aqua rite pro · 2017. 11. 7. · aquarite pro senses the pool's orp and ph levels and...

24
Hayward Pool Products 620 Division Street, Elizabeth NJ 07207 www.hayward.com Contents Operation..............................2 Installation.......................14 Troubleshooting..................20 Warranty..............................22 Aqua Rite Pro Electronic Chlorine Generator Owner's Manual AQR15-PRO AQR15-PRO-SD 092544 RevA USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Upload: others

Post on 20-Sep-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

Hayward Pool Products620 Division Street, Elizabeth NJ 07207

www.hayward.com

ContentsOperation..............................2

Installation.......................14

Troubleshooting..................20

Warranty..............................22

Aqua Rite ProElectronic Chlorine Generator

Owner's Manual

AQR15-PROAQR15-PRO-SD

092544 RevA

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 2: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

IMPORTANT SAFETY INSTRUCTIONS

• READANDFOLLOWALLINSTRUCTIONS

• WARNING–Toreducetheriskofinjury,donotpermitchildrentousethisproductunlesstheyarecloselysupervisedatalltimes.

• Awirebondinglugisprovidedonthelowerexternalsurface(twoforCanadianmodels)ofthisunittoconnectaminimum8AWG(8.4mm2)solidcopperconductorbetweenthisunitandanymetalequipment,metalenclosuresofelectricalequipment,metalwaterpipe,orconduitwithin5feet(1.5m)tyingtheunittothelocalbondinggrid.

• UseCopperConductorsOnly

• DisconnectallACpowerduringinstallation.

• Agreencoloredterminalmarked“Ground”islocatedinsidethewiringcompartment.Toreducetheriskofelectricshock,thisterminalmustbeconnectedtothegroundingmeansprovidedintheelectricsupplyservicepanelwithacontinuouscopperwireequivalentinsizetothecircuitconductorssupplyingtheequipment.

• Allfield installedmetalcomponentssuchasrails, ladders,drains,orothersimilarhardwarewithin3metersofthepool,spaorhottubshallbebondedtotheequipmentgroundingbuswithcopperconductorsnotsmallerthan8AWGUS/6AWGCanada.

• NOTICETOUSERS:Thiscontrolproductistobeusedonlyinaccordancewiththedirectionsofthislabel.ItisanoffenseunderthePestControlProductsActtouseacontrolproductunderunsafeconditions.

• SAVE THESE INSTRUCTIONS

1

USE ONLY HAYWARD GENUINE REPLACEMENT PARTSUSE ONLY HAYWARD GENUINE REPLACEMENT PARTSUSE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 3: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

OperationTheAquaRiteProisanautomaticchlorinegenerationsystemforpoolorspasanitization.Theoperationrequiresalowconcentrationofsalt(sodiumchloride)inthepoolwater.Theselevelsarelowenoughthatitnormallywillnotbetasted.TheAquaRiteProautomaticallysanitizesyourpoolbyconvertingthesaltintofreechlorinewhichkillsbacteriaandalgaeinthepool.Chlorinewillrevertbacktosodiumchlorideafterkillingbacteria.Thesereactionswillcontinuouslyrecyclevirtuallyeliminatingtheneedtoaddsanitizingchemicalstoyourpool.Theonlytimeyoumayneedtoaddmoresalttothepooliswhenwaterisreplenishedduetobackwashing,draining,orsplashing(notevaporation).

TheAquaRiteProisdesignedtohandlethepurificationneedsofmostresidentialswimmingpoolsupto40,000gallons(150,000liters),ortheneedsofmostcommercialpoolsupto25,000gal-lons(95,000liters).Checklocalcodesforotherrestrictions.Theactualamountofchlorinationrequiredtoproperlysanitizeapoolvariesduetobatherload,rainfall,temperature,andthepool'scleanliness.

TheAquaRiteProisavailableintwomodels:

AQR15-PRO-forpoolsupto40,000gallonsAQR15-PRO-SD-forpoolsupto40,000gallons,includesSense&Dispense

Note that the installation and mounting requirements are the same for all models.

TheAquaRiteProcanbeusedwiththeHaywardAQL-CHEM(includedwithAQR15-PRO-SD)toprovideafullyintegratedchemistrysolutionforyourpool.WiththeAQL-CHEMinstalled,theAquaRiteProsensesthepool'sORPandpHlevelsandautomaticallygeneratesthecorrectamountofchlorinetokeepyourpoolproperlysanitized.TheAquaRiteProcanalsocontrolpHbyintro-ducingacidorCO

2intothepoolusinganAQL-CHEM2(120V),AQL-CHEM2-240(240V)orother

dispensingdevicerequiring120VACor240VACon/offcontrol.TheAquaRiteProandAQL-CHEMproductsoffertheuseracompleteautomatedsystemcontrollingbothsanitizationandpHbalance.

NOTE: Hayward does not recommend using the AquaRite Pro to generate bromine.

NOTE:Beforeinstallingthisproductaspartofasalinewaterpurificationsysteminapoolorspausingnaturalstoneforcopingorforimmediatelyadjacentpatios/decking,aqualifiedstoneinstal-lationspecialistshouldbeconsultedregardingtheappropriatetype,installation,sealant(ifany)andmaintenanceofstoneusedaroundasalinepoolwithelectronicchlorinegeneratorinyourparticularlocationandcircumstances.

NOTE:Theuseofdryacid(sodiumbisulfate)toadjustpoolpHisdiscouragedespeciallyinaridre-gionswherepoolwaterissubjecttoexcessiveevaporationandisnotcommonlydilutedwithfreshwater.Dryacidcancauseabuildupofby-productsthatcandamageyourchlorinatorcell.

