apr contact us paul greenough air conditioning product ... · the best choice. by choosing...

32
+44 (0) 1460 53535 [email protected] www.powrmatic.co.uk Vision VertiCool 3.1 Condenser-less Air Conditioning Unit VisionVertiCool User, Installation & Servicing Manual Doc Ref: M602 Issue 1.0 Apr 2018

Upload: others

Post on 09-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

+ 4 4 ( 0 ) 1 4 6 0 5 3 5 3 5i n f o @ p o w r m a t i c . c o . u kw w w . p o w r m a t i c . c o . u k

Powrmatic pursues a policy of continues improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the company to confirm whether any material alterations have been made since publication of this brochure.

LondonTR

PL TQ

EXTA

DT BH

SOSPBA

BS SN

GLNPCF

SA

LDHR

TFSY

LL

WS

WVDY

WR

B CV NN

MKLU SG

CB

CO

IP

NRPELE

DE NG

LN

DN

HU

YOHG

LSWF

SSK

ST

CW

WA

BL

MWNL

CH

PR BB

BDLA

OL HDHX

FY

Contact Us

REPUBLIC OF IRELAND

BT

RG

SMKT

TW

UB

HA

WD

NWW

SW

CRBR

DA

RM

IG

EN

NWC

EC

SE

E

Tony Delaney - Ireland

+(353) 0866 040 [email protected]

Geoff Stevenson - Scotland & North East

07971 079 [email protected]

Alan Yates - North West

07812 095 [email protected]

Dave Greaves - Mid Wales

07766 061 [email protected]

Martin Arden - Midlands

07971 079 [email protected]

Chris Spencer- South East

07525 912 [email protected]

Chris Warry - South West

07971 079 [email protected]

Powrmatic LimitedHort BridgeIlminsterSomersetTA19 9PS

Head Office

#keepingthenationwarm

tel: +44 (0) 1460 53535fax: +44 (0) 1460 52341

e-mail: [email protected]: www.powrmatic.co.uk

PO BN

GU

OX HP

SL

RH

CM

SS

ME

TN

CT

AL

CA

DL TS

DH SR

NEDG

TD

EH

MLKA

G

FKPA

PH

KY

DD

AB

IV

KWHS

IM

Paul GreenoughAIr Conditioning Product Manager

+(353) 0866 040 [email protected]

Darryl RedfearnDedicated AIr Conditioning Sales - Northern Region

07531 342 [email protected]

Vision VertiCool 3.1Condenser-less Air Conditioning Unit

VisionVertiCoolUser, Installation& Servicing Manual

Doc Ref: M602 Issue 1.0 Apr 2018

Page 2: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

Compliance

This unit complies with the following European Directives:

• Low voltage 2014/35/EU

• Electro-magnetic compatibility 2014/30/EU

• Use restrictions of hazardous substances in electricaland electronic equipment 2011/65/EC (RoHS2)

• Waste electrical and electronic equipment 2012/19/EC (WEEE).

• Energy consumption indication on the labels of energy-related products 2010/30/EU

• ErP Directive 2009/125/EC and regulation 2012/20EC

The pictograms in the next chapter provide the necessary information for correct, safe use of the appliance in a rapid,

unmistakable way.

Symbols

U User- Refers to pages containing instructions or information

for the user.

I Installer- Refers to pages containing instructions or information

for the installer.

S Service- Refers to pages containing instructions or information

for the CUSTOMER TECHNICAL ASSISTANCESERVICE.

Editorial pictograms

Safety pictograms

Warning- It indicates actions that require caution and a suitable

preparation.

Prohibition- Refers to prohibited actions.

Dear Customer - thank you for choosing Powrmatic..

We appreciate you buying one of our high quality products and know that you have made the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by manufacturing products that provide clean, comfortable and safe working environments worldwide together with the personal & professional service and back-up you deserve. If you have any questions or concerns regarding this product, please contact our Technical Support Team by calling 01460 53535.

page no. 2 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 3: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

1.1 4

1.2 4

1.3 5

1.4 5

1.5 6

1.6 6

1.7 6

1.8 7

2.1 8

2.2 8

2.3 9

2.4 10

2.5 11

2.6 12

2.7 13

2.8 14

2.9 15

2.10 15

2.11 15

2.12 15

2.13 15

3.1 17

3.2 18

3.3 19

1 GeneralGeneral warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fundamental safety rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Shipping dimensions and weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Supplied components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Unit parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 InstallationInstallation method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Choosing the position of the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Assembling the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Condensation drain preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Assembling air ducts and external shutters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Mounting the appliance on the bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

High/low installation configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Setting cool only or heat only modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Brightness regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Touch-screen display key lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Hotel function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Detecting possible faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3 TroubleshootingPeriodic Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 User manual4.1

4.2

4.3

4.4

4.5

4.6

4.7

4.8

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Management of the appliance with the touch-screen display and remote control. . . . . . . . . . . . . . . .

Description of operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Setting cool only or heat only modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Brightness regulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Touch-screen display key lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Hotel function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Suggestions for power saving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.9 Diagnosis of problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5 INNOVA App operation5.1

5.2

Minimum system requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installing and using the APP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

20

21

24

24

24

24

25

25

26

26

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 3 of 32

Page 4: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

1.1

1.2

General warnings

Fundamental safety rules

After unpacking, check that the contents are intact and that all parts are included. If not, contact the agent who sold the appliance to you.

The appliance must be installed by an authorised company. Once the work is done, it must issue a declaration of conformity to the client in compliance with current regulations and with the indications in the instruction manual supplied y the manufacturer with the appliance.

These appliances have been designed for conditioning and/or heating rooms and they must be destined solely for this purpose, in accordance with their performance characteristics.The manufacturer refuses any contractual or extra-contractual liability for damage caused to people, animals or property resulting from incorrect installation, adjustment, maintenance or improper use.

In the event of water leaks, turn off the main switch and close the water taps.Immediately call the Technical Assistance Service or other qualified personnel and do not intervene personally on the appliance.

A temperature that is too high or too low is harmful to health and is an unnecessary waste of energy.Avoid prolonged direct contact with the air flow.

Do not leave the room closed for long. Periodically open the windows to ensure proper ventilation.

This instruction booklet is an integral part of the appliance and, therefore, it must be kept with care and must ALWAYS accompany the appliance, even when the latter is transferred to another owner or user or transferred to another system. If it gets damaged or lost, please request another copy from the local Technical Assistance Service.

