    Analysis of Thermal Behavior of High Frequency

    Transformers Using Finite Element MethodHossein Babaie, Hassan Feshki Farahani

    Ashtian Branch, Islamic Azad University, Tehran, Iran.Email: {hbabaei2002, hfeshki}@yahoo.com

    Received August 15th, 2010; revised September 17th, 2010; accepted September 20th, 2010.

    ABSTRACT

    High frequency transformer is used in many applications among the Switch Mode Power Supply (SMPS), high voltagepulse power and etc can be mentioned. Regarding that the core of these transformers is often the ferrite core; their

    functions partly depend on this core characteristic. One of the characteristics of the ferrite core is thermal behaviorthat should be paid attention to because it affects the transformer function and causes heat generation. In this paper, atypical high frequency transformer with ferrite core is designed and simulated in ANSYS software. Temperature risedue to winding current(Joule-heat) is considered as heat generation source for thermal behavior analysis of the trans-former. In this simulation, the temperature rise and heat distribution are studied and the effects of parameters such asflux density, winding loss value, using a fan to cool the winding and core and thermal conductivity are investigated.

    Keywords: High Frequency Transformers, Thermal Behavior, Ferrite Core and Finite Element Analysis

    1. Introduction

    Magnetic components design plays a key role in achiev-ing high efficiency, low volume and reasonable price of

    power electronic equipment. With the advent of higherswitching frequencies and power densities in power elec-tronic circuits, it is important to ensure that magneticcomponents, such as transformers and inductors, operatewithin the limits defined by the thermal specifications ofthe circuit. Temperature rise depends on the power lossesthrough the laws of the heat transfer theory. In order toobtain an accurate value of the maximum temperature ofthe device during the design process, it is necessary toapply an accurate thermal model. It is necessary of atrade-off between thermal distribution accuracy (direc-tions through heat transfer is considered, constant ther-mal properties, feedback with the magnetic model,steady state models, etc) and the complexity of the ther-mal model that is obtained.

    Losses in the magnetic components are important designparameters. In many high-frequency designs, magnets arelimited by their losses. Thus, it is extremely important forthe designer to have a good practical model for estimatingthe losses under various excitations that are frequently en-countered in power electronics design. There are two majorcomponents of the losses [1-9] in a magnetic component:the core loss (i.e., the losses in the magnetic material whichis used as core) and the winding losses. High-frequency

    conductor losses for power electronics applications havebeen considered by a number of authors [8,9]. There aremodels provided by different manufacturers [10-12], that

    are synthesized in a simple expression for the calculation ofthe temperature rise. They provide the average temperaturein the outer surface of the device.

    Most of thermal models for magnetic components areanalytical and assume 1D heat transfer [13-15]. Thesemodels are based on thermal networks and commonlyconsider only steady state, constant thermal properties,concentrated and uniform power losses and no thermalfeedback with the electric properties. However, the ther-mal distribution is 2D/3D for most of cases, even if themagnetic field exhibits a 1D distribution.

    The thermal design is usually somewhat neglected asit is often not clear which theory and coefficients should

    be used and experiments are time consuming. In thisarticle, by designing a typical high-frequency trans-former with ferrite core, its thermal behavior is investi-gated. Many parameters such as flux density, windingloss value, using a fan to cool the winding and core andthermal conductivity have effects on the ferrite tempera-ture which is simulated with ANSYS software.

    2. Calculating the Heat Generation Causedby Winding and Investigating ItsEffective Parameters

    Heat generating sources are transformer windings which

    mailto:hfeshki%[email protected]:hfeshki%[email protected]
  • 8/3/2019 Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method

    2/6

    Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method628

    generate heat by passing the current and this heat is

    transmitted to other parts. For a winding with resistance

    Rj, the power loss can be written as:

    2

    ,cu j j jP I R (1)

    Which the jth winding resistance is as follow:

    ,

    j

    j

    w j

    lR

    A (2)

    Where:

    j jl n MLT (3)

    ,

    A u j

    w j

    j

    W KA

    n

    (4)

    In Equation (3), MLT is mean length per turn (cm). By

    considering Equation (2) to Equation (4), the power loss

    of jth winding is as follow:

    2 2

    ,

    j j

    cu j

    A u j

    n i MLT P

    W K

    (5)

    And the total power dissipation is the sum of the power

    losses for each winding:

    2 2,

    1

    kj

    cu tot jA u j

    n IMLTP

    W K

    (6)

    The loss in winding is optimal providing that [16]:

    , 1

    k

    cu tot j jjA u

    MLT

    P W K

    n I (7)

    According to Equation (7), it can be found out that the

    power loss or generated heat depends on parameters such

    as (wire effective resistivity), Ku (winding fill factor),

    turns, winding current and MLT (mean length per turn).