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

2

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 4: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

WaterChemistryThetablebelowsummarizesthelevelsthatarerecommendedbyTheAssociationofPoolandSpaProfessionals(APSP).TheonlyspecialrequirementsfortheAquaRiteProarethesaltlevelandstabilizer.Itisimportanttomaintaintheselevelsinordertopreventcorrosionorscalingandtoensuremaximumenjoymentofthepool.Testyourwaterperiodically.YourauthorizedAquaRiteProdealerormostpoolstorescanprovideyouwiththechemicalsandprocedurestoadjustthewaterchemistry.BesuretotellthepoolstorethatyouareusinganAquaRiteProchlorinegenera-tor.

SaturationindexThesaturationindex(Si)relatestothecalciumandalkalinityinthewaterandisanindicatorofthepoolwater"balance".YourwaterisproperlybalancediftheSiis0±.2.IftheSiisbelow-0.2,thewateriscorrosiveandplasterpoolwallswillbedissolvedintothewater.IftheSiisabove+0.2,scalingandstainingwilloccur.Usethechartbelowtodeterminethesaturationindex.

ºC ºF Ti CalcuimHardness Ci Total

Alkalinity Ai

53

60

66

76

84

94

103

12

16

19

24

29

34

39

.3

.4

.5

.6

.7

.8

.9How to use: Measure pool pH, temperature, calcium hardness,and total alkalinity. Use the chart above to determine Ti, Ci,andAi from your measurements. Insert values of pH, Ti, Ci and Aiinto the above equation. If Si equals .2 or more, scaling and staining may occur. If Si equals -.2 or less corrosion or irritationmay occur.

Si = pH + Ti + Ci + Ai - 12.1

-.2 0 .2CORROSIVE SCALING

75 75100 100125 125150 150200 200250 250300 300400 400600 600800 800

1.5 1.91.6 2.01.7 2.11.8 2.21.9 2.32.0 2.42.1 2.52.2 2.62.4 2.82.5 2.9

OK

3

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 5: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

SaltLevelUsethechartonpage5todeterminehowmuchsaltinpoundsor(Kgs)needtobeaddedtoreachtherecommendedlevels.Beawarethattheremayalreadybesaltinyourpoolfromprolongeduseofchlorine.Testyourpool,thenaddthecorrectamount.Usetheequationsbelow(measurementsareinfeet/gallonsandmeters/liters)ifpoolsizeisunknown.

Theidealsaltlevelisbetween2700-3400ppm(partspermillion)with3200ppmbeingoptimal.Ifthelevelislow,determinethenumberofgallonsinthepoolandaddsaltaccordingtothechartonpage5.AlowsaltlevelwillreducetheefficiencyoftheAquaRiteProandresultinlowchlorinepro-duction.AhighsaltlevelcancausetheAquaRiteProtoshutdownandmaybegintogiveasaltytastetoyourpool(generally,thesaltwillbegintobetastedatalevelofabout3500-4000ppm).Thesaltinyourpool/spaisconstantlyrecycledandthelossofsaltthroughouttheswimmingseasonshouldbesmall.Thislossisdueprimarilytotheadditionofwaterbecauseofsplashing,backwashing,ordraining(becauseofrain).Saltisnotlostduetoevaporation. TypeofSalttoUseItisimportanttouseonlysodiumchloride(NaCl)saltthatisgreaterthan99%pure.Thisiscommonfoodqualityorwatersoftenersaltandisusuallyavailablein40-80lb.bagslabeled"CoarseSolarSalt".Itisalsoacceptabletousewaterconditioningsaltpellets,however,itwilltakelongerforthemtodissolve.Donotuserocksalt,saltwithyellowprussiateofsoda,saltwithanti-cakingadditives,oriodizedsalt.

HowtoAddorRemoveSaltFornewplasterpools,wait10-14daysbeforeaddingsalttoallowtheplastertocure.Turnthecir-culatingpumponandaddsaltdirectlyintothepool.Brushthesaltaroundtospeedupthedissolvingprocess--donotallowsalttopileuponthebottomofthepool.Runthefilterpumpfor24hourswiththesuctioncomingfromthemaindrain(usepoolvacifthereisnomaindrain)toallowthesalttoevenlydispersethroughoutthepool.Thesaltdisplaymaytake24hourstorespondtothechangeinsaltconcentration.

Theonlywaytolowerthesaltconcentrationistopartiallydrainthepoolandrefillwithfreshwater.

Foroutdoorpools,alwayscheckstabilizer(cyanuricacid),whencheckingsalt.Theselevelswillmostlikelydeclinetogether.Usethechartonpage6todeterminehowmuchstabilizermustbeaddedtoraisethelevelto40ppm.

Gallons Liters(pool size in feet) (pool size in meters)

Rectangular

Round

Oval

Diameter x Diameter x Average Depth x 5.9

Length x Width x Average Depth x 6.7

Length x Width x Average Depth x 7.5

Diameter x Diameter x Average Depth x 785

Length x Width x Average Depth x 893

Length x Width x Average Depth x 1000

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

4

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

4

Page 6: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

Gal

lons

and

(Lite

rs) o

f Poo

l/Spa

wat

er12

,000

14,0

0016

,000

18,0

0020

,000

22,0

0032

,000

24,0

0034

,000

26,0

0036

,000

28,0

0038

,000

30,0

0040

,000

Cur

rent

sal

t le

vel

(450

00)

(52,

500)

(60,

000)

(67,

500)

(75,

000)

(82,

500)

(120

,000

)(9

0,00

0)(1

27,5

00)

(97,

500)

(135

,000

)(1

05,0

00)

(142

,500

)(1

12,5

00)

(150

,000

)pp

m 032

0

(145

)37

3

(170

)42

7

(194

)48

0

(218

)(2

42)

