1

IntelliFresh Function & Features

Important Safeguards/SymbolsThis appliance is designed for commercial use. Any servicing other than cleaning and preventive mainte-nance should be performed by an authorized Wilbur Curtis service technician. •DONOTimmersetheunitinwateroranyotherliquid •Toreducetheriskoffireorelectricshock,DONOTopenservicepanels.Nouserserviceableparts

inside. •Keephandsandotheritemsawayfromhotsurfacesofunitduringoperation. •Nevercleanwithscouringpowders,bleachorharshchemicals.

Symbols

WARNINGS–Tohelpavoidpersonalinjury

ImportantNotes/Cautions–fromthefactory

SanitationRequirements

Wilbur Curtis Company, inC.ServiceManual–GeminiIntelliFreshSatellite

WarmersThewarmers,willturnonautomaticallywheneveracof-feebrewcycleisstarted.Thetemperatureofthewarmersarecontrolledatthewarmerbuttons on the control panel. TheG3UCMisshownontheleftsideandtheG4touchscreenUCMisontheright.

FOR THE LATEST SPECIFICATIONS AND INFORMATION GO TO WWW.WILBURCURTIS.COM

Model GEM3IF

TheIntelliFreshsystemwillalertyouwhenthecoffeehasexceededthedesiredholdingtime.TheIntellifreshsystemisactivatedbyaconnectorontheSatellitecomingintocontactwithacorrespondingconnectoronthecenterpanel.IntelliFreshisadjustablethroughtheUCMcontrolpanelonthebrewer.

Quality Timer(FactorySetto2hours)Press ¤toselect,press<or>tochoosedesiredsetting.Range20min.to240min.Thetimerisintendedtonotifytheuserwhenthecoffeelosesitsfreshness.Theindicatorlight(LED)onthesatellitewillremainsolidreduntiltheQualityTimerexpires(FactorySetto2hours).AtexpirationtheLEDwillflashandremainflashingatthefactorysettingforanadditional8hours.Theadditional8hoursiscontrolledbytheWarmerAuto-Offsetting.• SettingRange:20–240minutes.Thedefaulttimeis2hours.• TimeExpirationIndicator:LEDflashesafterexpirationofQualityTimerSettingforuptoatotalof12hours.Thedefaulttimeis8hoursafter

expirationoftheQualityTimer.Warmer Auto-Off (factorysetto10Hrs.)Press ¤toselect<or>toadjustfrom1-12hours.ThisfeaturehashigherprioritythantheQualityTimer.Itshutsoffthewarm-ersafterapre-determinedtimefactorysetat10hoursstartingwhentheBrewButtonispushed.TheQualityTimerdoesnotaffect this function.

LG

MED

SM

LG

MED

SM

Ready to brew!

LOW MED HIGH

Error Codes:1. Threelongblinks&oneshortblink=heatererror.2. Threelongblinks&twoshortblinks=sensorerror

WARMERS

2

Illustrated Parts List GEM3IF

2

3

4

5

6

1

7

1011

12

13

16

18

19

8

9

A

20

15

14

17

A

3

DescriptionIndex

Nº Part Nº

* SUGGESTED PARTS TO STOCK

Illustrated Parts List GEM3IF 1

2 3 4 5 6 7 8 91011121314151617181920

WC-5622*WC-2001WC-2005*WC-2025*WC-2010CWC-2006*WC-2102WC-39747WC-2007WC-6417WC-1901AWC-1800*WC-37543* WC-37544*WC-39746WC-37545*WC-3705*WC-38151WC-13426WC-39747

LID, BLACK PLASTIC GEM-3CAP, SHIELD W/VENTWASHER, SHIELD CAP 1/8”GLASS, GAUGE 8”SHIELD, GAUGE GLASS ¾” D. x 8”WASHER, .188ID x .188 THK BOTTOMGAUGE GLASS ASSEMBLY 8”LABEL, SIDE GEM3IF CURTIS LOGOBRACKET, GAUGE GLASS GEM-3GUARD, FAUCET GEM-3SHANK, FAUCET W/SHIELD BASEFAUCET, S’ SERIES NON-LOCKINGKIT, INTELLIFRESH HEATER GEM3IFKIT, LED LIGHT GEM3IFLABEL, FRONT GEM3IF CURTIS LOGOKIT, HYBRID TEMPERATURE CONTROLKIT, FAUCET S’ SERIESLABEL, LOCK/UNLOCK GEM3IF CONNECTOR, FEMALE W/WIRESLABEL, SIDE GEM-3IF CURTIS LOGO

A daily routine of cleaning the GEM3IF Satellite will maintain the appearance of the unit and ensure great tasting coffee. To clean the Satellite components, prepare a mild solution of detergent and warm water.

CAUTION – Do not use cleansers, liquids containing bleach, powders or any other substance containing chlorine. These products promote corrosion and will pit the stainless steel. USE OF THESE PRODUCTS WILL VOID THE WARRANTY.

Cleaning the GEM3IF Satellite

DO NOT immerse the Satellite in water or any other liquid.1. Remove lid from Satellite. Clean the lid at the funnel area with a

spiral brush and detergent solution. 2. Rinse the lid, removing all traces of cleaning solution.3. Clean inside of the Satellite. Remove coffee residue with the deter-

gent solution.4. Thoroughly rinse out the Satellite with clean warm water.5. Unscrew the handle/bonnet assembly and remove it from the dis-

pensing faucet.6. Inspect the silicone seat cup for wear, cracks, or hardening. If okay,

then leave the seat cup attached on the handle/bonnet assembly. Soak then wipe clean. Replace the seat cup if damaged.

7. Remove the gauge glass tube by unscrewing the gauge glass cap.8. Clean the gauge glass tube with a gauge brush soaked with detergent solu-

tion. Soak and wipe the two washers. Rinse with clean water. Dry the parts and assemble them onto the Satellite. Hand tighten the cap.

9. Clean all parts. Thoroughly rinse with clean warm water.10. Dry and assemble the parts. Hand-tighten when the assembling.

CAP

WASHER

GLASS TUBE

WASHERSEATCUP

4

ECN 14861 . 3/8/13@10.8ECN 13883 . 3/1/12@9.5ECN 13791 . 1/27/12@12.4ECN 13695 . 12/21/11@14.6EDR 7787 . 5/26/11@8.1

Electrical SchematicGEM3IF

Printed in U.S.A. 3/2013 . F-3814 . rev D

WILBUR CURTIS CO., INC.6913 Acco St., Montebello, CA 90640-5403 USAPhone: 800/421-6150 Fax: 323-837-2410Technical Support Phone: 800/995-0417 (M-F 5:30A - 4:00P PST) E-Mail: techsupport@wilburcurtis.comWeb Site: www.wilburcurtis.com