application flow sizing and order code configuration

112
Print date: 29.04.2014 11:58 AM Applicator®: 10.16.05 / 133 - 1 / 7 -  Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: [email protected] TAG : LPG-Main Timestamp: --- Review number: --- Sales order number: Sizing Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Operating Conditions minimum nominal maximum Requested Flow 18 780 1 229 Nm3/h Pressure 1.2 bar_g Temperature 30 °C Density 4.0131 kg/m3 Viscosity 0.00845 cP Z-factor 0.9649 Sound Velocity 248.7 m/s Pressure (min/max) 1.2 1.2 bar_g Temp. (min/max) 30 30 °C Flowmeter : t-mass 65I Flow Principle Thermal (t-mass) Meter Size DN 150 Minimum Flow 17.108  Nm3/h Calibrated Flow 1 710.824  Nm3/h Maximum Flow 3 421.65  Nm3/h Material (sensor) * SS 1.4404 / 316L Process connection* G 1 A ISO 228 / 1.4404 /316L Thread PED category ** : Application meets PED (Art.3.3)  Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65I 65I-20AB 1 Accessory Mounting boss - DK6MB DK6MB-B *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

Upload: muhammad-sarfraz

Post on 18-Jul-2015

92 views

Category:

Documents


12 download

TRANSCRIPT

Page 1: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:58 AMApplicator®: 10.16.05 / 133

- 1 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-MainTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 18 780 1 229 Nm3/hPressure 1.2 bar_gTemperature 30 °CDensity 4.0131 kg/m3Viscosity 0.00845 cPZ-factor 0.9649Sound Velocity 248.7 m/sPressure (min/max) 1.2 1.2 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65IFlow Principle Thermal (t-mass)Meter Size DN 150Minimum Flow 17.108   Nm3/hCalibrated Flow 1 710.824   Nm3/hMaximum Flow 3 421.65   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* G 1 A ISO 228 / 1.4404 /316L ThreadPED category ** : Application meets PED (Art.3.3)

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65I 65I-20AB

1 Accessory Mounting boss - DK6MB DK6MB-B

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 2: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:58 AMApplicator®: 10.16.05 / 133

- 2 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-MainTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 18 780 1 229 Nm3/hPressure loss 9.08E-6 0.01 0.04 mbarVelocity (meas. tube) 0.127 5.52 8.697 m/sMeasured error Mass*** 14.3 1.5 1.5 %Reynolds No. 9 574 414 858 653 668***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 3: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:58 AMApplicator®: 10.16.05 / 133

- 3 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-MainTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Propane (Gas) State GasChemical formula CH3-CH2-CH3 Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Propane (Gas) 100   Mole% 100   Mass%2    0   Mole% 0   Mass%3    0   Mole% 0   Mass%4    0   Mole% 0   Mass%5    0   Mole% 0   Mass%6    0   Mole% 0   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) 96.69   °CPc (Critical pressure) 42.47   barRho_c (Critical density) 217   kg/m3

Tm (Melting point) -187.7   °CTb (Boiling point) -42.11   °C

Calculated resultsDensity nom. 4.0131   kg/m3Molar mass 44.096   kg/kmolZ-factor nom. 0.9649Viscosity nom. 0.00845   cPSound velocity nom. 248.7   m/sThermal capacity nom. 1.742   kJ/(kg*K)Heat conductivity nom. 0.018   W/(m K)Vapor pressure nom. 10.815   bar_a

Pressure nom. 1.2   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 2.0122   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 1.9005   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 4: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:58 AMApplicator®: 10.16.05 / 133

- 4 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-MainTimestamp: --- Review number: ---Sales order number:

Installation sheetFlowmeter / Accessories

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65I 65I-20AB

1 Accessory Mounting boss - DK6MB DK6MB-B

Installation data :Insertion depth X (scale value) 160.49   mmInsertion tube length 235   mmPipe inner diameter 20°C 158.3   mmDuct Installation HorizontalDuct internal height  Duct internal width  Wall thickness 5   mmC1 = Height process connection 60   mmC2 = Height sensor connection 46   mmC3 = Height ball valve 0   mmC = Total height of connection 106   mmA= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation)B= Wall thicknessC= Height of connection

*The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to applicationdata. Endress + Hauser takes no liability for the suitability of the pipe dimensions.Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 5: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:58 AMApplicator®: 10.16.05 / 133

- 5 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-MainTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65I t-mass 65I t-mass 65IFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 100 DN 150 DN 200Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316LMinimum Flow 7.427 17.108 29.85 Nm3/hCalibrated Flow 742.698 1 710.824 2 985.049 Nm3/hMaximum Flow 1 485.4 3 421.65 5 970.1 Nm3/hPressure loss at req. Flow min. 6.42E-5 9.08E-6 2.49E-6 mbarPressure loss at req. Flow nom. 0.11 0.01 4.14E-3 mbarPressure loss at req. Flow max. 0.27 0.04 0.01 mbarVelocity (meas. tube) at req. Flow min. 0.293 0.127 0.073 m/sVelocity (meas. tube) at req. Flow nom. 12.72 5.52 3.164 m/sVelocity (meas. tube) at req. Flow max. 20.03 8.697 4.985 m/sMeas. error Mass at req. Flow min.*** 6.19 14.3 n.a. %Meas. error Mass at req. Flow nom.*** 1.85 1.5 1.5 %Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %Reynolds No. 629 646 414 858 314 070*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 6: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:58 AMApplicator®: 10.16.05 / 133

- 6 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-MainTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65IFlow Principle Thermal (t-mass)Meter Size DN 150Minimum Flow 17.108   Nm3/hCalibrated Flow 1 710.824   Nm3/hMaximum Flow 3 421.65   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 7: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:58 AMApplicator®: 10.16.05 / 133

- 7 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-MainTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Propane (Gas) Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C(M) CF3M - A 351 A A A(P) EPDM U U U(M) Alloy C22/2.4602 A A A(P) Kalrez A A A(P) PEEK C C C(P) PVDF A A A(M) Stainless steel 316L/316/1.4404 A A A(P) Viton A A A*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 8: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 12:00 PMApplicator®: 10.16.05 / 133

- 1 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KHXTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 18 780 1 229 Nm3/hPressure 1.2 bar_gTemperature 30 °CDensity 4.0131 kg/m3Viscosity 0.00845 cPZ-factor 0.9649Sound Velocity 248.7 m/sPressure (min/max) 1.2 1.2 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65IFlow Principle Thermal (t-mass)Meter Size DN 150Minimum Flow 17.108   Nm3/hCalibrated Flow 1 710.824   Nm3/hMaximum Flow 3 421.65   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* G 1 A ISO 228 / 1.4404 /316L ThreadPED category ** : Application meets PED (Art.3.3)

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65I 65I-20AB

1 Accessory Mounting boss - DK6MB DK6MB-B

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 9: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 12:00 PMApplicator®: 10.16.05 / 133

- 2 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KHXTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 18 780 1 229 Nm3/hPressure loss 9.08E-6 0.01 0.04 mbarVelocity (meas. tube) 0.127 5.52 8.697 m/sMeasured error Mass*** 14.3 1.5 1.5 %Reynolds No. 9 574 414 858 653 668***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 10: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 12:00 PMApplicator®: 10.16.05 / 133

- 3 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KHXTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Propane (Gas) State GasChemical formula CH3-CH2-CH3 Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Propane (Gas) 100   Mole% 100   Mass%2    0   Mole% 0   Mass%3    0   Mole% 0   Mass%4    0   Mole% 0   Mass%5    0   Mole% 0   Mass%6    0   Mole% 0   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) 96.69   °CPc (Critical pressure) 42.47   barRho_c (Critical density) 217   kg/m3

Tm (Melting point) -187.7   °CTb (Boiling point) -42.11   °C

Calculated resultsDensity nom. 4.0131   kg/m3Molar mass 44.096   kg/kmolZ-factor nom. 0.9649Viscosity nom. 0.00845   cPSound velocity nom. 248.7   m/sThermal capacity nom. 1.742   kJ/(kg*K)Heat conductivity nom. 0.018   W/(m K)Vapor pressure nom. 10.815   bar_a

Pressure nom. 1.2   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 2.0122   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 1.9005   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 11: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 12:00 PMApplicator®: 10.16.05 / 133

- 4 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KHXTimestamp: --- Review number: ---Sales order number:

Installation sheetFlowmeter / Accessories

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65I 65I-20AB

1 Accessory Mounting boss - DK6MB DK6MB-B

Installation data :Insertion depth X (scale value) 160.49   mmInsertion tube length 235   mmPipe inner diameter 20°C 158.3   mmDuct Installation HorizontalDuct internal height  Duct internal width  Wall thickness 5   mmC1 = Height process connection 60   mmC2 = Height sensor connection 46   mmC3 = Height ball valve 0   mmC = Total height of connection 106   mmA= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation)B= Wall thicknessC= Height of connection

*The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to applicationdata. Endress + Hauser takes no liability for the suitability of the pipe dimensions.Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 12: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 12:00 PMApplicator®: 10.16.05 / 133

- 5 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KHXTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65I t-mass 65I t-mass 65IFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 100 DN 150 DN 200Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316LMinimum Flow 7.427 17.108 29.85 Nm3/hCalibrated Flow 742.698 1 710.824 2 985.049 Nm3/hMaximum Flow 1 485.4 3 421.65 5 970.1 Nm3/hPressure loss at req. Flow min. 6.42E-5 9.08E-6 2.49E-6 mbarPressure loss at req. Flow nom. 0.11 0.01 4.14E-3 mbarPressure loss at req. Flow max. 0.27 0.04 0.01 mbarVelocity (meas. tube) at req. Flow min. 0.293 0.127 0.073 m/sVelocity (meas. tube) at req. Flow nom. 12.72 5.52 3.164 m/sVelocity (meas. tube) at req. Flow max. 20.03 8.697 4.985 m/sMeas. error Mass at req. Flow min.*** 6.19 14.3 n.a. %Meas. error Mass at req. Flow nom.*** 1.85 1.5 1.5 %Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %Reynolds No. 629 646 414 858 314 070*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 13: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 12:00 PMApplicator®: 10.16.05 / 133