587

85

4

(267

)(3

88)

640

90

7

(291

)(4

12)

693

96

0

(315

)(4

36)

747

(3

39)

(460

)80

0

1067

(364

)(4

84)

200

300

(1

36)

350

(1

59)

400

(1

82)

450

(2

05)

500

(2

27)

550

80

0

(250

)(3

63)

600

85

0

(273

)(3

85)

650

90

0

(295

)(4

08)

700

95

0 (3

18)

(430

)75

0

1000

(3

41)

(453

)

400

280

(1

27)

327

(1

48)

373

(1

70)

420

(1

91)

467

(2

12)

513

74

7

(233

) (3

39)

560

79

3

(255

)(3

60)

607

84

0

(276

)(3

82)

653

88

7(2

97)

(403

)70

0

933

(318

)(4

24)

600

260

(1

18)

303

(1

38)

347

(1

58)

390

(1

77)

433

(1

97)

477

69

3

(217

)(3

17)

520

73

7

(236

)(3

37)

563

78

0

(256

)(3

58)

607

82

3(2

76)

(378

)65

0

867

(297

)(3

98)

800

240

(1

09)

280

(1

27)

320

(1

45)

360

(1

64)

400

(1

82)

440

64

0

(200

)(2

91)

480

68

0

(218

)(3

10)

520

72

0

(236

)(3

28)

560

76

0(2

55)

(346

)60

0

800

(2

73)

(364

)

1000

220

(1

00)

257

(1

17)

293

(1

33)

330

(1

50)

367

(1

67)

403

58

7

(183

)(2

67)

440

62

3

(200

)(2

83)

477

66

0(2

17)

(300

)51

3

69

7(2

33)

(317

)55

0

733

(250

)(3

33)

1200

200

(9

1)23

3

(106

)26

7

(121

)30

0

(136

)33

3

(152

)36

7

533

(1

67)

(243

)40

0

567

(1

82)

(258

)43

3

600

(1

97)

(274

)46

7

63

3(2

12)

(289

)50

0

667

(227

)(3

04)

1400

180

(8

2)21

0

(95)

240

(1

09)

270

(1

23)

300

(1

36)

330

48

0 (1

50)

(218

)36

0

510

(1

64)

(232

)39

0

540

(1

77)

(246

)42

0

57

0(1

91)

(259

)45

0

600

(205

)(2

63)

1600

160

(73)

187

(8

5)21

3

(97)

240

(1

09)

267

(1

21)

293

42

7

(133

)(1

95)

320

45

3

(145

)(2

07)

347

48

0

(158

)(2

19)

373

50

7 (1

70)

(231

)40

0

533

(182

)(2

43)

1800

140

(64)

163

(74)

187

(85)

210

(9

5)23

3

(106

)25

7

373

(1

17)

(169

)28

0

397

(1

27)

(180

)30

3

420

(1

38)

(190

)32

7

44

3 (1

48)

(201

)35

0

46

7(1

59)

(211

)

2000

120

100

80

60

20

40

(55)

(45)

(36)

(27)

(9)

(18)

140

117

23

47

(64)

(53)

(11)

(21)

160

133

27

53

(73)

(61)

(12)

(24)

180

150

30

60

(82)

(68)

(14)

(27)

200

167

33

67

(91)

(76)

(15)

(30)

220

320

183

267

37

53

73

10

7

(100

)(1

45)

(83)

(121

)

(17)

(24)

(33)

(48)

240

340

200

283

40

57

80

11

3

(109

)(1

54)

(91)

(129

)

(18)

(26)

(36)

(51)

260

36

0

217

30

0

43

60

87

120

(118

)(1

63)

(98)

(137

)

(20)

(27)

(39)

(54)

280

380

233

317

47

63

93

12

7

(127

)(1

72)

(106

)(1

44)

(21)

(29)

(42)

(57)

300

400

250

333

50

67

100

133

(136

)(1

81)

(114

)(1

52)

(23)

(30)

(45)

(60)

(32)

80

(3

6)90

(41)

100

(45)

110

160

(50)

(73)

120

170

(5

5)(7

7)13

0

180

(5

9)(8

1)14

0

19

0(6

4)(8

6)15

0

20

0(6

8)(9

0)

93

(4

2)10

7

(4

8)12

0

(5

5)13

3

(6

1)14

7

21

3

(6

7)(9

8)16

0

22

7

(73)

(104

)17

3

240

(7

9)(1

10)

187

253

(85)

(117

)20

0

26

7(9

1)(1

23)

2200

3000

2800

2400

3200

Idea

lId

eal

Idea

lId

eal

Idea

lId

eal

Idea

lId

eal

Idea

lId

eal

Idea

lId

eal

Idea

lId

eal

Idea

l

2600

3400

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

POU

ND

S an

d (K

g) O

F SA

LT N

EED

ED F

OR

320

0 PP

M

3600

+D

ilute

Dilu

teD

ilute

Dilu

teD

ilute

Dilu

teD

ilute

Dilu

teD

ilute

Dilu

teD

ilute

Dilu

teD

ilute

Dilu

teD

ilute

10,0

00 8

,000

(37,

500)

213

26

7

(97)

(121

)

200

25

0

(91)

(114

)

187

23

3

(85)

(106

)

173

21

7

(79)

(98)

160

20

0

(73)

(91)

147

18

3

(67)

(83)

133

16

7

(61)

(76)

120

15

0

(55)

(68)

107

133

(48)

(61)

93

11

7

(4

2)(5

3)

80

10

0

67

83

53

67

40

50

13

17

27

33

(36)

(45)

(30)

(38)

(24)

(30)

(18)

(23)

(6)

(8)

(12)

(15)

Idea

lId

eal

Dilu

teD

ilute

(30,

000)

5

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 7: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

6

Page 8: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

ControlsKeypadButtonsRUN/STOP:TheAquaRiteProwilltogglebackandforthbetweenRUNandSTOPwitheachpushoftheRUN/STOPbutton.