    So, these are effective parameters on generation heat

    source. In a transformer, if the primary voltage is like

    Figure 1, then the following equations will be written:

    2

    11 1

    t

    tv t dt (8)

    1

    max 11 m2 2c cB n

    n A B A

    1

    ax

    (9)

    By substituting Equation (9) in Equation (7), the result

    can be written as:

    2 2 22 11 2 2

    1tot totcu

    A u u A c max

    A B C

    MLT I MLT IP n

    W K k W A B

    (10)

    where:

    1 1

    kj

    tot jj

    nI I

    n

    Area 1

    t1 t2

    Vg

    -Vg

    0 0

    v1(t)

    Figure 1. Transformer primary voltage.

    Equation A i

    lectrical ore and

    (10) consists of three parts in which part

    characteristics and B and C include c

    s

    e

    magnetic characteristics respectively.

    The core loss is obtained from the following equation:

    e fe max c mP k B A l (12)

    Kfefrequencies. Ac is core cross-section

    agnet

    and its effec-

    tiv rmer for full bridge con-

    is core loss coefficient which is different for variousal area and lm is

    m ic path length. The typical value of for ferritecore is 2.6 < < 2.8. Kfe is drastically increased by in-creasing the frequency. In addition, Kfe depends on coretemperature and Bmax. The dependency of Kfe on fre-quency, Bmax and temperature can be obtained from corecharacteristics. In choosing the core when combined withdifferent alloys, there has been always trade-off betweensaturated magnetic flux density and the core loss. Usingmaterials with high Bsat leads to volume, size and pricereduction. But these materials cause more core loss.

    3. Transformer Characteristic forFull-Bridge Converter

    To study the temperature rise in ferrite core

    e parameters, a sample transfo

    verter with two secondary windings and one primary

    winding is chosen which can be seen in Figure 2 [16].

    Figure 2. Transformer for full bridge converter with two

    outputs and one input.(11)

    Copyright 2010 SciRes. JEMAA

  • 8/3/2019 Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method

    3/6

    Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method 629

    Table 1. Parameters of designed transformer for full bridge

    converter

    75kHzTransformer frequency

    110 :5 :15ratioTurn

    0.75Duty cycleEE40

    Selected core

    /T cm3

    410 -cm

    -sec

    x

    0 mW

    7.6 Wkfe

    2.6

    0.25-6

    Ku

    1.72

    800 V1

    5.7 AI1

    66.1 AI2

    9.9AI3

    14.4 AItot

    80 mTBma

    22n1

    1n2

    3n3

    23Pfe

    3.89 WPcu

    4.12 WPtot

    The ined parameters for th mer are listed

    in ble 1. The core and winding losses calculated for

    tra

    indings isFigure 3.

    in Table 2.

    that the heat transfer be-

    the transformer has been

    obta is transfor

    Ta

    nsformer are equal to 230 mW and 3.89 W respectively.

    These losses can be used as heat generating source in

    modeling and simulating the transformer in ANSYS.

    4. Transformer Modeling in ANSYS

    In this part, transformer with two secondary wmodeled in ANSYS software which is shown in

    The distance between each winding is 0.5 mm. the pri-

    mary winding is 20 mm long and 2 mm wide which this

    cross-sectional area includes 22 turns primary winding.

    This area for secondary winding is 20 mm2 (1 mm 20

    mm) which is for one turn. Also, another secondary

    winding is 20mm long and 0.5mm wide which consists of

    three turns.

    The electrical and thermal characteristics for different

    parts of transformer are listed

    5. Simulation Results

    In this simulation, it is assumed

    tween winding and core of

    naturally done (natural convection). So, the film coeffi-

    cient varies from 10 W/m2C to 25 W/m2C when there

    is natural convection. The film coefficient is considered

    equal to 10 W/m2C. The total cross-section of area is 70

    mm2 and the power dissipation in this area is 3.89W.

    Therefore, the value of watt per square meter of area is

    equal to 55570 W/m2 which is used for heat generation

    source in ANSYS. In Figure 4, temperature distribution

    CoreWinding

    Air

    Air

    Figure 3. Modeled transformer in ANSYS.

    Table.2 ifferent

    arts of transformer

    Electrical and thermal characteristics for d

    p

    MaterialParameter

    AirFerrite CoreCopper

    1.098900Density, 3] 8900 [kg/m

    1006750387Specif kgC]

    T ,

    ic heat, c [J/

    0.0270.004385hermal conductivity

    [W/(mK)]

    Figure 4. Thermal distribution in transformer.

    throug ottest

    oint is primary winding and middle leg of ferrite core

    h the transformer is shown. In this figure, the h

    p

    which is about 61.962C. By paying attention to this fig-

    ure, it is clear that the core corners have lower tempera-

    ture in comparison with other parts. It should be noticed

    that in this case, the secondary windings temperature are

    lower than that in primary one. The heat distribution in

    ferrite core is shown in Figure 5.