- 6 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KHXTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65IFlow Principle Thermal (t-mass)Meter Size DN 150Minimum Flow 17.108   Nm3/hCalibrated Flow 1 710.824   Nm3/hMaximum Flow 3 421.65   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 14: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 12:00 PMApplicator®: 10.16.05 / 133

- 7 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KHXTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Propane (Gas) Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C(M) CF3M - A 351 A A A(P) EPDM U U U(M) Alloy C22/2.4602 A A A(P) Kalrez A A A(P) PEEK C C C(P) PVDF A A A(M) Stainless steel 316L/316/1.4404 A A A(P) Viton A A A*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 15: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:05 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KKTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 7 80 99 Nm3/hPressure 1.2 bar_gTemperature 30 °CDensity 4.0131 kg/m3Viscosity 0.00845 cPZ-factor 0.9649Sound Velocity 248.7 m/sPressure (min/max) 1.2 1.2 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 40Minimum Flow 1.162   Nm3/hCalibrated Flow 116.23   Nm3/hMaximum Flow 232.46   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* PN 40 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application is Cat. II

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65F 65F40-AE**GP

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 16: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:05 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KKTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 7 80 99 Nm3/hPressure loss 4.21E-3 0.45 0.68 mbarVelocity (meas. tube) 0.855 9.773 12.09 m/sMeasured error Mass*** 2.49 1.5 1.5 %Reynolds No. 15 469 176 787 218 774***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 17: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:05 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KKTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Propane (Gas) State GasChemical formula CH3-CH2-CH3 Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Propane (Gas) 100   Mole% 100   Mass%2    0   Mole% 0   Mass%3    0   Mole% 0   Mass%4    0   Mole% 0   Mass%5    0   Mole% 0   Mass%6    0   Mole% 0   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) 96.69   °CPc (Critical pressure) 42.47   barRho_c (Critical density) 217   kg/m3

Tm (Melting point) -187.7   °CTb (Boiling point) -42.11   °C

Calculated resultsDensity nom. 4.0131   kg/m3Molar mass 44.096   kg/kmolZ-factor nom. 0.9649Viscosity nom. 0.00845   cPSound velocity nom. 248.7   m/sThermal capacity nom. 1.742   kJ/(kg*K)Heat conductivity nom. 0.018   W/(m K)Vapor pressure nom. 10.815   bar_a

Pressure nom. 1.2   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 2.0122   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 1.9005   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 18: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:05 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KKTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65F t-mass 65F t-mass 65FFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 25 DN 40 DN 50Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 40 EN 1092-1B1 / 1.4404/316L

PN 40 EN 1092-1B1 / 1.4404/316L

Minimum Flow 0.419 1.162 1.906 Nm3/hCalibrated Flow 41.885 116.23 190.575 Nm3/hMaximum Flow 83.769 232.46 381.151 Nm3/hPressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbarPressure loss at req. Flow nom. 3.71 0.45 0.13 mbarPressure loss at req. Flow max. 5.7 0.68 0.21 mbarVelocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/sVelocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/sVelocity (meas. tube) at req. Flow max. 29.73 12.09 7.253 m/sMeas. error Mass at req. Flow min.*** 1.5 2.49 4.08 %Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %Reynolds No. 277 185 176 787 136 902*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 19: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:05 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KKTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 40Minimum Flow 1.162   Nm3/hCalibrated Flow 116.23   Nm3/hMaximum Flow 232.46   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 20: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:05 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-KKTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Propane (Gas) Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C(M) CF3M - A 351 A A A(P) EPDM U U U(M) Alloy C22/2.4602 A A A(P) Kalrez A A A(P) PEEK C C C(P) PVDF A A A(M) Stainless steel 316L/316/1.4404 A A A(P) Viton A A A*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 21: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:16 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-BoilerTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 20 420 448 Nm3/hPressure 1.2 bar_gTemperature 30 °CDensity 4.0131 kg/m3Viscosity 0.00845 cPZ-factor 0.9649Sound Velocity 248.7 m/sPressure (min/max) 1.2 1.2 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 80Minimum Flow 4.48   Nm3/hCalibrated Flow 448.013   Nm3/hMaximum Flow 896.026   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* PN 40 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application is Cat. II

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65F 65F80-AE**GP

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 22: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:16 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-BoilerTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 20 420 448 Nm3/hPressure loss 1.64E-3 0.52 0.6 mbarVelocity (meas. tube) 0.594 12.46 13.3 m/sMeasured error Mass*** 3.36 1.5 1.5 %Reynolds No. 21 784 457 463 487 961***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 23: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:16 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-BoilerTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Propane (Gas) State GasChemical formula CH3-CH2-CH3 Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Propane (Gas) 100   Mole% 100   Mass%2    0   Mole% 0   Mass%3    0   Mole% 0   Mass%4    0   Mole% 0   Mass%5    0   Mole% 0   Mass%6    0   Mole% 0   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) 96.69   °CPc (Critical pressure) 42.47   barRho_c (Critical density) 217   kg/m3

Tm (Melting point) -187.7   °CTb (Boiling point) -42.11   °C

Calculated resultsDensity nom. 4.0131   kg/m3Molar mass 44.096   kg/kmolZ-factor nom. 0.9649Viscosity nom. 0.00845   cPSound velocity nom. 248.7   m/sThermal capacity nom. 1.742   kJ/(kg*K)Heat conductivity nom. 0.018   W/(m K)Vapor pressure nom. 10.815   bar_a

Pressure nom. 1.2   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 2.0122   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 1.9005   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 24: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:16 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-BoilerTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65F t-mass 65F t-mass 65FFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 50 DN 80 DN 100Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 40 EN 1092-1B1 / 1.4404/316L

PN 16 EN 1092-1B1 / 1.4404/316L

Minimum Flow 1.906 4.48 7.853 Nm3/hCalibrated Flow 190.575 448.013 785.338 Nm3/hMaximum Flow 381.151 896.026 1 570.68 Nm3/hPressure loss at req. Flow min. 9.29E-3 1.64E-3 6.5E-4 mbarPressure loss at req. Flow nom. 3.7 0.52 0.18 mbarPressure loss at req. Flow max. 4.21 0.6 0.21 mbarVelocity (meas. tube) at req. Flow min. 1.465 0.594 0.369 m/sVelocity (meas. tube) at req. Flow nom. 30.77 12.46 7.755 m/sVelocity (meas. tube) at req. Flow max. 32.82 13.3 8.272 m/sMeas. error Mass at req. Flow min.*** 1.5 3.36 5.89 %Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %Reynolds No. 718 738 457 463 360 836*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 25: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:16 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-BoilerTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 80Minimum Flow 4.48   Nm3/hCalibrated Flow 448.013   Nm3/hMaximum Flow 896.026   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 26: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:16 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-BoilerTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Propane (Gas) Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C(M) CF3M - A 351 A A A(P) EPDM U U U(M) Alloy C22/2.4602 A A A(P) Kalrez A A A(P) PEEK C C C(P) PVDF A A A(M) Stainless steel 316L/316/1.4404 A A A(P) Viton A A A*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 27: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:09 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-CanteenTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 7 80 94 Nm3/hPressure 1.2 bar_gTemperature 30 °CDensity 4.0131 kg/m3Viscosity 0.00845 cPZ-factor 0.9649Sound Velocity 248.7 m/sPressure (min/max) 1.2 1.2 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 40Minimum Flow 1.162   Nm3/hCalibrated Flow 116.23   Nm3/hMaximum Flow 232.46   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* PN 40 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application is Cat. II

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65F 65F40-AE**GP

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 28: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:09 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-CanteenTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 7 80 94 Nm3/hPressure loss 4.21E-3 0.45 0.62 mbarVelocity (meas. tube) 0.855 9.773 11.48 m/sMeasured error Mass*** 2.49 1.5 1.5 %Reynolds No. 15 469 176 787 207 725***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 29: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:09 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-CanteenTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Propane (Gas) State GasChemical formula CH3-CH2-CH3 Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Propane (Gas) 100   Mole% 100   Mass%2    0   Mole% 0   Mass%3    0   Mole% 0   Mass%4    0   Mole% 0   Mass%5    0   Mole% 0   Mass%6    0   Mole% 0   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) 96.69   °CPc (Critical pressure) 42.47   barRho_c (Critical density) 217   kg/m3

Tm (Melting point) -187.7   °CTb (Boiling point) -42.11   °C

Calculated resultsDensity nom. 4.0131   kg/m3Molar mass 44.096   kg/kmolZ-factor nom. 0.9649Viscosity nom. 0.00845   cPSound velocity nom. 248.7   m/sThermal capacity nom. 1.742   kJ/(kg*K)Heat conductivity nom. 0.018   W/(m K)Vapor pressure nom. 10.815   bar_a

Pressure nom. 1.2   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 2.0122   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 1.9005   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 30: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:09 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-CanteenTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65F t-mass 65F t-mass 65FFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 25 DN 40 DN 50Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 40 EN 1092-1B1 / 1.4404/316L

PN 40 EN 1092-1B1 / 1.4404/316L

Minimum Flow 0.419 1.162 1.906 Nm3/hCalibrated Flow 41.885 116.23 190.575 Nm3/hMaximum Flow 83.769 232.46 381.151 Nm3/hPressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbarPressure loss at req. Flow nom. 3.71 0.45 0.13 mbarPressure loss at req. Flow max. 5.14 0.62 0.19 mbarVelocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/sVelocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/sVelocity (meas. tube) at req. Flow max. 28.23 11.48 6.887 m/sMeas. error Mass at req. Flow min.*** 1.5 2.49 4.08 %Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %Reynolds No. 277 185 176 787 136 902*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 31: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:09 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-CanteenTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 40Minimum Flow 1.162   Nm3/hCalibrated Flow 116.23   Nm3/hMaximum Flow 232.46   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 32: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:09 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-CanteenTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Propane (Gas) Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C(M) CF3M - A 351 A A A(P) EPDM U U U(M) Alloy C22/2.4602 A A A(P) Kalrez A A A(P) PEEK C C C(P) PVDF A A A(M) Stainless steel 316L/316/1.4404 A A A(P) Viton A A A*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 33: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:10 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-SchaffTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 7 80 94 Nm3/hPressure 1.2 bar_gTemperature 30 °CDensity 4.0131 kg/m3Viscosity 0.00845 cPZ-factor 0.9649Sound Velocity 248.7 m/sPressure (min/max) 1.2 1.2 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 40Minimum Flow 1.162   Nm3/hCalibrated Flow 116.23   Nm3/hMaximum Flow 232.46   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* PN 40 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application is Cat. II

