applied satellite engineering€¦ · the harland citadel2 ups was designed for applied satallite...

4
The following resource is brought to you by ASE. Contact information. Contact us at anytime to discuss your particular application and needs. Email: [email protected] Phone +1.480.443.1424 (Americas) Phone +353 85 7615506 (EMEA) www.ase-corp.com APPLIED SATELLITE ENGINEERING

Upload: others

Post on 08-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: APPLIED SATELLITE ENGINEERING€¦ · The Harland Citadel2 UPS was designed for Applied Satallite Engineering (ASE) to support their Citadel Safe-Room Iridium/UPS Communications system

The following resource is brought to you by ASE.

Contact information.

Contact us at anytime to discuss your particular application and needs.

• Email: [email protected]

• Phone +1.480.443.1424 (Americas)

• Phone +353 85 7615506 (EMEA)

• www.ase-corp.com

APPLIED SATELLITE ENGINEERING

Page 2: APPLIED SATELLITE ENGINEERING€¦ · The Harland Citadel2 UPS was designed for Applied Satallite Engineering (ASE) to support their Citadel Safe-Room Iridium/UPS Communications system

ASE CITADEL2

Secure Power for Citadel24vDC UPS for ASE CitadelSecure Power for Anti-Piracy Emergency Communication

The Harland Citadel2 UPS was designed for Applied Satallite Engineering (ASE) to support their Citadel Safe-Room Iridium/UPS Communications system to protect vessels against piracy.

The UPS provides 72 hours of independent battery back-up power to protect the Citadel system and exceeds NATO guidelines.

The Citadel UPS is based on proven high quality longlife and maintenance free components specifically selected to be suitable for marine rugged and harsh environment applications.

• Rugged IP55 enclosure• Exceeds NATO 72 hour requirements• 55 hour talk/100 hour standby• 10 year life high performance Lead Crystal® battery• Easy installations & maintenance• High reliability & maintenance free• Surge protection

ASE Citadel2/June2015

Single replacement of charger/batteries

Rugged charger with input protection

Easy install

Rugged IP55 enclosure

High performance Lead Crystal® batteries

Page 3: APPLIED SATELLITE ENGINEERING€¦ · The Harland Citadel2 UPS was designed for Applied Satallite Engineering (ASE) to support their Citadel Safe-Room Iridium/UPS Communications system

Applied Satallite Engineering (ASE)Citadel System 100/5524VDC UPS ASE-CIT-UPS-EXT-LCB

ASE CITADEL2

Harland Simon UPS Ltd • Bond Avenue • Bletchley • Milton Keynes • MK1 1TJ T: 01908 56 56 56 • E: [email protected] • W: harlandsimonups.com

Harland Reference Harland ProtectUPS® - P/N: HPU-M-0001ASE Reference P/N: ASE-CIT-UPS-EXT-LCB.AC Supply Universal 90-264VAC 50/60 Hz single phase/IT supply.Input Protection 6A double pole MCB.

Power supply is fitted with varistors with 3kV DC-AC isolation to give lightning/surge protection.Low input earth leakage <3.5mA.

Earthing Internal Earth Point.Output 24vDC Nominal Floating DC Output.Battery Type 10+ years design life Lead Crystal® battery, long life, high

temperature, low gassing, maintenance free. P/N: 003-6-CNFJ-24.

Battery Capacity 24Ah (at the 20 hour discharge rate).Number of Cells 12Charger Type Constant voltage, transistor controlled charger with current

limit.Charger Rating 2.5 AmpsBack-Up Time 100 hours powered standby at 4.8W, 55 hours talk time at

8.4W. Minimum 72 hours continuous open line operation exceeding NATO anti-piracy guidelines while supporting Applied Satallite Engineering Citadel System.

Controls None.Meters None.Indications LED indicator for charger healthy.Alarms None.DC Distribution 2 pole circuit breaker rated at 6 Amps.Enclosure Wall mounting steel box with hinged and lockable front access

door. Protection to IP55 (Lead Crystal® batteries do NOT require any special ventilation). Batteries clamped in position.

Shock/Vibration Compliant with: Vibration=IEC60068-2-6.Shock=IEC60068-2-27.

Paint Finish Painted RAL 7035 light grey.Dimensions W 500mm x H 400mm x D 200mm nominal.Weight 32kg approx.Cable Entry Undrilled top entry gland plate. Wire to terminals.

Page 4: APPLIED SATELLITE ENGINEERING€¦ · The Harland Citadel2 UPS was designed for Applied Satallite Engineering (ASE) to support their Citadel Safe-Room Iridium/UPS Communications system

Technical Specification for Harland ProtectUPS UPS for ASE Citadel2 Harland Simon Part Number: HPU-M-0001

Applied Satellite Engineering (ASE) Citadel System 100/55, Part Number: ASE-CIT-UPS-EXT-LCB

Document: TShpum0001 Rev: 00-260615 Author: AP Page: 1 of 1

Harland Ref: Harland ProtectUPS – P/N: HPU-M-0001 ASE Ref: P/N: ASE-CIT-UPS-EXT-LCB AC Supply: Universal 90-264VAC 50/60Hz single phase / IT supply Input Protection 6A double pole mcb

Power supply is fitted with varistors with 3kV DC-AC isolation to give lightning/surge protection Low input earth leakage <3.5mA

Earthing Internal Earth Point Output 24VDC Nominal Floating DC Output Battery Type: 10+ year design life lead crystal battery, long life, high

temperature, low gassing, maintenance free P/N: 003-6-CNFJ-24

Battery Capacity: 24 Ah (at the 20 hour discharge rate) No. of Cells: 12 Charger Type: Constant voltage, transistor controlled charger with current

limit. Charger Rating: 2.5 Amps Backup time: 100 Hours Powered Standby at 4.8W, 55 Hours Talk time at

8.4W. Minimum 72 hours continuous open line operation exceeding NATO anti-piracy guidelines while supporting Applied Satellite Engineering Citadel system

Controls: None. Meters: None. Indications: LED indicator for Charger Healthy Alarms: None. DC Distribution: 2 Pole circuit Breaker rated at 6 Amps. Enclosure: Wall mounting steel box with hinged and lockable front access

door. Protection to IP55 – Lead Crystal batteries do NOT require any special ventilation. Batteries clamped in position.

Shock/vibration Compliant with: Vibration=IEC60068-2-6 Shock=IEC60068-2-27

Paint Finish: Painted RAL7035 light grey. Dimensions: 500mmW x 400mmH x 200mmD nominal. Weight: 32Kg approx. Cable Entry: Undrilled top entry gland plate. Wire to terminals