annex b2 technical specifications lot 2 civil works kohat ... · provding and laying porceline tile...

35
S.NO MRS-2017 Description Unit Quantity 1 03-23-b Excavation in foundation of building, bridges etc complete in ordinary soil Cft 2174.000 2 26-15 Spraying anti-termite liquid mixed with water in ration of 1:40 Sft 1000.000 3 06-05-i P/L: P.C.C 1:4:8 in any part of building such as foundation, etc. using 1½" down graded stone aggregate i/c form-work, placing, compacting, leveling and curing etc. Complete as per specification and instructions of Engineer incharge. Cft 343.338 4 06-06-a-03 P/L: RCC 1:2:4 i/c using approved quality of crushed stones and fine agregate (sand) in roof slab, landing, wall, plienth beam & bands including mixing in concrete mixer, lifting, placing in steel fom work, vibrating, consolidating, dressing, levling and curing excluding the cost of re-inforcement bars and the cost of laborty quality test. Complete in all respect as per specification and instruction of Engineer incharge. Cft 1352.720 5 06-07-c PF in position mild reinforcement defomed bars (40000 psi yield strength) of any size and diameter including straightening , bending, placing, binding in position with binding wire, placing spacers. Complete in all respects as per specification and instruction of Engineer incharge. M.Ton 5.438 6 06-22-a-02 DPC of cement concrete 1:2:4 including bitumen coat , one layer polythene and one coat bitumen ( 2" thick) Sft 147.225 7 07-04-a-03 P/L: 1st class approved solid BB masonry in walls over 115mm thicks, laid and jointed in CM 1:4, straight or to corve with inner radious of 6m and over, upto 4.25m depth, including racking out the joints where necessary scaffolding & curing etc. Complete in all respect as per specification and instruction if Engineer incharge. Cft 569.625 8 07-05-a-03 P/L: 1st class approved solid BB masonry in walls 115mm thicks, laid and jointed in CM 1:4, straight or to curve with inner radious of 6m and over, upto 4.25m depth, including racking out the joints where necessary scaffolding & curing etc. Complete in all respect as per specification and instruction if Engineer incharge. Cft 1126.922 9 11-09-b P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand mortar includind scafolding, chambering of edges, rounding the corners , making groves and edges where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12" wide at all joints of R.C.C and brick work, curing, cleaning, complete in all respect, specifications and instructions of engineer incharge. Sft 5023.969 Annex B2 Technical Specifications LOT 2 Civil Works Kohat BHU Nakaband Page 1 of 35

Upload: others

Post on 20-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

  • S.NO MRS-2017 Description Unit Quantity

    1 03-23-b Excavation in foundation of building, bridges etc complete in ordinary soil Cft 2174.000

    2 26-15 Spraying anti-termite liquid mixed with water in ration of 1:40 Sft 1000.000

    3 06-05-i

    P/L: P.C.C 1:4:8 in any part of building such as foundation, etc. using 1½" down

    graded stone aggregate i/c form-work, placing, compacting, leveling and curing

    etc. Complete as per specification and instructions of Engineer incharge.

    Cft 343.338

    4 06-06-a-03

    P/L: RCC 1:2:4 i/c using approved quality of crushed stones and fine agregate

    (sand) in roof slab, landing, wall, plienth beam & bands including mixing in

    concrete mixer, lifting, placing in steel fom work, vibrating, consolidating, dressing,

    levling and curing excluding the cost of re-inforcement bars and the cost of laborty

    quality test. Complete in all respect as per specification and instruction of Engineer

    incharge.

    Cft 1352.720

    5 06-07-c

    PF in position mild reinforcement defomed bars (40000 psi yield strength) of any

    size and diameter including straightening , bending, placing, binding in position

    with binding wire, placing spacers. Complete in all respects as per specification and

    instruction of Engineer incharge.

    M.Ton 5.438

    6 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat , one layer polythene and

    one coat bitumen ( 2" thick)Sft 147.225

    7 07-04-a-03

    P/L: 1st class approved solid BB masonry in walls over 115mm thicks, laid and

    jointed in CM 1:4, straight or to corve with inner radious of 6m and over, upto

    4.25m depth, including racking out the joints where necessary scaffolding & curing

    etc. Complete in all respect as per specification and instruction if Engineer

    incharge.

    Cft 569.625

    8 07-05-a-03

    P/L: 1st class approved solid BB masonry in walls 115mm thicks, laid and jointed in

    CM 1:4, straight or to curve with inner radious of 6m and over, upto 4.25m depth,

    including racking out the joints where necessary scaffolding & curing etc. Complete

    in all respect as per specification and instruction if Engineer incharge.

    Cft 1126.922

    9 11-09-b

    P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand mortar includind

    scafolding, chambering of edges, rounding the corners , making groves and edges

    where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12" wide at all joints

    of R.C.C and brick work, curing, cleaning, complete in all respect, specifications and

    instructions of engineer incharge.

    Sft 5023.969

    Annex B2 Technical Specifications LOT 2

    Civil Works Kohat BHU Nakaband

    Page 1 of 35

  • 1013-30-a + 2 x 13-

    30-b

    Surface prepartion (for dempenss) by provission of film with Alkali resisting primer

    on plaster wall and ceilling . Including first coat of painting new or old work such

    as walls including all detacheched attachement with plast emulsion paint.

    Including subsequent tywo coats of emulsion paints.

    Sft 5023.969

    11 10-03-a

    Provding sand cushion in lyers as specified under concreet, road, hard standing and

    landing including dressing, leveling, compacting and consolidating as per

    specification and instruction of the Engineer Inchage.

    Cft 540.813

    12 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft 245.149

    13 10-48-aProvding and laying porceline tile floor 1/4 inch thick laid cement 1:2 or 3/4 inch

    thick cement mortar 1:2 (local master tiles)Sft 1435.938

    14 12-07-aFirst class doadar wood wrought joinery in doors and window etc complete : 2 inch

    thickSft 105.000

    15 12-20-a-02 Extra for providing /fixing approved quality rim locks : local Nos 4.000

    16 12-56-a

    Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type chowkat including

    fixing and position with all charges for hold fast hinges and paint etc complete in

    all respect as per drawings and as per specification as directed by engineer

    incharge

    Rft 151.000

    17 25-39-b-03

    Providing and fixing steel window 18 gauge with openable glazed panels with 22

    SWG wire gauze glass pane 3 mm including grill complete in all respect as per

    drawings and specification and as per directed by the engineer incharge

    Sft 111.000

    18 12-49Curtain railing to doors and windows comprising toso-elite japanees railing or

    equivalent inclunding paintRft 18.000

    19 NSI Provision and fixing of blind to windows as per direction of engineer incharge Sft 144.000

    20 24-17-a-01

    Supply and fixing of aproved AC building pipe Class , 80mm with pigot and socket

    joints and hexagonal head for rain water including jointing and suport MS Plate

    19mm x 6mm @ 1m apart. Complet in all respect and in accordance with

    specification and instruction of the Engineer Incharge.

    Rft 26.000

    21 09--05

    Supply and fixing of one lyer of brick tile (300mm x 150mm) x 50mm flat brick on

    roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage), one coat of hot

    bitumen (10 - 15 grade) and one lyer of approve polythene sheet. Complet in all

    respect and in accordance with specification and instruction of the Engineer

    Incharge.

    Sft 1120.000

    22 06-05-h

    P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone aggregate i/c

    form-work, placing, compacting, leveling and curing etc. Complete as per

    specification and instructions of Engineer incharge.

    Cft 43.560

    S.NO MRS-2017 Description Unit QuantityIE-1 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC insulated Each 16.000

    IE-2 15-05-eSupply and Erection 7/.044" single core Copper PVC insulated 250/440 voltage

    grade cable.Rft 400.000

    Internal Electrification works Kohat BHU Nakaband

    Page 2 of 35

  • IE-3 15-81 Supply and fixing 20 ampere power pluge Each 4.000

    IE-4 15-82 Supply and fixing 30 ampere power pluge Each 8.000

    IE-5 15-83 Supply and fixing 10 ampere power pluge Each 6.000

    IE-6 15-68-cSupply and Erection best quality AC ceiling fan completewith GI rod, canopy,

    blades & regulator : 56" sweepEach 4.000

    IE-7 NSI

    Supply & Installation of 12" sweep, plastic body, Exhaust fan including all civil

    works required for complete installation and of Asia/Climax/Pak fan made

    including all labour and materials cable as required at site and as approved by the

    Engineer Incharge. (Exaust fan will be fitted in proper steel frame along with wire

    gauze at external side)

    Each 4.000

    IE-8 15-25 Supply and Erection girder clamp hook, 5/8" dia.for hanging ceiling fan Each 6.000

    IE-9 15-61-aSupply and Erection fluorescent tube light fitting including 4' rod, choke, starter,

    flexible wire etc : SingleEach 10.000

    IE-10 15-53Special Earthing of iron/metal clad switches etc with copper wire No. 8 SWG in GI

    pipe 1/2" diaEach 1.000

    E-11

    15-71-d Supply and Erection single phase imported auto circuit breaker 30 Amp. Each 4.000

    15-71-a Supply and Erection single phase imported auto circuit breaker 6 Amp Each 14.000

    15-71-b Supply and Erection single phase imported auto circuit breaker 15 Amp Each 12.000

    NSISupply and Erection Cubical Type Factory Fabricated floor/wall mounting steel

    main board comp. : RecessedNo 1.000

    IE-9 NSIProviding and fixing of distribution board along with best quality electric button

    and dimmer complete with all accesoories as recommended by the Engineer

    Incharge (Labour room and recovery room)

    No 2.000

    NSIProviding and fixing of distribution board along with best quality electric button

    and dimmer complete with all accesoories as recommended by the Engineer

    Incharge (Wash Room and Verandah)

    No 2.000

    Sub Head MRS-2017 Description Unit Quantity

    Sanitary 14-01-aP/F: European type WC (ICI Boch or equivalent) i/c flush Tanki, P/Trap, Stop Cock,

    Plastic Connection etc. Complete as per specification and instruction of Engineer

    Incharge(Porta , Duur or equivalent )

    Each 5.000

    14-05-b-01Providing and fixing glazed earthen WHB complte with pedistal white size 25" x 18"

    Each 3.000

    14-27 Providing and fixing CP mixing valve for WHB/SHOWER Each 3.000

    14-24-b Providing and Fixing CP bib-cock, heavy type : 1/2" Each 10.000

    14-17P/F: of 22"x16"best quality 5mm mirror glass of approved quality. Complete in all

    respect as per specification and instruction of Engineer incharge.Each 3.000

    14.20 cP/F: best quality towel rail of approved quality as per specification and instruction

    of engineer inchargeEach 3.000

    14.20 bP/F: best quality paper holder of approved quality as per specification and

    instruction of engineer inchargeEach 5.000

    Distribution Board:

    Water Supply and Sanitation Works Kohat BHU Nakaband

    Page 3 of 35

  • 14.20 aP/F: best quality plastic soap dish of approved quality as per specification and

    instruction of engineer inchargeEach 3.000

    14-28-a Providing and Fixing gun metal peet / gate valve (screwed) 1" dia Each 6.000

    14-31-bProviding and Fixing CI floor trap including CI grating & concrete chamber all round

    : 4"x3"Each 2.000

    Water supply 14-55-e Providing and Fixing GI pipe & including specials complete 3/4" dia (light) Rft 800.000

    14-55-f Providing and Fixing GI pipe & including specials complete 1/2" dia (light) Rft 500.000

    14-69-b-03 P/F Fibre Glass Water Tank 400 gallons Each 2.000

    Sewerage 14-70-aProviding and Fixing of pipe type B nikasi system including testing in all respect 110

    mm (using dadex, or eq)Rft 195.000

    14-37-c Supply and Fixing CI manhole cover with frame etc complete 25" dia Each 7.000

    23-Oct Construction of septic tank (7' x 2' x 5') complete in all respect) Each 2.000

    23-NovConstruction of Soakage pit having 6 Rft dia and 10 Rft deep filled with brick and

    brick linning at sideEach 2.000

    NSIConstruction of manholes 2'X2' in size including excavation, backfilling, 9" thick

    brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick cement sand plaster

    complete.

