ALLIED VISION TECHNOLOGIES 07646 | Stadtroda | Germany www.alliedvisiontec.com Taschenweg 2A - 1 Author: Arlin Kalenchuk Application Note: Birger EF-Mount, Modular Option -09 Introduction This document is a guideline for using the Birger EF-mount with AVT cameras. The Birger EF-mount can be used with any Canon EF, Canon EF-S, Tamron Di, and Tamron Di II lenses. These lenses provide motorized iris and focus control. The Birger EF-mount -09 modular option is presently available on the AVT Prosilica GE, GX, and GT series cameras. Ordering information The Birger EF-mount can be ordered as a -09 modifier when purchasing a new AVT camera. Customers with an AVT F-mount GE camera require: F to EF conversion kit (PN: 02-5026B). Customers with an AVT F-mount GX or GT camera require: F to EF conversion (PN: 02-5031B). Customers with an AVT C/CS-mount GE1050, GE1650, GE1660, GE1900, GE1910, GE2040 require: C to F conversion kit (PN: 02-5027A), plus F to EF kit (PN: 02-5026B). Color cameras add IR cut filter (PN: 44-0001). Customers with an AVT C/CS-mount GX or GT require: C to F conversion kit (PN: 02-5037A), plus F to EF kit (PN: 02-5031B). Color cameras add IR cut filter (PN: 44-0001). For customers with any other C/CS-mount Prosilica series camera, Birger EF conversion is not possible. www See the AVT modular concept document for up-to-date information on avail- able modular offerings: http://www.alliedvisiontec.com/us/support/downloads/product- literature/avt-modular-concept.html

Upload: emi-eguchi

Post on 12-Mar-2016

212 views

Category:

Documents


0 download

DESCRIPTION

http://www.aprolink.jp/doc/dldata/support/AV/GigE_Common/Applnote/English/AppNote_-_Birger_EF_Mount_-09.pdf

TRANSCRIPT

Page 1: AppNote_-_Birger_EF_Mount_-09

ALLIED VISION TECHNOLOGIES 07646 | Stadtroda | Germany

www.alliedvisiontec.com Taschenweg 2A -

1Author: Arlin Kalenchuk

Application Note:Birger EF-Mount, Modular Option -09

IntroductionThis document is a guideline for using the Birger EF-mount with AVT cameras. The Birger EF-mount can be used with any Canon EF, Canon EF-S, Tamron Di, and Tamron Di II lenses. These lenses provide motorized iris and focus control.

The Birger EF-mount -09 modular option is presently available on the AVT Prosilica GE, GX, and GT series cameras.

Ordering information• The Birger EF-mount can be ordered as a -09 modifier when purchasing a new AVT camera. • Customers with an AVT F-mount GE camera require: F to EF conversion kit (PN: 02-5026B).• Customers with an AVT F-mount GX or GT camera require: F to EF conversion (PN: 02-5031B).• Customers with an AVT C/CS-mount GE1050, GE1650, GE1660, GE1900, GE1910, GE2040 require: C to

F conversion kit (PN: 02-5027A), plus F to EF kit (PN: 02-5026B). Color cameras add IR cut filter (PN: 44-0001).

• Customers with an AVT C/CS-mount GX or GT require: C to F conversion kit (PN: 02-5037A), plus F to EF kit (PN: 02-5031B). Color cameras add IR cut filter (PN: 44-0001).

• For customers with any other C/CS-mount Prosilica series camera, Birger EF conversion is not possible.

www

See the AVT modular concept document for up-to-date information on avail-able modular offerings:

http://www.alliedvisiontec.com/us/support/downloads/product-literature/avt-modular-concept.html

Page 2: AppNote_-_Birger_EF_Mount_-09

2

Birger EF-Mount included parts

F-mount to Birger EF-mount conversion kit installationThe following instructions apply only to customers who have an AVT F-mount camera, and purchased the F to Birger EF conversion kit separately.

1. Remove the existing F-mount front end from the camera by loosening the three M3 x 3mm hex set screws on the outside of the F-mount adapter. Slide the mount off the camera front flange.

GE Birger Birger EF-mount GE + Birger power supply GE DB9 to Hirose adapter

GX/GT Birger GT/GX + Birger power supply

Note

GT Power over Ethernet (PoE): The Birger unit must be powered via the GT/GX + Birger power supply. Power cannot be routed out from a camera using PoE to the Birger unit.

GT cameras powered by both PoE and the power supply via the Hirose I/O connector will use the power from the Hirose I/O connector only.

Figure 1: GE4000 with F-mount removed

Page 3: AppNote_-_Birger_EF_Mount_-09

3

2. Attach an EF-mount lens to the Birger EF-mount. Using manual focus mode on the lens, adjust the lens to the infinity setting. Slide the Birger EF-mount onto the camera front flange, and lightly set the three M3 x 3 mm hex set screws such that they are barely in contact with the camera flange.

3. Connect power to the camera and live image an object at a distance of 10 m or more with the camera. Slide the Birger EF-mount away or towards the camera body as needed, until the object is in focus. Tighten the 3 hex set screws to prevent further motion.