Repairs or maintenance must be performed by the Technical Assistance Service or by qualified personnel in accordance with this manual. Do not modify or tamper with the appliance as this could create dangerous situations and the manufacturer will not be liable for any damage caused.

The appliance is declared to have an IPX0 protection rating, therefore, it cannot be installed outdoors or in laundry rooms.

The use of products that use electricity and water requires the observation of some fundamental safety rules such as:

The unit can be used by children over the age of 8, and by people with reduced physical, sensory or mental capabilities, or with no experience or necessary knowledge, as long as they are monitored or after they have received instructions on the safe use of the unit and have understood the dangers involved.Children must not play with the appliance.The cleaning and maintenance that must be performed by the user should not be carried out by children without supervision.

It is forbidden to modify the safety or adjustment devices without authorisation from and indications of the manufacturer.

It is forbidden to pull, remove or twist the electric cables coming out of the unit, even when disconnected from the mains power supply.

It is forbidden to introduce objects or substances through the aspiration grills and the air outflow.

It is forbidden to open the access doors to the internal parts of the appliance without having turned off the main switch first.

It is forbidden to dispose of, or leave in the reach of children, the packaging materials which could become a source of danger.

It is forbidden to climb onto the appliance and/or to place any type of object on top of it.

GENERAL

page no. 4 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 5: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

1.3

1.4

Description

The air conditioning unit "2.0" is the new solution that represents a significant step towards reducing the aesthetic impact of air conditioners. With a depth of just 16 centimetres, "2.0" is the most compact and least bulky of the category. Its aesthetic impact is therefore minimal, both inside and out.

Optimised CapacitiesThe conditioning capacities of "2.0" have been optimised so as to obtain the right temperature for the best level of comfort and, therefore, less consumption and less noise. Thanks to the careful choice of sound insulation materials, the noise is similar to that of a standard wall split unit and consumption is drastically contained thanks to the new direct current fan.

162 millimetre holesAn important choice not only for the design, but also for a significant installation advantage: easier to find drilling tools, no need for professional drills, even less aesthetic impact.

BLDC inverter technologyWe have perfected the inverter technology to offer the best in terms of acoustic comfort (noise) and performance: reduction of consumptions, maintenance of the best temperature level and humidity level in the room.Thanks to the use of the cutting edge BLDC (brushless direct current) inverter regulation, vibrations have been completely eliminated and acoustic emissions have been lowered to exceptional levels.Both ventilation motors are BLDC to reduce consumption still further and make flow adjustment more precise.The energy consumption is extremely low thanks to absorption values falling below 300 W in the case of partial

load. At the nominal cooling power of 2.35 kW “2.0” has an EER equal to 3.24 (10 HP) and 3.22 (12 HP) which allows an energy efficiency ratio of “A+” to be obtained, this is the cutting edge in the sector of monobloc climate control systems with fixed installation.

Easy to install“2.0" can be installed on any perimeter wall either low or high. Everything needed for installation (template, support bracket, hole pipes and external grids), excluding the drill and drill bit, is included in the box.

Folding external grids"2.0" is equipped with folding grids activated by inlet and outlet air. They open when the unit is working and close when it's turned off. Better indoor comfort, less dust, noise and pollution, less maintenance and even less outdoor visibility.

Remote control and on-board touch-screen displayIn addition to the remote control, the touch-screen display on the unit enables the setting of any function. There's even a "lock" mode to avoid any improper use. With a simple action on the touch screen display, the "heating" function can be deactivated: the appliance will then operate in "cooling" only, without the need for the condensate discharge pipe. The orientation of the air flaps, upwards or downwards, can also be set by simply pressing a key.

The packing is made of suitable material and carried out by expert personnel. All units are checked and tested and are delivered complete and in perfect conditions, however please perform the following instructions to check the quality of shipping services: - upon receipt, check if the box is damaged. If that is

the case, accept the goods with reservations andkeep photographic evidence of any damage found

- unpack and check the contents against the packinglist.

- check that none of the parts have been damagedduring shipment. In case of damage, report it tothe shipping company within 3 days of receipt by

registered letter with return receipt and attaching photographic documentation. A copy should also be sent by fax to the MANUFACTURER. No notice of damage incurred will be accepted after 3 days from delivery.

Keep the packing at least for the duration of the warranty period, in case you need to ship the air-conditioner to the service centre for repair. Dispose of the packing materials in compliance with current regulations on waste disposal.

Storage

Store the box in a closed environment protected from atmospheric agents and isolate it from the floor using planks or pallets.

Do not turn the carton upside down

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 5 of 32

Page 6: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

1.5

1.6

1.7

A

BCDEF

GHI

NO

C

D

A++A

I

F

E

B

O

G

A

H

N

2.0 12 HP

kg 50

W mm 580

H mm 1550

D mm 265

Packaging

Dimensions

Weight

Supplied components

The supply consists of the parts listed in the following table. Before assembly, please check that they are all at hand.

External fixed grid for air inlet and outlet (front view)

Screws and plugs kit (6 pcs)

Bracket for wall mounting

User manual

Remote control

Paper template for holes.

CR2025 3V remote control battery

Wall inlet pipes (2 pcs)

Energy efficiency label

Installation manual

External fixed grid for air inlet and outlet (rear view)

Handling

Shipping dimensions and weight

The unit is packed singularly in a cardboard box. Boxes can either be carried singularly by hand by two operators or loaded on a forklift truck, for a maximum of three units.

Handling must be performed by qualified personnel, with specific tools and with equipment suitable for the weight of the appliance.

The appliance is unbalanced on the right (compressor side)

During transportation, the appliance must be kept in vertical position.

page no. 6 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

H

W

D

Page 7: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

123456

789101112

1.8

2

1

3

11

128

9

106

76

4

5

Unit parts

Air outlet flaps

Touch screen display

Front panel

Outdoor air suction

Outdoor air outlet

Internal air intake grille

Air Filter

Condensation drain pipe

Room air probe

Power supply terminal block

Decorative side panel

Anti-lifting bracket

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 7 of 32

Page 8: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

2.1

2.2

60 mm

120

mm

Before installing the conditioner, it is essential to calculate the summer thermal loads (and winter ones for the models with a heat pump) of the room. The more exact the calculation, the better the product will work. Please refer to current regulations to carry out calculations. For large-scale installations, please call a specialised heat engineer firm. Therefore, try to reduce higher heat loads by following instructions below:

- Cover large windows exposed to sunlight with curtainsor with external maskings (blinds, porches, reflectingfilms, etc.).