    Each 8.000

    S No. MRS Code 2017 Description Units Nos Length WidthHeight/Dep

    th

    Total

    Quantities1 04-48-b Remove of extra material from roof Sft 1.000 42.000 21.000 882.000

    2 10-15-e PCC (1:2:4) as screeding 2" thick Sft 1.000 42.000 21.000 882.000

    3 11-09-b Cement sand mortor on walls in 1:4 CSM Sft 1.000 1480.000

    4 10-15-eProvide & lay topping of concrete 1:2:4, including surface finishing & dividing in

    panels : 2" thickSft 2.000 12.000 15.000 180.000

    5 10-15-eProvide & lay topping of concrete 1:2:4, including surface finishing & dividing in

    panels : 2" thickSft 2.000 11.000 12.000 132.000

    6 NSIRepairing of Existing Cupboard, replaceing of damage sheets and locks etc

    complete with paint and pannelsSft 2.000 6.000 10.000 120.000

    7 04-24Repairing and fixing of old wooden door in pannels with chowkat, locks and polish

    in wooden color completeSft 6.000 7.000 3.000 126.000

    9 12-51Provide & fix GI wire gauze 22 SWG, 12x12 mesh per sq. in, fixed to steel window

    completeSft 4.000 6.000 4.000 96.000

    10 06-05-f PCC 1:2:4 in the open space of the BHU Cft 2.000 22.000 15.000 0.333 219.780

    11 13-05-c-01 & 02Painting old surfaces : Doors / windows any type First coat & one another coat. In

    3 quarters and their boundary wallsSft 3.000 340.000 10.000 1500.000

    12 14-69-a-02 P/F Fibre Glass Water Tank 400 gallons Each 1.000 1.000 1.000

    13 14-03-aProviding and Fixing glazed earthen ware WC squatting type with built-in foot rests

    : WhiteNo 2.000 2.000 4.000

    14 14-05-a-02 Providing and Fixing glazed earthen ware WHB complete No 2.000 4.000 2.000

    15 14-31-b Floor Trap complete with fitting No 2.000 2.000 4.000

    16 23-02-a Providing and Laying non-reinforced concrete pipe RFT 2.000 80.000 160.000

    Rehabilitation Works Kohat BHU Nakaband

    Page 4 of 35

  • 17 NSI PVC Pipe 4 inch dia Royal or Ill for the sewarage line Each 2.000 80.000 160.000

    19 11-09-b Plaster on the walls in 1:4 CSM Cft 1.000 200.000 0.750 3.000 450.000

    20 14-81-aSupply and fixing of 3.0 HP Monoblock water pump 1.5"x1.5" size 5 stage DE-S5

    model single phase for 220 ft head with all accessories.No 1.000 1.000 1.000

    21 24-02-d-01Tubewell boring in all soils except shingle/rock From 300'

    to 400' below ground : 8" i/dNo 1.000 150.000 150.000

    22 24-12-c-01Providing and installing PVC blind pipe in tubewell with

    strainer BSS Class 'D' working pressure : 6" i/dRft 1.000 -38.000 -38.000

    23 24-09-c-0Providing and installing PVC strainer, in tubewell

    borehole comp. BSS Class 'D' working pressure : 6" i/dRFT 1.000 39.000 39.000

    24 24-14Shrouding with graded pack grave 3/8" to 1/8" around

    tubewell in bore holeCFT 1.000 60.000 60.000

    25 24-30-a-01Providing and Laying HDPE pipe Din-/Din-/ISO-4427

    incl testing & disinfect complete (20mm diaRFT 1.000 160.000 160.000

    26 24-16-c-02Providing and Laying cut, joint, test & disinfect GI pipe

    line Using light quality GI Pipe : 3/4" i/d RFT 1.000 90.000 90.000

    1917-10-b-01 4" thick PCC lining, using washed screened &

    graded/curshed stone aggregate : On slope : Ratio 1:2:4 for wall CFT 2.000 300.000 0.330 0.500 99.000

    21 11-08-a Cement plaster 1:3 upto 20' height 3/8" thick SFT 2.000 200.000 2.500 1000.000

    23 07-05-a-05 Pacca brick work in ground floor Cement, sand mortar 1:6 CFT 1.000 200.000 0.750 2.500 375.000

    2413-05-a-01+2x 13-

    05-a-02

    Painting old corrugated surfaces, pent roofing etc. with oil first and subsequent

    coatSft 2.000 8.000 6.000 0.000 96.000

    S.NO MRS-2017 Description Unit Quantity

    1 03-23-b Excavation in foundation of building, bridges etc complete in ordinary soil Cft 376.000

    2 06-05-i

    P/L: P.C.C 1:4:8 in any part of building such as foundation, etc. using 1½" down

    graded stone aggregate i/c form-work, placing, compacting, leveling and curing

    etc. Complete as per specification and instructions of Engineer incharge.Cft 62.000

    3 06-06-a-03

    P/L: RCC 1:2:4 i/c using approved quality of crushed stones and fine agregate

    (sand) in roof slab, landing, wall, plienth beam & bands including mixing in

    concrete mixer, lifting, placing in steel fom work, vibrating, consolidating, dressing,

    levling and curing excluding the cost of re-inforcement bars and the cost of laborty

    quality test. Complete in all respect as per specification and instruction of Engineer

    incharge.

    Cft 86.760

    4 06-07-c

    PF in position mild reinforcement defomed bars (40000 psi yield strenght) of any

    size and dimetter including straightening , bending, placeing, binding in position

    with binding wire, placing spacesers. Complete in all respects as per specification

    and instruction of Engineer incharge.

    M.Ton 0.350

    5 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat, one layer polythene and

    one coat bitumen ( 2" thick)Sft 39.550

    Waiting Shed Kohat BHU Nakaband

    Page 5 of 35

  • 6 07-04-a-03

    P/L: 1st class approved solid BB masonry in walls over 115mm thicks, laid and

    jointed in CM 1:4, straight or to corve with inner radious of 6m and over, upto

    4.25m depth, including racking out the joints where necessary scaffolding & curing

    etc. Complete in all respect as per specification and instruction if Engineer

    incharge.

    Cft 164.500

    7 07-05-a-03

    P/L: 1st class approved solid BB masonry in walls 115mm thicks, laid and jointed in

    CM 1:4, straight or to curve with inner radious of 6m and over, upto 4.25m depth,

    including racking out the joints where necessary scaffolding & curing etc. Complete

    in all respect as per specification and instruction if Engineer incharge.

    Cft 242.440

    8 11-09-b

    P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand mortar includind

    scafolding, chambering of edges, rounding the corners , making groves and edges

    where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12" wide at all joints

    of R.C.C and brick work, curing, cleaning, complete in all respect, specifications and

    instructions of engineer incharge.

    Sft 735.000

    913-30-a + 2 x 13-

    30-b

    Surface prepartion (for dempenss) by provission of film with Alkali resisting primer

    on plaster wall and ceilling . Including first coat of painting new or old work such

    as walls including all detacheched attachement with plast emulsion paint.

    Including subsequent tywo coats of emulsion paints.

    Sft 735.000

    10 10-03-aProvding sand cushion in lyers as specified under concreet, road, hard standing and

    landing including dressing, leveling, compacting and consolidating as per

    specification and instruction of the Engineer Inchage.

    Cft 160.000

    11 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft 52.800

    12 10-48-aProvding and laying porceline tile floor 1/4 inch thick laid cement 1:2 or 3/4 inch

    thick cement mortar 1:2 (local master tiles)Sft 160.000

    13 24-16-c-08 Extra for providing /fixing approved quality rim locks : local Rft 36.000

    14 NSI P/L, cut, joint, test and disinfect MS pipe 1.5" X 2" Rft 100.000

    15 9--13--C S/F corrugated GI sheet with GI bolt,nuts,limpite 24 BWG Sft 216.000

    16 06-05-hP/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone aggregate i/c form-

    work, placing, compacting, leveling and curing etc. Complete as per specification

    and instructions of Engineer incharge.

    Cft 34.980

    17 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC insulated Each 1.000

    1815-05-e

    Supply and Erection 7/.044" single core Copper PVC insulated 250/440 voltage

    grade cable.Rft 75.000

    19 15-81 Supply and fixing 20 ampere power pluge Each 1.000

    20 15-78 Supply and Fixing bracket fan pak made complete Each 2.000

    2115-61-a

    Supply and Erection fluorescent tube light fitting including 4' rod, choke, starter,

    flexible wire etc : SingleEach 2.000

    22 NSI Benches for Patients. No 2.000

    S.NO MRS-2017 Description Unit Quantity

    1 03-23-b Excavation in foundation of building, bridges etc complete in ordinary soil Cft 2174.000

    Civil Works Kohat BHU Parshai

    Page 6 of 35

  • 2 26-15 Spraying anti-termite liquid mixed with water in ration of 1:40 Sft 1000.000

    3 06-05-i

    P/L: P.C.C 1:4:8 in any part of building such as foundation, etc. using 1½" down

    graded stone aggregate i/c form-work, placing, compacting, leveling and curing

    etc. Complete as per specification and instructions of Engineer incharge.