RUN:WheninRUNmode,theAquaRiteProwillproducechlorineaccordingtothedesiredoutput%orORPsetting(whenAQL-CHEMisused)fortheentirefiltering/pumpingcycle.TheAquaRiteProcanonlyproducechlorinewhenRUNisselectedandthefilterpumpisrunning.

STOP: WheninSTOPmode,theAquaRiteProispreventedfromenergizingtheelectrolyticcell.Inthispositionthereisnochlorinegeneration.NOTE:ToserviceanyofthepoolequipmentortheAquaRitePro,thepowermustbeturnedoffatthecircuitbreaker. SUPER CHLORINATE: (ifoptionalAQL-CHEMsensingisNOTused)Whenyouhaveanabnormallyhighbatherload,alargeamountofrain,acloudywatercondition,oranyotherconditionwhichneedsalargeamountofpurificationtobeintroduced,SUPERCHLORINATEshouldbeselected.Thiselectronically“superchlorinates”(shocks)thewaterforauserselectableperiodof1-96hours(filterpumpmustbeonduringthistime)oruntilthepowerhasbeenturnedoff,whichevercomesfirst.TheAquaRiteProwillautomaticallyrevertbacktothepreviousdesiredoutput%set-tingattheendofthesuperchlorinateperiod.

INFO: PushtheINFObuttontoentertheInformationMenu(seeInformationMenu).

SETTINGS:PushtheSETTINGSbuttontoentertheSettingsMenu(seeSettingsMenu).

CURSORS (+, -, <, >): Usethesebuttonstoscrollthroughsubmenus,makeselectionsandadjustvalues.

IndicatorLED'sRUN/STOP: Whenilluminated,theAquaRiteProisinautomaticmodeandwillproducechlorinebasedonthedesiredoutput%orORPsetting(whenAQL-CHEMisused).WhentheLEDisoff,theAquaRiteProhasbeenmanuallyturnedoff.ItwillnotproducechlorineuntilRUNhasbeenselected.

SUPER CHLORINATE: Whenilluminated,theSuperChlorinatefeatureisactive.

CHECK SYSTEM:WhenCheckSystemisilluminated,anerrorhasoccurredthatrequiresatten-tion.RefertotheTroubleshootingsectionofthismanualforpossibleerrorsandsolutions.

7

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 9: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

InformationMenuTheInformationMenudisplaysvaluablesystemandpoolinformation.TheAquaRiteProwilldefaulttodisplayingaportionoftheInformationMenuwhennobuttonshavebeenpushedfor2minutes.Theunitwillautomaticallyscrollthroughseveralstatusdisplays.ToaccessalloftheInformationMenuitems,pushtheINFObuttononthefrontpanel.Advancethroughthevariousmenuitemsusingthe"<"or">"buttons.AlistoftheInformationMenuitemsisshownbelow.

TheAquaRiteProdesiredoutput%isshownhere.IfSuperChlorinateisactive,thedisplaywillshowthetimeremaininguntiltheAquaRiteProwillreturntothedesiredoutput%.ThismenuisdisabledifanAQL-CHEMisusedandORPAutoSensingisenabled(seeAQL-CHEMmanual).

Thisdisplaywillbeshownonlyifchemicalsensingisenabled.ThisdisplayshowsbothpHandORPlevels/statuswhenchemistrysensingisenabledviatheChemistryCon-figurationWizard(requirestheuseofAQL-CHEMSensingKit).TheAquaRiteProwillrefertotheselevelstodeterminehowmuchchlorinetogenerate(ORP)andhowmuchCO

2oracidtodispense(pH).RefertotheAQL-CHEMmanualforspecificinformation

abouttheselevelsaswellastherecommendedranges.

+/-23.45Visthevoltageappliedtothechlorinatorcell+/-6.75Aisthecurrent(amps)throughthecell84ºFisthewatertemperatureatthecell3200PPMisthe“instant”saltlevelatthistime

Forthechlorinatortobeoperating,severalconditionsmustexist:thefilterpumpmustberunning,theflowswitchmustbedetectingflow,thechlorinatorsettingmustbesetgreaterthan0%,thewatertemperatureatthecellmustbebetween50ºFand140ºF,andthesaltlevelmustbewithintheoperatingrange.Ifanyoftheseconditionsarenotmet,thechlorinatordiagnosticdisplaywilltellyouthereason.It’spossibletohavemorethanonereason,inwhichcaseafteryourectifywhatwasdisplayedthefirsttime,aseconddisplaywillappear.

Ifthecurrent(amps)displayis0.00A,thenthechlorinatorisoperatingnormallybutisintheoffpartofitsnormaloperatingcycle.Simplypresseitherthe“+”or“-“keytostartanewcycle.

TheAquaRiteProperiodicallyreversesthepolarityofthevoltageappliedtothecellinordertoautomaticallycleanoffanycalciumdepositsthatmayhavebuiltuponthecell.Itisimportantthatyoucheckthechlorinatoroperationinbothpolarities.Todothis,presseitherthe“+”or“-“buttonsandthechlorinatorwillturnoff,waitfor15secondsandthenturnonintheoppositepolarity.

