2018 NCEBC COMPLIANCE LETTER
APPENDIX B
Sprinkler-Standpipe:
Architectural:
Code Enforcement Jurisdiction:
Owner / Authorized Agent:
Structural:
Mechanical:
Plumbing:
Fire Alarm:
Electrical:
Civil:
DESIGNER
Owned By:
Address:
OSSA STUDIO PLLC
FIRM
JACK OSSA
NAME
City
704.890.2053
PHONE #LICENSE #
11709
County
Private
Phone #
State
SE HEALTH CASH STATIONSName of Project:
____________________ + ____________________ + ... ... = _____
Allowable Area of Occupancy A Allowable Area of Occupancy B
Actual Area of Occupancy A + Actual Area of Occupancy B
Separated Use (508.4)
< 1
< 1.00
Mixed Occupancy:
Special Uses (Chapter 4 - List Code Sections):
Utility and Miscellaneous
Storage
Mercantile
InstitutionalHazardous
Business
Primary Occupancy Classification (s)
Non-Separated Use (508.3)
Standpipes:
Fire District:
Construction Type:
FLOOR
Sprinklers:
Factory
Yes
Residential
No
A-1Assembly
Educational
A-2 A-3 A-4 A-5
NEW (SQ FT)
YesNo
EXISTING (SQ FT)
No
No
Yes
Yes
I-A
Class:
NFPA 13
I II
II-A
SUB-TOTAL
III-A
NFPA 13R
III WET
IV
DRY
III-B
Flood Hazard Area: YesNo
2018 APPENDIX BBUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS
State
Retaining Walls>5' High:
Other:
Constructed : (date)
I-B II-B
V-A
V-B
Partial NFPA 13D
Special Provisions (Chapter 5 - List Code Sections):
The required type of construction for the building shall be determined by applying the height and area limitations for each of the applicable occupancies to the entire building.The most restrictive type of construction, so determined, shall apply to the entire building.
See below for area calculations for each story, the area of the occupancy shall be such that the sum of the ratios of the actual floor area of each use divided by the allowable floor area for each use shall not exceed 1.
City / County
2018 NC Building Code: New Building
Emergency Lighting:
Exit Signs:
Fire Alarm:
Smoke Detection Systems:
Carbon Monoxide Detection:
Yes
Yes
Yes
No
No
No
Yes
Yes
No
No
Smoke Barrier Separation
Party/Fire Wall Separation
Corridor Separation
Shaft Enclosures- Other
Shaft Enclosures- Exit
Floor Ceiling Assembly
Floor Construction including support beams and joists
Bearing Walls
* Indicate section number permitting reduction
BUILDING ELEMENT
North
East
South
West
North
South
West
East
Story No.
DETAIL #AND
SHEET #REQ'D
FIRESEPARATION
DISTANCE(FEET)
PROVIDED
REDUCTION)
(W/___*
RATING DESIGN #FOR
RATED ASSEMBLY
DESIGN # FOR
RATEDPENETRATION
DESIGN #FOR
RATEDJOINTS
1,5(Actual)
Bldg Areaper Story
(A)
Table 506.2Area
(B) (C) (D)
Incidental Use Separation
Interior
Description and Use Area for
FrontageIncrease
AllowableArea or
Unlimited 2,3
1 Frontage area increases from Section 506.2 are computed thus:
a. Perimeter which fronts a public way or open space having 20 feet minimum width = _______ (F)
b. Total Building Perimeter = ________ (P)c. Ratio (F/P) = ___________ (F/P)d. W = Minimum width of public way = ________ (W)e. Percent of frontage increase If = 100 [ F/P – 0.25] x W/30 = ________ (%)
2 Unlimited area applicable under conditions of Section 507.
3 Maximum Building Area = total number of stories in the building x D (maximum3 stories) (506.2).
4 The maximum area of open parking garages must comply with Table 406.5.4.
5 Frontage increase is based on the unsprinklered area value in Table 506.2.
ALLOWABLESHOWN ON
PLANS
CODE
REFERENCE
Building Height in Feet (Table 504.3) 2
Structural Frame,including columns, girders, trusses
Exterior
Nonbearing Walls andPartitions Exterior walls
4
Interior walls and partitions
Occupancy / Fire Barrier Separation
Partial
LAVATORIESWATERCLOSETS
MALE FEMALE
SHOWERS/ TUBS
DRINKING FOUNTAINS
Lot or Parking Area
Total #AccessibleProvided
Total # of Parking Spaces # of Accessible Spaces Provided
Required ProvidedRegular with 5' Access Aisle
132" Access Aisle
F-1 Moderate
H-1 Detonate
I-1 Condition
R-1
S-1 Moderate
F-2 Low
H-2 Deflagrate
I-2 Condition
I-3 Condition
I-4
H-3 Combust H-4 Health H-5 HPM
R-2 R-3 R-4
S-1 Low High-piled
Parking Garage Open Enclosed Repair Garage
Accessory Occupancy Classification (s):
Incidental Uses (Table 509):
Fire Separation Distance (Feet) from Property Lines
Degree of Openings Protection (Table 705.8)
Allowable Area(%)
Fire and/or smoke rated wall locations (Chapter 7)Assumed and real property line locations (if not on the site plan)Exterior wall opening area with respect to distance to assumed property lines (705.8)Occupancy Use for each area as it relates to occupant load calculation (Table 1004.1.2)Occupant loads for each areaExit sign locations (1013)Exit access travel distances (1017)Common path of travel distances (Tables 1006.2.1 & 1006.3.2(1))Dead end lengths (1020.4)Clear exit widths for each exit doorMaximum calculated occupant load capacity each exit door can accommodate based on egress width (1005.3)Actual occupant load for each exit doorA separate schematic plan indicating where fire rated floor/ceiling and/or roof structure is provided for purposes of occupancy separationLocation of doors with panic hardware (1010.1.10)Location of doors with delayed egress locks and the amount of delay (1010.1.9.7)Location of doors with electromagnetic egress locks (1010.1.9.9)Location of doors equipped with hold-open devicesLocation of emergency escape windows (1030)The square footage of each fire area (202)The square footage of each smoke compartment for Occupancy Classification I-2 (407.5)Note any code exceptions or table notes that may have been utilized regarding the items above
(EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)(Reproduce the following data on the building plans sheet 1 or 2)
a. PROJECT INFORMATION
b. DESIGN PROFESSIONAL INFORMATION
d. BASIC BUILDING DATA
TOTAL
f. ALLOWABLE AREA
g. ALLOWABLE HEIGHT
h. FIRE PROTECTION REQUIREMENTS
i. PERCENTAGE OF WALL OPENING CALCULATION
Actual Shown on Plans(%)
j. LIFE SAFETY SYSTEM REQUIREMENTS
APPENDIX B
l. ACCESSIBLE DWELLING UNITS (Section 1107)
TOTAL UNITS
ACCESSIBLE UNITS
REQUIRED
ACCESSIBLEUNITS
PROVIDED
TYPE AUNITS
REQUIRED
TYPE AUNITS
PROVIDED
TYPE BUNITS
REQUIRED
TYPE BUNITS
PROVIDED
TOTAL ACCESSIBLE UNITS PROVIDED
m. ACCESSIBLE PARKING (Section 1106)
8' Access Aisle
Total
o. SPECIAL APPROVALS
n. PLUMBING FIXTURES REQUIREMENTS (Table 2902.1)
USE
APPENDIX B
(Local Jurisdiction, Department of Insurance, OSC, DPI, DHHS, etc., describe below)
p. ENERGY SUMMARY
Per exception #1 of sections 410.7; 806.2; or 906.1, costs of providing the accessible route are not required to exceed 20% of the costs of the alterations affecting the area of primary function.