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65F 65F40-AE**GP

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 34: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:10 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-SchaffTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 7 80 94 Nm3/hPressure loss 4.21E-3 0.45 0.62 mbarVelocity (meas. tube) 0.855 9.773 11.48 m/sMeasured error Mass*** 2.49 1.5 1.5 %Reynolds No. 15 469 176 787 207 725***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 35: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:10 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-SchaffTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Propane (Gas) State GasChemical formula CH3-CH2-CH3 Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Propane (Gas) 100   Mole% 100   Mass%2    0   Mole% 0   Mass%3    0   Mole% 0   Mass%4    0   Mole% 0   Mass%5    0   Mole% 0   Mass%6    0   Mole% 0   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) 96.69   °CPc (Critical pressure) 42.47   barRho_c (Critical density) 217   kg/m3

Tm (Melting point) -187.7   °CTb (Boiling point) -42.11   °C

Calculated resultsDensity nom. 4.0131   kg/m3Molar mass 44.096   kg/kmolZ-factor nom. 0.9649Viscosity nom. 0.00845   cPSound velocity nom. 248.7   m/sThermal capacity nom. 1.742   kJ/(kg*K)Heat conductivity nom. 0.018   W/(m K)Vapor pressure nom. 10.815   bar_a

Pressure nom. 1.2   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 2.0122   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 1.9005   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 36: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:10 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-SchaffTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Propane (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65F t-mass 65F t-mass 65FFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 25 DN 40 DN 50Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 40 EN 1092-1B1 / 1.4404/316L

PN 40 EN 1092-1B1 / 1.4404/316L

Minimum Flow 0.419 1.162 1.906 Nm3/hCalibrated Flow 41.885 116.23 190.575 Nm3/hMaximum Flow 83.769 232.46 381.151 Nm3/hPressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbarPressure loss at req. Flow nom. 3.71 0.45 0.13 mbarPressure loss at req. Flow max. 5.14 0.62 0.19 mbarVelocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/sVelocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/sVelocity (meas. tube) at req. Flow max. 28.23 11.48 6.887 m/sMeas. error Mass at req. Flow min.*** 1.5 2.49 4.08 %Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %Reynolds No. 277 185 176 787 136 902*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 37: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:10 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-SchaffTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 40Minimum Flow 1.162   Nm3/hCalibrated Flow 116.23   Nm3/hMaximum Flow 232.46   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 38: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 11:10 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : LPG-SchaffTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Propane (Gas) Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C(M) CF3M - A 351 A A A(P) EPDM U U U(M) Alloy C22/2.4602 A A A(P) Kalrez A A A(P) PEEK C C C(P) PVDF A A A(M) Stainless steel 316L/316/1.4404 A A A(P) Viton A A A*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 39: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 08:56 AMApplicator®: 10.16.05 / 133

- 1 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-MainTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 50 2 100 2 300 Nm3/hPressure 1.6 bar_gTemperature 30 °CDensity 1.7929 kg/m3Viscosity 0.01146 cPZ-factor 0.9955Sound Velocity 433.5 m/sPressure (min/max) 1.6 1.6 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65IFlow Principle Thermal (t-mass)Meter Size DN 150Minimum Flow 37.217   Nm3/hCalibrated Flow 3 721.665   Nm3/hMaximum Flow 7 443.33   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* G 1 A ISO 228 / 1.4404 /316L ThreadPED category ** : Application meets PED (Art.3.3)

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65I 65I-20AB

1 Accessory Mounting boss - DK6MB DK6MB-B

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 40: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 08:56 AMApplicator®: 10.16.05 / 133

- 2 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-MainTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 50 2 100 2 300 Nm3/hPressure loss 2.33E-5 0.03 0.04 mbarVelocity (meas. tube) 0.303 12.73 13.94 m/sMeasured error Mass*** 11.2 1.5 1.5 %Reynolds No. 7 504 315 151 345 165***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 41: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 08:56 AMApplicator®: 10.16.05 / 133

- 3 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-MainTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Natural Gas State GasChemical formula NASA-Langley Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass%2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass%3    Methane (Gas) 91.82   Mole% 85.5   Mass%4    Ethane (Gas) 4.85   Mole% 8.53   Mass%5    Propane (Gas) 0.26   Mole% 0.68   Mass%6    n-Butane (Gas) 0.06   Mole% 0.21   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) -77.57   °CPc (Critical pressure) 46.1041   barRho_c (Critical density) 168.8   kg/m3

Tm (Melting point) n.a.   °CTb (Boiling point) n.a.   °C

Calculated resultsDensity nom. 1.7929   kg/m3Molar mass 17.214   kg/kmolZ-factor nom. 0.9955Viscosity nom. 0.01146   cPSound velocity nom. 433.5   m/sThermal capacity nom. 2.153   kJ/(kg*K)Heat conductivity nom. 0.034   W/(m K)Vapor pressure nom.   bar_a

Pressure nom. 1.6   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 0.77   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 0.7296   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 42: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 08:56 AMApplicator®: 10.16.05 / 133

- 4 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-MainTimestamp: --- Review number: ---Sales order number:

Installation sheetFlowmeter / Accessories

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65I 65I-20AB

1 Accessory Mounting boss - DK6MB DK6MB-B

Installation data :Insertion depth X (scale value) 160.49   mmInsertion tube length 235   mmPipe inner diameter 20°C 158.3   mmDuct Installation HorizontalDuct internal height  Duct internal width  Wall thickness 5   mmC1 = Height process connection 60   mmC2 = Height sensor connection 46   mmC3 = Height ball valve 0   mmC = Total height of connection 106   mmA= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation)B= Wall thicknessC= Height of connection

*The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to applicationdata. Endress + Hauser takes no liability for the suitability of the pipe dimensions.Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 43: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 08:56 AMApplicator®: 10.16.05 / 133

- 5 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-MainTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65I t-mass 65I t-mass 65IFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 100 DN 150 DN 200Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316LMinimum Flow 16.156 37.217 64.936 Nm3/hCalibrated Flow 1 615.638 3 721.665 6 493.57 Nm3/hMaximum Flow 3 231.28 7 443.33 12 987.1 Nm3/hPressure loss at req. Flow min. 1.67E-4 2.33E-5 6.6E-6 mbarPressure loss at req. Flow nom. 0.26 0.03 9.66E-3 mbarPressure loss at req. Flow max. 0.31 0.04 0.01 mbarVelocity (meas. tube) at req. Flow min. 0.698 0.303 0.174 m/sVelocity (meas. tube) at req. Flow nom. 29.32 12.73 7.295 m/sVelocity (meas. tube) at req. Flow max. 32.11 13.94 7.99 m/sMeas. error Mass at req. Flow min.*** 4.85 11.2 n.a. %Meas. error Mass at req. Flow nom.*** 3.6 1.5 1.5 %Meas. error Mass at req. Flow max.*** 4.47 1.5 1.5 %Reynolds No. 478 316 315 151 238 586*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 44: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 08:56 AMApplicator®: 10.16.05 / 133

- 6 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-MainTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65IFlow Principle Thermal (t-mass)Meter Size DN 150Minimum Flow 37.217   Nm3/hCalibrated Flow 3 721.665   Nm3/hMaximum Flow 7 443.33   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 45: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 08:56 AMApplicator®: 10.16.05 / 133

- 7 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-MainTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Natural Gas Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 46: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:18 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KHXTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 84 1 050 1 150 Nm3/hPressure 1.6 bar_gTemperature 30 °CDensity 1.7929 kg/m3Viscosity 0.01146 cPZ-factor 0.9955Sound Velocity 433.5 m/sPressure (min/max) 1.6 1.6 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 100Minimum Flow 17.084   Nm3/hCalibrated Flow 1 708.397   Nm3/hMaximum Flow 3 416.79   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* PN 16 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application is Cat. II

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65F 65F1H-AB**GP

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 47: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:18 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KHXTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 84 1 050 1 150 Nm3/hPressure loss 3.6E-3 0.39 0.47 mbarVelocity (meas. tube) 1.328 16.61 18.19 m/sMeasured error Mass*** 3.05 1.5 1.5 %Reynolds No. 20 363 254 533 278 774***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 48: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:18 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KHXTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Natural Gas State GasChemical formula NASA-Langley Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass%2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass%3    Methane (Gas) 91.82   Mole% 85.5   Mass%4    Ethane (Gas) 4.85   Mole% 8.53   Mass%5    Propane (Gas) 0.26   Mole% 0.68   Mass%6    n-Butane (Gas) 0.06   Mole% 0.21   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) -77.57   °CPc (Critical pressure) 46.1041   barRho_c (Critical density) 168.8   kg/m3

Tm (Melting point) n.a.   °CTb (Boiling point) n.a.   °C

Calculated resultsDensity nom. 1.7929   kg/m3Molar mass 17.214   kg/kmolZ-factor nom. 0.9955Viscosity nom. 0.01146   cPSound velocity nom. 433.5   m/sThermal capacity nom. 2.153   kJ/(kg*K)Heat conductivity nom. 0.034   W/(m K)Vapor pressure nom.   bar_a

Pressure nom. 1.6   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 0.77   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 0.7296   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 49: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:18 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KHXTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65F t-mass 65FFlow Principle Thermal (t-mass) Thermal (t-mass)Meter Size DN 80 DN 100Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 16 EN 1092-1B1 / 1.4404/316L