Chlorinator50%

No functionMove to previous/next menu item

Super Chlorinate22:15 remaining

No functionMove to previous/next menu item

if ORP Auto Sensing is not used

pH 7.5 (On)ORP 700 mV (On)

No functionMove to previous/next menu item

if AQL-CHEM is used

Set Day and TimeWednesday 10:37P Move to previous/next menu item+23.45 +6.75A84°F 3200PPM

Press to switch chlorinator operation to opposite polarity (15 second delay)

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

8

Page 10: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

Thisistheaverage"SaltLevel"inthepool.Thisvalueiscalculatedovertimeandminimizestheeffectsofspikesordipsthatmaynaturallyoccur.

The“InstantSalt”iscalculatedbasedonthevoltage,current(amps),andwatertemperatureatthecellatthatinstant.Thereareanumberofreasonswhyinstantandaveragesaltreadingsmaydiffer.Someoftheseincludesalthavingjustbeenaddedtothepoolandnotyetthoroughlymixed,calciumbuilduponthecell,andcellaging.

Pressthe"+"buttontoentertheinstantsaltvalueintotheaveragesaltlevel.Theaveragesaltlevelwillusethisnewvalueforitscalculations.

Thecurrentstatusoftheflowswitchisdisplayed.Thereisashortdelaywhentransi-tioningfromflowtono-flowandalongerdelayonthetransitionfromno-flowtoflow.Thedelaytimeisdisplayed.

Availabledisplaysdependonconfiguration.Thesedisplaysshowthesoftwarerevisionsofvariouscomponents.

Foroptimumoperation,youwillneedtoinspecttheAquaRiteProchlorinatorcellapproximatelyevery3monthsandcleanthecellifnecessary.TheAquaRiteProwillautomaticallyremindyouanddisplay“InspectCell,hold+toreset”aspartoftherotatingInformationMenu.Cleanthecellandthenpressthe“+”buttonduringthe“InspectCell”displaytoresetthetimer.

Salt Level3200 PPM

No functionMove to previous/next menu item

Instant Salt3200 PPM (+=save) Move to previous/next menu item

Press to load the “Instant Salt” into the averaged salt display

Flow SwitchFlow

No functionMove to previous/next menu item

Main SoftwareRevision 1.10

Display SoftwareRevision 0.18

No function

No function

Move to previous/next menu item

Move to previous/next menu item

Chemistry SenseSoftware r1.28

No functionMove to previous/next menu item

Inspect Cellhold + to reset

Press to resetMove to previous/next menu item

9

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 11: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

RefertotheTroubleshootingsectionforinformationabouterrorconditionsandpossiblecauses.

SettingsMenuTheSettingsMenuisusedtoconfiguretheAquaRiteProandadjustvarioussettings.AccessthismenubypushingtheSettingsMenubutton.Refertotheinformationbelowwhensettingsystemoperatingparameters.

Body of Water TypeSelectPoolorSpa."Pool"shouldbeselectedforbodiesofwaterover1000gallons.TheAquaRitePro will adjustitsoperationaccordingtothisselection. DisplayAllowsforthedisplayofsalt(default)ormineralvalues.

Cell Type SelectionSelectionsare:T-CELL-3,T-CELL-5,T-CELL-9andT-CELL-15(default).TheAQR15-PROandAQR15-PRO-SDincludeaT-CELL-15cell.Notethattheunitwillnotfunctionproperlyifthewrongcellisselected.

"T-CELL-3"=T-CELL-3,GLX-CELL-3-W"T-CELL-5"=GLX-CELL-5,GLX-CELL-5-W"T-CELL-9"=T-CELL-9,GLX-CELL-9-W"T-CELL-15"=T-CELL-15,GLX-CELL-15-W

RequiresuseoftheoptionalAQL-CHEMSensingKit.FollowingthestepsoftheChemis-tryConfig.WizardwillsetuptheAQL-CHEMtosenseORPandpHlevels.TheAquaRiteProwillgeneratethecorrectamountofchlorinetoproperlysanitizethepoolbasedontheAQL-CHEMsensingfunction.RefertotheAQL-CHEMmanualformoredetailedinformation.

Check SystemLow Salt

Function depends on displayed menu itemMove to next Check System condition orprevious/next menu item

Cell TypeT-CELL-15

Toggle between available cell typesMove to previous/next menu item

Move to next menu itemChlorinator

Enabled

DisplaySalt

Chlor. Config.+ to view/change

Toggle between Salt (default) and Minerals

Toggle between Pool and Spa

Move to next menu item

Move to previous/next menu itemPush to access Chlorinator option

Cell TypeT-CELL-15

Body of Water TypePools

DisplaySalt

Chlor. Config.+ to view/change

Chemistry Config.Wizard + to enter

Sensing SystemEnabled

Push to access Chemistry Config. Wizard

Toggle between Enabled and Disabled (default)

Move to previous/next menu item

Move to next menu item

if AQL-CHEM is used

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

10

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 12: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

Thedesiredoutput%isusedtocontroltheamountofchlorinetheAquaRiteProgen-erates.Raisethissettingtoincreasechlorinelevelandlowerittodecreasechlorinelevel.IfanAQL-CHEMisbeingusedandORPAutoSensingisenabled(seeAQL-CHEMmanual),theAquaRiteProwilloverridethedesiredchlorinatoroutput%settingandgeneratechlorinebasedonthepool'sORPlevel.

UsetheSuperChlorinatefeaturewhenthereisanunusuallyhighbatherload,alargeamountofrain,acloudywatercondition,oranyotherconditionthatrequiresalargeamountofchlorinetobeintroducedtothepool.NotethatthefilterpumpmustberunningfortheentiretimeduringtheSuperChlorinateperiod.Settheactualtimebasedonthesizeofthepool;largerpoolsrequiremorehours,smallerpoolsrequireless.

UsethisWizardtocalibratetheoptionalAQL-CHEM’spHprobe.ThisrequiresamanualpHtestofthepoolwaterusingadependableredphenoltestkit(seeAQL-CHEMmanual).