- The room must remain closed for as long as possible.- Avoid turning on halogen lamps or other high energy

consumption appliances such as small ovens, steamirons, hot plates etc.).

For the best performance of the appliance and to avoid malfunctions or dangerous situations, the location of the unit must meet the following requisites:- Respect the minimum distances indicated in the

diagram.- The wall on which you intend to anchor the unit must

be robust and able to support its weight.- Leave enough space around the unit to perform

maintenance operations.- Nothing must obstruct the air flow both in the top

suction part (curtains, plants, furniture) and in the loweroutlet part, as it could cause vibrations which mightprevent the appliance from working correctly

The unit can be placed on the ground or suspended.

The appliance is stated as having an IPX0 protection rating, therefore it is not suitable for outdoor installation.

Check that there are no structures or systems (beams, pillars, hydraulic pipes, electrical cables etc.) in the part that must be drilled. Check that nothing is placed in front of the holes thus obstructing the air flow (plants and leaves, panelling, shutters, dense grates or grids, etc.)

The unit should not be installed in a position where the air flow is aimed directly at the people nearby;

Never force the air flap open;

The appliance must not be installed directly above another electrical appliance (TV, radio, fridge, etc.) or above a source of heat.

INSTALLATION

Installation method

Placement of the unit

page no. 8 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 9: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

2.3

ABCDE

For the unit to work, two holes Ø162 must be placed as indicated on the template;

The maximum length of the holes is 1 m and there must be no bends. Use the supplied grids or grids with the same characteristics.

The holes on the wall must be drilled using suitable equipment that facilitates your work and that does not cause damage or excessive inconvenience to your customer. The best tools to make big holes on walls are special drills (called "core drills") with a high torque and whose rotation speed can be adjusted according to the diameter of the hole to make and to the material. To avoid excessive dust and debris in the room, "core drills" can be combined with suction systems consisting of a vacuum connected to a suction cup placed next to the perforation tip, for example.To make the holes, proceed as follows:- Place the drilling template provided against the wall

respecting the minimum distances: from the ceiling,from the floor and from the side walls, indicated onthe template itself, which can be held in the correctposition by using some tape.

- Carefully mark the centre of each hole with a small drillor a punch before actual drilling.

- Using the core drill, make two holes for inlet and outletair.

The holes must be drilled slightly downwards to prevent water from entering.

The majority of the removed material is expelled outwards, so please be careful that it doesn't hit people or objects. In order to avoid breaking the outer plaster, be careful while drilling the final part of the hole and ease the pressure on the core drill. Drill the 6 holes for the bracket as indicated on the template. The appliance weighs more on the right, so make sure to secure it properly on this side. The holes must have an 8 mm diameter to accommodate the 6 supplied plugs. A thorough examination of the characteristics and consistency of the wall must always be carried out to determine the number of fixing points to be made and to choose specific plugs in particular conditions. In the case of installation on a plasterboard or on walls with low density, place a bracket, if necessary on the outside, that can support the appliance safely.

The manufacturer cannot be held responsible for any underestimation of the structural consistency of the anchoring carried out by the installer. We, therefore, encourage you to pay the utmost attention to this operation as, if performed badly, it could cause serious damage to people and objects.

Drill a hole in the position indicated on the template for those heat-pump appliances without a condensation drain built in the wall to allow for draining of condensation.

A hole is also indicated on the template to secure the appliance on the wall with an anti-lifting bracket, which is already on the appliance.

Assembling the unit

Holes for M8 plugs

Electrical connection area

Ø162 mm holes for air channelling

Ø16 mm condensation drain

Anti-lifting bracket hole

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 9 of 32

Page 10: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

1 2

2.4

2

1

For heat pump appliances, a condensation drain pipe (internal Ø16 mm, not supplied) must connect the unit to the pipe on the rear of the appliance.A solenoid valve will start the flow of the condensation from the internal collection tray when the maximum level has been reached. For cooling only appliances, this pipe must be connected if the appliance is intended for use with low external temperatures (below 23°C). Drainage occurs by gravity. For this reason, it is essential for the discharge pipe to have at least a 3% minimum slope in every point. The pipe to be used can be rigid or flexible with a minimum inner diameter of 16 mm. If the line flows into a sewer system, it is necessary to add a siphon before placing the pipe into the main drain. This siphon must be placed at least 300 mm under the mouth of the appliance.

If the line flows into a container (e.g. a tank), do not close the container hermetically and avoid immersing the draining pipe into the water.

The hole for the condensation pipe must always slope towards the outside.

The exact position in which to place the pipe mouth is indicated on the template.

Check that the expelled water does not cause any damage or problems to people or objects. During winter, this water may create sheets of ice outside.

When connecting the condensation drain, be careful not to squeeze the rubber duct.

It is possible to empty the collection tray using the safety drain at the base of the appliance if necessary.

Condensation drain preparation

Safety drain to empty tray Condensation drain duct

page no. 10 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 11: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

1

2

3

4

A

B

1

1

2

A

B

3

4

2.5

NB: when laying the condensation drain pipe towards the outside, the internal pipe supplied with the appliance should be lined with anti-condensation insulating material with an internal diameter of 10 mm (see point 2 in the diagram).

The insulating material should be fitted up to the mouth of the external condensation drain pipe fixed in the wall.

Wall section

Insulation

Emergency drain

External condensation drain pipe

2.0 Conditioner

Ventilation hole

Insulation of the internal condensation drain pipe

Once the holes have been made, place the supplied plastic sheets inside them.Roll up the sheet and insert it in the hole, checking that the A junction line is pointing upwards.Use a cutter to remove any excess pipe.For the positioning of the external grids, it is recommended to apply sealant available with wall covering of the installation.

The shutters must be positioned with the flap in vertical.

Assembling air ducts and external shutters

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 11 of 32

Page 12: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

AB

C

2.6

12

3

2

1

3

A

BracketBracket anchoring points

Anti-lifting bracket

Junction line

After checking that the bracket is anchored to the wall and that all necessary electrical connections and condensation drain preparations have been made, you can mount the conditioner. Lift it by the sides of the bottom base until the bracket fits on all of the right spots on the appliance. In order to ease the operation, slightly tilt the appliance towards you. Direct electrical connections (disconnecting the power supply cable) and the anchoring of the condensation drain must be carried out after having spaced the appliance from the wall using a wooden wedge or any other similar

object.Once the work is done, check that there are no openings on the back of the appliance, especially where the air ducts are connected. To improve installation safety, the machine can be secured to the wall with a dedicated anti-lifting bracketwhich is located on the rear part of the machine. The drilling position is indicated on the installation template.