Minimum Flow 9.746 17.084 Nm3/hCalibrated Flow 974.591 1 708.397 Nm3/hMaximum Flow 1 949.18 3 416.79 Nm3/hPressure loss at req. Flow min. 9.13E-3 3.6E-3 mbarPressure loss at req. Flow nom. 1.09 0.39 mbarPressure loss at req. Flow max. 1.31 0.47 mbarVelocity (meas. tube) at req. Flow min. 2.135 1.328 m/sVelocity (meas. tube) at req. Flow nom. 26.69 16.61 m/sVelocity (meas. tube) at req. Flow max. 29.23 18.19 m/sMeas. error Mass at req. Flow min.*** 1.74 3.05 %Meas. error Mass at req. Flow nom.*** 2.04 1.5 %Meas. error Mass at req. Flow max.*** 2.76 1.5 %Reynolds No. 322 693 254 533*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 50: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:18 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KHXTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 100Minimum Flow 17.084   Nm3/hCalibrated Flow 1 708.397   Nm3/hMaximum Flow 3 416.79   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 51: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:18 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KHXTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Natural Gas Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 52: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:22 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-Gas GensetTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 50 650 700 Nm3/hPressure 1.6 bar_gTemperature 30 °CDensity 1.7929 kg/m3Viscosity 0.01146 cPZ-factor 0.9955Sound Velocity 433.5 m/sPressure (min/max) 1.6 1.6 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 80Minimum Flow 9.746   Nm3/hCalibrated Flow 974.591   Nm3/hMaximum Flow 1 949.18   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* PN 40 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application is Cat. II

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65F 65F80-AE**GP

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 53: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:22 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-Gas GensetTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 50 650 700 Nm3/hPressure loss 3.68E-3 0.42 0.49 mbarVelocity (meas. tube) 1.271 16.52 17.79 m/sMeasured error Mass*** 2.92 1.5 1.5 %Reynolds No. 15 366 199 763 215 129***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 54: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:22 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-Gas GensetTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Natural Gas State GasChemical formula NASA-Langley Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass%2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass%3    Methane (Gas) 91.82   Mole% 85.5   Mass%4    Ethane (Gas) 4.85   Mole% 8.53   Mass%5    Propane (Gas) 0.26   Mole% 0.68   Mass%6    n-Butane (Gas) 0.06   Mole% 0.21   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) -77.57   °CPc (Critical pressure) 46.1041   barRho_c (Critical density) 168.8   kg/m3

Tm (Melting point) n.a.   °CTb (Boiling point) n.a.   °C

Calculated resultsDensity nom. 1.7929   kg/m3Molar mass 17.214   kg/kmolZ-factor nom. 0.9955Viscosity nom. 0.01146   cPSound velocity nom. 433.5   m/sThermal capacity nom. 2.153   kJ/(kg*K)Heat conductivity nom. 0.034   W/(m K)Vapor pressure nom.   bar_a

Pressure nom. 1.6   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 0.77   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 0.7296   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 55: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:22 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-Gas GensetTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65F t-mass 65F t-mass 65FFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 50 DN 80 DN 100Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 40 EN 1092-1B1 / 1.4404/316L

PN 16 EN 1092-1B1 / 1.4404/316L

Minimum Flow 4.146 9.746 17.084 Nm3/hCalibrated Flow 414.571 974.591 1 708.397 Nm3/hMaximum Flow 829.142 1 949.18 3 416.79 Nm3/hPressure loss at req. Flow min. 0.02 3.68E-3 1.45E-3 mbarPressure loss at req. Flow nom. 2.93 0.42 0.15 mbarPressure loss at req. Flow max. 3.39 0.49 0.18 mbarVelocity (meas. tube) at req. Flow min. 3.137 1.271 0.791 m/sVelocity (meas. tube) at req. Flow nom. 40.79 16.52 10.28 m/sVelocity (meas. tube) at req. Flow max. 43.92 17.79 11.07 m/sMeas. error Mass at req. Flow min.*** 1.5 2.92 5.13 %Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %Reynolds No. 313 855 199 763 157 568*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 56: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:22 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-Gas GensetTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 80Minimum Flow 9.746   Nm3/hCalibrated Flow 974.591   Nm3/hMaximum Flow 1 949.18   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 57: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:22 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-Gas GensetTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Natural Gas Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 58: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:26 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KKTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 17 210 260 Nm3/hPressure 1.6 bar_gTemperature 30 °CDensity 1.7929 kg/m3Viscosity 0.01146 cPZ-factor 0.9955Sound Velocity 433.5 m/sPressure (min/max) 1.6 1.6 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 50Minimum Flow 4.146   Nm3/hCalibrated Flow 414.571   Nm3/hMaximum Flow 829.142   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* PN 40 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application is Cat. II

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65F 65F50-AE**GP

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 59: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:26 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KKTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 17 210 260 Nm3/hPressure loss 3.11E-3 0.31 0.48 mbarVelocity (meas. tube) 1.067 13.18 16.31 m/sMeasured error Mass*** 3.66 1.5 1.5 %Reynolds No. 8 209 101 399 125 542***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 60: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:26 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KKTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Natural Gas State GasChemical formula NASA-Langley Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass%2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass%3    Methane (Gas) 91.82   Mole% 85.5   Mass%4    Ethane (Gas) 4.85   Mole% 8.53   Mass%5    Propane (Gas) 0.26   Mole% 0.68   Mass%6    n-Butane (Gas) 0.06   Mole% 0.21   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) -77.57   °CPc (Critical pressure) 46.1041   barRho_c (Critical density) 168.8   kg/m3

Tm (Melting point) n.a.   °CTb (Boiling point) n.a.   °C

Calculated resultsDensity nom. 1.7929   kg/m3Molar mass 17.214   kg/kmolZ-factor nom. 0.9955Viscosity nom. 0.01146   cPSound velocity nom. 433.5   m/sThermal capacity nom. 2.153   kJ/(kg*K)Heat conductivity nom. 0.034   W/(m K)Vapor pressure nom.   bar_a

Pressure nom. 1.6   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 0.77   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 0.7296   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 61: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:26 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KKTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65F t-mass 65F t-mass 65FFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 40 DN 50 DN 80Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 40 EN 1092-1B1 / 1.4404/316L

PN 40 EN 1092-1B1 / 1.4404/316L

Minimum Flow 2.528 4.146 9.746 Nm3/hCalibrated Flow 252.843 414.571 974.591 Nm3/hMaximum Flow 505.685 829.142 1 949.18 Nm3/hPressure loss at req. Flow min. 8.96E-3 3.11E-3 5.52E-4 mbarPressure loss at req. Flow nom. 1.02 0.31 0.04 mbarPressure loss at req. Flow max. 1.56 0.48 0.06 mbarVelocity (meas. tube) at req. Flow min. 1.779 1.067 0.432 m/sVelocity (meas. tube) at req. Flow nom. 21.97 13.18 5.338 m/sVelocity (meas. tube) at req. Flow max. 27.21 16.31 6.609 m/sMeas. error Mass at req. Flow min.*** 2.23 3.66 8.6 %Meas. error Mass at req. Flow nom.*** 1.5 1.5 1.5 %Meas. error Mass at req. Flow max.*** 1.7 1.5 1.5 %Reynolds No. 130 941 101 399 64 539*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 62: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:26 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KKTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 50Minimum Flow 4.146   Nm3/hCalibrated Flow 414.571   Nm3/hMaximum Flow 829.142   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 63: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:26 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-KKTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Natural Gas Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 64: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:29 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-BoilerTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 50 650 700 Nm3/hPressure 1.6 bar_gTemperature 30 °CDensity 1.7929 kg/m3Viscosity 0.01146 cPZ-factor 0.9955Sound Velocity 433.5 m/sPressure (min/max) 1.6 1.6 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 80Minimum Flow 9.746   Nm3/hCalibrated Flow 974.591   Nm3/hMaximum Flow 1 949.18   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* PN 40 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application is Cat. II

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65F 65F80-AE**GP

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 65: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:29 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-BoilerTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 50 650 700 Nm3/hPressure loss 3.68E-3 0.42 0.49 mbarVelocity (meas. tube) 1.271 16.52 17.79 m/sMeasured error Mass*** 2.92 1.5 1.5 %Reynolds No. 15 366 199 763 215 129***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 66: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:29 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-BoilerTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Natural Gas State GasChemical formula NASA-Langley Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass%2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass%3    Methane (Gas) 91.82   Mole% 85.5   Mass%4    Ethane (Gas) 4.85   Mole% 8.53   Mass%5    Propane (Gas) 0.26   Mole% 0.68   Mass%6    n-Butane (Gas) 0.06   Mole% 0.21   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) -77.57   °CPc (Critical pressure) 46.1041   barRho_c (Critical density) 168.8   kg/m3

Tm (Melting point) n.a.   °CTb (Boiling point) n.a.   °C

Calculated resultsDensity nom. 1.7929   kg/m3Molar mass 17.214   kg/kmolZ-factor nom. 0.9955Viscosity nom. 0.01146   cPSound velocity nom. 433.5   m/sThermal capacity nom. 2.153   kJ/(kg*K)Heat conductivity nom. 0.034   W/(m K)Vapor pressure nom.   bar_a

Pressure nom. 1.6   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 0.77   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 0.7296   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 67: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:29 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-BoilerTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65F t-mass 65F t-mass 65FFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 50 DN 80 DN 100Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 40 EN 1092-1B1 / 1.4404/316L

PN 16 EN 1092-1B1 / 1.4404/316L

Minimum Flow 4.146 9.746 17.084 Nm3/hCalibrated Flow 414.571 974.591 1 708.397 Nm3/hMaximum Flow 829.142 1 949.18 3 416.79 Nm3/hPressure loss at req. Flow min. 0.02 3.68E-3 1.45E-3 mbarPressure loss at req. Flow nom. 2.93 0.42 0.15 mbarPressure loss at req. Flow max. 3.39 0.49 0.18 mbarVelocity (meas. tube) at req. Flow min. 3.137 1.271 0.791 m/sVelocity (meas. tube) at req. Flow nom. 40.79 16.52 10.28 m/sVelocity (meas. tube) at req. Flow max. 43.92 17.79 11.07 m/sMeas. error Mass at req. Flow min.*** 1.5 2.92 5.13 %Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %Reynolds No. 313 855 199 763 157 568*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 68: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:29 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-BoilerTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 80Minimum Flow 9.746   Nm3/hCalibrated Flow 974.591   Nm3/hMaximum Flow 1 949.18   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 69: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:29 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-BoilerTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Natural Gas Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 70: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:33 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-CanteenTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 6 42 50 Nm3/hPressure 1.6 bar_gTemperature 30 °CDensity 1.7929 kg/m3Viscosity 0.01146 cPZ-factor 0.9955Sound Velocity 433.5 m/sPressure (min/max) 1.6 1.6 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 25Minimum Flow 0.911   Nm3/hCalibrated Flow 91.114   Nm3/hMaximum Flow 182.229   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* PN 40 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application meets PED (Art.3.3)