A. ESTIMATED COST OF ALTERATIONS TO AREA OF PRIMARY FUNCTION:
B. MAXIMUM REQUIRED COST OF IMPROVEMENTS TO ACCESSIBLE ROUTE (20% OF LINE “A” ABOVE):
ACCESSIBLE ROUTE EXPENDITURE LOG
DESCRIPTION OF IMPROVEMENTS TO ACCESSIBLE ROUTE TO THE PRIMARY FUNCTION
AREA
DRAWING OR DETAIL
REFERENCE
ESTIMATED COST ($) PER
IMPROVEMENT
TOTAL COST OF COMBINED IMPROVEMENTS TO ACCESSIBLE ROUTE
-
249 BILLINGSLEY ROAD, CHARLOTTE NC 28211
PAUL GETCHELL 704.905.4664
c. CODE DATA
Repair
Level IILevel I Level III
Historic Property Change of Use
Separation: Hr. Exception:
Reference: NCEBC Section 410.7; 806.2; & 906.1 - Alterations affecting an area containing a primary function.
This project represents work in an existing building that includes alterations to the primary function area. The following exceptions from Section 410.7; 806.2; or 906.1 are applicable.
EXCEPTIONS (CHECK ALL THAT APPLY):
Exception #1 - Costs of providing an accessible route are not required to exceed 20% of the costs of the alterations affecting the area of primary function. (If this exception is used, please be sure to include items A., B. and an Expenditure Log, such as in the example that follows below, on the submitted plans.)
Exception #2 - Alterations limited solely to windows, hardware, operating controls, electrical outlets and signs
Exception #3 - Alterations limited to mechanical systems, electrical systems, installation or alteration of fire protection systems and abatement of hazardous materials.
Exception #4 - Alterations undertaken for the primary purpose of increasing the accessibility of an existing building, facility or element.
Exception #5 - This provision does not apply to altered areas limited to Type B dwelling and sleeping units.
Existing accessible route (parking, route to building entrance, building entrance, route through building to primary function area, toilets and drinking fountains serving the primary function area) are in full compliance with current accessibility requirements.
$80,000
$16,000
1969
40,0451st FLOOR
40,045
NOT APPLICABLE
NOT APPLICABLE
EXISTING TO REMAIN
EXIST'G
REVISION TO EXISTING CLINIC-A CHECK-IN COUNTER
$10,000
Prescriptive Chapter 14
ENERGY REQUIREMENTS: The following data shall be considered minimum and any special attribute required to meet the energy code shall also be provided. Each Designer shall furnish the required portions of the project information for the plan data sheet. If performance method, state the annual energy cost for the standard reference design vs annual energy cost for the proposed design.
Existing building envelope complies with code:
Yes (The remainder of this section is not applicable)No
Exempt Building: Provide code or statutory reference:
YesNo
Climate Zone: 3A 4A 5A
Method of Compliance: Energy Code Performance PrescriptiveAshrae 90.1 Performance Prescriptive(If “Other” specify source here)
THERMAL ENVELOPE: (Prescriptive Method Only)
Roof/ceiling Assembly (each assembly)Description of assembly: ______________________________U-Value of total assembly: ___________R-Value of insulation: ___________Skylights in each assembly: ___________
U-Value of skylight: ___________total square footage of skylights in each assembly: ___________
Exterior Walls (each assembly)Description of assembly: ______________________________U-Value of total assembly: ___________R-Value of insulation: ___________Openings (windows or doors with glazing)
U-Value of assembly: ___________Solar heat gain coefficient:___________projection factor: ___________Door R-Values: ___________
Walls below grade (each assembly)Description of assembly: ______________________________U-Value of total assembly: ___________R-Value of insulation: ___________
Floors over unconditioned space (each assembly)Description of assembly: ______________________________U-Value of total assembly: ___________R-Value of insulation: ___________
Floors slab on gradeDescription of assembly: ______________________________U-Value of total assembly: ___________R-Value of insulation: ___________Horizontal/vertical requirement:___________slab heated: ___________
(“Other” should include firms and individuals such as truss, precast, pre-engineered, interior designers, etc.)