    Cft 343.338

    4 06-06-a-03

    P/L: RCC 1:2:4 i/c using approved quality of crushed stones and fine agregate

    (sand) in roof slab, landing, wall, plienth beam & bands including mixing in

    concrete mixer, lifting, placing in steel fom work, vibrating, consolidating, dressing,

    levling and curing excluding the cost of re-inforcement bars and the cost of laborty

    quality test. Complete in all respect as per specification and instruction of Engineer

    incharge.

    Cft 1352.720

    5 06-07-c

    PF in position mild reinforcement defomed bars (40000 psi yield strength) of any

    size and diameter including straightening , bending, placing, binding in position

    with binding wire, placing spacers. Complete in all respects as per specification and

    instruction of Engineer incharge.

    M.Ton 5.438

    6 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat , one layer polythene and

    one coat bitumen ( 2" thick)Sft 147.225

    7 07-04-a-03

    P/L: 1st class approved solid BB masonry in walls over 115mm thicks, laid and

    jointed in CM 1:4, straight or to corve with inner radious of 6m and over, upto

    4.25m depth, including racking out the joints where necessary scaffolding & curing

    etc. Complete in all respect as per specification and instruction if Engineer

    incharge.

    Cft 569.625

    8 07-05-a-03

    P/L: 1st class approved solid BB masonry in walls 115mm thicks, laid and jointed in

    CM 1:4, straight or to curve with inner radious of 6m and over, upto 4.25m depth,

    including racking out the joints where necessary scaffolding & curing etc. Complete

    in all respect as per specification and instruction if Engineer incharge.

    Cft 1126.922

    9 11-09-b

    P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand mortar includind

    scafolding, chambering of edges, rounding the corners , making groves and edges

    where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12" wide at all joints

    of R.C.C and brick work, curing, cleaning, complete in all respect, specifications and

    instructions of engineer incharge.

    Sft 5023.969

    1013-30-a + 2 x 13-

    30-b

    Surface prepartion (for dempenss) by provission of film with Alkali resisting primer

    on plaster wall and ceilling . Including first coat of painting new or old work such

    as walls including all detacheched attachement with plast emulsion paint.

    Including subsequent tywo coats of emulsion paints.

    Sft 5023.969

    11 10-03-a

    Provding sand cushion in lyers as specified under concreet, road, hard standing and

    landing including dressing, leveling, compacting and consolidating as per

    specification and instruction of the Engineer Inchage.

    Cft 540.813

    12 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft 245.149

    13 10-48-aProvding and laying porceline tile floor 1/4 inch thick laid cement 1:2 or 3/4 inch

    thick cement mortar 1:2 (local master tiles)Sft 1435.938

    Page 7 of 35

  • 14 12-07-aFirst class doadar wood wrought joinery in doors and window etc complete : 2 inch

    thickSft 105.000

    15 12-20-a-02 Extra for providing /fixing approved quality rim locks : local Nos 4.000

    16 12-56-a

    Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type chowkat including

    fixing and position with all charges for hold fast hinges and paint etc complete in

    all respect as per drawings and as per specification as directed by engineer

    incharge

    Rft 151.000

    17 25-39-b-03

    Providing and fixing steel window 18 gauge with openable glazed panels with 22

    SWG wire gauze glass pane 3 mm including grill complete in all respect as per

    drawings and specification and as per directed by the engineer incharge

    Sft 111.000

    18 12-49Curtain railing to doors and windows comprising toso-elite japanees railing or

    equivalent inclunding paintRft 18.000

    19 NSI Provision and fixing of blind to windows as per direction of engineer incharge Sft 144.000

    20 24-17-a-01

    Supply and fixing of aproved AC building pipe Class , 80mm with pigot and socket

    joints and hexagonal head for rain water including jointing and suport MS Plate

    19mm x 6mm @ 1m apart. Complet in all respect and in accordance with

    specification and instruction of the Engineer Incharge.

    Rft 26.000

    21 09--05

    Supply and fixing of one lyer of brick tile (300mm x 150mm) x 50mm flat brick on

    roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage), one coat of hot

    bitumen (10 - 15 grade) and one lyer of approve polythene sheet. Complet in all

    respect and in accordance with specification and instruction of the Engineer

    Incharge.

    Sft 1120.000

    22 06-05-h

    P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone aggregate i/c

    form-work, placing, compacting, leveling and curing etc. Complete as per

    specification and instructions of Engineer incharge.

    Cft 43.560

    S.NO MRS-2017 Description Unit Quantity

    IE-1 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC insulated Each 16.000

    IE-2 15-05-eSupply and Erection 7/.044" single core Copper PVC insulated 250/440 voltage

    grade cable.Rft 400.000

    IE-3 15-81 Supply and fixing 20 ampere power pluge Each 4.000

    IE-4 15-82 Supply and fixing 30 ampere power pluge Each 8.000

    IE-5 15-83 Supply and fixing 10 ampere power pluge Each 6.000

    IE-6 15-68-cSupply and Erection best quality AC ceiling fan completewith GI rod, canopy,

    blades & regulator : 56" sweepEach 4.000

    IE-7 NSI

    Supply & Installation of 12" sweep, plastic body, Exhaust fan including all civil

    works required for complete installation and of Asia/Climax/Pak fan made

    including all labour and materials cable as required at site and as approved by the

    Engineer Incharge. (Exaust fan will be fitted in proper steel frame along with wire

    gauze at external side)

    Each 4.000

    Internal Electrification works Kohat BHU Parshai

    Page 8 of 35

  • IE-8 15-25 Supply and Erection girder clamp hook, 5/8" dia.for hanging ceiling fan Each 6.000

    IE-9 15-61-aSupply and Erection fluorescent tube light fitting including 4' rod, choke, starter,

    flexible wire etc : SingleEach 14.000

    IE-10 15-53Special Earthing of iron/metal clad switches etc with copper wire No. 8 SWG in GI

    pipe 1/2" diaEach 1.000

    E-11

    15-71-d Supply and Erection single phase imported auto circuit breaker 30 Amp. Each 4.000

    15-71-a Supply and Erection single phase imported auto circuit breaker 6 Amp Each 14.000

    15-71-b Supply and Erection single phase imported auto circuit breaker 15 Amp Each 12.000

    NSISupply and Erection Cubical Type Factory Fabricated floor/wall mounting steel

    main board comp. : RecessedNo 1.000

    IE-9 NSIProviding and fixing of distribution board along with best quality electric button

    and dimmer complete with all accesoories as recommended by the Engineer

    Incharge (Labour room and recovery room)

    No 2.000

    NSIProviding and fixing of distribution board along with best quality electric button

    and dimmer complete with all accesoories as recommended by the Engineer

    Incharge (Wash Room and Verandah)

    No 2.000

    Sub Head MRS-2017 Description Unit Quantity

    Sanitary 14-01-a

    P/F: European type WC (ICI Boch or equivalent) i/c flush Tanki, P/Trap, Stop Cock,

    Plastic Connection etc. Complete as per specification and instruction of Engineer

    Incharge(Porta , Duur or equivalent )

    Each 5.000

    14-05-b-01 Providing and fixing glazed earthen WHB complte with pedistal white size 25" x 18" Each 3.000

    14-27 Providing and fixing CP mixing valve for WHB/SHOWER Each 3.000

    14-24-b Providing and Fixing CP bib-cock, heavy type : 1/2" Each 10.000

    14-17P/F: of 22"x16"best quality 5mm mirror glass of approved quality. Complete in all

    respect as per specification and instruction of Engineer incharge. Each 3.000

    14.20 cP/F: best quality towel rail of approved quality as per specification and instruction

    of engineer incharge Each 3.000

    14.20 bP/F: best quality paper holder of approved quality as per specification and

    instruction of engineer inchargeEach 5.000

    14.20 aP/F: best quality plastic soap dish of approved quality as per specification and

    instruction of engineer incharge Each 3.000

    14-28-a Providing and Fixing gun metal peet / gate valve (screwed) 1" dia Each 6.000

    14-31-bProviding and Fixing CI floor trap including CI grating & concrete chamber all round

    : 4"x3"Each 2.000

    Water supply 14-55-e Providing and Fixing GI pipe & including specials complete 3/4" dia (light) RFt 800.000

    14-55-f Providing and Fixing GI pipe & including specials complete 1/2" dia (light) RFt 500.000

    14-69-b-03 P/F Fibre Glass Water Tank 500 gallons Each 3.000

    Sewerage 14-70-aProviding and Fixing of pipe type B nikasi system including testing in all respect 110

    mm (using dadex, or eq)Rft 195.000

    Distribution Board:

    Water Supply and Sanitation Works Kohat BHU Parshai

    Page 9 of 35

  • NSIProviding and Fixing of pipe type wind pipe system including testing in all respect

    of 2 inch with capRft 110.000

    14-37-c Supply and Fixing CI manhole cover with frame etc complete 25" dia Each 7.000

    23-10 Construction of septic tank (7' x 2' x 5') complete in all respect) Each 2.000

    23-11Construction of Soakage pit having 6 Rft dia and 10 Rft deep filled with brick and

    brick linning at sideEach 2.000

    NSI

    Construction of manholes 2'X2' in size including excavation, backfilling, 9" thick

    brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick cement sand plaster

    complete.

    Each 8.000

    S No. MRS Code 2017 Description Units Nos Length WidthHeight/Dep

    th

    Total

    Quantities1 04-48-b Remove of extra material from roof Sft 1.000 42.000 21.000 882.000

    2 10-15-e PCC (1:2:4) as screeding 2" thick Sft 1.000 42.000 21.000 882.000

    3 11-09-b Cement sand mortor on walls in 1:4 CSM Sft 1.000 1480.000

    4 10-15-eProvide & lay topping of concrete 1:2:4, including surface finishing & dividing in

    panels : 2" thickSft 2.000 12.000 15.000 180.000

    5 10-15-eProvide & lay topping of concrete 1:2:4, including surface finishing & dividing in

    panels : 2" thickSft 2.000 11.000 12.000 132.000

    6 13-05-c-01 & 02Painting old surfaces : Doors / windows any type First coat & one another coat. In

    3 quarters and their boundary wallsSft 2.000 6.000 10.000 1200.000

    7 04-24Repairing and fixing of old wooden door in pannels with chowkat, locks and polish

    in wooden color completeSft 6.000 7.000 3.000 126.000

    8 NSIRepair of external MS Grill repair with welding & replacement of broken/rusted

    portions complete & prepared for paint jobSft 4.000 6.000 4.000 96.000

    9 12-51Provide & fix GI wire gauze 22 SWG, 12x12 mesh per sq. in, fixed to steel window

    completeSft 4.000 6.000 4.000 96.000

    10 06-05-f PCC 1:2:4 in the open space of the BHU Cft 2.000 22.000 15.000 0.333 219.780

    11 13-05-c-01 & 02Painting old surfaces : Doors / windows any type First coat & one another coat. In

