analysis of the dielectron continuum in au+au @ 200 gev with phenix

24
1 Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX Alberica Toia for the PHENIX Collaboration Physics Motivation Analysis Strategy (765M events) – Cuts • Single electron cuts • Electron pair cuts: remove hit sharing – Spectra: Foreground, Background (mix events), Subtracted Efficiency / Acceptance Cocktail & theory comparison

Upload: hilda

Post on 13-Jan-2016

31 views

Category:

Documents


2 download

DESCRIPTION

Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX. Physics Motivation Analysis Strategy ( 765M events) Cuts Single electron cuts Electron pair cuts: remove hit sharing Spectra: Foreground, Background (mix events), Subtracted Efficiency / Acceptance - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

1

Analysis of the dielectron continuum in Au+Au @ 200

GeVwith PHENIX Alberica Toiafor the PHENIX Collaboration

• Physics Motivation • Analysis Strategy (765M events)

– Cuts• Single electron cuts • Electron pair cuts: remove hit sharing

– Spectra: Foreground, Background (mix events), Subtracted

– Efficiency / Acceptance• Cocktail & theory comparison

Page 2: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

2

Physics Motivation: em probes

space

time

Hard Scattering

AuAu

Exp

ansi

on

Hadronization

Freeze-out

QGPThermaliztion

e- e+

electro-magnetic radiation: , e+e-, +-

rare, emitted “any time”; reach detector unperturbed by strong final state interaction

Page 3: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

3

e+e Pair Continuum at RHIC

Expected sources• Light hadron decays

– Dalitz decays – Direct decays and

• Hard processes– Charm (beauty)

production – Important at high mass &

high pT

– Much larger at RHIC than at the SPS

• Cocktail of known sources– Measure , spectra &

yields– Use known decay

kinematics– Apply detector

acceptance– Fold with expected

resolution

Possible modifications

suppression (enhancement)

Chiral symmetry restoration continuum enhancement modification of vector mesons

thermal radiationcharm modificationexotic bound states

R. Rapp nucl-th/0204003R. Rapp nucl-th/0204003

e-

e+

Page 4: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

4

Electron IdentificationPHENIX optimized for Electron ID• track + • Cherenkov light RICH + • shower EMCAL

Charged particle tracking: DC, PC1, PC2, PC3 and TECExcellent mass resolution (1%)

Pair cuts (to remove hit sharing)

Energy-Momentum

All charged tracks

Background

Net signalReal

RICH cut

PC1

PC3

DC

magnetic field &tracking detectors

e+e

Page 5: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

5

Which belongs to which? Combinatorial background e+ e- eeeeee0 e+ e- 0 e+ e- 0 e+ e- 0 e+ e-PHENIX 2 arm spectrometer acceptance:

dNlike/dm ≠ dNunlike/dm different shape need event mixinglike/unlike differences preserved in event mixing Same

normalization for like and unlike sign pairs

Combinatorial Background

--- Foreground: same evt--- Background: mixed evt BG fits to FG

0.1%

RATIO

Page 6: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

6

• Different independent normalizations used to estimate sys error– Measured like sign yield – Event counting: Nevent / Nmixed events– Poisson assumption: N± = 2√N++N—– Track counting: ‹N±› = ‹N+›‹N-›

• All the normalizations agree within 0.5%

Combinatorial Background

Systematic uncertainty: 0.25%Systematic uncertainty: 0.25% e+ e -

e+ e -

--- Foreground: same evt--- Background: mixed evt

Page 7: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

7

Photon conversion rejection

Mass [GeV/c2]

--- without conversion --- with conversion

air

Support structures

Conversion removed with orientation angle of the pair in the magnetic field

Photon conversion

e+e- at r≠0 have m≠0(artifact of PHENIX tracking)• effect low mass region• have to be removed

r ~ mee

beampipe

Page 8: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

8

Subtracted spectrum

All the pairsCombinatorixSignal

BG normalized to Measured like sign yield

Integral:180,000 above 0:15,000

Green band: systematic uncertainty• Acceptance• Efficiency• Run-by-run

Page 9: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

9

Signal to Background• Very low signal to

background ratio in the interesting region main systematic uncertainty

Yellow band: error on combinatorial background normalization

Green band: other systematics

signal/signal = BG/BG * BG/signal0.25% large!!!

Page 10: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

10

A closer look at resonances

Upsilon???

J/psi

phiAgreement with other analyses

Page 11: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

11

Cocktail comparison

• Data and cocktail absolutely normalized

•Cocktail from hadronic sources•Charm from PYTHIAPredictions are filtered in PHENIX acceptance

•Good agreement in 0 Dalitz•Continuum:hint for enhancement not significant within systematics

•What happens to charm?•Single e pt suppression•angular correlation???

• LARGE SYSTEMATICS!

