Page 1: APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices...APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices Sales Presentation - CPU to CPU Communication on PROFINET RT

APR/ACP, NOVEMBER 2017

CM589-PNIO (-4) (-XC) IO devicesSales Presentation - CPU to CPU Communication on PROFINET RT

Page 2: APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices...APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices Sales Presentation - CPU to CPU Communication on PROFINET RT

– Material handling (Distribution centers, airports, harbors, etc. )

• AGVs (Automated Guided Vehicles)

• Cranes

• Hoists, etc.

– Robot applications

• Robot cells (B&W, press, laser cutting, etc.)

– Winder applications (Metals, Pulp&Paper, etc.)

– Various process automation applications

• Hydrogen tank stations

• Boilers

• Burner Management Systems, etc.

Typical customer applications

November 14, 2017 Slide 2

CM589-PNIO (-4) (-XC) PROFINET IO device

Page 3: APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices...APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices Sales Presentation - CPU to CPU Communication on PROFINET RT

– PROFINET IO device functionality for all existing AC500 CPUs

• CM589-PNIO (-XC) to communicate with 1 PROFINET IO controller

• CM589-PNIO-4 (-XC) to communicate with up to 4 PROFINET IO controllers

– Internal Ethernet switch with 2 ports

– Transfer rate of 10/100 MBit/s in full duplex mode

– 5 status LEDs

– 2 rotary switches for PROFINET name setting – easy engineering

• One PM5xx CPU boot project will work on different machines with unique PROFINET address setting (unique PROFINET names)

– Automation Builder (AB)

• CM589-PNIO (-XC) is supported from AB 1.1 and PM5xx CPU FW V2.4.0

• CM589-PNIO-4 (-XC) is supported from AB 2.1 and PM5xx CPU FW V2.7.0

Hardware and Firmware

November 14, 2017 Slide 3

CM589-PNIO (-4) (-XC) Features

Page 4: APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices...APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices Sales Presentation - CPU to CPU Communication on PROFINET RT

– CM589-PNIO, 1SAP172901R0011, standard version and CM589-PNIO-XC, 1SAP372901R0011, eXtreme Condition versions

• PROFINET IO device functionality to communicate with 1 PROFINET IO controller

– CM589-PNIO-4, 1SAP172900R0111, standard version and CM589-PNIO-4-XC, 1SAP372901R0011, eXtreme Condition versions

• PROFINET IO device functionality to communicate with up to 4 PROFINET IO controllers

• The same PROFINET name and IP address is used for all PROFINET IO controllers

• Up to 4 different VLANs are supported simultaneously

– Communication with 3rd party PROFINET IO controllers (GSDML file is available for download) at www.abb.com/plc

– PROFINET standard diagnosis is supported

Hardware and Firmware

November 14, 2017 Slide 4

CM589-PNIO (-4) (-XC) Features

Page 5: APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices...APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices Sales Presentation - CPU to CPU Communication on PROFINET RT

– Simple configuration steps in Automation Builder to implement the communication

• No programming efforts for process data transfer

– Up to 1440 bytes of cyclic input and 1440 bytes of cyclic output data

• Standard process data and functional safety data

• The data volume is configurable using BYTE and WORD data segments

• CM589-PNIO-4 (-XC) - data can be split between up to 4 supported PROFINET IO controllers

• Functional safety data are part of “Black Channel” for PROFIsafe protocol

Easy Engineering

November 14, 2017 Slide 5

CM589-PNIO (-4) (-XC) Features

Page 6: APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices...APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices Sales Presentation - CPU to CPU Communication on PROFINET RT

– Generic applications

• Remote or distributed control solutions to improve productivity and reduce downtimes

• Faster reaction times on events using real-time PROFINET RT communication

• WLAN for real-time PROFINET RT communication to mobile machines

• 3rd party PN/PN couplers/gateways are not needed any more (save costs and space in control cabinets)

– eXtreme Condition applications

• Operating temperature from -40°C … up to +70°C

• Freezing climate, high humidity, high altitude up to 4000 m (Air pressure: 620 hPa)

• Corrosive gases, salt mist and dust

• Large vibration ranges and extended EMC requirements

Application Areas and Customer Benefits

November 14, 2017 Slide 6

CM589-PNIO (-4) (-XC) Features

Page 7: APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices...APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices Sales Presentation - CPU to CPU Communication on PROFINET RT

Many slave CPUs with CM589-PNIO (-XC) to 1 master CPU with CM579-PNIO (-XC)