Mounting the appliance on the bracket

page no. 12 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 13: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

2.7

AB1

234

A

B

gri

gio

gre

y

grig

io

/ g

rey

bLu

/ b

lue

grig

io

/ g

rey

marr

on

e /

bro

wn

gia

llo-ve

rde /

yellow

-gre

en

2

1

3

4

3

The appliance is equipped with a power cord and plug (Y-type connection, the cord can only be replaced by the manufacturer, the assistance centre or a qualified installer). If using a socket near the appliance, simply insert the plug.

Before connecting the conditioner check that: - The power supply voltage and frequency values

comply with the data plate of the appliance.- The power supply line has a suitable earth connection

and that it is sized for the maximum absorption ofthe conditioner (minimum cable section equal to 1.5mm2).

- Power is only supplied using a suitable socket throughthe supplied plug.

If the supply cable is replaced, this must be done exclusively by the technical assistance service or by authorised personnel and in compliance with current national regulations.

The appliance must be connected to 230V/50 Hz mains via an omnipolar switch with a contact opening distance of minimum 3 mm, or using a device enabling the complete disconnection of the appliance in overvoltage III category conditions.

It is possible to carry out the electrical connection using a cable inside of the wall as indicated in the installation template (recommended for installations in the upper part of the wall).Please check that the power supply is provided with suitable protections against overloads and/or short-circuits (using a 10 Amp Time delay fuse or other equivalent devices is recommended).

To prevent any risk of electrocution, always disconnect the main circuit breaker before making electric connections or performing any maintenance on the units. To carry out direct connections and substitute the power cord using the cable in the wall, proceed as follows: - Remove the upper grill.- Remove the two plastic side panels, by lifting them

upwards.- Undo the front panel fixing screws.- Remove the front panel.- Disconnect the power cord by unscrewing the 3

screws from the terminal block.- Connect the wall cable, checking that the power

supply line has a suitable earth connection and that itis sized for the maximum absorption of the conditioner(minimum cable section equal to 1.5 mm2).

When the CP contact opens (very low voltage, connected to a free non-live contact) the appliance is put is stand-by and CP appears on the display.Using this contact, it is possible to connect an external device that inhibits the functioning of the appliance

such as: open window contact, on/off remote, infrared presence sensors, enabling badge, etc.We recommend using a double insulation cable.

CP occupancy contact input connection

230V/50 Hz Electrical power supply terminal blockCP contact presenceUpper grill

Supply gridFront panelFixing screws

Electrical connection

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 13 of 32

Page 14: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

2.8

The unit can be installed either in the lower part (near the floor) or in the upper part (near the ceiling) of the wall. In order to optimise air distribution and comfort, the direction of the air flow can be modified by adjusting the position of the air flap. The appliance is supplied ready to be installed in the lower part of the wall, so the air flow is directed upwards.The same configuration can also be used in the upper part of the wall in cooling mode, which increases the air flow in

the room (coanda effect).In this case, purchase the the lower cover decorative kit code GB0737.

This operation must be performed while the appliance is switched off and disconnected.

High/low installation configuration

page no. 14 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 15: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

2.10

2.13

2.11

2.9

2.12

Should any anomaly occur in the condensation water system, the maximum level float blocks the conditioner and the OF code appears on the display. During cooling and dehumidification, electronics keeps the water distribution system active with the battery - together with the fan - to disperse excess water in the container. If the problem persists, please contact the assistance

service.During heating, condensation should drain freely through the specific pipe. In the event of an alarm, check that the condensation pipe is not bent or obstructed, thus preventing the water from flowing out.

Evacuation of condensate water in the event of an emergency

If the presence contact is not closed, the appliance will not start and the CPalarm appears on the display.

The key lock is activated by keeping the Timer symbol on the touch-screen display pressed for three seconds. The user cannot perform any actions. The stand-by symbol flashes every second.

To deactivate the lock, keep the Timer symbol pressed for three seconds once again.The lock remains active also for the next operations performed via remote control and in the event of a power failure.

Press and hold the air exchange key ( ) for 10 seconds to enable the function ("En" displayed); the dehumidification and Auto functions are disabled (leaving active only ventilation, heating and cooling) and the settable set range

is reduced from 22 to 28 in cooling mode and from 16 to 24 in heating mode).

The display brightness sensor can be disabled (leaving the maximum brightness at all times) by pressing and holding

the night button ( ) for 10 seconds. "ds" (disabled) or "En" (enabled) will appear on the display.

Open CP contact

Touch-screen display key lock

Hotel function

Display indications Cause

E1 Faulty room temperature RT probe

E2 Faulty evaporative battery IPT probe

E3 Faulty outdoor air temperature OT probe

E4 Faulty conditioner battery OPT probe

E5 Faulty indoor air fan motor

E6 Faulty outdoor air fan

E7 Lack of communication with the display

E8 Compressor discharge probe failure (only for DC Inverter models)

If the conditioner blocks because of an alarm (see following table), please communicate to the assistance centre the

code on the display to facilitate interventions.

Detecting possible faults

It is possible to deactivate the heating or the cooling modes following a simple procedure.Keep the A key on the touch-screen display pressed for 5 seconds until HC (heating and cooling) appears on the display.Press the A key for 1 second to switch to the Co (cooling

only) mode.Press the A key again to switch back to Ho (heating only) mode.Wait for 3 seconds without touching anything to memorise the setting.

Setting cool only or heat only modes

Brightness regulation

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 15 of 32

Page 16: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

Objects or structural obstacles (furniture, curtains, plants, leaves, blinds, etc.) must not obstruct the normal air flow both from the internal and from the external grids.

Do not lean against, or worse sit on, the body of the conditioner, this would damage the appliance.

Do not move the horizontal air outlet flap manually. Always use the remote control to perform such operation.

In the event of water leaks, turn off the appliance and disconnect the electric power supply. Call the nearest service centre.

During heating mode, the conditioner eliminates periodically any ice formed on the external battery. In such situation, the machine keeps on working, but it does not dispense warm air to the room. This phase can last from 3 up to maximum 10 minutes.

The appliance must not be installed in rooms where explosive gases develop or where there are humidity and temperature conditions that exceed the maximum levels reported on the installation manual.

Clean the air filter regularly as described in the specific paragraph.

Before leaving the site, the packaging should be gathered up and all traces of dirt that have deposited on the unit during assembly should be eliminated with a damp cloth. These operations, which are not strictly necessary, in any case allow for a more professional appearance of the installation in the eyes of the user.