Addition Renovation
2018 NC Existing Building Code:
Renovated : (date)
Current Occupancy(s) (Ch. 3) MEDICAL OFFICE (BUSINESS)
Proposed Occupancy(s) (Ch. 3)
Risk Category : (Table 1604.5)
I IICurrent:
Proposed:
Special Inspections Required: Yes (Contact the local inspection jurisdiction for additional procedures and requirements.)No
e. GROSS BUILDING AREA TABLE
APPENDIX B
Building Height in Storiesin (Table 504.4) 3
1 Provide code reference if the “Shown on Plans” quantity is not based on Table 504.3 or 504.4. 2 The maximum height of air traffic control towers must comply with Table 412.3.1. 3 The maximum height of open parking garages must comply with Table 406.5.4.
Columns Supporting Floors
Roof Construction including support beams and joists
Roof Ceiling Assembly
Columns Supporting Roof
Smoke Partition
Tenant / Dwelling Unit / Sleeping Unit Separation
k. LIFE SAFETY PLAN REQUIREMENTS
UNISEX
NEW
REQ'D
SPACE
2018 APPENDIX BBUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS
STRUCTURAL DESIGN(SEE STRUCTURAL SHEETS IF APPLICABLE)
2018 APPENDIX BBUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS
MECHANICAL DESIGN(SEE THE MECHANICAL SHEETS IF APPLICABLE)
2018 APPENDIX BBUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS
ELECTRICAL DESIGN(SEE THE ELECTRICAL SHEETS IF APPLICABLE)
Van Spaces With
Email: [email protected]
Shell/Core - Contact the local inspection jurisdiction for possible additional procedures and requirements.
1st Time Interior Completion
Phased Construction - Shell/Core- Contact the local inspection jurisdiction for possible additional procedures and requirements.
Existing:
Alteration:
III IV
I II III IV
1
1
1
2
2
2 3 4 5
URINALS
MALE FEMALE UNISEX REGULAR ACCESSIBLE
MEDICAL OFFICE (BUSINESS)
1ST FLOOR MEDICAL OFFICE 40,045 23,000 17,250 40,250
915
915
1
30
75
55 18
3 1
60'
60'
60'
60'
0
0
0
0
0
0
0
0
0
0
0
0
N/A
N/A
0
0
0
N/A
N/A
0
0
0
0
0
N/A
0
0
0
0
0
0
0
0
0
0
0
0
0
N/A
N/A
0
0
0
N/A
N/A
0
0
0
0
0
N/A
0
60'
60'
60'
60'
EXISTING TO REMAIN
REVISION TO EXISTING CLINIC-B CHECK-IN COUNTER
$10,000
$20,000
3 / A02.01
3 / A02.02
3
N/AN/AN/A
N/A
N/A
N/AN/AN/AN/AN/A
N/AN/A
© Ossa Studio
Date Description
Client
Project Number
Description
Scale
2021
Project Name
1515 MOCKINGBIRD LANE SUITE 7127
CHARLOTTE NC
704.890.2053
WWW.OSSASTUDIO.COM
PROJECT TEAM
12" = 1'-0"
10/4
/202
1 5:
50:4
9 P
MZ
:\Sha
red\
3 -
Pro
ject
s\21
0 15.
00\3
.2 -
Des
ign \
3.2a
- B
IM\a
- C
e ntr
al M
odel
File
\21 0
15.0
0_S
E H
ealt h
Cas
h S
tatio
ns.r
v t
A00.02
COVER SHEET & APPENDIX B
21015.00
MECKLENBURG COUNTY
249 BILLINGSLEY ROAD,CHARLOTTE NC 28211
9/10/2021 ISSUED FOR CONSTRUCTION
9/23/2021
SE HEALTH CASHSTATIONSSheet Number Sheet Name
Revisions
Current Revision DescriptionLatest Date
ARCHITECTURAL
A00.02 COVER SHEET & APPENDIX B 3 9/23/2021 PLAN REVIEW REVISIONS
A00.04 ACCESSIBILITY REFERENCE DETAILS
A02.00 AREA OF WORK 3 9/23/2021 PLAN REVIEW REVISIONS
A02.01 CLINIC A 4 10/4/2021 FIRE ALARM REVISIONS
A02.02 CLINIC B 5 10/4/2021 MILLWORK REVISIONS
10/4
/202
1 5:
50:4
9 P
MZ
:\Sha
red\
3 -
Pro
ject
s\21
0 15.
00\3
.2 -
Des
ign \
3.2a
- B
IM\a
- C
e ntr
al M
odel
File
\21 0
15.0
0_S
E H
ealt h
Cas
h S
tatio
ns.r
v t
PLAN REVIEW REVISIONS9/23/2021
9/10/2021
SE HEALTH CASH STATIONS
249 BILLINGSLEY ROAD, CHARLOTTE NC 28211 ISSUED FOR CONSTRUCTION
3 9/23/2021 PLAN REVIEW REVISIONS
3
3
3
3
(A) CIRCULAR
(B) T-SHAPED
48" MIN
30
" M
IN.