November 14, 2017 Slide 7

CPU to CPU Communication using CM589-PNIO (-XC)

CM579-PNIO -PROFINET IO

controller 1 (Master)

CM589-PNIO -PROFINET IO device 1

(Slave)

CM589-PNIO -PROFINET IO device 2

CM579-PNIO -PROFINET IO

controller

e.g., CI506-PNIO -PROFINET IO device(s)

CM579-PNIO -PROFINET IO controller 1

CM579-PNIO -PROFINET IO controller 1

CM589-PNIO (-XC) PROFINET IO device

Page 8: APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices...APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices Sales Presentation - CPU to CPU Communication on PROFINET RT

Many slave CPUs with CM589-PNIO-4 (-XC) to up to 4 master CPUs with CM579-PNIO (-XC)

November 14, 2017 Slide 8

CPU to CPU Communication using CM589-PNIO-4 (-XC)

CM579-PNIO -PROFINET IO

controller 1 (Master)

CM589-PNIO-4 -PROFINET IO device 1

(Slave)

CM589-PNIO-4 -PROFINET IO device 2

CM579-PNIO -PROFINET IO

controller

CM579-PNIO -PROFINET IO

controller 2 (Master)

CM579-PNIO -PROFINET IO

controller 3 (Master)

CM579-PNIO PROFINET IO

controller 4 (Master)

CM579-PNIO -PROFINET IO

controllers 1 .. 4

CM579-PNIO -PROFINET IO

controllers 1 .. 4

e.g., CI506-PNIO -PROFINET IO device(s)

CM589-PNIO-4 (-XC) PROFINET IO device

Page 9: APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices...APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices Sales Presentation - CPU to CPU Communication on PROFINET RT

Mixed configuration using slave CPUs with CM589-PNIO (-4) (-XC) modules

November 14, 2017 Slide 9

CPU to CPU Communication using CM589-PNIO (-4) (-XC)

CM589-PNIO-4 -PROFINET IO device 1

(Slave)

CM589-PNIO-4 -PROFINET IO device 2

CM579-PNIO -PROFINET IO

controller

e.g., CI506-PNIO -PROFINET IO device(s)

CM579-PNIO -PROFINET IO

controller 1 .. 4

CM579-PNIO -PROFINET IO

controller 1 .. 4

CM589-PNIO (-4) (-XC) PROFINET IO device

CM589-PNIO -PROFINET IO device 3

CM579-PNIO -PROFINET IO controller 4

CM579-PNIO -PROFINET IO

controller 1 (Master)

CM579-PNIO -PROFINET IO

controller 2 (Master)

CM579-PNIO -PROFINET IO

controller 3 (Master)

CM579-PNIO PROFINET IO

controller 4 (Master)

Page 10: APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices...APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices Sales Presentation - CPU to CPU Communication on PROFINET RT

– PROFINET IO device functionality for all existing AC500 CPUs

• CM589-PNIO (-XC) to communicate with 1 PROFINET IO controller

• CM589-PNIO-4 (-XC) to communicate with up to 4 PROFINET IO controllers

– Real-time CPU to CPU Communication on PROFINET RT with big data volumes

• Up to 1440 bytes of cyclic input and 1440 bytes of cyclic output data for standard process data and functional safety data

• Communication with 3rd party PROFINET IO controllers

– Simple configuration steps in Automation Builder to implement the communication

• No programming efforts for process data transfer

– Easy engineering – 2 rotary switches for PROFINET name setting

• One PM5xx CPU boot project will work on different machines with unique PROFINET address setting (unique PROFINET names)

Summary and Sales Arguments - CPU to CPU Communication on PROFINET RT

November 14, 2017 Slide 10

CM589-PNIO (-4) (-XC) PROFINET IO device

Page 11: APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices...APR/ACP, NOVEMBER 2017 CM589-PNIO (-4) (-XC) IO devices Sales Presentation - CPU to CPU Communication on PROFINET RT

– Material handling (Distribution centers, airports, harbors, etc.), robot applications and various process automation applications

• Remote or distributed control solutions to improve productivity and reduce downtimes

• Faster reaction times on events using real-time PROFINET RT communication

• WLAN for real-time PROFINET RT communication to mobile machines

• eXtreme Conditions version (Extended temperature, pressure, altitude, etc.)

• 3rd party PN/PN couplers/gateways are not needed any more (save costs and space in control cabinets)

Customer benefits - CPU to CPU Communication on PROFINET RT

November 14, 2017 Slide 11

CM589-PNIO (-4) (-XC) PROFINET IO device