Page 12: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

12

Data/cocktail

Measurement [10-5 counts/event]

Predictions[10-5 counts/event]

0.15-0.7 GeV/c2 17.8 ± 3.8 ± 1.50 12.3

1.1-2.5 GeV/c2 0.67 ± 0.50 ± 0.11 1.16

Page 13: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

13

Comparison with theory

R.Rapp, Phys.Lett. B 473 (2000)R.Rapp, Phys.Rev.C 63 (2001)R.Rapp, nucl/th/0204003

• Systematic error too large to distinguish predictions• Mainly due to S/B• Need to improve

HBD

• calculations for min bias• QGP thermal radiation included

Page 14: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

14

A Hadron Blind Detector (HBD) for PHENIX

S/B ~ 100x

Irreducible charm background

signal electron

Cherenkov blobs

partner positronneeded for rejection e+

e-

pair opening angle

~ 1 m

• Dalitz rejection via opening angle – Identify electrons in field free region– Veto signal electrons with partner

• HBD concept: – windowless CF4 Cherenkov detector – 50 cm radiator length– CsI reflective photocathode – Triple GEM with pad readout

• Construction/installation 2005/2006

S/B increased by factor 100

Page 15: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

15

Summary & Outlook

• First dielectron continuum measurement at RHIC– Despite of low signal/BG– Thanks to high statistics– Good understanding of background normalization

• Measurement consistent with cocktail predictions within the errors– Improvement of the systematic uncertainty

• HBD upgrade will reduce background great improvement of systematic and statistical uncertainty

“The most beautiful sea hasn't been crossed yet. And the most beautiful words I wanted to tell you I haven't said yet ...“ (Nazim Hikmet)

Page 16: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

16

Backup

Page 17: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

17

Single electron cuts• Event cut:

– zvertex <= 25• Single electron cuts:

– Pt: = 150 MeV – 20 GeV– Ecore >= 150 MeV– Match PC3 & EMC

• PC3 (Phi+z) < 3 sigma• EMC (Phi+z) < 3 sigma

– Dispmax < 5 (ring displacement)– N0min >= 3 tubes– dep >= -2 sigma (overlapping

showers NOT removed)– chi2/npe0 < 10– Quality = 63, 51, 31

Page 18: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

18

Pair cuts

RICH ghosts (like and unlike sign)Post Field Opening Angle < 0.988

--- Foreground: same evt--- Background: mixed evt

like

Cos(PFOA)

DC ghosts (like sign): fabs(dphi) < 0.1 rad fabs(dz) < 1.0 cm

Page 19: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

19

Systematic error

• Systematic error of simulation – Acceptance difference between real/simulation is

less than: 3%.– Single e eID efficiency difference between

real/simulation is less than 8.8%.• Dep < 1%, emcsdphie < 1%, emcsdze < 1%, n0 <

7%, chi2/npe0 < 1%, disp < 5%.

• Systematic error of real data– Stability of acceptance: 5%– Stability of eID efficiency: 5%

• Other correction factor– Embedding efficiency < 10% (Run2 7%).

• Background Normalization

Page 20: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

20

Acceptance filter

Roughly parametrized from data

char

ge/

pT

0

0

z vertex

• Decoupling acceptance – efficiency corrections• Define acceptance filter (from real data)• Correct only for efficiency IN the acceptance• “Correct” theory predictions IN the acceptance• Compare

ACCEPTANCE FILTER

Page 21: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

21

Efficiency2 sets of simulations of dielectron pairs

•White in mass (0-4GeV)•White in pT (0-4GeV)•Vertex(-30,30), rapidity (1unit), phi (0,2)

•Linearly falling mass (0-1GeV)•Linearly falling pT (0-1GeV)•Vertex(-30,30), rapidity (1unit), phi (0,2)

2D efficiency corrections:Mass vs pT

Page 22: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

22

Single e distribution: Poisson

0-10%

20-30%

10-20%

30-40%

Page 23: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

23

Normalization of combinatorial backgroundSame normalization used for like and unlike sign pairs 4 different (independent) normalizations:

• Akiba : Nevent / Nmixed events• Hemmick: N± = 2√N++N—• Zajc: ‹N±› = ‹N+›‹N-›• Drees: 0.5*( (IntegralFG++(0.15-4 GeV) / IntegralBG++(0.15-4 GeV))  + (IntegralFG-- (0.15-4 GeV) / IntegralBG-- (0.15-4 GeV)) )

Normalization factors [10-2]• akiba: 8.74• hemmick: 8.69• zajc: 8.71• drees: 8.70

upper limit: Integral in charm region=0 Normalization factor 8.75

All normalizations agree within 0.5%

All normalizations agree within 0.5%

Page 24: Analysis of the dielectron continuum in Au+Au @ 200 GeV with PHENIX

24

The unfiltered calculations

•black: our standard cocktail•red : hadronic spectrum using the VACUUM rho spectral function•green: hadronic spectrum using the IN-MEDIUM rho spectral function•blue : hadronic spectrum using a rho spectral function with DROPPING MASS•magenta : QGP spectrum using the HTL-improved pQCD rate