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65F 65F25-AE**G1

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 71: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:33 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-CanteenTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 6 42 50 Nm3/hPressure loss 9.53E-3 0.35 0.49 mbarVelocity (meas. tube) 1.543 10.8 12.86 m/sMeasured error Mass*** 2.28 1.5 1.5 %Reynolds No. 5 866 41 060 48 881***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 72: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:33 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-CanteenTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Natural Gas State GasChemical formula NASA-Langley Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass%2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass%3    Methane (Gas) 91.82   Mole% 85.5   Mass%4    Ethane (Gas) 4.85   Mole% 8.53   Mass%5    Propane (Gas) 0.26   Mole% 0.68   Mass%6    n-Butane (Gas) 0.06   Mole% 0.21   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) -77.57   °CPc (Critical pressure) 46.1041   barRho_c (Critical density) 168.8   kg/m3

Tm (Melting point) n.a.   °CTb (Boiling point) n.a.   °C

Calculated resultsDensity nom. 1.7929   kg/m3Molar mass 17.214   kg/kmolZ-factor nom. 0.9955Viscosity nom. 0.01146   cPSound velocity nom. 433.5   m/sThermal capacity nom. 2.153   kJ/(kg*K)Heat conductivity nom. 0.034   W/(m K)Vapor pressure nom.   bar_a

Pressure nom. 1.6   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 0.77   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 0.7296   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 73: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:33 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-CanteenTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65F t-mass 65F t-mass 65FFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 15 DN 25 DN 40Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 40 EN 1092-1B1 / 1.4404/316L

PN 40 EN 1092-1B1 / 1.4404/316L

Minimum Flow 0.241 0.911 2.528 Nm3/hCalibrated Flow 24.145 91.114 252.843 Nm3/hMaximum Flow 48.291 182.229 505.685 Nm3/hPressure loss at req. Flow min. 0.13 9.53E-3 1.43E-3 mbarPressure loss at req. Flow nom. 6.39 0.35 0.04 mbarPressure loss at req. Flow max. 9.03 0.49 0.06 mbarVelocity (meas. tube) at req. Flow min. 4.717 1.543 0.628 m/sVelocity (meas. tube) at req. Flow nom. 33.02 10.8 4.395 m/sVelocity (meas. tube) at req. Flow max. 39.31 12.86 5.232 m/sMeas. error Mass at req. Flow min.*** 1.5 2.28 6.32 %Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %Reynolds No. 71 782 41 060 26 188*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 74: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:33 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-CanteenTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 25Minimum Flow 0.911   Nm3/hCalibrated Flow 91.114   Nm3/hMaximum Flow 182.229   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 75: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:33 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-CanteenTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Natural Gas Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 76: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:36 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-SchaffTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 17 210 260 Nm3/hPressure 1.6 bar_gTemperature 30 °CDensity 1.7929 kg/m3Viscosity 0.01146 cPZ-factor 0.9955Sound Velocity 433.5 m/sPressure (min/max) 1.6 1.6 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 50Minimum Flow 4.146   Nm3/hCalibrated Flow 414.571   Nm3/hMaximum Flow 829.142   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* PN 40 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application is Cat. II

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65F 65F50-AE**GP

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 77: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:36 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-SchaffTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 17 210 260 Nm3/hPressure loss 3.11E-3 0.31 0.48 mbarVelocity (meas. tube) 1.067 13.18 16.31 m/sMeasured error Mass*** 3.66 1.5 1.5 %Reynolds No. 8 209 101 399 125 542***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 78: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:36 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-SchaffTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Natural Gas State GasChemical formula NASA-Langley Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Dangerous Fluid (Fluid group 1)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass%2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass%3    Methane (Gas) 91.82   Mole% 85.5   Mass%4    Ethane (Gas) 4.85   Mole% 8.53   Mass%5    Propane (Gas) 0.26   Mole% 0.68   Mass%6    n-Butane (Gas) 0.06   Mole% 0.21   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) -77.57   °CPc (Critical pressure) 46.1041   barRho_c (Critical density) 168.8   kg/m3

Tm (Melting point) n.a.   °CTb (Boiling point) n.a.   °C

Calculated resultsDensity nom. 1.7929   kg/m3Molar mass 17.214   kg/kmolZ-factor nom. 0.9955Viscosity nom. 0.01146   cPSound velocity nom. 433.5   m/sThermal capacity nom. 2.153   kJ/(kg*K)Heat conductivity nom. 0.034   W/(m K)Vapor pressure nom.   bar_a

Pressure nom. 1.6   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 0.77   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 0.7296   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 79: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:36 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-SchaffTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Natural Gas Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65F t-mass 65F t-mass 65FFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 40 DN 50 DN 80Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 40 EN 1092-1B1 / 1.4404/316L

PN 40 EN 1092-1B1 / 1.4404/316L

Minimum Flow 2.528 4.146 9.746 Nm3/hCalibrated Flow 252.843 414.571 974.591 Nm3/hMaximum Flow 505.685 829.142 1 949.18 Nm3/hPressure loss at req. Flow min. 8.96E-3 3.11E-3 5.52E-4 mbarPressure loss at req. Flow nom. 1.02 0.31 0.04 mbarPressure loss at req. Flow max. 1.56 0.48 0.06 mbarVelocity (meas. tube) at req. Flow min. 1.779 1.067 0.432 m/sVelocity (meas. tube) at req. Flow nom. 21.97 13.18 5.338 m/sVelocity (meas. tube) at req. Flow max. 27.21 16.31 6.609 m/sMeas. error Mass at req. Flow min.*** 2.23 3.66 8.6 %Meas. error Mass at req. Flow nom.*** 1.5 1.5 1.5 %Meas. error Mass at req. Flow max.*** 1.7 1.5 1.5 %Reynolds No. 130 941 101 399 64 539*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 80: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:36 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-SchaffTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65FFlow Principle Thermal (t-mass)Meter Size DN 50Minimum Flow 4.146   Nm3/hCalibrated Flow 414.571   Nm3/hMaximum Flow 829.142   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 81: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:36 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : NG-SchaffTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Natural Gas Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 82: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:07 AMApplicator®: 10.16.05 / 133

- 1 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Compressed AirTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Air (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Normal Fluid (Fluid group 2)

Operating Conditionsminimum nominal maximum

Requested Flow 105 2 950 3 100 Nm3/hPressure 6 bar_gTemperature 30 °CDensity 8.0688 kg/m3Viscosity 0.01889 cPZ-factor 0.9988Sound Velocity 348.1 m/sPressure (min/max) 6 6 bar_gTemp. (min/max) 30 30 °C

Flowmeter : t-mass 65IFlow Principle Thermal (t-mass)Meter Size DN 150Minimum Flow 60.706   Nm3/hCalibrated Flow 6 070.551   Nm3/hMaximum Flow 12 141.1   Nm3/hMaterial (sensor) * SS 1.4404 / 316LProcess connection* G 1 A ISO 228 / 1.4404 /316L ThreadPED category ** : Application meets PED (Art.3.3)

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65I 65I-20AB

1 Accessory Mounting boss - DK6MB DK6MB-B

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 83: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:07 AMApplicator®: 10.16.05 / 133

- 2 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Compressed AirTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 105 2 950 3 100 Nm3/hPressure loss 6.13E-5 0.04 0.05 mbarVelocity (meas. tube) 0.237 6.671 7.011 m/sMeasured error Mass*** 8.67 1.5 1.5 %Reynolds No. 16 054 451 054 473 989***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 84: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:07 AMApplicator®: 10.16.05 / 133

- 3 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Compressed AirTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Air (Gas) State GasChemical formula Calculation standard NEL

Fluid descriptionMedium character CleanFluid group (PED) Normal Fluid (Fluid group 2)Fluid stability Stable

Gas mixtureComponent

Fraction

1    Air (Gas) 100   Mole% 100   Mass%2    0   Mole% 0   Mass%3    0   Mole% 0   Mass%4    0   Mole% 0   Mass%5    0   Mole% 0   Mass%6    0   Mole% 0   Mass%7    0   Mole% 0   Mass%8    0   Mole% 0   Mass%

Basic fluid parametersTc (Critical temperature) -140.6   °CPc (Critical pressure) 37.69   barRho_c (Critical density) 324   kg/m3

Tm (Melting point) -209.7   °CTb (Boiling point) -195.8   °C

Calculated resultsDensity nom. 8.0688   kg/m3Molar mass 28.964   kg/kmolZ-factor nom. 0.9988Viscosity nom. 0.01889   cPSound velocity nom. 348.1   m/sThermal capacity nom. 1.015   kJ/(kg*K)Heat conductivity nom. 0.027   W/(m K)Vapor pressure nom. 1 172.5   bar_a

Pressure nom. 6   bar_gTemperature nom. 30   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_aDensity normal 1.2929   kg/m3Temperature 0   °CPressure 1.0132   bar_a

Atmospheric pressure 1.0132   bar_aDensity standard 1.2254   kg/m3Temperature 59   °FPressure 14.696   psi_a

SARFRAZ
Highlight
Page 85: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:07 AMApplicator®: 10.16.05 / 133

- 4 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Compressed AirTimestamp: --- Review number: ---Sales order number:

Installation sheetFlowmeter / Accessories

  Extended order codeQty Item Description Extended order code

1 Flowmeter t-mass 65I 65I-20AB

1 Accessory Mounting boss - DK6MB DK6MB-B

Installation data :Insertion depth X (scale value) 160.49   mmInsertion tube length 235   mmPipe inner diameter 20°C 158.3   mmDuct Installation HorizontalDuct internal height  Duct internal width  Wall thickness 5   mmC1 = Height process connection 60   mmC2 = Height sensor connection 46   mmC3 = Height ball valve 0   mmC = Total height of connection 106   mmA= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation)B= Wall thicknessC= Height of connection

*The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to applicationdata. Endress + Hauser takes no liability for the suitability of the pipe dimensions.Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 86: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:07 AMApplicator®: 10.16.05 / 133

