  • “Bio Step 1”

    Oven Cassinetta

    MINERVA PROJECT

    Service Competence Center Gold Level Training 2012

  • Product Evolution

    Version 1.0

    Bio Step 1 oven

    Table of Contents

    Chapter List

    Whirlpool Europe

    Service Consulting Center

    Office +49-(0)711-81071-3567

    Mobile +49-(0) 172 750 5936

    Pasquale Lattuca

    Service Expert Food Preparation

    [email protected]

    Service Competence Center

    E:/Version/Version History.doc

  • Table of Contents M

    ine

    rva

    ov

    en

    Product Information

    General Information

    Project description

    Classification

    Power board change

    Mechanical changes

    New side grids

    Chassis structure

    Disassembling part

    New cavity sensor

    Service Competence Center

    New fixation of upper heating element

    New Program Chart

    Configuration & Test procedure

    Failure codes

  • Marketing Information

    Project description

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    • A-X% is a mktg claim (voluntary declaration or ‘super declaration’) based on the harmonized standard EN50304:60350 (the ‘wet brick’ test)

    • The energy consumption is X% less than the class A limit for the oven (considering its volume category)

    • The claim should be consistent with the energy consumption of the least consuming function declared on the energy label (plus tolerances)

  • Marketing Information

    Classification

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    Energy Consumption

    conventional heating mode

    Volume

    Energy Consumption

    forced air / convection mode

    Size category

  • Technical Information

    Classification

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    0,55

    0,60

    0,65

    0,70

    0,75

    0,80

    0,85

    0,90

    0,95

    1,00

    1,05

    50 55 60 65 70 75 80 85

    Bri

    ck T

    est

    Co

    nsu

    mp

    tio

    n (

    kWh

    )

    Volume (L)

    Actual Directive - Limit for A Class and Claims

    BOSCH HBA42B2 : 67 LiterDeclared consumption 0,79 kWh

    Class A limit 0,99 kWh

    A-20%

    FAGOR 6H760AX: 51 LiterDeclared Consumption 0,70 kWh

    Class A limit 0,79 kWh

    A-10%

    A-20%

    AEG: 74 LiterDeclared consumption 0,79 kWh

    Class A limit 0,99 kWh

    A-20%

    A-20%

    AEG: 74 LiterDeclared consumption 0,89 kWh

    Class A limit 0,99 kWh

    A-10%

    A-20%

  • Technical Information

    Classification

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    Q1 2012 Platform

    MINERVA 67

    MINERVA 55

    FLAT

    MINERVA 55

    EMBOSSED

    VULCANO

    FLAT

    A-20% HE door G2

    A-10% All others

    A-20%

    Pyro, KA, STD

    Integrated Handle,

    STD HE door / NAV

    G2

    FLAGSHIP – NOT

    CHANGED

    A - class

    NOT CHANGED

    A-10% STD FGV door

    NAV – G2

    A-10% All others

    VULCANO

    EMBOSSED

    A class

    NOT CHANGED

    STEP 1 in execution

    Minerva 67: Modification to CONVECTION (MF8)

    OR GENTLE FAN (MF5) algorithm (to reduce

    evaporation during brick test)

    Minerva 55 Flat: cavity volume increase to move

    from medium to large cavity

    SKU IMPACTED BY STEP 1: 332

  • Technical Information

    Power board change

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    G2 EVO NAVIGATOR

    Description Modification of CONVECTION BAKE (MF8)

    or GENTLE FAN (MF5)

    by pulsing the CAVITY fan.

    The function will be used for energy

    declaration according to EN 60350 (2009).

    Fan operates for 3 s on a period of 30 s (with

    inertia will apparently rotate for 6 seconds)

    Function can be used for cooking (with a

    slightly different use from today)

    Modification of CONVECTION BAKE (MF8) by

    pulsing the CAVITY fan

    The function will be used for energy declaration

    according to EN 60350 (2009).

    Fan operates for 3 s on a period of 30 s (with

    inertia will apparently rotate for 6 seconds)

    Function can be used for cooking (with a

    slightly different use from today)

    TIME STARTING END FEB STARTING END FEB

    NOTE User may perceive that fan is pulsing

    (low duty cycle 10%). A line in IFU is

    necessary to explain the functionality.