1/4"
MA
X1/
2" M
AX
1/4"
MA
X
1/4"
- 1
/2"
2
1
2
1
CARPET ON FLOOR SURFACES
TOE CLEARANCE
KNEE CLEARANCE
(A) ELEVATION
(B) PLAN(A) ELEVATION
(B) PLAN
60" MIN
60" MIN
36"
MIN
24"
MIN
60"
MIN
12" MIN 36" MIN 12" MIN
9"
MAX
6"
30"
MIN
30"
MIN
MIN
8"
27"
MIN
9" M
IN
11" MIN
17" - 25"
25" MAX
UNOBSTRUCTED FORWARD REACH
OBSTRUCTED HIGH FORWARD REACH
(A) (B)
UNOBSTRUCTED SIDE REACH
OBSTRUCTED HIGH SIDE REACH
(A) (B)
10" MAX
34"
MA
X
48"
MA
X
> 10" - 24"
34"
MA
X
46"
MA
X
10" MAX
15"
MIN
48"
MA
X
36"
MIN
32"
MIN
24" MAX 48" MIN 24" MAX
32"
MIN
36"
MIN
ALL DIAGRAMS ON THIS SHEET ARE REFERENCED FROM :
ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
ICC A117.1-2009
ANSI - AMERICAN NATIONAL STANDARD
15"
MIN
48"
MA
X
20" MAX
48"
MA
X
> 20" - 25"
44"
MA
X
X >
27"
4" MAX
X >
80"
CLEAR FLOOR SPACE
TURNING SPACE
CHANGES IN LEVELCLEAR WIDTH OF AN ACCESSIBLE ROUTE
KNEE AND TOE CLEARANCE
REACH RANGES
PROTRUDING OBJECTS
(A) FRONT APPROACH, PULL SIDE
* IF BOTH CLOSER AND LATCH ARE PROVIDED
(B) FRONT APPROACH, PULL SIDE
(C) HINGE APPROACH, PULL SIDE (D) HINGE APPROACH, PULL SIDE
* IF BOTH CLOSER AND LATCH ARE PROVIDED
** 48" MIN IF BOTH CLOSER AND LATCH PROVIDED
(E) HINGE APPROACH, PUSH SIDE
* 54" MIN IF CLOSER IS PROVIDED
(F) LATCH APPROACH, PULL SIDE
* 48" MIN IF CLOSER IS PROVIDED
(G) LATCH APPROACH, PUSH SIDE
(A) HINGED DOOR
(C) FOLDING DOOR(D) DOORWAYS WITHOUT DOORS
(B) SLIDING DOOR
60"
MIN
18" MIN
12" MIN *
48"
MIN
60"
MIN
36" MIN
54"
MIN
42" MIN
42"
MIN
**
22" MIN
12" MIN *
48"
MIN
*
24" MIN
42"
MIN
*
24" MIN
32" MIN
90
32" MIN
36" MIN
> 2
4"
32" MIN
12" MIN
X X
X = TREAD DEPTH
12" MIN
12" MIN
34"
- 38
"
24"
- 38
"
(A) STAIRS (B) RAMPS HANDRAIL CLEARANCE
1 1/2" MIN
4" M
IN. -
7"
MA
X.
11" MIN.
MANEUVERING CLEARANCE MANUAL SWINGING DOORS
CLEAR WIDTH OF DOORWAYS
HANDRAIL EXTENSION AT STAIRS
TOP AND BOTTOM EXTENSION AT RAMPS
HANDRAIL HEIGHT
TREADS AND RISERS
1' - 0"
1' -
6"
STAIR 1
2LEVEL 2
LEVELS 1 - X
EXIT DOWN
TO LEVEL 1
NO ROOF ACCESS
EXIT
6"
3"
STAIRWAY IDENTIFICATION SIGNS REQUIRED AT EACH
FLOOR LANDING INSIDE EXIST STAIRWAYS.
EXIT SIGNAGE TO BE PLACED ADJACENT TO
DOORWAYS AT EVERY EXIT STAIRWAY, EXIT
PASSAGEWAY AND EXIT DISCHARGE
RESTROOM
MEN
WOMEN
6"
6"
9"
6"6"
MANAGEMENTOFFICE 1013"
1/4" BRAILLE SIGNAGE, TYP.
1" SIGNAGE LETTERS, TYP.
TOP OF SIGN 5'-0" AFF
PROVIDE SIGNAGE IN ACCORDANCE WITH
2018 NCBC SECTION 1111, SECTION 2902.4
AND ICC A117.1 - 2009, SECTION 703.
STAIRS
UNISEX RESTROOM
ELEVATOR
LOBBY
8"
6"
ELEVATOR LOBBY IDENTIFICATION SIGN
REQUIRED AT INTERIOR SIDE OF EXIT STAIRWAY
DOOR LEADING TO ELEVATOR LOBBY.
TOP OF SIGN 5'-0" AFF
1/4" BRAILLE SIGNAGE, TYP.
1" SIGNAGE LETTERS, TYP.
ELEVATOR LOBBY
MEN RESTROOM
WOMEN RESTROOM
9"
6"
9"
6"
EXIT SIGNAGE
PERMANENT ROOM SIGN
6"
1/4" BRAILLE SIGNAGE, TYP.
5/8" SIGNAGE LETTERS, TYP.
1/4" BRAILLE SIGNAGE, TYP.
5/8" SIGNAGE LETTERS, TYP.
1/4" BRAILLE SIGNAGE, TYP.
5/8" SIGNAGE LETTERS, TYP.
1/4" BRAILLE SIGNAGE, TYP.
5/8" SIGNAGE LETTERS, TYP.
1/4" BRAILLE SIGNAGE, TYP.
1" SIGNAGE LETTERS, TYP.
TOP OF SIGN 5'-0" AFF
TOP OF SIGN 5'-0" AFF
TOP OF SIGN 5'-0" AFF
TOP OF SIGN 5'-0" AFF
TOP OF SIGN 5'-0" AFF
© Ossa Studio
Date Description
Client
Project Number
Description
Scale
2021
Project Name
NOT TO SCALE
1515 MOCKINGBIRD LANE SUITE 7127
CHARLOTTE NC
704.890.2053
WWW.OSSASTUDIO.COM
PROJECT TEAM
10/4
/202
1 5:
50:5
1 P
MZ
:\Sha
red\
3 -
Pro
ject
s\21
0 15.
