analysis on tec expressline ii modules
DESCRIPTION
Analysis on TEC Expressline II modules. Two different topics: Strip defects (3 modules) Global IV (2 modules). Good & Bad news: Add. Pinholes No problem due to bonding!. 3 (+2 later) additional pinholes were reported by Aachen wrt QTC in Vienna! - PowerPoint PPT PresentationTRANSCRIPT
Frank Hartmann 10.04.03
Module Construction Meeting 1
Analysis on TEC Expressline II modules
Two different topics: • Strip defects (3 modules)• Global IV (2 modules)
Frank Hartmann 10.04.03
Module Construction Meeting
Good & Bad news: Add. PinholesNo problem due to bonding!
3 (+2 later) additional pinholes were reported by Aachen wrt QTC in
Vienna!Investigated in KA with QTC and DAQ!1. 3 pinholes were related to deep scratches!2. 1 burn!?!3. 1 misstag
Module 644 strip 358Reported add. pinhole!
Frank Hartmann 10.04.03
Module Construction Meeting
Scratches:sensor defects (mod 642)
100 200 300 400 5001E-10
1E-9
1E-8
1E-7
Module 642Leakage current
Leak
age
curr
ent [
A]
Stripnumber
200 300 400 500
0,0
2,0x10-6
4,0x10-6
6,0x10-6
8,0x10-6
1,0x10-5
1,2x10-5
module 642Pinhole measurement
Idie
l [A
]
stripnumber 320 322 324 326 328 330 332 334 336 338 340
2,0x10-6
4,0x10-6
6,0x10-6
8,0x10-6
1,0x10-5
1,2x10-5
module 642 Pinhole measurementExploded view
Idie
l [A
]
stripnumber
320 322 324 326 328 330 332 334 336 338 34010-10
10-9
10-8
10-7
module 642Leakage current Exploded view
Leak
age
curr
ent [
A]
Stripnumber
Strip 330: pinhole
Strip 328: leaky
1 Scratch from strip 327 to 331 produced 2 different defects!
Module 642 strip 329,330,331
Frank Hartmann 10.04.03
Module Construction Meeting
Module 642 -- strip scan on module
100 200 300 4001,00E-010
2,00E-010
3,00E-010
4,00E-010
5,00E-010
6,00E-010
module 642
Cou
plin
g ca
paci
tanc
e [F
]
stripnumber
Coupling capacitances: all in specsOverflow @ strip 330 pinhole
0 100 200 300 400 500 6001,5x106
2,0x106
2,5x106
module 642Rpoly
Rpo
ly [O
hm]
Stripnumber
Rpoly: all in specs
NB. Strip 1 reported as a pinhole:1. is dubious in the DAQ, but not clearly identifiable as pinhole!2. shows no damage!3. is no pinhole according to the Idiel measurement at QTC!
Frank Hartmann 10.04.03
Module Construction Meeting
Mod 643 add pinholes betweenDEC02 to JAN03
Strip 221
Strip 511More on this one later
This happened somewhereafter the first module tests!
Frank Hartmann 10.04.03
Module Construction Meeting
IV
Frank Hartmann 10.04.03
Module Construction Meeting
IV problems reported by Aachen
• For a “good” IV evaluation (with a dubious first one) one should take at least fast 2-3 IV ramps
OR ramp up – wait – IV during ramp down.• The stepping of 100V done in Aachen was not suited for full
modules (there’s a chance for higher values)
Module 642 is fine (more on this) (mod 503 fine up to ~500V, then fast increase to ~10µA to be investigated).
Module 643: early breakdown at 100-200V (more on this one)
Frank Hartmann 10.04.03
Module Construction Meeting
Module 642 High IV + early soft breakdown
-50 0 50 100 150 200 250 300 350 400
2,0x10-6
2,5x10-6
3,0x10-6
3,5x10-6
4,0x10-6
module 642I-t @ Vbias = 500V
Glo
bal l
eaka
ge c
urre
nt [A
]
Time [s]
0 100 200 300 400 500-5,0x10-7
0,05,0x10-71,0x10-61,5x10-62,0x10-62,5x10-63,0x10-63,5x10-64,0x10-6
IV on module 642 (2 sensors)
Glo
bal l
eaka
ge c
urre
nt [A
]
Voltage [V]
Slight but non-criticalincrease in IV! Compare to the 40µA limit! Initial current decrease with time!
Known IV behaviour of sensors!
4µA
2µA
Frank Hartmann 10.04.03
Module Construction Meeting
Mod 643 High IV + early soft breakdown
Frank Hartmann 10.04.03
Module Construction Meeting
IV reported by AachenMod 643
First IV is fine!
´What happened?
Frank Hartmann 10.04.03
Module Construction Meeting
Module 643 (history)
• Full module shows high global IV• Optical inspection showed possible candidates for the high IV,
– NO candidates on the edges– NO; on the visible part of the backplane.– Yes; on strip level– Yes; on bias / guard region
• Strip scan (leakage current) on W6A (on module) show nominal currents (W6B not accessible)
Removal of bonds (for further deep investigation on indiv. Sensors.)
Frank Hartmann 10.04.03
Module Construction Meeting
Module 643 history (cont.)
• IV on W6A is ok, IV on W6B shows early breakdown as full module!• Cleaning improved the current but did not solve the problem:
– A) Isoprop, B) isoprob plus tissue, (C) ultrasonic bath)• Strip scans (leakage current) on both sensors show nominal currents! IV problem is NOT located in the strip region!
Remaining defect location: Backside, Guard-, Bias, n++ -region!