    Copyright 2010 SciRes. JEMAA

  • 8/3/2019 Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method

    4/6

    Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method630

    Figure 5. Thermal distribution in core.

    Therma and it is

    m ized in primary winding corners which are about

    42

    ity variation on tem-

    has been investigated.

    . In

    l flux in this case is shown in Figure 6

    axim

    8.69 W/m2. Regarding this matter and according to

    Figure 4, it can be pointed out that the corners tempera-

    tures are lower than that in other parts.

    5.1. Variation of Flux Density

    In this part, the effect of flux dens

    perature distribution in transformer

    For this purpose, the flux density is decreased from 80 mT

    to 120 mT. According to Equation (10), the power loss is

    in inverse proportion with the square of flux density and

    by this change, the power loss is decreased 2.25 times.

    The heat distribution for this condition is shown in

    Figure 7 in which the hottest point is about 55.309C

    Figure 7. Thermal distribution in transformer (Decreasin

    is case, one of the secondary windings temperatures

    sed in

    gure 4 with Figure 8, we can maketh

    2C to 120

    the fan, almost all windings have the same

    te

    g a Fan to Cool the Core

    cooled by a fan

    to this figure, the core ambient temperature is almost

    g

    flux density).

    th

    (neighbor of primary winding) is approximately equal to

    primary winding temperature (the highest temperature).

    5.2. Variation of the Ambient Temperature

    In this case, it is supposed that the transformer is u

    40C temperature. So, it is observed that the maximum

    temperature inside the transformer has been slightly in-

    creased and has reached to 61.971C. In this case, the

    maximum temperature is in primary winding and core

    middle leg as well.

    By comparing Fie conclusion that regarding the proximity of core sides

    to heat source and warmer environment, the sides tem-

    perature are higher than that in up and down of core.

    5.3. Using a Fan to Cool the Winding

    The film coefficient varies from 50 W/m

    W/m2C when there is forced convection. For this case

    the film coefficient has been changed from 10 W/m2C

    to 50 W/m2C. The temperature distribution is shown in

    Figure 9.

    By using

    mperature of 52.508C. By comparing this figure with

    Figure 4, it can be understood that using the fan leads to

    winding temperature reduction from 61.962C to

    52.508C. By this analysis, the appropriate fan can be

    chosen.

    5.4. Usin

    In this case, it is supposed that core is

    (the film coefficient is 50 W/m2.C). The heat distribu-

    tion in this condition is plotted in Figure 10. According

    Figure 6. Thermal flux in transformer.

    Copyright 2010 SciRes. JEMAA

  • 8/3/2019 Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method

    5/6

    Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method 631

    Figure 8. Thermal distribution in transformer (Increas ng

    the ambient temperature).

    i

    Figure 9. Thermal distribution in transformer (Using fan to

    cool the winding).

    shows that changing the film coeffi-

    ient causes suitable increase in core temperature

    nductivity

    W/(m.K).

    ffect (61.95C) on the temperature but the ther-

    m

    ermal behavior of different cores has

    his purpose, first for a typical trans-

    equal. This figure

    c

    (61.95C).

    5.5. Variation of Thermal Conductivity

    On of the other studied parameters is thermal co

    that it is changed from 0.004 W/(mK) to 0.008Thermal distribution for this mode is shown in Figure

    11.

    This figure shows that the thermal conductivity has a

    little e

    aldistribution around the transformer is uniform as a

    circle from centre of transformer.

    6. Conclusions

    In this paper, the th

    been studied. For t

    Figure 10. Thermal distribution in transformer (Using fan to

    cool the core).

    Figure 11. Thermal distribution in transformer (Increasing

    thermal conductivity).

    heat is computed then it is totally

    imulated in ANSYS software. In this simulation, the

    s-

    fo

    former, the generation

    s

    thermal analysis and heat distribution were studied. Then,

    the effects of parameters such as flux density, winding

    loss value, the film coefficient have been investigated.

