APC by Schneider Electric – Bill Pasquill SSPCNSV Installation ● Steps needed to install PCNSV on VMware ESX server 3.5 ● Mount CD ● Copy files ● Run Installation Script ● Open network ports ● Run Configuration Script

Upload: giles-marsh

Post on 03-Jan-2016

217 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

SSPCNSV Installation

●Steps needed to install PCNSV on VMware ESX server 3.5●Mount CD●Copy files●Run Installation Script●Open network ports●Run Configuration Script

Page 2: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

Install CD and mount the CDVMware is Linux based. There should be a mount point under the root

director

In this example the mount point is /mnt/cdrom

The command to mount the CD is Mount /dev/cdrom /mnt/cdrom ( there is a space between cdrom and the / )

To unmount Umount /mnt/cdrom

.

Page 3: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

Files found on CD

.

Page 4: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

Copy files to temp directory In this case I copied the files to a directory called downloads From within the CD directory the command is CP * /downloads (this copies all file from the CD directory to the downloads

directory)

Note You don’t need to copy the files onto the harddrive. The installation can be run from the mounted CDROM.

Page 5: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

Run the installation ./install.shYou must be in the directory that hold the install.sh file or enter the entire path.

Select the proper number of instances required

Page 6: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

Select the desired installation directoryThe default is /opt/APC/PowerChuteVMware is case sensitive

Page 7: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

Select the desired installation of JAVAYou can use one already installed on the system or use the bundledI recommend the bundled.

Page 8: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

Once the installation is complete network ports need to be opened to allow communications to the UPS and via Internet Explore

Note: apcups is a profile being created to allow access to these setting via VMware client application.

“esxcfg-firewall -o 3052,udp,in,apcups”

“esxcfg-firewall -o 3052,udp,out,apcups”

“esxcfg-firewall -o 3052,tcp,in,apcups”

“esxcfg-firewall -o 3052,tcp,out,apcups”

“esxcfg-firewall -o 6547,tcp,in,apcups”

“esxcfg-firewall –o 80,tcp,in,apcups”

“esxcfg-firewall –o 80,tcp,out,apcups”

“esxcfg-firewall –q”

Page 9: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

After opening the ports the program need to be configured. Run the

PCNSConfig.sh file that is found in /opt/APC/PowerChute/group1

./PCNSConfig.sh

Page 10: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

Select the type of configuration Single, Multiple, Parallel

Page 11: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

Enter the IP Address of the UPS

Page 12: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

Enter the User Name, Password, and Authentication PhraseAuthentication phrase is admin, user, phrase

Page 13: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

Access the PCNS client via Internet Explore as with any Windows system.

Page 14: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

How to Uninstall

CD to /opt/APC/PowerChute

Run the uninstall script ./uninstall

Page 15: APC by Schneider Electric– Bill Pasquill SSPCNSV Installation ●Steps needed to install PCNSV on VMware ESX server 3.5 ●Mount CD ●Copy files ●Run Installation

APC by Schneider Electric – Bill Pasquill

If help in needed with configuring virtual clients shutting down please refer to this VMware kbase

http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=1008182