    User may perceive that the fan is pulsing (low

    duty cycle 10%). A line in IFU is necessary to

    explain the functionality.

    Modification 1) EEPROM on POWER BOARD ESTER /

    Antares EVO

    2) Data for label and technical fiche

    3) IFU update (cooking table, function

    description)

    4) Service explanation sheet to be packed

    with the new spare parts of the control

    1) EEPROM on POWER BOARD

    Antares EVO

    2) Navigator

    (reference table to ANTARES function)

    3) Data for label and technical fiche

    4) IFU update (cooking table, function

    description

    Implementation by Running Change

    Change of the 12th digits

  • Technical Information

    Mechanical changes on cavity walls

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    ACTUAL LARGE - in Wk 1 2012

  • Technical Information

    New side grids

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    ACTUAL WILL BE INTRODUCED IN Wk1 - 2012 with large cavity

  • Technical Information

    Chassis structure

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    Current production New modified production

  • Technical Information

    New catalytic panel design

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    WILL BE INTRODUCED IN Wk 1 / 2012

    (Can also be used on older models)

  • Disassembling part

    New embossed cavity

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Disassembling part

    New cavity sensor

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    Remove the

    screw & slide

    the termostat +

    bracket out

  • Disassembling part

    New fixation of upper heating element

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Technical Information

    New progamm chart

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Technical information

    Configuration & Test procedure

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Technical information

    Test procedure

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Technical information

    Test procedure

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Technical information

    Test procedure

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Technical information

    Test procedure

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Technical information

    Test procedure

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Technical information

    Test procedure

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Technical information

    Test procedure

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Technical information

    Test procedure

    Min

    erv

    a o

    ve

    n

    Service Competence Center

  • Technical information

    Failure codes

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    Failure Code Failure Type Sentence on SAM display

    F01 Probe

    Temperature Probe error

    First check probe connection, if ok disconnect the probe and measure its

    resistance (1000W+3.75*Temp ambient). If value is in range change AM.

    F02 Temperature

    Temperature error.

    Check heating elements insulation (disconnect the heating element and

    check each terminal for continuity to GROUND). If there is no continuity

    change AM.

    F03 EEPROM

    EEPROM error.

    Reprogram EEPROM using SAM. If the problem persists change AM.

    F04 WIDE

    WIDE communication error.

    First check the connection on P007 of AM. If it is OK check the connection

    of the WIRE that start from AM P007 to the UI board. If it is ok connect a

    new UI and check if the appliance works properly. If not change the AM.

    F05

    Latch Latch error.

    (Pyro version only)

    First unplug the appliance, wait at least 10sec then reconnect. Verify that

    latch system repositioning works correctly (door has to be closed, motor has

    to run). If this happens, check the connection between AM and door latch

    system. If it is ok check micro switch functionality (door switch open if the

    door is open and latch switch open if the door is unlocked). If switches are

    ok then change AM.

  • Technical information

    Configuration & Test procedure

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    F06

    Door Door error.

    (Pyro version only)

    First check connection between AM and door latch system. If it is ok

    check door switch functionality (open circuit if the door is open,

    closed circuit if the door is closed). If switch is ok then change AM.

    F07 Cooking parameter data set error

    Data set error.

    Reprogram Cooking Parameter using SAM. If the problem persists

    change AM.

    F08 UI EEPROM error

    User Interface EEPROM error.

    Change UI (Navigator or Atlas).

    F09 UI SPI memory error

    UI SPI memory error.

    Change UI (Navigator or Atlas).

    F10 Function knob error

    The value read is not allowed for the selected knob.

    First check connection between UI (dummy or smart) and the knob. If

    it is ok reprogram Oven Manual Configuration using SAM. If the

    problem persists change the knob. If the problem still persists change

    the AM.

    F11 6TH sense error

    6TH

    sense error, Voltage error and Current error.

    Change AM.

  • Questions & answers

    Min

    erv

    a o

    ve

    n

    Service Competence Center

    END