anderlei t, bürgin t, richter a, kühner ag, switzerland ...€¦ · anderlei t, bürgin t,...

1
0 10 20 30 40 50 60 100 200 250 shaking frequency [1/min] mixing time 600mL TubeSpin 60 mL 120 mL 240 mL Orbital shaken bioreactors in the field of cell cultivation Anderlei T, Bürgin T, Richter A, Kühner AG, Switzerland Tissot S, Monteil D, Wurm FM, EPFL, Switzerland Bürki C, ExcellGene SA,Switzerland Adolf Kühner AG Dinkelbergstr. 1, CH-4127 Birsfelden (Basel) Switzerland fon: +41 61 319 9393, www.kuhner.com Kuhner Shaker Inc. 295 Old County Raod, unit 11 San Carlos, CA 94070, USA fon: +1 650 595 1997, [email protected] partner of Orbital shaking technology has been widely used in biotechnology because it offers ease-of-use, increased flexibility and reduced costs. Recently, orbital shaken bioreactors of capacities from 1mL - 2500L have been employed for cultivation of mammalian cells and are expected to become attractive alternatives to conventional stirred-tank bioreactors. Efficient mixing in shaken bioreactors is essential in order to avoid concentration gradients which can be harmful for mammalian cells. Therefore the mixing time in the different scales should be in the same range. 50-2500L scale 200-2000mL scale 10-100mL scale shaker orbital shaking 20mL 100mL 10L 1mL 200L 2500L 0 20 40 60 80 100 120 140 160 180 200 30 35 40 45 50 55 60 shaking frequency [1/min] mixing time in the SB2500-X (ORBShake 2500) 2500L 2000L 1500L 1000L 500L mixing time [s] 0 20 40 60 80 100 120 140 160 180 200 40 45 50 55 60 65 70 75 shaking frequency [1/min] mixing time in the SB200-X (ORBShake 200) 200L 150L 125L 100L mixing time [s] mixing time [s] 0 10 20 30 40 50 60 100 200 250 shaking frequency [1/min] mixing time 50mL TubeSpin 5 mL 10 mL 20 mL mixing time [s] shaking diameter 50mm shaking diameter 50mm shaking diameter 100mm shaking diameter 50mm shaking diameter 50mm shaking diameter 50mm 0 10 20 30 40 50 60 100 200 250 shaking frequency [1/min] mixing time 2000mL roller bottle and 5000mL Thomson flask 200 mL 400 mL 800 mL 400 mL 800 mL 1600 mL Roller Bottle Thomson Flask mixing time [s] Þ shaken bioreactors have a very consistent mixing time across all scales (less than 60 sec.) no mixing no mixing no mixing 0 10 20 100 200 shaking frequency [1/min] mixing time 250mL Erlenmeyer flasks with and without baffles 25 mL without baffles 25 mL with baffles 50 mL without baffles 50 mL with baffles 100 mL without baffles 100 mL with baffles 30 40 50 60 mixing time [s] factor 50'000

Upload: others

Post on 26-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Anderlei T, Bürgin T, Richter A, Kühner AG, Switzerland ...€¦ · Anderlei T, Bürgin T, Richter A, Kühner AG, Switzerland Tissot S, Monteil D, Wurm FM, EPFL, Switzerland Bürki

0

10

20

30

40

50

60

100 200 250

mixing

time

[s]

shaking frequency [1/min]

mixing time 600mL TubeSpin

60 mL

120 mL

240 mL

Orbital shaken bioreactors in the field of cell cultivation

Anderlei T, Bürgin T, Richter A, Kühner AG, SwitzerlandTissot S, Monteil D, Wurm FM, EPFL, SwitzerlandBürki C, ExcellGene SA,Switzerland

Adolf Kühner AGDinkelbergstr. 1, CH-4127 Birsfelden (Basel)Switzerlandfon: +41 61 319 9393, www.kuhner.com

Kuhner Shaker Inc.295 Old County Raod, unit 11San Carlos, CA 94070, USAfon: +1 650 595 1997, [email protected]

partner of

Orbital shaking technology has been widely used in biotechnology because it offers ease-of-use, increased flexibility and reduced costs. Recently, orbital shaken bioreactors of capacities from 1mL - 2500L have been employed for cultivation of mammalian cells and are expected to become attractive alternatives to conventional stirred-tank bioreactors. Efficient mixing in shaken bioreactors is essential in order to avoid concentration gradients which can be harmful for mammalian cells. Therefore the mixing time in the different scales should be in the same range.

50-2500L scale

200-2000mL scale

10-100mL scale

shaker

orbitalshaking

20mL

100mL

10L

1mL

200L

2500L

0

20

40

60

80

100

120

140

160

180

200

30 35 40 45 50 55 60

mixing

time

[sec]

shaking frequency [1/min]

mixing time in the SB2500-X (ORBShake 2500)

2500L

2000L

1500L

1000L

500L

mix

ing

tim

e [

s]

0

20

40

60

80

100

120

140

160

180

200

40 45 50 55 60 65 70 75

mixing

time

[sec]

shaking frequency [1/min]

mixing time in the SB200-X (ORBShake 200)

200L

150L

125L

100L

mix

ing

tim

e [

s]

mix

ing

tim

e [

s]

0

10

20

30

40

50

60

100 200 250

mixing

time

[s]

shaking frequency [1/min]

mixing time 50mL TubeSpin

5 mL

10 mL

20 mL

mix

ing

tim

e [

s]

shaking diameter 50mm shaking diameter 50mm

shaking diameter 100mm

shaking diameter 50mm

shaking diameter 50mm

shaking diameter 50mm

0

10

20

30

40

50

60

100 200 250

mixing

time

[s]

shaking frequency [1/min]

mixing time 2000mL roller bottle and 5000mL Thomson flask

200 mL

400 mL

800 mL

400 mL

800 mL

1600 mL

Roller Bottle

Thomson Flask

mix

ing

tim

e [

s]

Þ shaken bioreactors have a very consistent mixing time across all

scales (less than 60 sec.)

no m

ixin

g

no m

ixin

g

no m

ixin

g

0

10

20

100 200

m

shaking frequency [1/min]

mixing time 250mL Erlenmeyer flasks with and without baffles

25 mL without baffles 25 mL with baffles

50 mL without baffles 50 mL with baffles

100 mL without baffles 100 mL with baffles

30

40

50

60

ixing

time

[s]

mix

ing

tim

e [

s]

facto

r 50'0

00