UsethisWizardtocleantheoptionalAQL-CHEM’sORPandpHprobes.Theprobesmustbecleanandfreefromoil,chemicaldepositsandcontaminationtofunc-tionproperly.Slowresponse,increasedneedtocalibrate,andinconsistentreadingsareindicationsthattheprobesneedtobecleaned(seeAQL-CHEMmanual).

TheAquaRiteProcandisplaytemperatureandunitsinMetric(ºCandg/L)orEnglish(ºFandPPM).Makethedesiredselectionhere.

Chlorinator50%

Adjust the desired output % for the poolMove to previous/next menu item

if ORP Auto Sensing is not used

Super Chlorinate22 hours

Adjust Super Chlorinate period (1-96 hours)Move to previous/next menu item

if ORP Auto Sensing is not used

if AQL-CHEM is usedClean Probe Wizard

+ to enterPush to access Clean Probe WizardMove to previous/next menu item

pH CalibrationWizard + to enter

Push to access pH Calibration WizardMove to previous/next menu item

if AQL-CHEM is used

UnitsMetric Move to previous/next menu item

Toggle between Metric and English

11

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 13: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

Thisfunctioncontrolsthebacklightonthedisplay.Selectbetween"AlwaysOn"and"Onfor60seconds".If“Onfor60seconds”optionisselected,thentheback-lightwillautomaticallyturnoff60secondsafterthelastkeyispressedandwillstayoffuntilnexttimeakeyispressed.

When“Enabled”,thekeypadwillbeepeverytimeakeyispressed.Ifthisaudibleindicationisnotdesired,select“Disabled”.

Usethisfunctiontoeraseallprevioussystemconfigurationandresetallconfigura-tionparametersbacktothefactorydefaultvalues.ThisfunctionisNOTreversible--becareful

OperationAssumingthatthewaterchemicallevelsareintherecommendedrange,therearethreefac-torsthatyoucancontrolwhichdirectlycontributetotheamountofchlorinetheAquaRiteProwillgenerate:

1. filterruntimeeachday(hours)2. thedesiredoutput%settingorORPsetting(whenusingAQL-CHEM)3. theamountofsaltinthepool Thefilterpumptimershouldbesetsothatentirevolumeofpoolwaterpassesthroughthefiltereachday.Forpoolswithhighchlorinedemand,thetimermayhavetobesetlongertogenerateenoughchlorine.

IfAQL-CHEMsensingisNOTused:Tofindtheoptimumdesiredoutput%setting,startatapproximately50%.Testthechlorineleveleveryfewdaysandadjustthesettingupordownaccordingly.Itusuallytakes2-3adjustmentstofindtheidealsettingforyourpool/spaandafterthat,itshouldonlytakeminor,infrequentadjustments.Becausethechlorinedemandofthepoolincreaseswithtemperature,mostpeoplefindtheyhavetoadjustthedesiredoutputupatthepeakofthesummeranddownduringthecolderperiods.

NOTE:Aftertheidealsettinghasbeenfound,youmayneedtoraisethesettingwhenthepoolwatertemperatureincreasessignificantly,whenthereishigherthannormalbatherloadorwhenyourchlorinatorcellages.Youmayneedtolowerthesettingwhenthepoolwatertemperaturedecreasessignificantlyortherearelongperiodsofinactivity.

Display LightOn for 60 sec

Toggle between Always On and On for 60 sec.Move to previous/next menu item

BeeperEnabled

Toggle between Enabled (default) and Disabled BeeperMove to previous/next menu item

Reset Config. toDefault Press +

Are you sure?+ to proceed

Config. resetConfirmed

Initiate reset of all configuration parameters

Reset all configuration parameters

Move to previous/next menu item (config. not reset)

Move to previous/next menu item (config. not reset)

Move to previous/next settings menu item

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

12

Page 14: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

TheAquaRiteProautomaticallystopsgeneratingwhenthepoolwatertemperaturesdropsbelow50ºF.Thisisusuallynotaproblembecausebacteriaandalgaestopgrowingatthistemperature.YoucanoverridethislowtemperaturecutoffbyusingtheSuperChlorinatefunctionforaday.Preventoverchlorinationduringcoldweather:Checkchlorinelevelsperiodically.Mostpoolsrequirelesschlorineduringcoldweatherandthedesiredoutput%settingshouldbeloweredaccordingly. MaintainingtheAquaRiteProSystemTomaintainmaximumperformance,itisrecommendedthatyouopenandvisuallyinspectthecellevery3monthsoraftercleaningyourfilter.TheAquaRiteProwillremindyoutodothisbydisplay-ingthemessage“Inspect/CleanCell”afterapproximately500hoursofoperation.

TheAquaRiteProelectrolyticcellhasaselfcleaningfeatureincorporatedintotheelectroniccon-trol’slogic.Inmostcasesthisselfcleaningactionwillkeepthecellworkingatoptimumefficiency.Inareaswherewaterishard(highmineralcontent)andinpoolswherethewaterchemistryhasbeenallowedtoget"outofbalance",thecellmayrequireperiodiccleaning.

ServicingandCleaningtheAquaRiteProCellTurnoffpowertotheAquaRiteProbeforeremovingtheelectrolyticcell.Onceremoved,lookinsidethecellandinspectforscaleformation(lightcoloredcrustyorflakydeposits)ontheplatesandforanydebriswhichhaspassedthroughthefilterandcaughtontheplates.Ifnodepositsarevisible,reinstall.Ifdepositsareseen,useahighpressuregardenhoseandtrytoflushthescaleoff.Ifthisisnotsuccessful,useaplasticorwoodtool(donotusemetalasthiswillscratchthecoatingofftheplates)andscrapedepositsoffofplates.Notethatabuilduponthecellindicatesthatthereisanunusuallyhighcalciumlevelinthepool(oldpoolwaterisusuallythecause).Ifthisisnotcorrected,youmaytohavetoperiodicallycleanthecell.Thesimplestwaytoavoidthisistobringthepoolchemistrytotherecommendedlevelsasspecified.