- 5 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Compressed AirTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Air (Gas) Ref. Temperature 0 °CState Gas Ref. Pressure 1.013 bar_aCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Normal Fluid (Fluid group 2)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter t-mass 65I t-mass 65I t-mass 65IFlow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)Meter Size DN 100 DN 150 DN 200Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316LMinimum Flow 26.353 60.706 105.919 Nm3/hCalibrated Flow 2 635.329 6 070.551 10 591.911 Nm3/hMaximum Flow 5 270.66 12 141.1 21 183.8 Nm3/hPressure loss at req. Flow min. 4.05E-4 6.13E-5 1.58E-5 mbarPressure loss at req. Flow nom. 0.32 0.04 0.01 mbarPressure loss at req. Flow max. 0.36 0.05 0.01 mbarVelocity (meas. tube) at req. Flow min. 0.547 0.237 0.136 m/sVelocity (meas. tube) at req. Flow nom. 15.37 6.671 3.824 m/sVelocity (meas. tube) at req. Flow max. 16.15 7.011 4.018 m/sMeas. error Mass at req. Flow min.*** 3.76 8.67 n.a. %Meas. error Mass at req. Flow nom.*** 2.34 1.5 1.5 %Meas. error Mass at req. Flow max.*** 2.73 1.5 1.5 %Reynolds No. 684 582 451 054 341 473*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 87: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:07 AMApplicator®: 10.16.05 / 133

- 6 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Compressed AirTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : t-mass 65IFlow Principle Thermal (t-mass)Meter Size DN 150Minimum Flow 60.706   Nm3/hCalibrated Flow 6 070.551   Nm3/hMaximum Flow 12 141.1   Nm3/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 88: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:07 AMApplicator®: 10.16.05 / 133

- 7 / 7 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Compressed AirTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Air (Gas) Abrasivity Not abrasiveState GasCharacter Clean Flow Principle Thermal (t-mass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum30°C nominal : 30°C maximum : 30°C(M) CF3M - A 351 A A A(P) EPDM A A A(M) Alloy C22/2.4602 A A A(P) Kalrez A A A(P) PEEK A A A(P) PVDF A A A(M) Stainless steel 316L/316/1.4404 A A A(P) Viton A A A*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 89: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:52 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Boiler SteamTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Steam, saturatedState Steam SaturatedCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Normal Fluid (Fluid group 2)

Operating Conditionsminimum nominal maximum

Requested Flow 320 4 450 4 600 kg/hPressure 6 bar_gTemperature 165 °CDensity 3.6727 kg/m3Viscosity 0.01451 cPSound Velocity 497.5 m/sPressure (min/max) 6 6 bar_gTemp. (min/max) 165 165 °C

Flowmeter : Prowirl F 200Flow Principle Vortex (Prowirl)Meter Size DN 100Minimum Flow 305.902   kg/hMaximum Flow 11 724.9   kg/hMaterial (sensor) * SS 1.4408 / CF3MProcess connection* PN 16 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application is Cat. I

  Extended order codeQty Item Description Extended order code

1 Flowmeter Prowirl F 200 7F2B1H-*******D1S*+PF

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 90: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:52 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Boiler SteamTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 320 4 450 4 600 kg/hPressure loss 0.48 94.2 100.66 mbarVelocity (meas. tube) 3.275 45.54 47.08 m/sMeasured error Vol.*** 1 1 1 %Measured error Mass*** 1.7 1.7 1.7 %Reynolds No. 80 411 1 118 213 1 155 906***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 91: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:52 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Boiler SteamTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Steam, saturated State Steam Saturated    Calculation standard IAPWS

Fluid descriptionMedium character CleanFluid group (PED) Normal Fluid (Fluid group 2)Fluid stability StableTc (Critical temperature) 401.1   °CPc (Critical pressure) 22.9   bar

Tm (Melting point) 0.04   °CTb (Boiling point) 100   °CKappa 1.29

Calculated resultsDensity nom. 3.6727   kg/m3Viscosity nom. 0.01451   cPSound velocity nom. 497.5   m/sVapor pressure nom. 7.0132   bar_a

Pressure nom. 6   bar_gTemperature nom. 165   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a

SARFRAZ
Highlight
Page 92: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:52 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Boiler SteamTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Steam, saturatedState Steam SaturatedCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Normal Fluid (Fluid group 2)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter Prowirl F 200 Prowirl F 200 Prowirl F 200Flow Principle Vortex (Prowirl) Vortex (Prowirl) Vortex (Prowirl)Meter Size DN 80 DN 100 DN 150Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 16 EN 1092-1B1 / 1.4404/316L

PN 16 EN 1092-1B1 / 1.4404/316L

Minimum Flow 176.593 305.902 695.869 kg/hMaximum Flow 6 768.61 11 724.9 26 671.8 kg/hPressure loss at req. Flow min. 0.9 0.48 0.09 mbarPressure loss at req. Flow nom. 175.22 94.2 18.75 mbarPressure loss at req. Flow max. 187.23 100.66 20.04 mbarVelocity (meas. tube) at req. Flow min. 5.673 3.275 1.44 m/sVelocity (meas. tube) at req. Flow nom. 78.89 45.54 20.02 m/sVelocity (meas. tube) at req. Flow max. 81.55 47.08 20.7 m/sMeas. error Vol. at req. Flow min.*** 1 1 n.a. %Meas. error Vol. at req. Flow nom.*** 2 1 1 %Meas. error Vol. at req. Flow max.*** 2 1 1 %Meas. error Mass at req. Flow min.*** 1.7 1.7 n.a. %Meas. error Mass at req. Flow nom.*** n.a. 1.7 1.7 %Meas. error Mass at req. Flow max.*** n.a. 1.7 1.7 %Reynolds No. 1 471 733 1 118 213 741 399*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 93: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:52 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Boiler SteamTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : Prowirl F 200Flow Principle Vortex (Prowirl)Meter Size DN 100Minimum Flow 305.902   kg/hMaximum Flow 11 724.9   kg/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 94: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 09:52 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Boiler SteamTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Steam, saturated Abrasivity Not abrasiveState Steam SaturatedCharacter Clean Flow Principle Vortex (Prowirl)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum165°C nominal : 165°C maximum : 165°C(M) CF3M - A 351 A A A(M) Graphite A A A(P) Gylon B B B(M) Alloy C22/2.4602 A A A(M) Alloy C22/2.4602/CX2MW A A A(P) Kalrez A A A(M) Stainless steel 316L/1.4435 A A A(M) Stainless steel 316L/316/1.4404 A A A(M) Stainless steel 316Ti/1.4571 A A A(P) Viton NR NR NR*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 95: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:27 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Chiller SteamTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Steam, saturatedState Steam SaturatedCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Normal Fluid (Fluid group 2)

Operating Conditionsminimum nominal maximum

Requested Flow 50 1 020 1 100 kg/hPressure 6 bar_gTemperature 165 °CDensity 3.6727 kg/m3Viscosity 0.01451 cPSound Velocity 497.5 m/sPressure (min/max) 6 6 bar_gTemp. (min/max) 165 165 °C

Flowmeter : Prowirl F 200Flow Principle Vortex (Prowirl)Meter Size DN 40Minimum Flow 47.194   kg/hMaximum Flow 1 130.56   kg/hMaterial (sensor) * SS 1.4408 / CF3MProcess connection* PN 40 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application is Cat. I

  Extended order codeQty Item Description Extended order code

1 Flowmeter Prowirl F 200 7F2B40-*******D2S*+PF

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 96: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:27 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Chiller SteamTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 50 1 020 1 100 kg/hPressure loss 0.57 239.55 278.6 mbarVelocity (meas. tube) 3.317 67.67 72.97 m/sMeasured error Vol.*** 1 1 1 %Measured error Mass*** 1.7 1.7 1.7 %Reynolds No. 31 988 652 547 703 727***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 97: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:27 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Chiller SteamTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Steam, saturated State Steam Saturated    Calculation standard IAPWS

Fluid descriptionMedium character CleanFluid group (PED) Normal Fluid (Fluid group 2)Fluid stability StableTc (Critical temperature) 401.1   °CPc (Critical pressure) 22.9   bar

Tm (Melting point) 0.04   °CTb (Boiling point) 100   °CKappa 1.29

Calculated resultsDensity nom. 3.6727   kg/m3Viscosity nom. 0.01451   cPSound velocity nom. 497.5   m/sVapor pressure nom. 7.0132   bar_a

Pressure nom. 6   bar_gTemperature nom. 165   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a

SARFRAZ
Highlight
Page 98: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:27 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Chiller SteamTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Steam, saturatedState Steam SaturatedCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Normal Fluid (Fluid group 2)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter Prowirl F 200 Prowirl F 200 Prowirl F 200Flow Principle Vortex (Prowirl) Vortex (Prowirl) Vortex (Prowirl)Meter Size DN 25 DN 40 DN 50Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 40 EN 1092-1B1 / 1.4404/316L

PN 40 EN 1092-1B1 / 1.4404/316L

Minimum Flow 19.198 47.194 78.699 kg/hMaximum Flow 459.893 1 130.56 3 016.44 kg/hPressure loss at req. Flow min. 3.05 0.57 0.21 mbarPressure loss at req. Flow nom. 1 271.82 239.55 87.49 mbarPressure loss at req. Flow max. 1 479.14 278.6 101.76 mbarVelocity (meas. tube) at req. Flow min. 8.154 3.317 1.989 m/sVelocity (meas. tube) at req. Flow nom. 166.3 67.67 40.58 m/sVelocity (meas. tube) at req. Flow max. 179.4 72.97 43.76 m/sMeas. error Vol. at req. Flow min.*** 1 1 n.a. %Meas. error Vol. at req. Flow nom.*** n.a. 1 1 %Meas. error Vol. at req. Flow max.*** n.a. 1 1 %Meas. error Mass at req. Flow min.*** 1.7 1.7 n.a. %Meas. error Mass at req. Flow nom.*** n.a. 1.7 1.7 %Meas. error Mass at req. Flow max.*** n.a. 1.7 1.7 %Reynolds No. 1 023 129 652 547 505 326*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 99: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:27 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Chiller SteamTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : Prowirl F 200Flow Principle Vortex (Prowirl)Meter Size DN 40Minimum Flow 47.194   kg/hMaximum Flow 1 130.56   kg/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.Attention for Flow! Device is used in non-ideal application conditions.