00\3
.2 -
Des
ign \
3.2a
- B
IM\a
- C
e ntr
al M
odel
File
\21 0
15.0
0_S
E H
ealt h
Cas
h S
tatio
ns.r
v t
A00.04
ACCESSIBILITY REFERENCE DETAILS
21015.00
MECKLENBURG COUNTY
249 BILLINGSLEY ROAD,CHARLOTTE NC 28211
9/10/2021 ISSUED FOR CONSTRUCTION
9/22/2021
SE HEALTH CASHSTATIONS
SCALE: 1 1/2" = 1'-0"
CODE REQUIRED SIGNAGE01
BA C D E F G H I J K
1
2
3
4
5
6
7
38,560 SF
BUSINESS GROUP B(BUSINESS/OUTPATIENT • 100 GROSS)
386 OCCUPANTS
32" CLEAR WIDTH
40 OCCUPANTS
160 ALLOWABLE
32" CLEAR WIDTH
20 OCCUPANTS
160 ALLOWABLE
40" CLEAR WIDTH
100 OCCUPANTS
200 ALLOWABLE
40" CLEAR WIDTH
100 OCCUPANTS
200 ALLOWABLE
64" CLEAR WIDTH
125 OCCUPANTS
320 ALLOWABLE
32" CLEAR WIDTH
100 OCCUPANTS
160 ALLOWABLE
CLINIC B
CLINIC A
MAXIMUM DISTANCE TO EXIT: 140'
MAXIMUM COMMON PATH OF TRAVEL: 56'
MAXIMUM DISTANCE TO EXIT: 115'
MAXIMUM COMMON PATH OF TRAVEL: 35'
475 SF
BUSINESS GROUP B
(WAITING AREA • 15 GROSS)
32 OCCUPANTS
600 SF
BUSINESS GROUP B
(WAITING AREA • 15 GROSS)
40 OCCUPANTS
410 SF
BUSINESS GROUP B
(WAITING AREA • 15 GROSS)
27 OCCUPANTS
32" CLEAR WIDTH
45 OCCUPANTS
160 ALLOWABLE
32" CLEAR WIDTH
40 OCCUPANTS
160 ALLOWABLE
© Ossa Studio
Date Description
Client
Project Number
Description
Scale
2021
Project Name
1515 MOCKINGBIRD LANE SUITE 7127
CHARLOTTE NC
704.890.2053
WWW.OSSASTUDIO.COM
PROJECT TEAM
3/32" = 1'-0"
10/4
/202
1 5:
50:5
4 P
MZ
:\Sha
red\
3 -
Pro
ject
s\21
0 15.
00\3
.2 -
Des
ign \
3.2a
- B
IM\a
- C
e ntr
al M
odel
File
\21 0
15.0
0_S
E H
ealt h
Cas
h S
tatio
ns.r
v t
A02.00
AREA OF WORK
21015.00
MECKLENBURG COUNTY
249 BILLINGSLEY ROAD,CHARLOTTE NC 28211
9/10/2021 ISSUED FOR CONSTRUCTION
9/23/2021
SE HEALTH CASHSTATIONS
3 9/23/2021 PLAN REVIEW REVISIONS
3
3
3
3
3
3
33
3
3
3
3
F
F
F
A02.01 03
18"
MIN
.
A02.01
08
A02.01
06
5' -
5"
5' -
5"8"
5' - 0" MIN.
8"
12"
MIN
.
01
01
02
03
03
5 '- 0" MIN.
8" 8"
CR18"
MIN
.
12"
MIN
.
0402
03
03
04
INTERCHANGE (2) DOORS TO REVERSE
DOOR SWING AT BOTH DOORS
1/4" CLEAR TEMPERED GLASS
BLACK ANODIZED TYPE I ALUMINUM WINDOW
FRAME TO MATCH THE EXISTING WINDOW LAYOUT.
5" DIA. ROUND OPENINGS
EX
IST
ING
SIL
L H
EIG
HT
2' -
10"
4' -
6" 5' -
0"
07A02.01
________________
09A02.01
________________ 09A02.01
________________ 09A02.01
________________07A02.01
________________
EXISTING WALL TO REMAIN
EXISTING CARD READERS
TO REMAIN
C1
C1
C2
C3
C3
C3
75cd
(EXISTING)
15cd
15cd
CLEAR 1/4" CLEAR TEMPERED GLASS
ANODIZED ALUMINUM WINDOW FRAME
5" DIA. ROUND OPENING
SOLID SURFACE TRANSACTION SURFACE
3" SLOT
MA
TC
H E
XIS
TIN
G D
OO
R H
EIG
HT
S3"
2' -
10"
4' -
6"
3' - 0"
07A02.01
________________
1' - 0" ±
3 1/2" 3 1/2"
3"
WALL ASSEMBLY. PROVIDE
BLOCKING AS NECESSARY
SOLID SURFACE TRANSACTION
TOP PER FINISH SCHEDULE
BLACK ANODIZED ALUMINUM
WINDOW FRAME
1/4" CLEAR TEMPERED GLASS.
POLISH ALL EXPOSED EDGES
WALL ASSEMBLY. PROVIDE
BLOCKING AS NECESSARY
FINISH CURVED GYPSUM BOARD EDGES
WITH CORNER BEAD OR "L" BEAD.
BLACK ANODIZED TYPE I ALUMINUM
WINDOW FRAME
1/4" CLEAR TEMPERED GLASS
BLACK ANODIZED TYPE II ALUMINUM DOOR
FRAME TO MATCH EXISTING DOOR FRAMES
3' - 0"
MA
TC
H E
XIS
TIN
G D
OO
RS
HARDWARE SET 1 PER HARDWARE SCHEDULE
11A02.01
________________
FLUSH PANEL WOOD VENEER DOOR TO MATCH
EXISTING DOORS.
CARD READER BY OWNER. HEIGHT TO MATCH
EXISTING CARD READERS.
2' - 0"
2' -
10"
3"
4' -
6"
5" DIA. ROUND OPENING
1/4" CLEAR TEMPERED GLASS
3" SLOT
SOLID SURFACE TRANSACTION SURFACE
4" 4"
10" ±
1/4" CLEAR TEMPERED GLASS.
POLISH ALL EXPOSED EDGES
SOLID SURFACE TRANSACTION TOP
3"
5/8" GYPSUM BOARD BOTH SIDES.
FINISHED TO MATCH EXISTING WALLS
2-1/2" METAL STUDS 16" O.C.
ASSEMBLY TO ALLOW <L/240 DEFLECTION AT 10PSF.
BOTTOM "C" TRACK FASTENED TO THE FLOOR
EXISTING CEILING ASSEMBLY
TOP "C" TRACK FASTENED TO THE CEILING GRID
FINISH GYPSUM BOARD ON BOTH SIDES WITH TEAR-AWAY BEAD
WALL BASE PER FINISH SCHEDULE
NEW NON - RATED PARTITION
EXISTING PARTITION TO REMAIN
AREA NOT IN CONTRACT
ITEM TO REMOVE
B MAINTAIN THE INTEGRITY OF ALL FIRE-RATEDSYSTEMS.