Removal of W6B with a scalpel no further increase in IV!NO visible breaks on the backplane (add. inspection on the edges)
Remaining defect location: Guard-, Bias, n++ -region!
Frank Hartmann 10.04.03
Module Construction Meeting
IV on module 643
Closer investigationon W6B SENSOR
Starting assumption:1. indiv. strip failure
as seen on sensors2. backplane cracks/chips3. guard scratches4. bias scratches5. contact of guard and n++
0 100 200 300 400 500 60010-8
10-7
10-6
10-5
10-4
10-3Module 643 (bonds removed)
leakage current of W6B leakage current of W6A
Glo
bal l
eaka
ge c
urre
nt [A
]
Voltage [V]
Frank Hartmann 10.04.03
Module Construction Meeting
Module 643 Strip leakage current
Individual strip currents are as expected for HPK (very low)! Other strip parameters checked for are in specs!
100 200 300 400 5000,0
2,0x10-9
4,0x10-9
6,0x10-9
8,0x10-9
module 643 strip leakage currentSUM = 300nA
Str
ip le
akag
e cu
rren
t [A
]
stripnumber
Sum of individual currents is way below the total current!(Nominal values)
Frank Hartmann 10.04.03
Module Construction Meeting
Backside – not criticalNon critical scratches on the backside compare with
scratch tests on the backside and scalpel scratches
(during removal), which did not increase the current.Exististing scratch
Non-destructive teston mini sensor
Scalpel wounds during removal Non-destructive!
Scratches on the backare probably notcritical.
Frank Hartmann 10.04.03
Module Construction Meeting
Scratch on n++,guard and bias
Scratch exists before end of bonding!
Possible defect candidate:Metal overhang defect!
Frank Hartmann 10.04.03
Module Construction Meeting
0 200 400 600 800 10000,0
2,0x10-94,0x10-96,0x10-98,0x10-91,0x10-81,2x10-8
No scratch on minisensor
Tot
al le
akag
e cu
rren
t [A
]
Voltage [V]
0 200 400 600 800
2.0x10-6
4.0x10-6
6.0x10-6
8.0x10-6
1.0x10-5
Scracht on bias and guard Exploded view
Tot
al le
akag
e cu
rren
t [A
]
Voltage [V]
Scratch test on bias & guard (minisensor)
Artifical:
Metaloverhang defect
Frank Hartmann 10.04.03
Module Construction Meeting
Preliminary field simulations (with ISE TCAD)
Frank Hartmann 10.04.03
Module Construction Meeting
Module 643 (strange)
On strip
On n++
Possible defect candidate:Short: n++ and guard
Most probable candidate!
Frank Hartmann 10.04.03
Module Construction Meeting
IV with “shorts” in the outer sensor areas
0 200 400 600 800 10001E-12
1E-11
1E-10
1E-9
1E-8
1E-7
1E-6
1E-5
1E-4
1E-3
IV standard (guard floating) IV Guard on GND IV Guard only IV Bias + Guard IV Bias (Guard shorted to n++) IV Bias (Guard 1MOhm to n++) IV Bias (Guard shorted to n++) IV Bias (Guard 10MOhm to n++)
Glo
bal l
eaka
ge c
urre
nt [
A]
Voltage [V]
-10 0 10 20 30 40 50 601E-10
1E-9
1E-8
1E-7
1E-6
1E-5
1E-4
1E-3
Glo
bal l
eaka
ge c
urre
nt [
A]
Voltage [V]
Frank Hartmann 10.04.03
Module Construction Meeting
Repair of module 643
Repair is feasible but not applicable as standard procedure! Not fully bonded yet.
Frank Hartmann 10.04.03
Module Construction Meeting
0 100 200 300 400 500 6000,00E+000
2,00E-008
4,00E-008
6,00E-008
8,00E-008
1,00E-007
1,20E-007
1,40E-007
1,60E-007
1,80E-007
undamaged small scratch with needle deep scratch with needle scratched with pencil 2B scratched with screwdriver
curr
en
t [A
]
bias voltage [V]
x3
0 100 200 300 400 500 600
1E-10
1E-9
1E-8
strip 5 (not damaged) strip 8 strip 9 strip 10 strip 11 strip 13
stri
p c
urr
en
t [A
]bias voltage [V]
x70
Total current Single strip current
GENERAL: Global IV and Individual strip IV (sensors) Scratches on QTC level! (e.g. from company or artificial)
Frank Hartmann 10.04.03
Module Construction Meeting
General comment on scratches!During Assymbly, Bonding, Testing
• DO NOT SCRATCH SENSORS / DO NOT POLLUTE THEM!!
– especially not the guardring !
– especially not the strips !
– do not break the edges !
– do not break any border line !
• SMALL SUPERFICIAL scratches are enough to change sensor/module characteristics!
1. Local & global HIGH increase of current
2. Add shorts, breaks, pinholes!
Contrary to older experiments: The high voltage sensor design is good but vulnerable to scratches!
Pollution: Use Facemasks everywhere working with open sensors/modules!
Frank Hartmann 10.04.03
Module Construction Meeting
W5 prototype production (manual)
Frank Hartmann 10.04.03
Module Construction Meeting
IV on W5
0 100 200 300 400 500 600
0,0
5,0x10-7
1,0x10-6
1,5x10-6
2,0x10-6
2,5x10-6
W5 modules (STR & KA)
S: IV on sensor before assemblyM: IV on sensor after assembly on module
m21054618 m21054615 m21054619 m21054621 m23296312 m23296324 m23296511 m23296515 S23296324 S23296511 S23296515 S23296312 S21054615 S21054618 S21054619 S21054621G
loba
l lea
kage
cur
rent
[A]
Voltage [V]