young s piece ~ pontesbury · floor (2): 5 0 first floor drawn b y dat e jdc 03/06/201 9 checked b...

Post on 05-Jun-2020

0 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Young s Piece ~ PontesburyPlot 1 ~ For Sale

3 Bedroom Detached Home

HOMES

Illustration only. All details intended as a guide only & may be subject to change.

@picardyhomes@picardyhomespicardy_homespicardy-homes.co.uk

PLOT 13 Bedroom Detached Home

Front - North Elevation Rear - South Elevation

East Elevation

HOMES

picardy-homes.co.uk

Illustration only. All details intended as a guide only & may be subject to change.

@picardyhomes@picardyhomespicardy_homes

West Elevation

Illustration only. All details intended as a guide only & may be subject to change. HOMES

PLOT 13 Bedroom Detached Home

Living Room 6.4m x 3.7m 21’ x 21’1”

Kitchen/Family Dining 6.4m x 3.7m 21’ x 21’1”

Utility 2.1m x 1.5m 6’9” x 4’9”

Master Bedroom 3.7m x 3.4m 12’4” x 11’1”

Ensuite 1 2.1m x 1.5m 6’9” x 4’9”

Bedroom 2 3.7m x 3.5m 11’8” x 9’1”

Bedroom 3 3.7m x 2.7m 11’8” x 9’1”

Family Bathroom 2.7m x 2.5m 8’8” x 8’2”

Drawn by DateJDC 03/06/2019Checked by DateJDC 03/06/2019

Key Plan

Notes

Key Plan

Notes

1:50

L107Drawing Number

Drawing Name

Marketing Plans House Type 1 plot 1

Drawing Scale

Address

Job TitleLieuin Ltd new residential development

Minsterley Road A488, Pontesbury, SY30QH

Job Code

PON001

In addition to the hazard/risks normally associated with the types of work detailed on thisdrawing take note of the above. It is assumed that all works on this drawing will be carried outby a competent contractor working, where appropriate, to an appropriate method statement.

Safety Health and Environmental InformationBox

Construction Risks Maintenance/cleaning Risks Demolition/adaptation Risks

This document and its design content is copyright ©. It shall be read inconjunction with all other associated project information includingmodels, speci�cations, schedules and related consultants documents.Do not scale from documents. All dimensions to be checked on site.Immediately report any discrepancies, errors or omissions on thisdocument to the Originator. If in doubt ASK.

In addition to the hazard/risks normally associated with the types of work detailed on thisdrawing take note of the above. It is assumed that all works on this drawing will be carried outby a competent contractor working, where appropriate, to an appropriate method statement.

Safety Health and Environmental InformationBox

Construction Risks Maintenance/cleaning Risks Demolition/adaptation Risks

This document and its design content is copyright ©. It shall be read inconjunction with all other associated project information includingmodels, speci�cations, schedules and related consultants documents.Do not scale from documents. All dimensions to be checked on site.Immediately report any discrepancies, errors or omissions on thisdocument to the Originator. If in doubt ASK.

aiparchitects ltdThe StudioTy Newydd, Pelham Road, Upton Magna.Shropshire. SY4 4UATel: 01743 709572Mob: 07703 773 872Email: aiparchitects@me.com

RevDateDescription

11

3,742

6,402

6,402

3,742

1,504

2,135

2,7983,484

3,757

3,747

3,5042,778

2,548

3,757

1,519

2,145

1GF-Ground Floor (2)1:50201-First Floor (2)1:50Drawn by DateJDC 03/06/2019Checked by DateJDC 03/06/2019

Key Plan

Notes

Key Plan

Notes

1:50

L107Drawing Number

Drawing Name

Marketing Plans House Type 1 plot 1

Drawing Scale

Address

Job TitleLieuin Ltd new residential development

Minsterley Road A488, Pontesbury, SY30QH

Job Code

PON001

In addition to the hazard/risks normally associated with the types of work detailed on thisdrawing take note of the above. It is assumed that all works on this drawing will be carried outby a competent contractor working, where appropriate, to an appropriate method statement.

Safety Health and Environmental InformationBox

Construction Risks Maintenance/cleaning Risks Demolition/adaptation Risks

This document and its design content is copyright ©. It shall be read inconjunction with all other associated project information includingmodels, speci�cations, schedules and related consultants documents.Do not scale from documents. All dimensions to be checked on site.Immediately report any discrepancies, errors or omissions on thisdocument to the Originator. If in doubt ASK.

In addition to the hazard/risks normally associated with the types of work detailed on thisdrawing take note of the above. It is assumed that all works on this drawing will be carried outby a competent contractor working, where appropriate, to an appropriate method statement.

Safety Health and Environmental InformationBox

Construction Risks Maintenance/cleaning Risks Demolition/adaptation Risks

This document and its design content is copyright ©. It shall be read inconjunction with all other associated project information includingmodels, speci�cations, schedules and related consultants documents.Do not scale from documents. All dimensions to be checked on site.Immediately report any discrepancies, errors or omissions on thisdocument to the Originator. If in doubt ASK.

aiparchitects ltdThe StudioTy Newydd, Pelham Road, Upton Magna.Shropshire. SY4 4UATel: 01743 709572Mob: 07703 773 872Email: aiparchitects@me.com

RevDateDescription

11

3,742

6,402

6,402

3,742

1,504

2,135

2,7983,484

3,757

3,747

3,5042,778

2,548

3,757

1,519

2,145

1GF-Ground Floor (2)1:50201-First Floor (2)1:50

Master Bedroom

Ensuite

Bathroom

Bedroom 3

Living Room

Entrance Hall

Ground Floor First Floor

Kitchen / Family Dining Bedroom 2

Utility

1

HOMES

PLOT 13 Bedroom Detached Home

Young s Piece

picardy-homes.co.uk

Illustration only. All details intended as a guide only & may be subject to change.

@picardyhomes@picardyhomespicardy_homes

1

top related