SARFRAZ
Highlight
Page 100: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:27 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Chiller SteamTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Steam, saturated Abrasivity Not abrasiveState Steam SaturatedCharacter Clean Flow Principle Vortex (Prowirl)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum165°C nominal : 165°C maximum : 165°C(M) CF3M - A 351 A A A(M) Graphite A A A(P) Gylon B B B(M) Alloy C22/2.4602 A A A(M) Alloy C22/2.4602/CX2MW A A A(P) Kalrez A A A(M) Stainless steel 316L/1.4435 A A A(M) Stainless steel 316L/316/1.4404 A A A(M) Stainless steel 316Ti/1.4571 A A A(P) Viton NR NR NR*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 101: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:35 AMApplicator®: 10.16.05 / 133

- 1 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Diesel LineTimestamp: --- Review number: ---Sales order number:

Sizing SheetGeneral ParametersFluid Fuel Oil (light)State LiquidCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Operating Conditionsminimum nominal maximum

Requested Flow 5 1 750 2 000 kg/hPressure 1.6 bar_gTemperature 45 °CDensity 841.94 kg/m3Viscosity 5.99295 cPSound Velocity 1 250 m/sPressure (min/max) 1.6 1.6 bar_gTemp. (min/max) 45 45 °CVapor Pressure 1.4811E-11 1.4811E-11 1.4811E-11 bar_a

Flowmeter : Promass E 200Flow Principle Coriolis (Promass)Meter Size DN 25Minimum Flow 0   kg/hMaximum Flow 18 000   kg/hMaterial (sensor) * SS 1.4539/904L, ext.temp.Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L FlangePED category ** : Application meets PED (Art.3.3)

  Extended order codeQty Item Description Extended order code

1 Flowmeter Promass E 200 8E2B25-******AD2S

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissiblepressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

SARFRAZ
Highlight
Page 102: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:35 AMApplicator®: 10.16.05 / 133

- 2 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Diesel LineTimestamp: --- Review number: ---Sales order number:

Sizing SheetSizing and Calculated Results

minimum nominal maximumRequested Flow 5 1 750 2 000 kg/hPressure loss 0.03 69.86 87.57 mbarVelocity (meas. tube) 0.007 2.553 2.917 m/sMeasured error Vol.*** n.a. 0.25 0.25 %Measured error Mass*** n.a. 0.25 0.25 %Reynolds No. 12 4 303 4 918***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 103: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:35 AMApplicator®: 10.16.05 / 133

- 3 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Diesel LineTimestamp: --- Review number: ---Sales order number:

Fluid properties sheetFluidFluid name Fuel Oil (light) State LiquidChemical formula Calculation standard Supporting Points

Fluid descriptionSolid content 0   %Medium character CleanAbrasivity Not abrasiveConductivity Not conductiveFluid group (PED) Dangerous Fluid (Fluid group 1)

Basic fluid parametersTc (Critical temperature) 374.1   °CPc (Critical pressure) 221.2   barHeating value 11.833   kWh/Nm3

Tm (Melting point) -20.16   °CTb (Boiling point) 249.8   °C

Temperature / ViscosityTemperature   Viscosity  1    15 °C 13.7 cP2    50 °C 5.3 cP

Temperature / DensityTemperature   Density  1    15 °C 860 kg/m32    50 °C 839 kg/m3

Temperature / Heat capacityTemperature   Thermal capacity  1    10 °C 0 kJ/(kg*K)2    100 °C 0 kJ/(kg*K)

 

Calculated resultsDensity nom. 841.94   kg/m3Viscosity nom. 5.99295   cPSound velocity nom. 1 250   m/sVapor pressure nom. 1.4811E-11   bar_a

Pressure nom. 1.6   bar_gTemperature nom. 45   °C

 Reference values:   Normal conditions (SI): Standard conditions (US):Atmospheric pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a

SARFRAZ
Highlight
Page 104: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:35 AMApplicator®: 10.16.05 / 133

- 4 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Diesel LineTimestamp: --- Review number: ---Sales order number:

Tri-Size SheetGeneral ParametersFluid Fuel Oil (light)State LiquidCharacter Clean Atmospheric Pressure 1.0132 bar_aAbrasivity Not abrasive Standard EN/DIN/ISOFluid Group (PED) Dangerous Fluid (Fluid group 1)

Sizing and Calculated ResultsNext Smaller Size Current Size Next Bigger Size

Flow meter Promass E 200 Promass E 200 Promass E 200Flow Principle Coriolis (Promass) Coriolis (Promass) Coriolis (Promass)Meter Size DN 15 DN 25 DN 40Process connection* PN 40 EN 1092-1

B1 / 1.4404/316LPN 40 EN 1092-1B1 / 1.4404/316L

PN 40 EN 1092-1B1 / 1.4404/316L

Minimum Flow 0 0 0 kg/hMaximum Flow 6 500 18 000 45 000 kg/hPressure loss at req. Flow min. 0.11 0.03 9.03E-3 mbarPressure loss at req. Flow nom. 290.08 69.86 15.79 mbarPressure loss at req. Flow max. 364.36 87.57 19.7 mbarVelocity (meas. tube) at req. Flow min. 0.015 0.007 0.003 m/sVelocity (meas. tube) at req. Flow nom. 5.336 2.553 1.187 m/sVelocity (meas. tube) at req. Flow max. 6.098 2.917 1.356 m/sMeas. error Vol. at req. Flow min.*** n.a. n.a. n.a. %Meas. error Vol. at req. Flow nom.*** 0.25 0.25 0.31 %Meas. error Vol. at req. Flow max.*** 0.25 0.25 0.27 %Meas. error Mass at req. Flow min.*** n.a. n.a. n.a. %Meas. error Mass at req. Flow nom.*** 0.25 0.25 0.31 %Meas. error Mass at req. Flow max.*** 0.25 0.25 0.27 %Reynolds No. 6 222 4 303 2 934*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 105: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:35 AMApplicator®: 10.16.05 / 133

- 5 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Diesel LineTimestamp: --- Review number: ---Sales order number:

Chart SheetFlowmeter : Promass E 200Flow Principle Coriolis (Promass)Meter Size DN 25Minimum Flow 0   kg/hMaximum Flow 18 000   kg/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information intechnical documentation.

SARFRAZ
Highlight
Page 106: Application Flow Sizing and Order Code Configuration

Print date: 29.04.2014 10:35 AMApplicator®: 10.16.05 / 133

- 6 / 6 -

 

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errorsand consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. Achange in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - FlowProject : Instruments Add on BMSCustomer: Pepsico C.Project No.: WNV_00234Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830

eMail: [email protected]

TAG : Diesel LineTimestamp: --- Review number: ---Sales order number:

Corrosion InformationGeneral ParametersFluid Fuel Oil (light) Abrasivity Not abrasiveState LiquidCharacter Clean Flow Principle Coriolis (Promass)

Interpretation of Data, (M) Material:A: resistant, 0.05 mm/y (0.002 inches/y)B: insufficient resistant, 0.5 mm/y (0.02 inches/y)C: not resistant, 1.3 mm/y (0.05 inches/y)NR: not recommendedU: unknown

Interpretation of Data, (P) Plastics:A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/yB: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/yC: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/yNR: not recommendedU: unknown

TemperatureMaterial (Sensor) * minimum45°C nominal : 45°C maximum : 45°C*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees andassumes no liability for the corrosion resistance of the materials selected here for the application described above.

SARFRAZ
Highlight
Page 107: Application Flow Sizing and Order Code Configuration

Endress+Hauser Consult AGKägenstrasse 2CH - 4153 Reinach BL 1

WATT N VOLT18km.Ferozpur Road Lahore, Pakistan

Tell # +92 42 35401829Fax # +92 42 35820830

[email protected]+92 332 8449027

28.04.2014Project name: BMS Add-onProject no.: WNV_00234Cart: Instruments for Pepsico

Pos. Qty. Ordercode

Product

SPKMatNo.

1 1 7F2B1H-B2GCJA3D1SK+AAPFPHZ1 DBI71197720

Prowirl F 200, 7F2B1H, DN100 4"

SPK: DBI[B2] Approval: ATEX II 1/2G Ex ia, II2D Ex tb IIIC[G] Output; Input: PROFIBUS PA, pulse/freq./switch output[C] Display; Operation: SD02 4-line; push buttons +data backup function[J] Housing: GT20 dual compartment, remote,alu coated[A] Electrical connection: Gland M20[3] Sensor Version: Mass flow (integrated temperaturemeasurement)[D1S] Process Connection: PN16, flange EN1092-1-B1 (DIN2501)[K] Calibration Flow: 0.75% volume 3-point[AA] >Operation Language Display: English[PF] >>Accessory Enclosed: Flow conditioner[PH] >>Accessory Enclosed: Cable, remote, 20m[Z1] >>Marking: (50105107)Boiler Steam Tagging (TAG), see additional spec.

Boiler Steam

2 1 7F2B40-B2GCJA3D2SK+AAPFPHZ1 DBI71197717

Prowirl F 200, 7F2B40, DN40 1 1/2"

SPK: DBI[B2] Approval: ATEX II 1/2G Ex ia, II2D Ex tb IIIC[G] Output; Input: PROFIBUS PA, pulse/freq./switch output[C] Display; Operation: SD02 4-line; push buttons +data backup function[J] Housing: GT20 dual compartment, remote,alu coated[A] Electrical connection: Gland M20[3] Sensor Version: Mass flow (integrated temperaturemeasurement)[D2S] Process Connection: PN40, flange EN1092-1-B1 (DIN2501)[K] Calibration Flow: 0.75% volume 3-point[AA] >Operation Language Display: English[PF] >>Accessory Enclosed: Flow conditioner[PH] >>Accessory Enclosed: Cable, remote, 20m[Z1] >>Marking: (50105107)Chiller Steam Tagging (TAG), see additional spec.