    3 quarters and their boundary wallsSft 3.000 340.000 10.000 1500.000

    12 14-69-a-03 P/F Fibre Glass Water Tank 500 gallons Each 1.000 1.000 1.000

    13 14-03-aProviding and Fixing glazed earthen ware WC squatting type with built-in foot rests

    : WhiteNo 2.000 2.000 4.000

    14 14-05-a-02 Providing and Fixing glazed earthen ware WHB complete No 2.000 4.000 8.000

    15 14-31-b Floor Trap complete with fitting No 2.000 2.000 4.000

    16 23-02-a Providing and Laying non-reinforced concrete pipe Rft 2.000 80.000 160.000

    17 14-81-aSupply and fixing of 3.0 HP Monoblock water pump 1.5"x1.5" size 5 stage DE-S5

    model single phase for 220 ft head with all accessories.No 1.000 1.000 1.000

    18 24-02-d-01Tubewell boring in all soils except shingle/rock From 300'

    to 400' below ground : 8" i/dNo 1.000 150.000 150.000

    19 24-12-c-01Providing and installing PVC blind pipe in tubewell with

    strainer BSS Class 'D' working pressure : 6" i/dRft 1.000 -38.000 -38.000

    Rehabilitation Works Kohat BHU Parshai

    Page 10 of 35

  • 20 24-09-c-0Providing and installing PVC strainer, in tubewell

    borehole comp. BSS Class 'D' working pressure : 6" i/dRft 1.000 39.000 39.000

    21 24-14Shrouding with graded pack grave 3/8" to 1/8" around

    tubewell in bore holeCft 1.000 60.000 60.000

    22 24-30-a-01Providing and Laying HDPE pipe Din-/Din-/ISO-4427

    incl testing & disinfect complete (20mm diaRft 1.000 160.000 160.000

    23 24-16-c-02Providing and Laying cut, joint, test & disinfect GI pipe

    line Using light quality GI Pipe : 3/4" i/d Rft 1.000 90.000 90.000

    24 11-09-b Plaster on the walls in 1:4 CSM Cft 1.000 200.000 0.750 3.000 450.000

    25 NSI

    Construction of manholes 2'X2' in size including excavation, backfilling, 9" thick

    brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick cement sand plaster

    complete.

    No 8.000 8.000

    S.NO MRS-2017 Description Unit Quantity

    1 03-23-b Excavation in foundation of building, bridges etc complete in ordinary soil Cft 376.000

    2 06-05-i

    P/L: P.C.C 1:4:8 in any part of building such as foundation, etc. using 1½" down

    graded stone aggregate i/c form-work, placing, compacting, leveling and curing

    etc. Complete as per specification and instructions of Engineer incharge.Cft 62.000

    3 06-06-a-03

    P/L: RCC 1:2:4 i/c using approved quality of crushed stones and fine agregate

    (sand) in roof slab, landing, wall, plienth beam & bands including mixing in

    concrete mixer, lifting, placing in steel fom work, vibrating, consolidating, dressing,

    levling and curing excluding the cost of re-inforcement bars and the cost of laborty

    quality test. Complete in all respect as per specification and instruction of Engineer

    incharge.

    Cft 86.760

    4 06-07-c

    PF in position mild reinforcement defomed bars (40000 psi yield strenght) of any

    size and dimetter including straightening , bending, placeing, binding in position

    with binding wire, placing spacesers. Complete in all respects as per specification

    and instruction of Engineer incharge.

    M.Ton 0.350

    5 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat, one layer polythene and

    one coat bitumen ( 2" thick)Sft 39.550

    6 07-04-a-03

    P/L: 1st class approved solid BB masonry in walls over 115mm thicks, laid and

    jointed in CM 1:4, straight or to corve with inner radious of 6m and over, upto

    4.25m depth, including racking out the joints where necessary scaffolding & curing

    etc. Complete in all respect as per specification and instruction if Engineer

    incharge.

    Cft 164.500

    7 07-05-a-03

    P/L: 1st class approved solid BB masonry in walls 115mm thicks, laid and jointed in

    CM 1:4, straight or to curve with inner radious of 6m and over, upto 4.25m depth,

    including racking out the joints where necessary scaffolding & curing etc. Complete

    in all respect as per specification and instruction if Engineer incharge.

    Cft 242.440

    Waiting Shed Kohat BHU Parshai

    Page 11 of 35

  • 8 11-09-b

    P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand mortar includind

    scafolding, chambering of edges, rounding the corners , making groves and edges

    where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12" wide at all joints

    of R.C.C and brick work, curing, cleaning, complete in all respect, specifications and

    instructions of engineer incharge.

    Sft 735.000

    913-30-a + 2 x 13-

    30-b

    Surface prepartion (for dempenss) by provission of film with Alkali resisting primer

    on plaster wall and ceilling . Including first coat of painting new or old work such

    as walls including all detacheched attachement with plast emulsion paint.

    Including subsequent tywo coats of emulsion paints.

    Sft 735.000

    10 10-03-aProvding sand cushion in lyers as specified under concreet, road, hard standing and

    landing including dressing, leveling, compacting and consolidating as per

    specification and instruction of the Engineer Inchage.

    Cft 160.000

    11 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft 52.800

    12 10-48-aProvding and laying porceline tile floor 1/4 inch thick laid cement 1:2 or 3/4 inch

    thick cement mortar 1:2 (local master tiles)Sft 160.000

    13 24-16-c-08 Extra for providing /fixing approved quality rim locks : local Rft 36.000

    14 NSI P/L, cut, joint, test and disinfect MS pipe 1.5" X 2" Rft 100.000

    15 9--13--C S/F corrugated GI sheet with GI bolt,nuts,limpite 24 BWG Sft 216.000

    16 06-05-hP/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone aggregate i/c form-

    work, placing, compacting, leveling and curing etc. Complete as per specification

    and instructions of Engineer incharge.

    Cft 34.980

    17 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC insulated Each 1.000

    1815-05-e

    Supply and Erection 7/.044" single core Copper PVC insulated 250/440 voltage

    grade cable.Rft 75.000

    19 15-81 Supply and fixing 20 ampere power pluge Each 1.000

    20 15-78 Supply and Fixing bracket fan pak made complete Each 2.000

    2115-61-a

    Supply and Erection fluorescent tube light fitting including 4' rod, choke, starter,

    flexible wire etc : SingleEach 2.000

    22 NSI Benches for Patients. No 2.000

    S.NO MRS-2017 Description Unit Quantity

    1 03-23-b Excavation in foundation of building, bridges etc complete in ordinary soil Cft 2174.000

    2 26-15 Spraying anti-termite liquid mixed with water in ration of 1:40 Sft 1000.000

    3 06-05-i

    P/L: P.C.C 1:4:8 in any part of building such as foundation, etc. using 1½" down

    graded stone aggregate i/c form-work, placing, compacting, leveling and curing

    etc. Complete as per specification and instructions of Engineer incharge.

    Cft 343.338

    Civil Works Kohat BHU Togh Bala

    Page 12 of 35

  • 4 06-06-a-03

    P/L: RCC 1:2:4 i/c using approved quality of crushed stones and fine agregate

    (sand) in roof slab, landing, wall, plienth beam & bands including mixing in

    concrete mixer, lifting, placing in steel fom work, vibrating, consolidating, dressing,

    levling and curing excluding the cost of re-inforcement bars and the cost of laborty

    quality test. Complete in all respect as per specification and instruction of Engineer

    incharge.

    Cft 1352.720

    5 06-07-c

    PF in position mild reinforcement defomed bars (40000 psi yield strength) of any

    size and diameter including straightening , bending, placing, binding in position

    with binding wire, placing spacers. Complete in all respects as per specification and

    instruction of Engineer incharge.

    M.Ton 5.438

    6 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat , one layer polythene and

    one coat bitumen ( 2" thick)Sft 147.225

    7 07-04-a-03

    P/L: 1st class approved solid BB masonry in walls over 115mm thicks, laid and

    jointed in CM 1:4, straight or to corve with inner radious of 6m and over, upto

    4.25m depth, including racking out the joints where necessary scaffolding & curing

    etc. Complete in all respect as per specification and instruction if Engineer

    incharge.

    Cft 569.625

    8 07-05-a-03

    P/L: 1st class approved solid BB masonry in walls 115mm thicks, laid and jointed in

    CM 1:4, straight or to curve with inner radious of 6m and over, upto 4.25m depth,

    including racking out the joints where necessary scaffolding & curing etc. Complete

    in all respect as per specification and instruction if Engineer incharge.

    Cft 1126.922

    9 11-09-b

    P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand mortar includind

    scafolding, chambering of edges, rounding the corners , making groves and edges

    where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12" wide at all joints

    of R.C.C and brick work, curing, cleaning, complete in all respect, specifications and

    instructions of engineer incharge.

    Sft 5023.969

    1013-30-a + 2 x 13-

    30-b

    Surface prepartion (for dempenss) by provission of film with Alkali resisting primer

    on plaster wall and ceilling . Including first coat of painting new or old work such

    as walls including all detacheched attachement with plast emulsion paint.

    Including subsequent tywo coats of emulsion paints.

    Sft 5023.969

    11 10-03-a

    Provding sand cushion in lyers as specified under concreet, road, hard standing and

    landing including dressing, leveling, compacting and consolidating as per

    specification and instruction of the Engineer Inchage.

    Cft 540.813

    12 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft 245.149

    13 10-48-aProvding and laying porceline tile floor 1/4 inch thick laid cement 1:2 or 3/4 inch

    thick cement mortar 1:2 (local master tiles)Sft 1435.938

    14 12-07-aFirst class doadar wood wrought joinery in doors and window etc complete : 2 inch

    thickSft 105.000

    15 12-20-a-02 Extra for providing /fixing approved quality rim locks : local Nos 4.000

    Page 13 of 35

  • 16 12-56-a

    Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type chowkat including

    fixing and position with all charges for hold fast hinges and paint etc complete in

    all respect as per drawings and as per specification as directed by engineer

    incharge

    Rft 151.000

    17 25-39-b-03

    Providing and fixing steel window 18 gauge with openable glazed panels with 22

    SWG wire gauze glass pane 3 mm including grill complete in all respect as per

    drawings and specification and as per directed by the engineer incharge

    Sft 111.000

    18 12-49Curtain railing to doors and windows comprising toso-elite japanees railing or

    equivalent inclunding paintRft 18.000

    19 NSI Provision and fixing of blind to windows as per direction of engineer incharge Sft 144.000

    20 24-17-a-01

    Supply and fixing of aproved AC building pipe Class , 80mm with pigot and socket

    joints and hexagonal head for rain water including jointing and suport MS Plate

    19mm x 6mm @ 1m apart. Complet in all respect and in accordance with

    specification and instruction of the Engineer Incharge.