    According to obtained results, in case of using a fan tocool the winding, the maximum temperature of tran

    rmer has been decreased. Furthermore, it was shown

    that by decreasing the flux density, the temperature of

    the hottest point in transformer has been decreased which

    is due to the power loss reduction in windings. Moreover,

    it is explained in the paper that the core temperature can

    be controlled by increasing the film coefficient (by using

    a fan). As a result, with the findings of this analysis, an

    appropriate fan can be chosen in order to cool the whole

    transformer. In the paper, it is also elaborated that the

    Copyright 2010 SciRes. JEMAA

  • 8/3/2019 Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method

    6/6

    Analysis of Thermal Behavior of High Frequency Transformers Using Finite Element Method

    Copyright 2010 SciRes. JEMAA

    632

    REFERENCES

    [1] S. N. Talukda steresis Models for System Studie n Power Appa

    , pp.

    gic, McGraw-Hill, New York, 1969.

    rromagnetic Materi-

    h Diagrams, IEEE Transaction

    EE

    Wire effective resistivity (-cm)

    I Total rms winding current, ref to primary (A)

    /n1, n3/n1, etc

    ion (W)

    t (W/cm3T)

    area (cm2

    )

    core corners have the lower temperature in comparison

    with other parts. This part has the maximum thermal flux

    as well.

    r and J. R. Bailey, Hys,IEEE Transactions o

    [9]

    ratus [10] Power Conversion and Line Filter Applications.and Systems, Vol. 95, No. 4, 1976, pp. 1429-1434.

    [2] C. C. Wong, A Dynamic Hysteresis Model, IEEETransactions on Magnetics, Vol. 24, No. 2, 19881966-1968.

    [3] D. R. Bennion, H. D. Crane and D. Nitzan, DigitalMagnetic Lo

    [4] F. Presiach, On the Magnetic Aftereffect,Zeitschrift frPhysik, Vol. 94, 1935, pp. 227-302.

    [5] R. D. Vecchio, An Efficient Procedure for ModelingComplex Hysteresis Processes in Fe

    als, IEEE Transactions on Magnetics, Vol. 16, No. 5,1980, pp. 809-811.

    [6] D. L. Atherton, B. Szpunar and J. A. Szpunar, A NewApproach to Presiac on [1Magnetics, vol. 23, No. 3, May 1987, pp. 1856-1865.

    [7] B. Szpunar, D. Atherton and M. Schonbachler, An Ex-tended Presiach Model for Hysteresis Processes, IETransactions on Magnetics, Vol. 23, No. 5, 1987, pp.3199-3201.

    Nomenclature

    [8] J. P. Vandelac and P. D. Ziogas, A Novel Approach forMinimizing High Frequency Transformer CopperLosses,IEEE Transaction on Power Electronics, Vol. 3,No. 2, 1988, pp. 266-277.

    B. Carsten. High Frequency Conductor Losses in Switched

    Mode Magnetic, in Proc. HFPC Con$ Ventura, CA:Intertec Communications Inc., May 1986.

    [11] Design of low profile high frequency transformers-A newtool in SMPS design-. Philips Magnetic Products. Appli-cation note. May.1990.

    [12] Kool Mu Powder Cores Data Book. Magnetics.[13] L. M. Escribano, R. Prieto, J. A. Cobos and J. Uceda,

    Thermal Modeling of Magnetic Components: A Survey,Proceeding of 28th Annual Industrial Electronics SocietyConference of the IEEE, Sevilla, 5-8 November 2002, pp.1336-1341.

    [14] L. M. Escribano, R. Prieto, J. A. Oliver, J. A. Cobos and J.Uceda, Analytical Thermal Model for Magnetic Com-ponents,Proceedings of 34th AnnualPower ElectronicsSpecialist Conference of the IEEE, 2003, pp. 861-866.

    5] J. C. S. Fagundes, A. J. Batista and P. Viarouge, ThermalModeling of Pot Core Magnetic Components Used inHigh Frequency Static Converters,IEEE Transactions onMagnetic, Vol. 33, No. 2, March 1997, pp. 1710-1713.

    [16] R. W. Ericksonand D. Maksimo, Fundamentals of PowerElectronics, 2nd Edition, Springer, Berlin, 2002.

    tot

    n2 Desired turns ratios (V-sec)

    1

    P

    Applied primary volt-sec

    tot

    K

    Allowed total power dissipat

    u

    Winding fill factor

    Core loss exponent

    K fe

    A

    Core loss coefficien

    c

    W

    Core cross-sectional )

    Core window area (cm2)A

    MLT

    l

    Mean length per turn (cm)

    e

    A 1, Magnetic path length (cm

    w

    B

    Wire areas (cm2)

    Peak ac flux density (T)

    http://www.amazon.com/Robert-W.-Erickson/e/B001HOFSRI/ref=sr_ntt_srch_lnk_1?_encoding=UTF8&qid=1278960647&sr=1-1http://www.amazon.com/Robert-W.-Erickson/e/B001HOFSRI/ref=sr_ntt_srch_lnk_1?_encoding=UTF8&qid=1278960647&sr=1-1