Chiller Steam

3 1 65F40-AE2AG1HCABBH1 DHA50109563

t-mass 65F40, DN40 1 1/2"

SPK: DHA[A] Material Measuring Tube; Sensor: Stainl. steel; Stainl. steel[E] Process Connection: PN40, flange EN1092-1-B1 (DIN2501)[2] Seal: PEEK, Viton, -20...+100oC/-4...+212oF[A] Surface cleaning: Basic version[G] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC

Page 1 / 6

SARFRAZ
Highlight
SARFRAZ
Highlight
SARFRAZ
Highlight
Page 108: Application Flow Sizing and Order Code Configuration

[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)LPG-KK Tagging (TAG), see additional spec.

LPG-KK

4 1 65F80-AE2AG1HCABBH1 DHA50109565

t-mass 65F80, DN80 3"

SPK: DHA[A] Material Measuring Tube; Sensor: Stainl. steel; Stainl. steel[E] Process Connection: PN40, flange EN1092-1-B1 (DIN2501)[2] Seal: PEEK, Viton, -20...+100oC/-4...+212oF[A] Surface cleaning: Basic version[G] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)LPG-Boiler Tagging (TAG), see additional spec.

LPG-Boiler

5 1 65F40-AE2AG1HCABBH1 DHA50109563

t-mass 65F40, DN40 1 1/2"

SPK: DHA[A] Material Measuring Tube; Sensor: Stainl. steel; Stainl. steel[E] Process Connection: PN40, flange EN1092-1-B1 (DIN2501)[2] Seal: PEEK, Viton, -20...+100oC/-4...+212oF[A] Surface cleaning: Basic version[G] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)LPG-Canteen Tagging (TAG), see additional spec.

LPG-Canteen

6 1 65F40-AE2AG1HCABBH1 DHA50109563

t-mass 65F40, DN40 1 1/2"

SPK: DHA[A] Material Measuring Tube; Sensor: Stainl. steel; Stainl. steel[E] Process Connection: PN40, flange EN1092-1-B1 (DIN2501)[2] Seal: PEEK, Viton, -20...+100oC/-4...+212oF[A] Surface cleaning: Basic version[G] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)LPG-Schaff Tagging (TAG), see additional spec.

LPG-Schaff

Page 2 / 6

SARFRAZ
Highlight
SARFRAZ
Highlight
SARFRAZ
Highlight
Page 109: Application Flow Sizing and Order Code Configuration

7 1 65I-20AB1AD1HCABBH1 DHC50109555

t-mass 65I

SPK: DHC[20] Insertion Tube Length: 235 mm 9"[A] Material Insertion Tube; Sensor: Stainl. steel; Stainl. steel[B] Process Connection: G 1 A, thread ISO 228, compressionfitting, Stainl. steel[1] Seal: PEEK, Nitrile, -35...+130oC/-31...+266oF[A] Surface cleaning: Basic version[D] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)NG-Main Tagging (TAG), see additional spec.

NG-Main

8 1 65F1H-AB2AG1HCABBH1 DHA50109566

t-mass 65F1H, DN100 4"

SPK: DHA[A] Material Measuring Tube; Sensor: Stainl. steel; Stainl. steel[B] Process Connection: PN16, flange EN1092-1-B1 (DIN2501)[2] Seal: PEEK, Viton, -20...+100oC/-4...+212oF[A] Surface cleaning: Basic version[G] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)NG-KHX Tagging (TAG), see additional spec.

NG-KHX

9 1 65F80-AE2AG1HCABBH1 DHA50109565

t-mass 65F80, DN80 3"

SPK: DHA[A] Material Measuring Tube; Sensor: Stainl. steel; Stainl. steel[E] Process Connection: PN40, flange EN1092-1-B1 (DIN2501)[2] Seal: PEEK, Viton, -20...+100oC/-4...+212oF[A] Surface cleaning: Basic version[G] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)NG-Gas_Genset Tagging (TAG), see additional spec.

NG-Gas_Genset

10 1 65F50-AE2AG1HCABBH1 DHA50109564

t-mass 65F50, DN50 2"

SPK: DHA[A] Material Measuring Tube; Sensor: Stainl. steel; Stainl. steel[E] Process Connection: PN40, flange EN1092-1-B1 (DIN2501)[2] Seal: PEEK, Viton, -20...+100oC/-4...+212oF[A] Surface cleaning: Basic version[G] Calibration: Factory calibration

Page 3 / 6

SARFRAZ
Highlight
SARFRAZ
Highlight
SARFRAZ
Highlight
SARFRAZ
Highlight
Page 110: Application Flow Sizing and Order Code Configuration

[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)NG-KK Tagging (TAG), see additional spec.

NG-KK

11 1 65F80-AE2AG1HCABBH1 DHA50109565

t-mass 65F80, DN80 3"

SPK: DHA[A] Material Measuring Tube; Sensor: Stainl. steel; Stainl. steel[E] Process Connection: PN40, flange EN1092-1-B1 (DIN2501)[2] Seal: PEEK, Viton, -20...+100oC/-4...+212oF[A] Surface cleaning: Basic version[G] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)NG-Boiler Tagging (TAG), see additional spec.

NG-Boiler

12 1 65F25-AE2AG1HCABBH1 DHA50109562

t-mass 65F25, DN25 1"

SPK: DHA[A] Material Measuring Tube; Sensor: Stainl. steel; Stainl. steel[E] Process Connection: PN40, flange EN1092-1-B1 (DIN2501)[2] Seal: PEEK, Viton, -20...+100oC/-4...+212oF[A] Surface cleaning: Basic version[G] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)NG-Canteen Tagging (TAG), see additional spec.

NG-Canteen

13 1 65F50-AE2AG1HCABBH1 DHA50109564

t-mass 65F50, DN50 2"

SPK: DHA[A] Material Measuring Tube; Sensor: Stainl. steel; Stainl. steel[E] Process Connection: PN40, flange EN1092-1-B1 (DIN2501)[2] Seal: PEEK, Viton, -20...+100oC/-4...+212oF[A] Surface cleaning: Basic version[G] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)NG-Schaff

Page 4 / 6

SARFRAZ
Highlight
SARFRAZ
Highlight
SARFRAZ
Highlight
Page 111: Application Flow Sizing and Order Code Configuration

Tagging (TAG), see additional spec.

NG-Schaff

14 1 65I-20AB1AD1HCABBH1 DHC50109555

t-mass 65I

SPK: DHC[20] Insertion Tube Length: 235 mm 9"[A] Material Insertion Tube; Sensor: Stainl. steel; Stainl. steel[B] Process Connection: G 1 A, thread ISO 228, compressionfitting, Stainl. steel[1] Seal: PEEK, Nitrile, -35...+130oC/-31...+266oF[A] Surface cleaning: Basic version[D] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)Compressed Air Tagging (TAG), see additional spec.

Compressed Air

15 4 DK6MB-B1A DHS50109557

t-mass, mounting boss

SPK: DHS[B] Process Connection: Welding conn., G 1 A female threadISO 228, stainl. steel[1] Additional Test, certificate: Basic version[A] Additional Option: Basic version

65I-Mounting

16 14 DK6CA-4B DHR50109554

t-mass 65, Cable remote version

SPK: DHR[4] Cable, Remote Version: 20 m[B] Approval: ATEX II 1/2GD, ATEX II2GD, TIIS Zone 1

17 1 8E2B25-BGGCCAAD2S1+AAZ1 DDB71108512

Promass E 200, 8E2B25, DN25 1"

SPK: DDB[BG] Approval: ATEX II3G Ex nA[G] Output: PROFIBUS PA, pulse/freq./switch output[C] Display; Operation: SD02 4-line; push buttons +data backup function[C] Housing: GT20 dual compartment, Alu coated[A] Electrical Connection: Gland M20[A] Meas. Tube Mat., Wetted Parts Surface: Stainl. steel, not polished[D2S] Process Connection: PN40, 316L/1.4404, EN1092-1-B1(DIN2501) flange[1] Calibration Flow: 0.25% Mass[AA] >Operation Language Display: English[Z1] >>Marking: (50061469)Diesel Line Tagging (TAG), see additional spec.

Diesel Line

18 1 DK6ST-1HB0 DHS71027709

Plate flow conditioner 19 hole

SPK: DHS[1H] Pipe Diameter: DN100 4"[B] Process Connection: PN16, flange EN1092-1-B1 (DIN2501)[0] Material: 316L/1.4404

19 1 65I-20AB1AD1HCABBH1 DHC50109555

t-mass 65I

SPK: DHC[20] Insertion Tube Length: 235 mm 9"[A] Material Insertion Tube; Sensor: Stainl. steel; Stainl. steel[B] Process Connection: G 1 A, thread ISO 228, compressionfitting, Stainl. steel[1] Seal: PEEK, Nitrile, -35...+130oC/-31...+266oF[A] Surface cleaning: Basic version[D] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC

Page 5 / 6

SARFRAZ
Highlight
SARFRAZ
Highlight
SARFRAZ
Highlight
SARFRAZ
Highlight
SARFRAZ
Highlight
Page 112: Application Flow Sizing and Order Code Configuration

[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)LPG-Main Tagging (TAG), see additional spec.

LPG-Main

20 1 65I-20AB1AD1HCABBH1 DHC50109555

t-mass 65I

SPK: DHC[20] Insertion Tube Length: 235 mm 9"[A] Material Insertion Tube; Sensor: Stainl. steel; Stainl. steel[B] Process Connection: G 1 A, thread ISO 228, compressionfitting, Stainl. steel[1] Seal: PEEK, Nitrile, -35...+130oC/-31...+266oF[A] Surface cleaning: Basic version[D] Calibration: Factory calibration[1] Additional Test, certificate: Basic version[H] Approval: ATEX II 3G EEx nAC(L) IIC[C] Housing: Wall Alu, IP67 NEMA4X[A] Cable Entry: Gland M20 (EEx d > thread M20)[B] Display; Operation: 20-55VAC / 16-62VDC, 2-line +push buttons[B] Adjustment; Software Feature: Default gas; 1x group.> Additional text: [H] Output, Input: PROFIBUS PA.> Additional text: [1] >>>Marking: (optional): (50061469)LPG-KHX Tagging (TAG), see additional spec.

LPG-KHX

Page 6 / 6