E REPAIR WALLS & FINISHES AT ALL ITEMSAFFECTED BY CONSTRUCTION. ALL FINISHES &EXPOSED SURFACES ARE TO MATCH EXISTING,UNLESS NOTED OTHERWISE.
C ALL DIMENSIONS AND ALIGNMENTS ARE TOFINISHED FACE OF WALL, INCLUDING FINISHEDFACE OF MILLWORK PANELING WHERE OCCURS
D PROVIDE FIRE RETARDANT TREATED 3/4"PLYWOOD BLOCKING AS REQUIRED FOR : WALLHUNG MILLWORK, EQUIPMENT, WALL HUNGSCREEN DISPLAYS, ARTWORK AND PRIVATEOFFICE FURNITURE OVERHEADS
A DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONSGOVERN. IN CASE OF CONFLICT, NOTIFYARCHITECT PRIOR TO PARTITION INSTALLATION.
F ALL WORK IS TO COMPLY WITH THEACCESSIBILITY REFERENCE DETAILS ON A00.04UNLESS NOTED OTHERWISE.
G NO ELECTRICAL LOAD 120 VOLTS OR HIGHER ISTO BE ADDED UNLESS OTHERWISE NOTED.
H ACCESS CONTROL EQUIPMENT & SECURITYCAMERAS BY THE SECURITY CONTRACTOR ARELOW-VOLTAGE TO BE CONNECTED TO THEEXISTING BUILDING ACCESS CONTROL SYSTEM.
CR CARD READER, BY OWNER TO BE CONNECTED
TO THE EXISTING ACCESS CONTROL SYSTEM.
PROVIDE BACK-BOXES & CONDUIT WITH
PULL-STRINGS AS NECESSARY FOR THE CARD
READER, THE DOOR CONTACT, & THE
ELECTRIC STRIKE TO THE CEILING FOR THE
SECURITY CONTRACTOR.
C1 RELOCATE THE EXISTING LIGHT FIXTURE AS
SHOWN.
CONSTRUCTION PLAN NOTES
REFLECTED CEILING PLAN NOTES
01 PROVIDE A NEW WALL ASSEMBLY PER
10/A02.01. PROVIDE A NEW DOOR & WINDOW
AS SHOWN. MAINTAIN 60" WIDE CLEARANCE
AT THE WALL AS SHOWN FOR PARALLEL
APPROACH AT THE TRANSACTION SURFACE.
C2 4-WAY CEILING MOUNTED SECURITY CAMERA,
BY OWNER
02 REMOVE THE WINDOW ASSEMBLY &
TRANSACTION SURFACE FROM THE EXISTING
WALL & REPLACE AS SHOWN.
03 INTERCHANGE (2) EXISTING DOORS TO SWING
AS SHOWN. RELOCATE AS NECESSARY TO
MAINTAIN THE FOLLOWING MANEUVERING
CLEARANCES: 18" ON THE PULL SIDE & 12" ON
THE PUSH SIDE AT A DISTANCE 8" FROM THE
FACE OF THE DOOR TO COMPLY WITH ICC
A117.1 404.2.3.5.
C3 EXISTING EXIT SIGNS ARE TO REMAIN
04 EXISTING WALL ASSEMBLY & WORKSURFACE
ARE TO REMAIN. PROVIDE WALL SUPPORTS
UNDERNEATH THE WORKSURFACE AT EACH
END. FINISH THE SUPPORTS & REPAIR THE
WORKSURFACE AS NECESSARY TO MATCH
EXISTING.
EXISTING LIGHT SWITCHES ARE TO REMAIN
WALL MOUNTED VISUAL FIRE ALARM STROBE
TO BE 80" AFF TO THE BOTTOM OF THE DEVICE.
CONNECT TO THE EXISTING BUILDING FIRE
ALARM SYSTEM.
F
SHEET NOTES
GENERAL NOTES
LEGEND
© Ossa Studio
Date Description
Client
Project Number
Description
Scale
2021
Project Name
1515 MOCKINGBIRD LANE SUITE 7127
CHARLOTTE NC
704.890.2053
WWW.OSSASTUDIO.COM
PROJECT TEAM
As indicated
10/4
/202
1 5:
50:5
6 P
MZ
:\Sha
red\
3 -
Pro
ject
s\21
0 15.
00\3
.2 -
Des
ign \
3.2a
- B
IM\a
- C
e ntr
al M
odel
File
\21 0
15.0
0_S
E H
ealt h
Cas
h S
tatio
ns.r
v t
A02.01
CLINIC A
21015.00
MECKLENBURG COUNTY
249 BILLINGSLEY ROAD,CHARLOTTE NC 28211
9/10/2021 ISSUED FOR CONSTRUCTION
10/4/2021
SE HEALTH CASHSTATIONS
SCALE: 3/8" = 1'-0"
CLINIC A01SCALE: 3/8" = 1'-0"
CLINIC A - DEMOLITION02SCALE: 3/4" = 1'-0"
CLINIC A LOBBY03
SCALE: 3/16" = 1'-0"
CLINIC A - RCP04SCALE: 3/4" = 1'-0"
TRANSACTION WINDOW06
SCALE: 3" = 1'-0"
WINDOW SECTION07SCALE: 3" = 1'-0"
WINDOW SECTION09
SCALE: 3/4" = 1'-0"
DOOR WITH WINDOW08
SCALE: 3" = 1'-0"
DOOR SECTION11
SCALE: 3" = 1'-0"
WALL SECTION10
1 9/15/2021 ELECTRICAL REVISIONS
2 9/22/2021 DOOR REVISION
4 10/4/2021 FIRE ALARM REVISIONS
1
1
1
1
1
1
2
4
4
4
4
F
A02.02 03
A02.01
08
A02.01
06
CR 01ALIGN
01
5' -
0"
MIN
.