To avoid unnecessary calls by the user, before leaving the site it is also a good idea to: - outline the contents of the manual,- show them how to clean the filter,- explain when and how they should contact Customer

Service.

Use of the appliance

Operations after installation

page no. 16 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 17: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

3.1

1

2

3

MAINTENANCE

Disconnect the unit from the power supply before each cleaning and maintenance intervention by setting the main power supply switch to off.

Wait for the components to cool down in order to avoid any burns.

Pay attention to the sharp edges.

Do not use abrasive sponges or abrasive or corrosive detergents as you might damage the painted surfaces.

When necessary, clean the external surfaces with a soft damp cloth.

The air conditioner you have bought has been designed to keep maintenance operations to a minimum, in fact, they only include the following cleaning operations:Clean the air filter after a period of continuous use and according to the concentration of impurities in the air, or when you wish to start-up the appliance after a period of inactivity.NB: before performing any operation, take care with the hot and/or sharp surfaces of the metal.The filter is located in the top part of the appliance.

To extract the filter: - open the grille and carry out operations 1, 2, 3, then

remove it from its housing;- extract the filter by lifting it;- remove the dust from the filter with a vacuum cleaner

or by washing it in running water without usingdetergents or solvents and leave to dry;

- put the filters back on top of the coils, taking care toposition them correctly;

- put the grille back in reverse order.

After filter cleaning, check if the panel is properly mounted.

It is forbidden to use the device without its mesh filter.

The air conditioner you have bought has been designed to keep maintenance operations to a minimum, in fact, they

only include the following cleaning operations:

Periodic Maintenance

Cleaning the filters

External cleaning

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 17 of 32

Page 18: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

3.2

In the even of a malfunction, please refer to the following table. If, after performing the suggested checks, the problem is not solved,

please contact the authorised technical assistance.

An alarm code appears on the display in the event of faults. Some of the functions, however, remain active (see FUNCTIONING column).

* for DC Inverter models: lack of communication between the main,power, driver or display boards

The only way to solve the problem is to disconnect and reconnect the appliance. If the alarm still appears, please contact the authorised technical assistance.

Display alarms

Fault Possible causes Solution

The appliance doesn't switch on

No power supply

Check there is power supply (by turning a light on, for example).Check that the thermal-magnetic circuit breaker used exclusively to protect the appliance has not been tripped (if it has, reset it). If the problem repeats immediately, please call the Service Centre and avoid trying to make the appliance work.

Remote control batteries have run outCheck that the appliance can be turned on using the touch-screen display and substitute the batteries.

The appliance does not cool/heat adequately.

The temperature set is too high or too low.

Check and, if necessary, adjustthe temperature setting on the remote control

The air filter is clogged Check the air filter and clean it if necessaryCheck that there are no other obstacles to the air flow both inside and outside.

Remove anything that might block the air flow.

The heating and cooling load has increased (for example, a door or a window has been left open or an appliance has been installed in the room which generates a lot of heat).

Try to reduce the heating and cooling load of the room following instructions below: Cover large windows exposed to sunlight with curtains or with external maskings (blinds, porches, reflecting films, etc.);The air conditioned room must remain closed for as long as possible;Avoid turning on halogen lamps or other high energy consumption appliances such as small ovens, steam irons, hot plates etc.).

Alarm Cause Operation

E1Faulty room temperature RT sensor

It is still possible to activate Cooling, Dehumidification and Heating modes. It only monitors the antifreeze function of the internal coil.

E2 Faulty internal coil IPT sensor None of the modes can be activated.

E3Faulty outside temperature OT sensor

None of the modes can be activated.

E4Faulty external coil OPT sensor

It is still possible to activate Cooling, Dehumidification and Heating modes. Defrosting is performed at fixed times.

E5 Faulty internal fan motor None of the modes can be activated.E6 Faulty external fan motor None of the modes can be activated.

E7Lack of communication with the display *

None of the modes can be activated.

E8Compressor discharge probe failure *

None of the modes can be activated.

CP Open CP contactThe appliance only works if the contact is closed. Check that the clamps are connected.

OFMaximum level float intervention

During cooling and dehumidification, electronics keeps the water distribution system active with the battery - together with the fan - to disperse excess water in the container. During heating, condensation should drain freely through the specific pipe. In the event of an alarm, check that the condensation pipe is not bent or obstructed, thus preventing the water from flowing out.

Troubleshooting

page no. 18 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 19: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

3.3

(1) DB 27°C - WB 19°C DB 35°C - WB 24°C

(2) DB 20°C - WB 15°C DB 7°C - WB 6°C

(3) DB 20°C - WB 15°C DB -7°C - WB -8°C

(4)

(5)

DB 32°C DB 43°C

DB 18°C DB -5°C

DB 25°C DB 18°C

DB 5°C DB -10°C

kW 2.35

kW 3.11

kW 0.92

kW 2.36

kW 1.11

kW /

kW 3.05

kW 0.79

W 855

W 750

L/h 0.9

V-F-Hz 230-1-50

W/W 2.75

W/W 3.15

A

A

No. 3

m³/h 400/480

m³/h 320/390

m³/h 270/340

mm 500x1398x185

kg 53.0

dB(A) 27/41

dB(A) 45/58

mm 162

mm 293

R410A

Technical specifications

Please read data plate to obtain the technical data listed below. - Power supply voltage- Maximum absorbed power- Maximum absorbed current- Amount of refrigerant gas- Casing protection rating

* with Dual Power function activated during heating

Room T External T

Cooling mode tests (EN 14511)

Heating mode tests (EN 14511)

Heating mode tests

Internal side sound pressure measured in semi-anechoic chamber at a distance of 2 m.

Internal side sound pressure measured in accordance with regulation EN 12012

Internal ambient temp. External ambient temp.

Maximum operating temperature in cooling mode

Minimum operating temperature in cooling mode

Maximum operating temperatures in heating mode

Minimum operating temperatures in heating mode

Operating limits

Reference conditions

Technical specifications

Cooling power (1)

Power in max cooling mod. Dual Power

Power in min cooling mod. Dual Power

Heating power (2)

Heating power (3)

Additional power electrical resistance

Power in max heating mod. Dual Power

Power in min heating mod. Dual Power

Power absorbed when cooling (1)

Power absorbed when heating (2)

Dehumidification capacity

Power supply voltage

EER

COP

Energy efficiency class when cooling

Energy efficiency class when heating

Internal-external ventilation speed

Internal/external air flow at max speed

Internal/external air flow at medium speed

Internal/external air flow at min speed

Dimensions (WxHxD)

Weight including packaging

Sound pressure level (min-max) (4)

Unit sound power level inside (min-max) (5)

Wall holes diameter

Wall holes distance

Refrigerant gas

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 19 of 32

3.1 DC Inverter

Page 20: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

4.1

4.2

USER MANUAL

Warnings

Managing the appliance with the touch-screen display and the remote control

Objects or structural obstacles (furniture, curtains, plants, leaves, blinds, etc.) must not obstruct the normal air flow both from the internal and from the external grids.

