TRANSCRIPT

  • 8/17/2019 Apparatus and Pdawrocedure

    1/6

    Apparatus and Material

    5.1 Material

    1. Gypsum

    2. Water Based Mud

    Figure 1 : Gypsum

    Figure 2 : Water-Based Mud

  • 8/17/2019 Apparatus and Pdawrocedure

    2/6

    Apparatus

    1. Viscometer

    2. Beaker

    . !patula

    ". Mud Balance

    5. Mass Balance

    #. $itmus %aper

    Figure : Viscometer

  • 8/17/2019 Apparatus and Pdawrocedure

    3/6

    Figure 4 : Beaker

    Figure 5: Spatulla / Stirrer

  • 8/17/2019 Apparatus and Pdawrocedure

    4/6

    Figure 6 : Mass Balance

    Figure 7 : Mud Balance

  • 8/17/2019 Apparatus and Pdawrocedure

    5/6

    6.0 PROCEDURE

    For viscometer 

    1. The power supply is first switched on then the mud sample is filled into the mud

    cup.

    2. The thermocouple is plugged in.

    3. The bob is screwed into the bob shaft until it is tight.

    4. The sleeve is tightening onto the rotor shaft.

    5. The mud sample is placed on the stage by positioning the alignment stem over the

    corresponding hole on the stage.

    For unit measurement

    i. Go button !fter enter the test step" #ress 1.ii. $et up button #ress 2 will display the test set up screen" enter the parameter 

    for the temperature and rotational speed for the first step of the test. %nter 

    twice to return to main screen.iii. &eview button !fter running the test" press 3 to allow to allow review the test

    result.

    '. The speed of the viscometer is set to 3(( rpm and the data is recorded. $tep 1'

    is repeated using '(( rpm.

    %)perimental procedure

    1. ! 4(( ml water based mud is measured in a bea*er.

    2. The mud is test for weight" plastic viscosity and yield point using viscometer. The

    data is recorded in the table.

    3. The water based mud is then divided separately into two different bea*ers with

    2(( ml in each bea*er.

    4. Then" the bea*er is labeled as +ea*er ! and +ea*er +.

    5. Five grams of gypsum is added for +ea*er ! and 15 grams for +ea*er +.

    '. The sample is stirred for three minutes using mi)er.

    ,. The sample is being rest for 15 minutes.

    -. $tep 2 is repeated for both +ea*er ! and +ea*er +.

  • 8/17/2019 Apparatus and Pdawrocedure

    6/6

    . !nother five grams of gypsum is added in both +ea*er ! and +ea*er +.

    1(. $tep '- is repeated and the data is recorded.