Mild Acid Washing:Useonlyinseverecaseswhereflushingandscrapingwillnotremovethemajorityofdeposits.Toacidwash,turnoffpowertoAquaRitePro.Removecellfrompiping.Inacleanplasticcontainer,mixa4:1solutionofwatertomuriaticacid(onegallonofwatertoonequartofmuriaticacid).ALWAYSADDACIDTOWATER-NEVERADDWATERTOACID.Besuretowearrubberglovesandappropriateeyeprotection.

Thelevelofthesolutioninthecontainershouldjustreachthetopofthecellsothatthewirehar-nesscompartmentisNOTsubmerged.Itmaybehelpfultocoilthewiringbeforeimmersingthecell.Thecellshouldsoakforafewminutesandthenrinsewithahighpressuregardenhose.Ifanydepositsarestillvisible,repeatsoakingandrinsing.Replacecellandinspectagainperiodically.

WinterizingTheAquaRiteProelectrolyticcellandflowdetectionswitchwillbedamagedbyfreezingwaterjustasyourpoolplumbingwould.Inareasofthecountrywhichexperiencesevereorextendedperiodsoffreezingtemperatures,besuretodrainallwaterfromthepump,filter,andsupplyandreturnlinesbeforeanyfreezingconditionsoccur.Theelectroniccontroliscapableofwithstandinganywinterweatherandshouldnotberemoved.

SpringStart-upDONOTturntheAquaRiteProon,untilthepoolwaterchemistryhasbeenbroughttotheproperlevels.Thisinformationcanbefoundonpage3.

13

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 15: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

InstallationInstallationmustbeperformedinaccordancewithLocalandNECcodes.

PreparingPool/SpaWaterRefertopage3forrecommendedchemicallevels.Thepool'schemistrymustbebalancedBE-FOREactivatingtheAquaRitePro.NOTE:Ifthepooldoesnothavenewwater,add1quart(1liter)ofmetalremoverand1quart(1liter)ofnon-copperbasedalgaecidetothepool,permanufac-turer'sinstructions.Thisensuresaquick,troublefreetransfertotheAquaRiteProsystem.

MountingtheAquaRiteProControlTheAquaRiteProiscontainedinaraintightenclosurethatissuitableforoutdoormounting.Thecontrolmustbemountedaminimumof5ft.(1.5meters)horizontaldistance(ormore,iflocalcodesrequire)fromthepool/spa.

Thecontrolisdesignedtomounthorizontallyonaflatsurfacewiththeknockoutsfacingdown-ward.Becausetheenclosurealsoactsasaheatsink(dispersesheatfrominsidethebox),itisimportantnottoblockthefoursidesofthecontrol.DonotmountAquaRiteProinsideapanelortightenclosedarea.

FROMPOOL

120/240 VACPOWER

TOPOOLFROM

SPA

TOSPA

Aqua Rite Pro

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

14

Page 16: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

IfanAQL-CHEMkitwillbeused,takeintoconsiderationthespacenecessaryformountingtheunitaswellasrunningtheplumbinglinesfromtheAQL-CHEM'sprobecelltothepoolplumbing.RefertotheAQL-CHEMmanualforspecificmountinginstructions.

PlumbingEnsurethattheAquaRiteProinstallationdoesnotconstituteacrossconnectionwiththelocalpotablewatersupply.Consultlocalplumbingcodes.

TheAquaRiteProispackagedwithaTurboCell,flowswitchandcellunions.

Theflowswitchandcellshouldbeplumbedinthereturnlinetothepool/spa.Thepreferredinstallationisafter(downstream)allthepoolequipment(filter,heater,solar,etc.).Theelectrolyticcellandflowswitchteefittingaredesignedtobeplumbedinto2"(51mm)PVCpipe.Adapters(notincluded)canbeusedforsystemswith1½"(38mm)plumbing.

Forproperplumbing,refertotheoverviewdiagramonpage14.Alternateconfigurations#1showstheflowswitchcanalsobeinfrontofthecell.Configurations#2and#3allowforchlorina-tionofboththepoolandspaduringspaspilloveroperation,butpreventoverchlorinationofthespaduring"spaonly"operation.Neveruseconfiguration#4.

2

3 4

1

12”

12”min

min

Flow Switchbefore Cell

Flow Switchafter Cell

15

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 17: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

Flow Switch: IMPORTANT:Theremustbeatleasta12"(25cm)straightpiperunbefore(upstream)theflowswitch.Iftheswitchisplumbedafterthecell,thecellcanbycountedasthe12"(25cm)ofstraightpipe.Toensureproperoperation,verifythatthearrowontheflowswitch(locatedontopofgrayhex)pointsinthedirectionofwaterflow.

Electrolytic Cell: Installusingtheunionsprovided.TightenunionsBYHANDforawatertightseal.Forpool/spacombinationsystemswithspillover,useconfigurations#2or#3abovetoallowchlorinationofboththepoolandspaduringspilloverbutpreventingoverchlorinationwhenoperatingthespaonly.

WiringPowermustbeshutoffatthecircuitbreakerbeforeperforminganywiring.BesuretofollowLocalandNECelectricalcodes.Toprovidesafeoperation,theAquaRitePromustbeproperlygroundedandbonded.