It is strictly forbidden to place any containers on top of the appliance, especially if they contain liquid. This could trigger a short-circuit, damage the appliance and/or expose the user to the risk of electrocution.

Do not lean against, or worse sit on, the body of the conditioner, this would damage the appliance.

Do not move the horizontal air outlet flap manually. Always use the remote control to perform such operation.

In the event of water leaks, turn off the appliance and disconnect the electric power supply. Call the nearest service centre.

During heating mode, the conditioner eliminates periodically any ice formed on the external battery. In such situation, the machine keeps on working, but it does not dispense warm air to the room. This phase can last from 3 up to maximum 10 minutes.

The appliance must not be installed in rooms where explosive gases develop or where there are humidity and temperature conditions that exceed the maximum levels reported on the installation manual.

Clean the air filter regularly as described in the specific paragraph.

Normally, the display shows the operating status (see paragraph entitled Description of operations), as well as any alarms (see paragraph entitled Display alarms).

In addition, it is possible to select the various functions by pressing the symbols.

1 Corresponding button on remote control2 Corresponding button on touch-screen display

BUTTON / DISPLAY:

Setpoint Heating only button (2)

Up button Nocturnal well-being button

Down button Control of air flow direction button

On/off button Fan speed control button

Well-being button (economic automatic mode) Timer mode setting button (1)

Cooling only mode button Timer mode setting button (2)

Dehumidification only mode button Brightness sensor

Ventilation only mode button Digital thermometer; 1÷7 red bars in winter, blue bars in summer

Heating only button (1) Not used

page no. 20 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 21: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

4.3 Description of operations

It is possible to select the various modes by pressing the buttons (see paragraph entitled Description of operations).

The remote control provided has been designed to be functional and hard-wearing, however, it must be handled cautiously.

Avoid:- leaving it exposed to rain, pouring liquids on it or

dropping it into water- hitting it or dropping it on hard surfaces- leaving it under the sun

- placing obstacles between the remote and theappliance while using it.

In addition:- if there are other appliances using remote controls in

the room (TV, radios, stereos, etc.), interferences mayoccur

- electronic or fluorescent lamps can interfere withcommunication between the remote and the appliance

- remove the battery if not using the remote for a longtime.

Only CR2012 3V dry lithium batteries must be used (supplied). Used batteries must be handed over to the specific collection areas as arranged by the Local Authorities for this type of waste.In order to insert the batteries, open the specific cover

in the bottom part of the remote. The battery must be inserted respecting polarity. Once the battery is inserted, close the cover.

In order to manage the appliance using the remote control and the touch-screen, the main switch on the electrical power supply line must be turned on (its exact position can be indicated by the technician who installed the appliance) or the power supply plug must be connected to the system socket. Once such operations have been performed, it is possible to manage the system by holding down the symbols on the

touch-screen (for 3 seconds) or by using the remote control. In order to send commands to the internal unit, the top part of the remote must point towards the display of the internal unit. The reception of the command is confirmed by a beep and by the display. The maximum distance for the remote control to work is approximately 8 metres.

General start-up and management

Battery insertion

Key/Display Operation

The keys of the remote control and of the touch screen display perform the same functions.

When the unit is turned on, the 3 digits on the display will show the set-point.

• It is possible to set the set-point between 16 and 31°C, to which temperature the unit will bring the room.

If the temperature is set too low or too high, not only it is unhealthy, but it is also an unnecessarywaste of energy.

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 21 of 32

Page 22: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

Key/Display Operation

Switching the appliance on and off

It is possible to switch the appliance on or off (stand-by) by pressing the specific button. The control system of the appliance is equipped with a memory, so settings will not be lost if the appliance is switched off or in the power supply is cut. This key is used to activate or deactivate the appliance for short periods of time.

In case of long periods of inactivity, the appliance must be deactivated by disconnecting either the main switch or the plug from the socket.

Well-being button (economic automatic mode)

By choosing this mode on the appliance, it sets the best level of comfort in the room. The conditioner selects the mode automatically (cooling or heating) according to the temperature set and ventilation speed according to the temperature of the room.

Cooling only mode

• In this mode, the appliance dehumidifies and cools the room.

• It is possible to set the desired temperature between 16 and 31°C and, if this temperature is lower than the roomtemperature, the compressor starts up after three minutes (maximum) and the appliance starts dispensing coolair, maintaining ventilation active even if the setpoint has been reached.

Dehumidification only mode

In this mode, the appliance dehumidifies the room. Selecting this mode is useful during mid-seasons, i.e. on days (e.g. rainy ones) when the temperature is pleasant, but excess humidity causes discomfort. This mode ignores both room temperature and ventilation speed settings.The latter is always set to a minimum. It is normal for the appliance to work intermittently.

Ventilation only mode

By selecting this function, the compressor is never activated and the appliance does not affect either room temperature or humidity. IT IS possible to choose the speed of the fan

Heating only mode

• In this mode, the appliance heats the room.

Set on heating only mode, the appliance periodically defrosts the evaporator coil, if necessary. During this phase,the conditioner does not dispense warm air, even if its internal components are on, except for the room fan.

• It is possible to set the desired temperature between 16 and 31°C and, if such temperature is higher than theroom temperature, the compressor starts up after three minutes (maximum) and the appliance starts dispensingwarm air.

Nocturnal well-being button

While the appliance is on in the selected cooling or heating mode, it is possible to choose different functions by pressing the button in order to maximise noise reduction, energy saving and nocturnal well-being regulation. In this mode, ventilation is set on minimum speed.This mode should be activated right before going to sleep.• In cooling mode, the set temperature is increased by 1°C after one hour and by another degree after two. After

the second hour, the temperature is no longer changed and, after six hours, the appliance is put in stand-by.• In heating mode, the set temperature is lowered by 1°C after one hour and by another degree after two. After the

second hour, the temperature is no longer changed and, after six hours, the appliance is put in stand-by.This function is not available for dehumidification only, ventilation only and economic automatic modes and can be excluded any time (ideally once awake) by pressing the button again. If the Timer has also been set, the appliance will turn off at the set time.