    Rft 26.000

    21 09--05

    Supply and fixing of one lyer of brick tile (300mm x 150mm) x 50mm flat brick on

    roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage), one coat of hot

    bitumen (10 - 15 grade) and one lyer of approve polythene sheet. Complet in all

    respect and in accordance with specification and instruction of the Engineer

    Incharge.

    Sft 1120.000

    22 06-05-h

    P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone aggregate i/c

    form-work, placing, compacting, leveling and curing etc. Complete as per

    specification and instructions of Engineer incharge.

    Cft 43.560

    S.NO MRS-2017 Description Unit Quantity

    IE-1 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC insulated Each 16.000

    IE-2 15-05-eSupply and Erection 7/.044" single core Copper PVC insulated 250/440 voltage

    grade cable.Rft 400.000

    IE-3 15-81 Supply and fixing 20 ampere power pluge Each 4.000

    IE-4 15-82 Supply and fixing 30 ampere power pluge Each 8.000

    IE-5 15-83 Supply and fixing 10 ampere power pluge Each 6.000

    IE-6 15-68-cSupply and Erection best quality AC ceiling fan completewith GI rod, canopy,

    blades & regulator : 56" sweepEach 4.000

    IE-7 NSI

    Supply & Installation of 12" sweep, plastic body, Exhaust fan including all civil

    works required for complete installation and of Asia/Climax/Pak fan made

    including all labour and materials cable as required at site and as approved by the

    Engineer Incharge. (Exaust fan will be fitted in proper steel frame along with wire

    gauze at external side)

    Each 4.000

    IE-8 15-25 Supply and Erection girder clamp hook, 5/8" dia.for hanging ceiling fan Each 6.000

    IE-9 15-61-aSupply and Erection fluorescent tube light fitting including 4' rod, choke, starter,

    flexible wire etc : SingleEach 10.000

    Internal Electrification works Kohat BHU Togh Bala

    Page 14 of 35

  • IE-10 15-53Special Earthing of iron/metal clad switches etc with copper wire No. 8 SWG in GI

    pipe 1/2" diaEach 1.000

    E-11

    15-71-d Supply and Erection single phase imported auto circuit breaker 30 Amp. Each 4.000

    15-71-a Supply and Erection single phase imported auto circuit breaker 6 Amp Each 14.000

    15-71-b Supply and Erection single phase imported auto circuit breaker 15 Amp Each 12.000

    NSISupply and Erection Cubical Type Factory Fabricated floor/wall mounting steel

    main board comp. : RecessedNo 1.000

    IE-9 NSIProviding and fixing of distribution board along with best quality electric button

    and dimmer complete with all accesoories as recommended by the Engineer

    Incharge (Labour room and recovery room)

    No 2.000

    NSIProviding and fixing of distribution board along with best quality electric button

    and dimmer complete with all accesoories as recommended by the Engineer

    Incharge (Wash Room and Verandah)

    No 2.000

    Sub Head MRS-2017 Description Unit Quantity

    Sanitary 14-01-a

    P/F: European type WC (ICI Boch or equivalent) i/c flush Tanki, P/Trap, Stop Cock,

    Plastic Connection etc. Complete as per specification and instruction of Engineer

    Incharge(Porta , Duur or equivalent )

    Each 5.000

    14-05-b-01 Providing and fixing glazed earthen WHB complte with pedistal white size 25" x 18" Each 3.000

    14-27 Providing and fixing CP mixing valve for WHB/SHOWER Each 3.000

    14-24-b Providing and Fixing CP bib-cock, heavy type : 1/2" Each 10.000

    14-17P/F: of 22"x16"best quality 5mm mirror glass of approved quality. Complete in all

    respect as per specification and instruction of Engineer incharge. Each 3.000

    14.20 cP/F: best quality towel rail of approved quality as per specification and instruction

    of engineer incharge Each 3.000

    14.20 bP/F: best quality paper holder of approved quality as per specification and

    instruction of engineer inchargeEach 5.000

    14.20 aP/F: best quality plastic soap dish of approved quality as per specification and

    instruction of engineer incharge Each 3.000

    14-28-a Providing and Fixing gun metal peet / gate valve (screwed) 1" dia Each 6.000

    14-31-bProviding and Fixing CI floor trap including CI grating & concrete chamber all round

    : 4"x3"Each 2.000

    Water supply 14-55-e Providing and Fixing GI pipe & including specials complete 3/4" dia (light) RFt 800.000

    14-55-f Providing and Fixing GI pipe & including specials complete 1/2" dia (light) RFt 500.000

    14-69-b-03 P/F Fibre Glass Water Tank 500 gallons Each 3.000

    Sewerage 14-70-aProviding and Fixing of pipe type B nikasi system including testing in all respect 110

    mm (using dadex, or eq)Rft 195.000

    NSIProviding and Fixing of pipe type wind pipe system including testing in all respect

    of 2 inch with capRft 110.000

    14-37-c Supply and Fixing CI manhole cover with frame etc complete 25" dia Each 7.000

    Distribution Board:

    Water Supply and Sanitation Works Kohat BHU Togh Bala

    Page 15 of 35

  • 23-10 Construction of septic tank (7' x 2' x 5') complete in all respect) Each 2.000

    23-11Construction of Soakage pit having 6 Rft dia and 10 Rft deep filled with brick and

    brick linning at sideEach 2.000

    NSI

    Construction of manholes 2'X2' in size including excavation, backfilling, 9" thick

    brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick cement sand plaster

    complete.

    Each 8.000

    S No. MRS Code 2017 Description Units Nos Length WidthHeight/Dep

    th

    Total

    Quantities

    1 13-05-c-01 & 02Painting old surfaces : Doors / windows any type First coat & one another coat. In

    3 quarters and their boundary wallsSft 1.000 1800.000

    2 12-51Provide & fix GI wire gauze 22 SWG, 12x12 mesh per sq. in, fixed to steel window

    completeSft 4.000 6.000 4.000 96.000

    3 06-05-f PCC 1:2:4 in the open space of the BHU Cft 2.000 22.000 15.000 0.333 219.780

    4 15-02-a-06Supply and Erection PVC pipe for wiring purpose complete On surface including

    clamps etc: 2" i/dRft 2.000 250.000 500.000

    5 15-05-aSupply and Erection single core PVC insulated copper conductor 3/29 V grade

    cableRft 2.000 500.000 1000.000

    6 15-05-fSupply and Erection single core PVC insulated copper conductor 250/440 V grade

    cable : 7/0.064"Rft 2.000 100.000 200.000

    7 15-18-a Supply and Erection switches 10/15 Amp : Open type Each 2.000 4.000 8.000

    8 15-80 Supply and Fixing dimmer switch complete Each 2.000 3.000 6.000

    9 15-68-cSupply and Erection best quality AC ceiling fan completewith GI rod, canopy,

    blades & regulator : 56" sweepEach 4.000

    S.NO MRS-2017 Description Unit Quantity

    1 03-23-b Excavation in foundation of building, bridges etc complete in ordinary soil Cft 376.000

    2 06-05-i

    P/L: P.C.C 1:4:8 in any part of building such as foundation, etc. using 1½" down

    graded stone aggregate i/c form-work, placing, compacting, leveling and curing

    etc. Complete as per specification and instructions of Engineer incharge.Cft 62.000

    3 06-06-a-03

    P/L: RCC 1:2:4 i/c using approved quality of crushed stones and fine agregate

    (sand) in roof slab, landing, wall, plienth beam & bands including mixing in

    concrete mixer, lifting, placing in steel fom work, vibrating, consolidating, dressing,

    levling and curing excluding the cost of re-inforcement bars and the cost of laborty

    quality test. Complete in all respect as per specification and instruction of Engineer

    incharge.

    Cft 86.760

    4 06-07-c

    PF in position mild reinforcement defomed bars (40000 psi yield strenght) of any

    size and dimetter including straightening , bending, placeing, binding in position

    with binding wire, placing spacesers. Complete in all respects as per specification

    and instruction of Engineer incharge.

    M.Ton 0.350

    Rehabilitation Works Kohat BHU Togh Bala

    Waiting Shed Kohat BHU Togh Bala

    Page 16 of 35

  • 5 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat, one layer polythene and

    one coat bitumen ( 2" thick)Sft 39.550

    6 07-04-a-03

    P/L: 1st class approved solid BB masonry in walls over 115mm thicks, laid and

    jointed in CM 1:4, straight or to corve with inner radious of 6m and over, upto

    4.25m depth, including racking out the joints where necessary scaffolding & curing

    etc. Complete in all respect as per specification and instruction if Engineer

    incharge.

    Cft 164.500

    7 07-05-a-03

    P/L: 1st class approved solid BB masonry in walls 115mm thicks, laid and jointed in

    CM 1:4, straight or to curve with inner radious of 6m and over, upto 4.25m depth,

    including racking out the joints where necessary scaffolding & curing etc. Complete

    in all respect as per specification and instruction if Engineer incharge.

    Cft 242.440

    8 11-09-b

    P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand mortar includind

    scafolding, chambering of edges, rounding the corners , making groves and edges

    where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12" wide at all joints

    of R.C.C and brick work, curing, cleaning, complete in all respect, specifications and

    instructions of engineer incharge.

    Sft 735.000

    913-30-a + 2 x 13-

    30-b

    Surface prepartion (for dempenss) by provission of film with Alkali resisting primer

    on plaster wall and ceilling . Including first coat of painting new or old work such

    as walls including all detacheched attachement with plast emulsion paint.

    Including subsequent tywo coats of emulsion paints.

    Sft 735.000

    10 10-03-aProvding sand cushion in lyers as specified under concreet, road, hard standing and

    landing including dressing, leveling, compacting and consolidating as per

    specification and instruction of the Engineer Inchage.

    Cft 160.000

    11 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft 52.800

    12 10-48-aProvding and laying porceline tile floor 1/4 inch thick laid cement 1:2 or 3/4 inch

    thick cement mortar 1:2 (local master tiles)Sft 160.000

    13 24-16-c-08 Extra for providing /fixing approved quality rim locks : local Rft 36.000

    14 NSI P/L, cut, joint, test and disinfect MS pipe 1.5" X 2" Rft 100.000

    15 9--13--C S/F corrugated GI sheet with GI bolt,nuts,limpite 24 BWG Sft 216.000

    16 06-05-hP/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone aggregate i/c form-

    work, placing, compacting, leveling and curing etc. Complete as per specification

    and instructions of Engineer incharge.