18"
MIN
.
02
02
03
04
04
A02.0205
12"
MIN
.(
> 1
2" )
A02.02
00
00
02
02
03
A02.02A02.0206
MA
TC
H E
XIS
TIN
G D
OO
R H
EIG
HT
S3"
2' -
10"
REPLACE LATCH PER
HARDWARE SET 2
1/4" CLEAR TEMPERED GLASS
BLACK ANODIZED TYPE II ALUMINUM WINDOW FRAME
5" DIA. ROUND OPENINGS
07A02.01
________________
07A02.01
________________
REVERSE DOOR SWING AS NOTED.
REPLACE LATCH PER HARDWARE SET 2
EXISTING WALL ASSEMBLY
MA
TC
H E
XIS
TIN
G D
OO
R H
EIG
HT
S3"
EX
IST
ING
SIL
L H
EIG
HT
4' -
8"
4' -
2"
C1
C1
C2
C3
75cd
(EXISTING)
C4
C4
NEW NON - RATED PARTITION
EXISTING PARTITION TO REMAIN
AREA NOT IN CONTRACT
ITEM TO REMOVE
B MAINTAIN THE INTEGRITY OF ALL FIRE-RATEDSYSTEMS.
E REPAIR WALLS & FINISHES AT ALL ITEMSAFFECTED BY CONSTRUCTION. ALL FINISHES &EXPOSED SURFACES ARE TO MATCH EXISTING,UNLESS NOTED OTHERWISE.
C ALL DIMENSIONS AND ALIGNMENTS ARE TOFINISHED FACE OF WALL, INCLUDING FINISHEDFACE OF MILLWORK PANELING WHERE OCCURS
D PROVIDE FIRE RETARDANT TREATED 3/4"PLYWOOD BLOCKING AS REQUIRED FOR : WALLHUNG MILLWORK, EQUIPMENT, WALL HUNGSCREEN DISPLAYS, ARTWORK AND PRIVATEOFFICE FURNITURE OVERHEADS
A DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONSGOVERN. IN CASE OF CONFLICT, NOTIFYARCHITECT PRIOR TO PARTITION INSTALLATION.
F ALL WORK IS TO COMPLY WITH THEACCESSIBILITY REFERENCE DETAILS ON A00.04UNLESS NOTED OTHERWISE.
G NO ELECTRICAL LOAD 120 VOLTS OR HIGHER ISTO BE ADDED UNLESS OTHERWISE NOTED.
H ACCESS CONTROL EQUIPMENT & SECURITYCAMERAS BY THE SECURITY CONTRACTOR ARELOW-VOLTAGE TO BE CONNECTED TO THEEXISTING BUILDING ACCESS CONTROL SYSTEM.
CR CARD READER, BY OWNER TO BE CONNECTED
TO THE EXISTING ACCESS CONTROL SYSTEM.
PROVIDE BACK-BOXES & CONDUIT WITH
PULL-STRINGS AS NECESSARY FOR THE CARD
READER, THE DOOR CONTACT, & THE
ELECTRIC STRIKE TO THE CEILING FOR THE
SECURITY CONTRACTOR.
C1 PROVIDE A NEW 2x2 LAY-IN LIGHT FIXTURE IN
THIS LOCATION TO MATCH THE EXISTING
LIGHTING. FIXTURES ARE TO BE SWITCHED
WITH THE LIGHTING IN THE WAITING AREA.
PROVIDE LITHONIA, METALUX, PHILIPS, OR
APPROVED SIMILAR. ADDITIONAL LIGHTING
WILL ADD 128 WATTS. THE EXISTING LIGHTING
CIRCUIT IS NOT TO EXCEED 1800 WATTS
TOTAL.
CONSTRUCTION PLAN NOTES
REFLECTED CEILING PLAN NOTES
01 PROVIDE A NEW WALL ASSEMBLY PER
10/A02.01. PROVIDE A NEW DOOR & WINDOW
AS SHOWN. MAINTAIN 60" WIDE CLEARANCE
AT THE WALL AS SHOWN FOR PARALLEL
APPROACH AT THE TRANSACTION SURFACE.
C2 4-WAY CEILING MOUNTED SECURITY CAMERA,
BY OWNER
02 RECONFIGURE WINDOW OPENINGS &
PROVIDE NEW GLAZING & TRANSACTION
SURFACE AS SHOWN.
03 REVERSE THE SWING OF THE EXISTING DOOR
AS SHOWN. PROVIDED THE MANEUVERING
CLEARANCES SHOWN. REPAIR THE DOOR TO
MATCH EXISTING.
00 REMOVE THE EXISTING WALLS AT EACH END
OF THE WORKSURFACE. REVISE THE
MILLWORK PER 05/A02.02 & 06/A02.02.
04 REPLACE THE LOCKSET PER HARDWARE SET
2. REPAIR THE DOOR TO MATCH EXISTING.
C3 EXISTING EXIT SIGNS ARE TO REMAIN.
EXISTING LIGHT SWITCHES ARE TO REMAIN
C4 WALLS & DOORS IN THIS LOCATION ARE
PARTIAL HEIGHT. REFER TO 03/A02.02.
NEW WALLS
CUT THE BASE OFF THE EXISTING CABINET & REINSTALL
CUT THE EXISTING WORKSURFACE & REINSTALL.
PROVIDE SUPPORTS AS NECESSARY
NEW PLAM CABINET WITH (2) ADJUSTABLE SHELVES.
26"x54"x24". LAMINATE TO MATCH EXISTING MILLWORK.
EXISTING UPPER CABINET TO REMAIN.
CUT THE EXISTING WORKSURFACE & REINSTALL.
PROVIDE SUPPORTS AS NECESSARY.
REINSTALL EXISTING CABINET
1' - 4" 3' - 3" 2' - 2 1/2" 3' - 3" 1' - 4"
2' -
9 1
/4"
±
EX
IST
ING
RELOCATE CABINET
CUT THE EXISTING WORKSURFACE TO REINSTALL
REMOVE EXISTING CABINET & BASE
EXISTING UPPER CABINET TO REMAIN.