Control of air flow direction

By pressing the specific button, it is possible to either select the continuous oscillation of the mobile air outlet flap - in such case, the symbol on the display is lit - or to block it in any position.

IMPORTANT: The mobile flap must never be moved manually. In cooling and dehumidification modes, the position of the flap is reset every 30 minutes to prevent dew from forming.

page no. 22 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 23: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

Key/Display Operation

Fan speed control (models 8 and 10)

By pressing this button several times, the speed will change according to the following sequence: Minimum, Medium, Maximum and AutomaticThe higher the speed is set, the better the appliance will perform, but it will be less quiet. By selecting Automatic mode (shown by three speed bars moving up and down on the display), the on-board microprocessor automatically adjusts the speed, so that it stays higher the greater the difference between the temperature detected and the temperature set. The speed will always be automatically decreased as the room temperature approaches the set temperature. This is not possible in humidification only or nocturnal well-being mode where the appliance can only operate at a low speed.

Setting power for models inverter 10HP and 12HP

By pressing this key sequentially, it is possible to set the power supplied by the appliance on 5 adjustments: Minimum, Medium, Maximum, Dual Power and Automatic.The higher the power is set, the better the appliance will perform, but it will be less quiet.The Dual Power function (shown by three flashing speed bars on the display and the seven red or blue bars moving up and down of the digital thermometer), available only in heating and cooling mode, supplies a 30-minute Overboost.Then, the controller inhibits the function and switches to automatic mode. By selecting Automatic mode (shown by three speed bars moving up and down on the display), the on-board microprocessor automatically adjusts the speed, so that it stays higher the greater the difference between the temperature detected and the temperature set. This is not possible in humidification only or nocturnal well-being mode where the appliance can only operate at a low speed.

Setting the Timer function

• The appliance allows the user to program when to turn it on and off, as required.

• While the conditioner is running, it is possible to schedule when it turns off by pressing the Timer button, followedby the number of hours (from 1 to 24), after which the unit will be put in stand-by.

• When the air conditioning unit is off, it is possible to schedule when it turns on by pressing the Timer button,followed by the number of hours (from 1 to 24) after which the unit will start.

• Then, press the confirm button.

Touch-screen display key lock

• The key lock is activated by keeping the Timer symbol on the touch-screen display pressed for three seconds.The user cannot perform any actions. The stand-by symbol flashes every second.

• To deactivate the lock, keep the Timer symbol on the touch screen pressed for three seconds once again.

The lock remains active in the case of a power failure and also if the remote control is used!

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 23 of 32

Page 24: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

4.4

4.5

4.6

4.7

The key lock is activated by keeping the Timer symbol on the touch-screen display pressed for three seconds. The user cannot perform any actions. The stand-by symbol flashes every second.

To deactivate the lock, keep the Timer symbol on the touch screen pressed for three seconds once again.The lock remains active also for the next operations performed via remote control and in the event of a power failure.

Press and hold the air exchange key ( ) for 10 seconds to enable the function ("En" displayed); the dehumidification and Auto functions are disabled (leaving active only

ventilation, heating and cooling) and the settable set range is reduced from 22 to 28 in cooling mode and from 16 to 24 in heating mode).

The display brightness sensor can be disabled (leaving the maximum brightness at all times) by pressing and holding

the night button ( ) for 10 seconds. "ds" (disabled) or "En" (enabled) will appear on the display.

Touch-screen display key lock

Hotel function

It is possible to deactivate the heating or the cooling modes following a simple procedure.Keep the A key on the touch-screen display pressed for 5 seconds until HC (heating and cooling) appears on the display.Press the A key for 1 second to switch to the CO (cooling

only) mode.Press the A key again to switch back to HO (heating only) mode.Wait for 3 seconds without touching anything to memorise the setting and return to normal operations.

Setting cool only or heat only modes

Brightness regulation

page no. 24 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 25: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

4.8

4.9

Suggestions for power saving

Diagnosis of problems

- Always keep the filters clean (see maintenance andcleaning chapter).

- Keep the doors and windows of the rooms to be airconditioned closed

Do not let direct sunlight to enter the room (use curtains or lower the blinds or close the shutters)

- Do not block the air flow paths (input and output)of the unit; this, as well as causing a non-optimalperformance of the unit, will jeopardise the correctoperation of the same and may cause irreparabledamage to the units.

For the User it is very important to distinguish any inconveniences or abnormal operation of the unit compared to its normal operation. Also, the most common problems can be easily solved by means of simple operations performed by the User (See paragraph: Troubleshooting), while for some alarms signalled on the

display, it is necessary to contact Customer Service.

We also remind you that any attempt to repair the unit on part of unauthorised technicians will void the warranty immediately.

- The compressor will not restart before a certain time haspassed (about three minutes from the previous stop). It isnot possible to stop and restart the compressor withoutwaiting at least three minutes. This is provided for in theoperating logic of the unit, so as to protect the compressor from frequent activations.

- During operation in heating mode, the warm air is delivered a few minutes after the activation of the compressor. If thefan started at the same time as the compressor, in the firstminutes of operation the air delivered would be too cold(which may disturb the occupants of the room) since theunit is not yet ready.

If the remote control has been lost, the batteries are exhausted or it no longer works, the unit can be operated by using the keys on the touch screen display on the machine.

Operating aspects that should not be interpreted as problems

Using the unit if the remote control is not available

Should any anomaly occur in the condensation water system, the maximum level float blocks the conditioner and the OF code appears on the display. During cooling and dehumidification, electronics keeps the water distribution system active with the battery - together with the fan - to disperse excess water in the container. If the problem persists, please contact the assistance

service.During heating, condensation should drain freely through the specific pipe. In the event of an alarm, check that the condensation pipe is not bent or obstructed, thus preventing the water from flowing out.

Evacuation of condensate water in the event of an emergency

If the presence contact is not closed, the appliance will not start and the CPalarm appears on the display.

Open CP contact

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 25 of 32

Page 26: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

5.1

AIR CONDITIONING APP OPERATION

Minimum system requirements

1. The download and installation of the App depends onsome system requirements of your smartphone.

2. For Android smartphones, the minimum version is 4.1.1

3. For Apple smartphones, the operating system must be IOS 8.0 or higher.

Figure 2-1

Press the button as shown in the figure to start the automatic procedure for the recognition and WIFI connection on the air conditioner network. (only on Android devices).If the automatic procedure does not start, it can be configured manually as indicated below.