    Cft 34.980

    17 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC insulated Each 1.000

    1815-05-e

    Supply and Erection 7/.044" single core Copper PVC insulated 250/440 voltage

    grade cable.Rft 75.000

    19 15-81 Supply and fixing 20 ampere power pluge Each 1.000

    20 15-78 Supply and Fixing bracket fan pak made complete Each 2.000

    2115-61-a

    Supply and Erection fluorescent tube light fitting including 4' rod, choke, starter,

    flexible wire etc : SingleEach 2.000

    22 NSI Benches for Patients. No 2.000

    Civil Works Kohat BHU Bazid Khel

    Page 17 of 35

  • S.NO MRS-2017 Description Unit Quantity

    1 03-23-b Excavation in foundation of building, bridges etc complete in ordinary soil Cft 2174.000

    2 26-15 Spraying anti-termite liquid mixed with water in ration of 1:40 Sft 1000.000

    3 06-05-i

    P/L: P.C.C 1:4:8 in any part of building such as foundation, etc. using 1½" down

    graded stone aggregate i/c form-work, placing, compacting, leveling and curing

    etc. Complete as per specification and instructions of Engineer incharge.

    Cft 343.338

    4 06-06-a-03

    P/L: RCC 1:2:4 i/c using approved quality of crushed stones and fine agregate

    (sand) in roof slab, landing, wall, plienth beam & bands including mixing in

    concrete mixer, lifting, placing in steel fom work, vibrating, consolidating, dressing,

    levling and curing excluding the cost of re-inforcement bars and the cost of laborty

    quality test. Complete in all respect as per specification and instruction of Engineer

    icharge.

    Cft 1352.720

    06-07-c

    PF in position mild reinforcement defomed bars (40000 psi yield strenght) of any

    size and dimetter including straightening , bending, placeing, binding in position

    with binding wire, placing spacesers. Complete in all respects as per specification

    and instruction of Engineer incharge.

    M.Ton 5.438

    5 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat , one layer polythene and

    one coat bitumen ( 2" thick)Sft 147.225

    6 07-04-a-03

    P/L: 1st class approved solid BB masonry in walls over 115mm thicks, laid and

    jointed in CM 1:4, straight or to corve with inner radious of 6m and over, upto

    4.25m depth, including racking out the joints where necessary scaffolding & curing

    etc. Complete in all respect as per specification and instruction if Engineer

    incharge.

    Cft 569.625

    7 07-05-a-03

    P/L: 1st class approved solid BB masonry in walls 115mm thicks, laid and jointed in

    CM 1:4, straight or to curve with inner radious of 6m and over, upto 4.25m depth,

    including racking out the joints where necessary scaffolding & curing etc. Complete

    in all respect as per specification and instruction if Engineer incharge.

    Cft 1126.922

    8 11-09-b

    P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand mortar includind

    scafolding, chambering of edges, rounding the corners , making groves and edges

    where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12" wide at all joints

    of R.C.C and brick work, curing, cleaning, complete in all respect, specifications and

    instructions of engineer incharge.

    Sft 5023.969

    9 13-30-a + 2 x 13-30-b

    Surface prepartion (for dempenss) by provission of film with Alkali resisting primer

    on plaster wall and ceilling . Including first coat of painting new or old work such

    as walls including all detacheched attachement with plast emulsion paint.

    Including subsequent tywo coats of emulsion paints.

    Sft 5023.969

    10 10-03-a

    Provding sand cushion in lyers as specified under concreet, road, hard standing and

    landing including dressing, leveling, compacting and consolidating as per

    specification and instruction of the Engineer Inchage.

    Cft 540.813

    11 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft 245.149

    Page 18 of 35

  • 12 10-48-aProvding and laying porceline tile floor 1/4 inch thick laid cement 1:2 or 3/4 inch

    thick cement mortar 1:2 (local master tiles)Sft 1435.938

    13 12-07-aFirst class doadar wood wrought joinery in doors and window etc complete : 2 inch

    thickSft 105.000

    14 12-20-a-02 Extra for providing /fixing approved quality rim locks : local Nos 4.000

    15 12-56-a

    Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type chowkat including

    fixing and position with all charges for hold fast hinges and paint etc complete in

    all respect as per drawings and as per specification as directed by engineer

    incharge

    Rft 151.000

    16 25-39-b-03

    Providing and fixing steel window 18 gauge with openable glazed panels with 22

    SWG wire gauze glass pane 3 mm including grill complete in all respect as per

    drawings and specification and as per directed by the engineer incharge

    Sft 111.000

    17 12-49Curtain railing to doors and windows comprising toso-elite japanees railing or

    equivalent inclunding paintRft 18.000

    18 NSI Provision and fixing of blind to windows as per direction of engineer incharge Sft 144.000

    19 24-17-a-01

    Supply and fixing of aproved AC building pipe Class , 80mm with pigot and socket

    joints and hexagonal head for rain water including jointing and suport MS Plate

    19mm x 6mm @ 1m apart. Complet in all respect and in accordance with

    specification and instruction of the Engineer Incharge.

    Rft 26.000

    20 09--05

    Supply and fixing of one lyer of brick tile (300mm x 150mm) x 50mm flat brick on

    roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage), one coat of hot

    bitumen (10 - 15 grade) and one lyer of approve polythene sheet. Complet in all

    respect and in accordance with specification and instruction of the Engineer

    Incharge.

    Sft 1120.000

    21 06-05-h

    P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone aggregate i/c

    form-work, placing, compacting, leveling and curing etc. Complete as per

    specification and instructions of Engineer incharge.

    Cft 43.560

    S.NO MRS-2017 Description Unit Quantity

    1 03-23-b Excavation in foundation of building, bridges etc complete in ordinary soil Cft 2117.000

    2 26-15 Spraying anti-termite liquid mixed with water in ration of 1:40 Sft 882.000

    3 06-05-i

    P/L: P.C.C 1:4:8 in any part of building such as foundation, etc. using 1½" down

    graded stone aggregate i/c form-work, placing, compacting, leveling and curing

    etc. Complete as per specification and instructions of Engineer incharge.

    Cft 259.875

    Civil Works Kohat BHU Bazid Khel (New Building)

    Page 19 of 35

  • 4 06-06-a-03

    P/L: RCC 1:2:4 i/c using approved quality of crushed stones and fine agregate

    (sand) in roof slab, landing, wall, plienth beam & bands including mixing in

    concrete mixer, lifting, placing in steel fom work, vibrating, consolidating, dressing,

    levling and curing excluding the cost of re-inforcement bars and the cost of laborty

    quality test. Complete in all respect as per specification and instruction of Engineer

    icharge.

    Cft 1225.190

    5 06-07-c

    PF in position mild reinforcement defomed bars (40000 psi yield strenght) of any

    size and dimetter including straightening , bending, placeing, binding in position

    with binding wire, placing spacesers. Complete in all respects as per specification

    and instruction of Engineer incharge.

    M.Ton 4.925

    6 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat , one layer polythene and

    one coat bitumen ( 2" thick)Sft 217.954

    7 07-04-a-03

    P/L: 1st class approved solid BB masonry in walls over 115mm thicks, laid and

    jointed in CM 1:4, straight or to corve with inner radious of 6m and over, upto

    4.25m depth, including racking out the joints where necessary scaffolding & curing

    etc. Complete in all respect as per specification and instruction if Engineer

    incharge.

    Cft 1625.438

    8 07-05-a-03

    P/L: 1st class approved solid BB masonry in walls 115mm thicks, laid and jointed in

    CM 1:4, straight or to curve with inner radious of 6m and over, upto 4.25m depth,

    including racking out the joints where necessary scaffolding & curing etc. Complete

    in all respect as per specification and instruction if Engineer incharge.

    Cft 1220.016

    9 11-09-b

    P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand mortar includind

    scafolding, chambering of edges, rounding the corners , making groves and edges

    where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12" wide at all joints

    of R.C.C and brick work, curing, cleaning, complete in all respect, specifications and

    instructions of engineer incharge.

    Sft 6880.641

    10 13-30-a + 2 x 13-30-b

    Surface prepartion (for dempenss) by provission of film with Alkali resisting primer

    on plaster wall and ceilling . Including first coat of painting new or old work such

    as walls including all detacheched attachement with plast emulsion paint.

    Including subsequent tywo coats of emulsion paints.

    Sft 6880.641

    11 10-03-a

    Provding sand cushion in lyers as specified under concreet, road, hard standing and

    landing including dressing, leveling, compacting and consolidating as per

    specification and instruction of the Engineer Inchage.

    Cft 790.500

    12 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft 260.865

    13 10-48-aProvding and laying porceline tile floor 1/4 inch thick laid cement 1:2 or 3/4 inch

    thick cement mortar 1:2 (local master tiles)Sft 961.063

    14 12-07-aFirst class doadar wood wrought joinery in doors and window etc complete : 2 inch

    thickSft 147.000

    15 12-20-a-02 Extra for providing /fixing approved quality rim locks : local Nos 6.000

    Page 20 of 35

  • 16 12-56-a

    Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type chowkat including

    fixing and position with all charges for hold fast hinges and paint etc complete in

    all respect as per drawings and as per specification as directed by engineer

    incharge

    Rft 169.000

    17 25-39-b-03

    Providing and fixing steel window 18 gauge with openable glazed panels with 22

    SWG wire gauze glass pane 3 mm including grill complete in all respect as per

    drawings and specification and as per directed by the engineer incharge

    Sft 80.000

    18 12-49Curtain railing to doors and windows comprising toso-elite japanees railing or

    equivalent inclunding paintRft 18.000

    19 NSI Provision and fixing of blind to windows as per direction of engineer incharge Sft 216.000

    20 24-17

    Supply and fixing of aproved AC building pipe Class , 80mm with pigot and socket

    joints and hexagonal head for rain water including jointing and suport MS Plate

    19mm x 6mm @ 1m apart. Complet in all respect and in accordance with

    specification and instruction of the Engineer Incharge.

    Rft 78.000

    21 09---5

    Supply and fixing of one lyer of brick tile (300mm x 150mm) x 50mm flat brick on

    roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage), one coat of hot

    bitumen (10 - 15 grade) and one lyer of approve polythene sheet. Complet in all

    respect and in accordance with specification and instruction of the Engineer

    Incharge.

    Sft 882.000

    22 06-05---H

    P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone aggregate i/c

    form-work, placing, compacting, leveling and curing etc. Complete as per

    specification and instructions of Engineer incharge.