Birger EF lens control The Birger EF-mount uses the AVT camera RS232 (serial) port, accessible through the 12 pin Hirose con-nector on the back of the camera. Software control of the Birger mount is available through the AVT GigE SampleViewer or PvAPI SDK.

The following instructions describe Birger control through AVT GigE SampleViewer:

1. For a GX/GT camera, connect the 12 pin Birger connector to the camera. For a GE camera, connect the Birger EF-mount DB9 RS232 connector to the camera Hirose port through the provided Hirose to DB9 adaptor.

2. Connect the Birger power plug to the provided camera power supply. A GX/GT camera is connected to the power supply through a Lemo 2-pin locking power connector. Connect/disconnect by aligning the two red dots on the connector and push/pull on the connector sleeves.

Caution

The hex set screws come deeply inserted into the side of the Birger unit. Use a long enough hex tool to prevent damaging the Birger threaded hole.

Note

If using the PvAPI SDK, see the included “siotest” sample code for configuring RS232 communication programmatically.

http://www.alliedvisiontec.com/fileadmin/content/PDF/Software/Prosilica_software/Prosilica_SDK/Allied_Vision_Technologies_GigE_SDK_Installer.exe

Figure 2: AVT Prosilica GT6600 with Birger connection

Page 4: AppNote_-_Birger_EF_Mount_-09

4

3. Open the GigE SampleViewer. Wait until the camera is listed. This may take a few seconds. Click on the camera serial number.

4. Select the “1101” icon in the Cameras window to launch the SerialIO terminal.

5. Configure the camera serial port and click Connect.

Baud rate ....................... 115200

Parity ............................ None

Character length .............. N/A

Stop bits ........................ 1

www

AVT GigE SampleViewer download:

http://www.alliedvisiontec.com/fileadmin/content/PDF/Software/Prosilica_software/Prosilica_Viewer/Allied_Vision_Technologies_GigE_Viewer_Installer.exe

Figure 4: Location of “1101” icon on the Cameras window

Figure 3: Cameras window

Page 5: AppNote_-_Birger_EF_Mount_-09

5

6. Scroll down on the SerialIO window to reach the command input box at the bottom of the window.

7. Initialize the focus and iris axis by entering the following commands in the SerialIO command input box:

rm1.............. [optional] All characters typed are echoed back

in ................ Initialize the aperture motor

la................. Learn the focus range

At this point, you should hear the lens focus adjusting. If not, be sure your lens is in autofocus (AF) mode – there should be an AF/MF switch on the lens itself.

8. See the Birger EF command quick reference section for a list of Birger commands.

Figure 5: Configuring the camera serial port in SerialIO window

Note

THE SerialIO WINDOW IS NOT RESIZABLE. AVT will resolve this issue in the next official GigE SampleViewer release.

Figure 6: Location of command input box in the SerialIO window

Page 6: AppNote_-_Birger_EF_Mount_-09

6

Birger EF command quick reference

Command Arguments Description

bv Print the bootloader version

da Print aperture information

de Dump EEPROM

ds Print distance stops

dz Print the zoom range

eh pos, checksum Set absolute lens focus position (0…0x3FFF)ex Exit to the bootloader

fa position Move focus to absolute positionfd Print focus distance range

ff position Fast focusfp Print the raw focus positions

gs Echo current device and lens surface

hv Print the hardware version

id Print the basic lens identification (zoom and f-number)

in Initialize the aperture motor. Aperture will fully open

is {0, 1} Turn image stabilization off/onla options Learn the focus rangelc Print the cached lens status

ll Library loaded check

lp Lens presence

ls Query lens for status immediately and print

lv Print library version string

ma stop Move aperture to absolute positionmc Move aperture to the fully stopped down limit

mf Move focus incremental

mi Move focus to infinity

mn num_stop Move aperture incrementalmo Move aperture to completely open

mz Move focus to the zero stop

pa Print the aperture position

pf Print the focus position

pl {0, 1} Lens powerrm verbose[,new] Set response modesse byte, val Temporarily set non-volatile (EEPROM) bytesf count Set the focus countersg port, state Set GPIOsm mode_flags Set special modessn Print the device serial number

Table 1: Birger EF command quick reference

www

For a complete listing of commands, refer to The Birger EF232 manual:

http://www.birger.us/products/lens_controller/manuals/canon_ef232/Canon%20EF-232%20Library%20User%20Manual%201.3.pdf

Page 7: AppNote_-_Birger_EF_Mount_-09

7

For technical support, please contact [email protected].

For comments or suggestions regarding this document, please contact [email protected].

Disclaimer

Due to continual product development, technical specifications may be subject to change without notice. All trade-marks are acknowledged as property of their respective owners. We are convinced that this information is correct. We acknowledge that it may not be comprehensive. Nevertheless, AVT cannot be held responsible for any damage in equipment or subsequent loss of data or whatsoever in consequence of this document.

Copyright © 2013

This document was prepared by the staff of Allied Vision Technologies Canada (“AVT”) and is the property of AVT, which also owns the copyright therein. All rights conferred by the law of copyright and by virtue of international copyright conventions are reserved to AVT. This document must not be copied, or reproduced in any material form, either wholly or in part, and its contents and any method or technique available there from must not be disclosed to any other person whatsoever without the prior written consent of AVT.