanking system
during back filling operation.
To check welding quality at the overlaps, Visual test, Needle test or
Vacuum test can be used when necessary.
WELDING THE LOWER SEAM EDGE
Before the seams are welded, they are tag-welded every 2-3m, which
ensures uniform seam overlap, welding is then carried out in two passes,
during the first pass the lower seam edge only is welded to prevent the hot air
from escaping during the actual welding pass.
WELDING THE LOWER SEAM EDGE
WELDING THE SEAM
<
<
<
Round off the corner piece.
Fit in corner piece and tag-weld in to corner.
Complete corner weld
Membrane Thickness (mm)
Tensile Strength
Elongation
Thermal Stability
Tear Strength (N)
Thermal Ageing
Slit Pressure Resistance
Thermal Ageing
Roots Resistance
Combustibility
Water Vapor Defusion Resistance
Water Absorption
Compression Strength
Puncture Resistance
Seam Strength
Cold Bend
Resistance to Algea & Rot
Chemical Resistance
DIN 16938
DIN 16938
DIN 16938
DIN 16730
DIN 16938
DIN 16730
DIN 16938
SIA 280/4
SIA 280/7
SIA 280/10
SIA 280/11
DIN 16730
SIA 280/12
SIA 280/13
DIN 16730
SIA 280/15
DIN 16730
DIN 16730
DIN 16738
+10%
>15N/mm2 longitudinal
transversal
>200% longitudinal
transversal
6h/80c <2% longitudinal
transversal
80 N.
7d/80c change of tensile strength &
elongation<±20% folding in cold
at-20c:nocracks
1h /5bar (0.5N/mm2.) Tight
70d/70c mass decrease<2%
change of elongation
No root penetration ingrown roots
must die off
Class V/ smoke class 2
Less than 30,000
8 month storage in water
<±6% folding in cold at-20c,
no cracks
48h/7N/mm² tight
Drop hammer 500g, no leak onfalling
from 500mms
No peeling or sliding of
welded seam
No cracks at-20C.
High Resistance
1.50
>17.00 N/mm²
>16.00 N/mm²
>400
both directions
< 1.0% both directions
> 110N.
< 1% both directions -30C,
no cracks
Passed
Mass decrease<0.5% change in elongation
2% both directions
Passed
Passed
Less than 22,000
Passed
Passed
Passed
Passed
Passed
No cracks at -30C
High Resistance
StandardsStandard
RequirementsResults, 1500 TNL
28/lime milk, change of tensile strength
longitudinal/transversal % change of elongation
<±20% longitudinal/transvarsal %
28/salt water, change of tensile strength
longitudinal/transversal % change of elongation
<±20% longitudinal/transvarsal %
28/sulfurous acid, change of tensile strength
longitudinal/transversal % change of elongation
<±20% longitudinal/transvarsal %
Folding in cold at-20C, no cracks in all cases
Soil Resistance
Resistance to 10% Calcium Hydroxide, 7 days No change
in tensile & elongation <3%
Resistance of 10% sodium chloride, slight color change,
change in tensile strength & elongation <3%
3% sulfuric acid, slight change in colour, change in tensile
strength & elongation <3%
Pass
Pass
PRODUCT DESCRIPTION :WATERGUARD MEMBRANE PVC underground waterproofing 1500 TNL is a calendred high polymer waterproofing membrane, (thickness 1.50mm) not compatible
with bitumen, manufactured to the highest International standards offering high physical properties and long term durability. WATERGUARD MEMBRANE 1500 TNL is
Test
The information given in this data sheet is based on both the current development work and many years of field experience. Whilst every effort is made to ensure that the information is reliable, we cannot accept the responsibility for any work carried out with our materials as we have no control over methods of application, site conditions etc. In view of the continuing research and development being undertaken in our laboratories we advise customers in their own interest to ensure that this data sheet has not been supersede by a more up-to-date publication. All products are sold subjected to our standard conditions of sale which are available on request. Field services, where provided, does not constitute supervisory responsibility. For additional information, please contact our local FAIRMATE representative.
FM/05/10/A
INDIA
For more details visit us at: www.fairmate.com & www.waterproofing4u.com
AFRICA NEPAL OMAN PAKISTAN QATAR SAUDI ARABIA SINGAPORE SRI LANKA VIETNAM
Hamriyah Free Zone, P.O. BOX No. : 42023, Sharjah, UAE.
Tel. : +9716 5261052, Fax : +9716 5261053 Mobile : +971 50 4355048 email : sales@fairmate.ae
DUBAI
BARODA :
AHMEDABAD :
BENGALURU : DELHI :
KOLKATA : MUMBAI :
UDAIPUR : JAIPUR : LUCKNOW :
8/1, "SAI SUDHA", Tel. : (0265) 2358173-74, 2331193, 2331399 Fax : (0265) 2338733 Email : sales@fairmate.net
3, Ramkrupa Appartment, B/h Center Point, Panchvati 1st Lane, Ambawadi, Ahmedabad-380 006. Tel. : (079) 26465219 Tel./Fax : 26465577
Tel. (080) 23639852 Tel./Fax : (080) 23639851 Email : bangalore@fairmate.net Tel./Fax : (011) 27306224/82 Mobile 9810032422 Email :
delhi@fairmate.net Tel. : (033) 24404932 Tel. : (022) 28794045, 28794044 Mobile 9820291610 Email : mumbai@fairmate.net
Mobile 09829699943 Mobile 09829688843 Mobile 9415022470
Arunoday Society, Alkapuri, Baroda-390 007.
Mobile 09850817020 Mobile 09813972551
Mobile 09847169473 Mobile 09719402888 Mobile 09815039539
SANGLI : PANIPAT :
KOCHI : AGRA : JALANDHAR :
top related