    Cft 122.000

    S. NO MRS-2017 Description Unit Quantity

    IE-1 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC insulated Each 32.000

    IE-2 15-05-eSupply and Erection 7/.044" single core Copper PVC insulated 250/440 voltage

    grade cable.Rft 850.000

    IE-3 15-81 Supply and fixing 20 ampere power pluge Each 8.000

    IE-4 15-82 Supply and fixing 30 ampere power pluge Each 16.000

    IE-5 15-83 Supply and fixing 10 ampere power pluge Each 12.000

    IE-6 15-68-cSupply and Erection best quality AC ceiling fan completewith GI rod, canopy,

    blades & regulator : 56" sweepEach 10.000

    IE-7 NSI

    Supply & Installation of 12" sweep, plastic body, Exhaust fan including all civil

    works required for complete installation and of Asia/Climax/Pak fan made

    including all labour and materials cable as required at site and as approved by the

    Engineer Incharge. (Exaust fan will be fitted in proper steel frame along with wire

    gauze at external side)

    Each 12.000

    IE-8 15-25 Supply and Erection girder clamp hook, 5/8" dia.for hanging ceiling fan Each 12.000

    IE-9 15-61-aSupply and Erection fluorescent tube light fitting including 4' rod, choke, starter,

    flexible wire etc : SingleEach 28.000

    Internal Electrification works Kohat BHU Bazid Khel

    Page 21 of 35

  • IE-10 15-53Special Earthing of iron/metal clad switches etc with copper wire No. 8 SWG in GI

    pipe 1/2" diaEach 2.000

    E-11 Distribution Board:

    15-71-d Supply and Erection single phase imported auto circuit breaker 30 Amp. Each 8.000

    15-71-a Supply and Erection single phase imported auto circuit breaker 6 Amp Each 28.000

    15-71-b Supply and Erection single phase imported auto circuit breaker 15 Amp Each 24.000

    NSISupply and Erection Cubical Type Factory Fabricated floor/wall mounting steel

    main board comp. : RecessedNo 2.000

    IE-9 NSI

    Providing and fixing of distribution board along with best quality electric button

    and dimmer complete with all accesoories as recommended by the Engineer

    Incharge (Labour room and recovery room)

    No 4.000

    NSI

    Providing and fixing of distribution board along with best quality electric button

    and dimmer complete with all accesoories as recommended by the Engineer

    Incharge (Wash Room and Verandah)

    No 4.000

    Sub Head MRS-2017 Description Unit Quantity

    Sanitary

    14-01-a

    P/F: European type WC (ICI Boch or equivalent) i/c flush Tanki, P/Trap, Stop Cock,

    Plastic Connection etc. Complete as per specification and instruction of Engineer

    Incharge(Porta , Duur or equivalent )

    Each 5.000

    14-05-b-01Providing and fixing glazed earthen WHB complte with pedistal white size 25" x 18"

    Each 3.000

    14-27 Providing and fixing CP mixing valve for WHB/SHOWER Each 3.000

    14-24-b Providing and Fixing CP bib-cock, heavy type : 1/2" Each 10.000

    14-17P/F: of 22"x16"best quality 5mm mirror glass of approved quality. Complete in all

    respect as per specification and instruction of Engineer incharge. Each 3.000

    14.20 cP/F: best quality towel rail of approved quality as per specification and instruction

    of engineer incharge Each 3.000

    14.20 bP/F: best quality paper holder of approved quality as per specification and

    instruction of engineer inchargeEach 5.000

    14.20 aP/F: best quality plastic soap dish of approved quality as per specification and

    instruction of engineer incharge Each 3.000

    14-28-a Providing and Fixing gun metal peet / gate valve (screwed) 1" dia Each 6.000

    14-31-bProviding and Fixing CI floor trap including CI grating & concrete chamber all round

    : 4"x3"Each 2.000

    Water supply 14-55-e Providing and Fixing GI pipe & including specials complete 3/4" dia (light) RFt 890.000

    14-55-f Providing and Fixing GI pipe & including specials complete 1/2" dia (light) RFt 500.000

    14-69-b-03 P/F Fibre Glass Water Tank 400 gallons Each 3.000

    Sewerage14-70-a

    Providing and Fixing of pipe type B nikasi system including testing in all respect 110

    mm (using dadex, or eq)Rft 225.000

    NSIProviding and Fixing of pipe type wind pipe system including testing in all respect

    of 2 inch with capRft 110.000

    14-37-c Supply and Fixing CI manhole cover with frame etc complete 25" dia Each 7.000

    Water Supply and Sanitation Works Kohat BHU Bazid Khel

    Page 22 of 35

  • 23-10 Construction of septic tank (7' x 2' x 5') complete in all respect) Each 2.000

    23-11Construction of Soakage pit having 6 Rft dia and 10 Rft deep filled with brick and

    brick linning at sideEach 2.000

    NSI

    Construction of manholes 2'X2' in size including excavation, backfilling, 9" thick

    brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick cement sand plaster

    complete.

    Each 8.000

    S No. MRS Code 2017 Description Units Nos Length WidthHeight/Dep

    th

    Total

    Quantities

    117-10-b-01 4" thick PCC lining, using washed screened &

    graded/curshed stone aggregate : On slope : Ratio 1:2:4 for wall Cft 2.000 300.000 0.330 0.500 99.000

    2 11-08-a Cement plaster 1:3 upto 20' height 3/8" thick Sft 2.000 250.000 2.500 1250.000

    3 07-05-a-05 Pacca brick work in ground floor Cement, sand mortar 1:6 Cft 1.000 250.000 0.750 2.500 468.750

    413-05-a-01+2x 13-

    05-a-02

    Painting old corrugated surfaces, pent roofing etc. with oil first and subsequent

    coatSft 2.000 8.000 6.000 0.000 96.000

    3 14-81-aSupply and fixing of 3.0 HP Monoblock water pump 1.5"x1.5" size 5 stage DE-S5

    model single phase for 220 ft head with all accessories.No 1.000 1.000 1.000

    4 24-02-d-01Tubewell boring in all soils except shingle/rock From 300'

    to 400' below ground : 8" i/dNo 1.000 150.000 150.000

    5 24-12-c-01Providing and installing PVC blind pipe in tubewell with

    strainer BSS Class 'D' working pressure : 6" i/dRft 1.000 -38.000 -38.000

    6 24-09-c-0Providing and installing PVC strainer, in tubewell

    borehole comp. BSS Class 'D' working pressure : 6" i/dRft 1.000 39.000 39.000

    7 24-14Shrouding with graded pack grave 3/8" to 1/8" around

    tubewell in bore holeCft 1.000 60.000 60.000

    8 24-30-a-01Providing and Laying HDPE pipe Din-/Din-/ISO-4427

    incl testing & disinfect complete (20mm diaRft 1.000 160.000 160.000

    9 24-16-c-02Providing and Laying cut, joint, test & disinfect GI pipe

    line Using light quality GI Pipe : 3/4" i/d Rft 1.000 90.000 90.000

    12 14-69-a-03 P/F Fibre Glass Water Tank 500 gallons Each 1.000 1.000 1.000

    13 14-03-aProviding and Fixing glazed earthen ware WC squatting type with built-in foot rests

    : WhiteNo 2.000 2.000 4.000

    14 14-05-a-02 Providing and Fixing glazed earthen ware WHB complete No 2.000 4.000 2.000

    15 14-31-b Floor Trap complete with fitting No 2.000 2.000 4.000

    17 23-02-a Providing and Laying non-reinforced concrete pipe Rft 2.000 80.000 160.000

    S.NO MRS-2017 Description Unit Quantity

    1 03-23-b Excavation in foundation of building, bridges etc complete in ordinary soil Cft 376.000

    Waiting Shed Kohat BHU Bazid Khel

    Rehabilitation Works Kohat BHU Bazid Khel

    Page 23 of 35

  • 2 06-05-i

    P/L: P.C.C 1:4:8 in any part of building such as foundation, etc. using 1½" down

    graded stone aggregate i/c form-work, placing, compacting, leveling and curing

    etc. Complete as per specification and instructions of Engineer incharge.Cft 62.000

    3 06-06-a-03

    P/L: RCC 1:2:4 i/c using approved quality of crushed stones and fine agregate

    (sand) in roof slab, landing, wall, plienth beam & bands including mixing in

    concrete mixer, lifting, placing in steel fom work, vibrating, consolidating, dressing,

    levling and curing excluding the cost of re-inforcement bars and the cost of laborty

    quality test. Complete in all respect as per specification and instruction of Engineer

    incharge.

    Cft 86.760

    4 06-07-c

    PF in position mild reinforcement defomed bars (40000 psi yield strenght) of any

    size and dimetter including straightening , bending, placeing, binding in position

    with binding wire, placing spacesers. Complete in all respects as per specification

    and instruction of Engineer incharge.

    M.Ton 0.350

    5 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat, one layer polythene and

    one coat bitumen ( 2" thick)Sft 39.550

    6 07-04-a-03

    P/L: 1st class approved solid BB masonry in walls over 115mm thicks, laid and

    jointed in CM 1:4, straight or to corve with inner radious of 6m and over, upto

    4.25m depth, including racking out the joints where necessary scaffolding & curing

    etc. Complete in all respect as per specification and instruction if Engineer

    incharge.

    Cft 164.500

    7 07-05-a-03

    P/L: 1st class approved solid BB masonry in walls 115mm thicks, laid and jointed in

    CM 1:4, straight or to curve with inner radious of 6m and over, upto 4.25m depth,

    including racking out the joints where necessary scaffolding & curing etc. Complete

    in all respect as per specification and instruction if Engineer incharge.

    Cft 242.440

    8 11-09-b

    P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand mortar includind

    scafolding, chambering of edges, rounding the corners , making groves and edges

    where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12" wide at all joints

    of R.C.C and brick work, curing, cleaning, complete in all respect, specifications and

    instructions of engineer incharge.

    Sft 735.000

    913-30-a + 2 x 13-

    30-b

    Surface prepartion (for dempenss) by provission of film with Alkali resisting primer

    on plaster wall and ceilling . Including first coat of painting new or old work such

    as walls including all detacheched attachement with plast emulsion paint.

    Including subsequent tywo coats of emulsion paints.

    Sft 735.000

    10 10-03-aProvding sand cushion in lyers as specified under concreet, road, hard standing and

    landing including dressing, leveling, compacting and consolidating as per

    specification and instruction of the Engineer Inchage.

    Cft 160.000

    11 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft 52.800

    12 10-48-aProvding and laying porceline tile floor 1/4 inch thick laid cement 1:2 or 3/4 inch

    thick cement mortar 1:2 (local master tiles)Sft 160.000

    13 24-16-c-08 Extra for providing /fixing approved quality rim locks : local Rft 36.000

    Page 24 of 35

  • 14 NSI P/L, cut, joint, test and disinfect MS pipe 1.5" X 2" Rft 100.000

    15 9--13--C S/F corrugated GI sheet with GI bolt,nuts,limpite 24 BWG Sft 216.000

    16 06-05-hP/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone aggregate i/c form-

    work, placing, compacting, leveling and curing etc. Complete as per specification

    and instructions of Engineer incharge.