On the first screen it is possible to select the language preference and the way the push notifications are handled.

If you check the notification box, the alarms will appear on your smartphone.

Figure 2-2

5.2 Installing and using the APP

1. From the application menu on your smartphone, find and open the "play store" icon.

2. Once you have logged into the store, search for InnovApp DuePuntoZero

3. Once you have found InnovApp 2.0, download the App and install it following the wizard.

4. Open the App. Once open, the screen in Figure 2-1will appear

page no. 26 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 27: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

Figure 2-3 Figure 2-4

Figure 2-5 Figure 2-6

Figure 2-8Figure 2-7

After activating the WIFI mode through the phone settings, access the available WIFI connection section, check for the presence of the air conditioner network and connect to it.

N.B.: with Android devices the procedureabove is automatic, but for IOS devices youhave to edit main settings of your phone /tabletand select the "Innova2.0" network on networksettings.

Once connected to the WIFI network of the device, the screen of your product will appear and you will be able to name it and indicate its serial number, consisting of 9 alphanumeric characters as shown in the figure.

By entering the password, the stand alone air conditioner network will be protected from unauthorised access.

N.B.: for IOS devices, after 2.0 label appliance,the WiFi network will automatically changefor find a network with Internet access. Sois necessary to edit another time the phonenetwork settings and reconnect to the new2.0 label just named, e.g. "Vision 2.3".

If you go back to the main menu and access the menu "My products", the air conditioner units in the network will be displayed and can be changed and/or scheduled as you wish.

Moreover, new devices can be searched for, installed and configured as in Figura 2-18 3.

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 27 of 32

f you go back to the main menu and access the menu "My products", the air conditioner units in the network will be displayed and can be changed and/or scheduled as you wish.

Moreover, new devices can be searched for, installed and configured as in Figure 2-18 3.

Page 28: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

Figure 2-11

Once you entered the WIFI connection menu, choose the network preferred for Internet access and select it.

Figure 2-12

Figure 2-9

At this point, a general air conditioner control screen will appear, by means of which you can control and manage your air conditioner 2.0.

N.B.: from now on you will have the possibilityto control the air conditioner via the local WIFInetwork, but not via Internet.

To do this, it is necessary to take a further step and connect to the home/office WIFI network by accessing the settings as in the figure on the right and selecting the option "Remote Control".

Figure 2-10

Figure 2-13

Then enter the password of your WIFI network and confirm it.

N.B.: on password label are available onlyalpha numeric characters, not special ones.

Figure 2-14

page no. 28 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 29: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

Figure 2-17 Figure 2-18

Figure 2-19

From the main screen of the selected conditioner, it is possible to change the operating mode from manual to automatic and then access the timer as shown in the figures.

Figure 2-20

Figure 2-15

At this point the 2.0 App will attempt to connect your unit to your home network; thus, smartphone air conditioner main screenshot for the management of the unit will appear again.

From now on, your 2.0 is connected to the server trough Internet network, and can be managed from all over the world via WIFI or your phone's data connection!

If the procedure fault, smartphone/tablet will automatically connect to 2.0 local network.In this case, repeat the procedure by checking password and network label.

Click on the edit key as indicated to change the operating mode of the air conditioner.

Figure 2-16

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 29 of 32

Page 30: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

Figure 2-21

Follow the procedure indicated above to add on and off times during the day.

It is possible to program multiple on and off times with minimum intervals of thirty minutes in the same day.

If you want to repeat these periods in other days of the week, it will be possible by following the instructions shown in the figures below.

Figure 2-22 Figure 2-23

Figure 2-24 Figure 2-25 Figure 2-26

page no. 30 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Page 31: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

Figure 2-27

After finishing the programming operation, the screen of the operating mode will be as in Figure 2-27 3.

If we then go back to the main screen of the air conditioner as in Figure 2-28 at the bottom, the time of the first start-up of the air conditioner will be displayed if the off time is scheduled.

Figure 2-28

COUPLING 2.0 WITH NEW SMARTPHONE OR TABLET

After 2.0 configuration with smartphone, it is possible to control the unit with another device (smartphone or tablet); the quick procedure is the following.

You shall to connect to the same network of 2.0 just configured;

Download and install “InnovApp DuePuntoZero” apllication from store. Open the app and press to "start" button (Figure 2-2).

Now the smartphone will tell you that you are not connected to the right WiFi network and you shall connect to “Innova2.0” network: ignore the warning and click to “devices” under loading menu.

Now the phone, if you are connecteed to same WiFi network where is also connected the 2.0 air conditioner, will automatically scan all the 2.0 available on network.

Once your device found, will be opened the “2.0” menu; now you can cocontrol the 2.0 also with the second tablet/amartphone.

To add new 2.0, select the menu key on the left of your screen (“my devices” settings) and click “+” key that appear on top and right of your screen.

Now two lanels will appear: “find new devices”, “manual add”); select “find new devices”; so the smartphone will search new air conditioners another time.

WIFI NETWORK RESET

With “reset” function is possible to resume the configuration from begin with a few steps :

• check if air conditioner is powered Off;

• Hold down the key for 5 seconds. When “On” label appears, release the key.

• Press key another time to change WiFi status(On,Rst,Off). The needed setting will be activatedautomatically after 10 seconds without selections.

• If we leave “On” blinking, the Wi-Fi network will beactive and you can see the 2.0 with the last WiFiname set.

• Leaving “Off” setting, the 2.0 Wi-Fi will switch offand it will not visible by smartphone/tablet.

• Leaving “Rst” setting, the 2.0 WiFi network backto default setting named "Innova2.0"; so you willhave to configure the air conditioner from Figure 2-3indications.

Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018. page no. 31 of 32

Page 32: Apr Contact Us Paul Greenough AIr Conditioning Product ... · the best choice. By choosing Powrmatic, you are investing in UK manufacturing & its workforce. We pride ourselves by

0 powrmatic

page no. 32 of 32 Vision VertiCool 3.1 Users, Installation & Servicing Instructions Doc Ref M602 issue 1.1 Apr 2018.

Hort BridgeIlminster, Somerset TA19 9PS

Tel: 01460 53535Fax: 01460 52341

Every effort is made to ensure accuracy at time of going to press. However as part of continued product improvement, we reserve the right to alter specification without prior notice.

More information is available from our web site on:-

http://www.powrmatic.co.uk/products/air-conditioning/browse/view/product/vision-2-3/