RELOCATE CABINET
EXISTING WALLS TO BE REMOVED
SHEET NOTES
GENERAL NOTES
KEY PLAN
© Ossa Studio
Date Description
Client
Project Number
Description
Scale
2021
Project Name
1515 MOCKINGBIRD LANE SUITE 7127
CHARLOTTE NC
704.890.2053
WWW.OSSASTUDIO.COM
PROJECT TEAM
As indicated
10/4
/202
1 5:
50:5
7 P
MZ
:\Sha
red\
3 -
Pro
ject
s\21
0 15.
00\3
.2 -
Des
ign \
3.2a
- B
IM\a
- C
e ntr
al M
odel
File
\21 0
15.0
0_S
E H
ealt h
Cas
h S
tatio
ns.r
v t
A02.02
CLINIC B
21015.00
MECKLENBURG COUNTY
249 BILLINGSLEY ROAD,CHARLOTTE NC 28211
9/10/2021 ISSUED FOR CONSTRUCTION
10/4/2021
SE HEALTH CASHSTATIONS
SCALE: 3/8" = 1'-0"
CLINIC B01SCALE: 3/8" = 1'-0"
CLINIC B - DEMOLITION02SCALE: 3/4" = 1'-0"
CLINIC B LOBBY03
SCALE: 3/16" = 1'-0"
CLINIC B - RCP04
DOOR HARDWARE SCHEDULE
SET QUAN. Description Finish COMMENT
1 1 CYLINDRICAL LOCKSET - STOREROOM ANSI F86 US26D FREE EGRESS
1 ELECTRIC STRIKE - FAIL SECURE - SECURITRON UNL US26D
3 5 KNUCKLE BALL-BEARING HINGE US26D
1 DOOR CLOSER - REGULAR ARM US26D PULL SIDE
1 WALL STOP ANSI A156.16 L02251 US26D
3 SILENCER GRAY
1 CARD READER BY SECURITY CONTRACTOR
1 PIR MOTION SENSOR BY SECURITY CONTRACTOR
1 DOOR POSITION SWITCH BY SECURITY CONTRACTOR
2 1 CYLINDRICAL LOCKSET - STOREROOM F86 US26D FREE EGRESS
1 2-3/4" T-STRIKE US26D
01 DOORS IN A PATH OF EGRESS ARE TO ALLOW FREE EGRESS & COMPLY WITH NCBC 1010.1.9.
02 DOORS THAT ARE ELECTRICALLY LOCKED ARE TO BE FAIL-SAFE & COMPLY WITH NCBC 1010.1.9.8.
03 DOORS ARE TO BE KEYED TO MATCH THE BUILDING MASTER-KEY SYSTEM
04 ALUMINUM DOOR & WINDOW FRAMES ARE TO BE FACTORY FINISHED BLACK TO MATCH EXISTING
05 NEW DOORS ARE TO BE WOOD VENEER, FACTORY FINISHED TO MATCH EXISTING
06 THE HINGE SIDE OF DOORS IS TO BE 6" FROM THE ADJACENT INTERIOR CORNER. CONFIRM DOORCLEARANCE ON THE STRIKE SIDE COMPLIES WITH THE MANEUVERING CLEARANCE IN THEACCESSIBILITY REQUIREMENTS.
07 DOORS ARE TO BE UNDERCUT NO MORE THAN 1/2" FROM FINISHED FLOOR.
08 EXISTING & NEW EXIT DOORS ARE TO BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY ORANY SPECIAL KNOWLEDGE OR ASSISTANCE.
09 DOOR CLOSERS ARE TO BE ADJUSTED SO THE DOOR WILL CLOSE FROM A POSITION OF 90 DEGREES TO12 DEGREES IN 5 SECONDS MINIMUM.
10 DOOR CLOSERS ARE TO BE ADJUSTED SO THE MAXIMUM FORCE TO OPEN DOORS IS AS FOLLOWS:INTERIOR 5 LBS. EXTERIOR 7.5LBS.
11 THE BOTTOM 10 INCHES OF DOORS ARE TO HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THEDOOR TO BE OPENED BY A WHEELCHAIR FOOTREST.
12 THRESHOLDS ARE TO BE NO MORE THAN 1/2" HIGH & COMPLY WITH THE FLOOR SURFACEREQUIREMENTS IN THE ACCESSIBILITY REQUIREMENTS.
13 DOORS & HARDWARE ARE TO MEET 2009 ICC A117.1 ACCESSIBILITY REQUIREMENTS.
14 HARDWARE IS TO BE ANSI GRADE-1: ASSA ABLOY, CORBIN RUSSWIN, MEDECO, NORTON, ROCKWOOD,SARGENT, SECURITRON, OR APPROVED SIMILAR.
MATERIAL SCHEDULE
TAG DESCRIPTION MANUFACTURER NAME
VCT-1 VINYL COMPOSITION TILE TARKETTJOHNSONITEARMSTRONG
MATCH EXISTING
RB-1 4" RESILIENT COVE BASE TARKETTJOHNSONITEARMSTRONG
MATCH EXISTING
P-1 WALL PAINT SHERWIN WILLIAMSBENJAMIN MOOREPPG
MATCH EXISTING
ACT-1 ACOUSTICAL CEILING TILE ARMSTRONGUSGCERTAINTEED
MATCH EXISTING AS NECESSARY
SS-1 SOLID SURFACE CORIANWILSONARTFORMICA
MATCH THE SOLID SURFACE ON THEPARTIAL HEIGHT WALL IN CLINIC B
1 9/15/2021 ELECTRICAL REVISIONS
2 9/22/2021 DOOR REVISION
4 10/4/2021 FIRE ALARM REVISIONS
5 10/4/2021 MILLWORK REVISIONS
1
1
1
1
1
1
1
2
4
4
4
4
SCALE: 3/4" = 1'-0"
CLINIC B DESK05
SCALE: 3/4" = 1'-0"
CLINIC B DESK - EXISTING06
5
5