    Cft 34.980

    17 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC insulated Each 1.000

    1815-05-e

    Supply and Erection 7/.044" single core Copper PVC insulated 250/440 voltage

    grade cable.Rft 75.000

    19 15-81 Supply and fixing 20 ampere power pluge Each 1.000

    20 15-78 Supply and Fixing bracket fan pak made complete Each 2.000

    2115-61-a

    Supply and Erection fluorescent tube light fitting including 4' rod, choke, starter,

    flexible wire etc : SingleEach 2.000

    22 NSI Benches for Patients. No 2.000

    S.NO MRS-2017 Description Unit Quantity

    1 03-23-b Excavation in foundation of building, bridges etc complete in ordinary soil Cft 2117.000

    2 26-15 Spraying anti-termite liquid mixed with water in ration of 1:40 Sft 882.000

    3 06-05-i

    P/L: P.C.C 1:4:8 in any part of building such as foundation, etc. using 1½" down

    graded stone aggregate i/c form-work, placing, compacting, leveling and curing

    etc. Complete as per specification and instructions of Engineer incharge.

    Cft 259.875

    4 06-06-a-03

    P/L: RCC 1:2:4 i/c using approved quality of crushed stones and fine agregate

    (sand) in roof slab, landing, wall, plienth beam & bands including mixing in

    concrete mixer, lifting, placing in steel fom work, vibrating, consolidating, dressing,

    levling and curing excluding the cost of re-inforcement bars and the cost of laborty

    quality test. Complete in all respect as per specification and instruction of Engineer

    icharge.

    Cft 1225.190

    5 06-07-c

    PF in position mild reinforcement defomed bars (40000 psi yield strenght) of any

    size and dimetter including straightening , bending, placeing, binding in position

    with binding wire, placing spacesers. Complete in all respects as per specification

    and instruction of Engineer incharge.

    M.Ton 4.925

    6 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat , one layer polythene and

    one coat bitumen ( 2" thick)Sft 217.954

    7 07-04-a-03

    P/L: 1st class approved solid BB masonry in walls over 115mm thicks, laid and

    jointed in CM 1:4, straight or to corve with inner radious of 6m and over, upto

    4.25m depth, including racking out the joints where necessary scaffolding & curing

    etc. Complete in all respect as per specification and instruction if Engineer

    incharge.

    Cft 1625.438

    Civil Works Kohat RHC Gumbat

    Page 25 of 35

  • 8 07-05-a-03

    P/L: 1st class approved solid BB masonry in walls 115mm thicks, laid and jointed in

    CM 1:4, straight or to curve with inner radious of 6m and over, upto 4.25m depth,

    including racking out the joints where necessary scaffolding & curing etc. Complete

    in all respect as per specification and instruction if Engineer incharge.

    Cft 1220.016

    9 11-09-b

    P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand mortar includind

    scafolding, chambering of edges, rounding the corners , making groves and edges

    where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12" wide at all joints

    of R.C.C and brick work, curing, cleaning, complete in all respect, specifications and

    instructions of engineer incharge.

    Sft 6880.641

    10 13-30-a + 2 x 13-30-b

    Surface prepartion (for dempenss) by provission of film with Alkali resisting primer

    on plaster wall and ceilling . Including first coat of painting new or old work such

    as walls including all detacheched attachement with plast emulsion paint.

    Including subsequent tywo coats of emulsion paints.

    Sft 6880.641

    11 10-03-a

    Provding sand cushion in lyers as specified under concreet, road, hard standing and

    landing including dressing, leveling, compacting and consolidating as per

    specification and instruction of the Engineer Inchage.

    Cft 790.500

    12 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft 260.865

    13 10-48-aProvding and laying porceline tile floor 1/4 inch thick laid cement 1:2 or 3/4 inch

    thick cement mortar 1:2 (local master tiles)Sft 961.063

    14 12-07-aFirst class doadar wood wrought joinery in doors and window etc complete : 2 inch

    thickSft 147.000

    15 12-20-a-02 Extra for providing /fixing approved quality rim locks : local Nos 6.000

    16 12-56-a

    Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type chowkat including

    fixing and position with all charges for hold fast hinges and paint etc complete in

    all respect as per drawings and as per specification as directed by engineer

    incharge

    Rft 169.000

    17 25-39-b-03

    Providing and fixing steel window 18 gauge with openable glazed panels with 22

    SWG wire gauze glass pane 3 mm including grill complete in all respect as per

    drawings and specification and as per directed by the engineer incharge

    Sft 80.000

    18 12-49Curtain railing to doors and windows comprising toso-elite japanees railing or

    equivalent inclunding paintRft 18.000

    19 NSI Provision and fixing of blind to windows as per direction of engineer incharge Sft 216.000

    20 24-17

    Supply and fixing of aproved AC building pipe Class , 80mm with pigot and socket

    joints and hexagonal head for rain water including jointing and suport MS Plate

    19mm x 6mm @ 1m apart. Complet in all respect and in accordance with

    specification and instruction of the Engineer Incharge.

    Rft 78.000

    Page 26 of 35

  • 21 09---5

    Supply and fixing of one lyer of brick tile (300mm x 150mm) x 50mm flat brick on

    roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage), one coat of hot

    bitumen (10 - 15 grade) and one lyer of approve polythene sheet. Complet in all

    respect and in accordance with specification and instruction of the Engineer

    Incharge.

    Sft 882.000

    22 06-05---H

    P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone aggregate i/c

    form-work, placing, compacting, leveling and curing etc. Complete as per

    specification and instructions of Engineer incharge.

    Cft 122.000

    S.NO MRS-2017 Description Unit Quantity

    IE-1 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC insulated Each 16.000

    IE-2 15-05-eSupply and Erection 7/.044" single core Copper PVC insulated 250/440 voltage

    grade cable.Rft 400.000

    IE-3 15-81 Supply and fixing 20 ampere power pluge Each 4.000

    IE-4 15-82 Supply and fixing 30 ampere power pluge Each 8.000

    IE-5 15-83 Supply and fixing 10 ampere power pluge Each 6.000

    IE-6 15-68-cSupply and Erection best quality AC ceiling fan completewith GI rod, canopy,

    blades & regulator : 56" sweepEach 4.000

    IE-7 NSI

    Supply & Installation of 12" sweep, plastic body, Exhaust fan including all civil

    works required for complete installation and of Asia/Climax/Pak fan made

    including all labour and materials cable as required at site and as approved by the

    Engineer Incharge. (Exaust fan will be fitted in proper steel frame along with wire

    gauze at external side)

    Each 4.000

    IE-8 15-25 Supply and Erection girder clamp hook, 5/8" dia.for hanging ceiling fan Each 6.000

    IE-9 15-61-aSupply and Erection fluorescent tube light fitting including 4' rod, choke, starter,

    flexible wire etc : SingleEach 10.000

    IE-10 15-53Special Earthing of iron/metal clad switches etc with copper wire No. 8 SWG in GI

    pipe 1/2" diaEach 1.000

    E-11

    15-71-d Supply and Erection single phase imported auto circuit breaker 30 Amp. Each 4.000

    15-71-a Supply and Erection single phase imported auto circuit breaker 6 Amp Each 14.000

    15-71-b Supply and Erection single phase imported auto circuit breaker 15 Amp Each 12.000

    NSISupply and Erection Cubical Type Factory Fabricated floor/wall mounting steel

    main board comp. : RecessedNo 1.000

    IE-9 NSI

    Providing and fixing of distribution board along with best quality electric button

    and dimmer complete with all accesoories as recommended by the Engineer

    Incharge (Labour room and recovery room)No 2.000

    Internal Electrification works Kohat RHC Gumbat

    Distribution Board:

    Page 27 of 35

  • NSI

    Providing and fixing of distribution board along with best quality electric button

    and dimmer complete with all accesoories as recommended by the Engineer

    Incharge (Wash Room and Verandah)No 2.000

    Sub Head MRS-2017 Description Unit Quantity

    Sanitary 14-01-a

    P/F: European type WC (ICI Boch or equivalent) i/c flush Tanki, P/Trap, Stop Cock,

    Plastic Connection etc. Complete as per specification and instruction of Engineer

    Incharge(Porta , Duur or equivalent )

    Each 5.000

    14-05-b-01 Providing and fixing glazed earthen WHB complte with pedistal white size 25" x 18" Each 3.000

    14-27 Providing and fixing CP mixing valve for WHB/SHOWER Each 3.000

    14-24-b Providing and Fixing CP bib-cock, heavy type : 1/2" Each 10.000

    14-17P/F: of 22"x16"best quality 5mm mirror glass of approved quality. Complete in all

    respect as per specification and instruction of Engineer incharge. Each 3.000

    14.20 cP/F: best quality towel rail of approved quality as per specification and instruction

    of engineer incharge Each 3.000

    14.20 bP/F: best quality paper holder of approved quality as per specification and

    instruction of engineer inchargeEach 5.000

    14.20 aP/F: best quality plastic soap dish of approved quality as per specification and

    instruction of engineer incharge Each 3.000

    14-28-a Providing and Fixing gun metal peet / gate valve (screwed) 1" dia Each 6.000

    14-31-bProviding and Fixing CI floor trap including CI grating & concrete chamber all round

    : 4"x3"Each 2.000

    Water supply 14-55-e Providing and Fixing GI pipe & including specials complete 3/4" dia (light) RFt 800.000

    14-55-f Providing and Fixing GI pipe & including specials complete 1/2" dia (light) RFt 500.000

    14-69-b-03 P/F Fibre Glass Water Tank 400 gallons Each 3.000

    Sewerage 14-70-aProviding and Fixing of pipe type B nikasi system including testing in all respect 110

    mm (using dadex, or eq)Rft 195.000

    NSIProviding and Fixing of pipe type wind pipe system including testing in all respect

    of 2 inch with capRft 110.000

    14-37-c Supply and Fixing CI manhole cover with frame etc complete 25" dia Each 7.000

    23-10 Septic Tank (int.Size: 7'x2'x5') complete Each 1.000

    23-11Construction of Soakage pit having 6 Rft dia and 15 Rft deep filled with brick and

    brick linning at sideEach 1.000

    NSI

    Construction of manholes 2'X2' in size including excavation, backfilling, 9" thick

    brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick cement sand plaster

    complete.

    Each 8.000

    Sub Head MRS-2017 Description Unit Quantity

    Water Supply and Sanitation Works Kohat RHC Gumbat

    2 Unit Typical Toilet Blocks Kohat RHC Gumbat

    Page 28 of 35

  • Foundation 03-23-d Excavation in foundation of building, bridges etc complete : in shingle/gravel Cft 145.000

    26-15 Spraying anti-termite liquid mixed with water in the ratio of 1:40 Sft 220.500

    03-60-c Structural backfill using Common Material available at Cft 68.910

    06-05-fPlain Cemen