InputPower:WiretheAquaRitePrototheLOADSIDEofthefilterpumptimer.ItisveryimportantthattheAquaRiteProispoweredonlywhenthepumpisrunning.

RefertothewiringlabelontheAquaRiteProaswellasthediagrambelowtodeterminecorrectwiringconnections.TheAquaRiteProisshippedfromthefactorywiththeconfigurationjumpersin240VACposition.Ifusing120VAC,movethejumpersasshownbelow.IMPORTANT:Ifadispensingdevicewillbeused(page19),itmustbepoweredbythesameinputvoltageastheAquaRitePro.

Besuretoconnectthegroundwiretothegreengroundscrewterminallocatedonthebottomoftheenclosure.

SUBPANEL

TIMECLOCKAQUA

RITE ProAQUA

RITE Pro

PCB

GND

PCB

BONDINGLUG

BONDINGLOOP

PUMP

LINELOAD

GROUND

IMPORTANT:MOVE JUMPERS

TO POSITIONS SHOWN

TYPICAL 240 VAC WIRING120 VAC

Note: Wire the pump directly to the timeclock--do not use the Aqua Rite Pro as a junction box.

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

16

Page 18: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

BondingAlugusedforbondingisattachedtothebottomoftheAquaRiteProenclosure(twolugsarepro-videdforCanadianmodels).TheAquaRitePromustbebondedwithan8AWGcopperwire(6AWGCanada)tothepoolbondingsystem.Refertothediagrambelow.

ElectrolyticCellandFlowSwitchTheelectrolyticcellandflowswitchcablesareterminatedwithconnectorswhichplugintotheAquaRiteProforeasyattachmentandremoval.ThedooroftheAquaRitePromustbeopenandthefrontpanelremovedtoaccessthecellcableandflowswitchconnectors.Routetheflowswitchcablethroughoneoftheknockouts.Acutoutintheenclosureisprovidedforthecellcable.Thediagrambelowshowsthelocationoftheseconnections.

Bonding lug to poolbonding systemSecond bonding lug for

Canadian models only

Cutout forcell cable

Bottom of Aqua Rite Pro Enclosure

Cell Connector

Flow SwitchConnector

17

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 19: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

Connector forAQL-CHEM

OptionalAQL-CHEMChemistryKit(includedwithAQR15-PRO-SD)PlugtheconnectorfromtheAQL-CHEMintothedesignatedconnectorontheAquaRiteProPCBasshownbelow.Fordetailedinstallationandoperationinformation,refertotheAQL-CHEMinstructions.

HaywardAquaRiteChlorinatorTheAquaRiteProcancontroloneormoreHaywardAquaRitechlorinatorswhenadditionalsanitizingcapacityisrequired.A4wireconnectionisusedtocommunicatetotheAquaRite(s)andcanbewiredupto500'apart.Anyoutdoorrated4conductorcablecanbeused.Re-fertothewiringdiagrambelowforproperwiringconnectiontotheAquaRite.NOTE:Theremustbeonly1"primary"unit.AllotherAquaRiteunitsmustbeconfiguredas"secondary".

TheAquaRite(s)powerinputmustbewiredtotheLOADSIDEofthefilterpumptimer(thesameastheAquaRitePro).

Aqua RitePro Aqua Rite

(Primary)Aqua Rite

(Secondary)

AdditionalAqua Rite(s)(if required)

Jumper RemovedFor Secondary(s)Jumper Installed

For Primary(Factory Default)

1234 GREEN

YELLOWBLACKRED

NOTE: Primary/Secondary jumper is located underneath small circuit board.

1 42 3

3 24 1GRN

GRNBLK

BLKYELYEL

RED

RED

Aqua RitePro Aqua Rite

green

yellow

black

red

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

18

Page 20: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

OptionalpHDispenseWiringRequirestheuseofaHaywardAQL-CHEMsensingdeviceandanAQL-CHEM2,AQL-CHEM2-240orotherpHdispensingdevicerequiring120VACor240VACon/offcontrol.AscrewterminalblocklocatedontheenclosuresurfacebelowthetransformerisprovidedforconnectiontoanAQL-CHEM2,AQL-CHEM2-240orotherpHrelateddispensingdevice(peristalticpumps,solenoidvalves,etc.).AfterproperlyinstallingandconfiguringtheAQL-CHEMandthepHdispensingdevice,theAquaRiteProwillturnonthedispensingdevicewhenpHcorrectionisrequired.

IMPORTANT:ThedispensingdevicemustbepoweredbythesamevoltageusedtopowertheAquaRitePro.ConfiguretheoutputvoltagetothepHdevicebymovingthewiringconnectionsonthemainboardasshownbelow.

Example:IfanAQL-CHEM2-240(240VAC)willbeused,theAquaRitePromustbepoweredby240VAC.Connectthe240VACpigtailsuppliedwiththeAQL-CHEMtotheAquaRitePro’stermi-nalblockasshowninthediagram.TheAQL-CHEM2-240willthenplugintothepigtail’s240VACreceptacle.RefertotheAQL-CHEMmanualformoredetailedinformation.

240 VAC

120 VACN

L2

L1

L1

EP1

EP2

Ground

For 120VAC operationposition connectors as shown

Groundto AQL-CHEM2 Pigtail or

120VAC pH Dispensing Device

to AQL-CHEM2-240 Pigtail or240VAC pH Dispensing Device

WHITE

WHITE

BLACK

BLACK

EP1

EP3

240VAC pH Dispensing Device(Factory Default)

120VAC pH Dispensing Device

19

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 21: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

TroubleshootingThe“CHECKSYSTEM”LEDwillalertyouwhentheAquaRiteProdetectsanyofthefollowingcondi-tionsthatareabnormalandrequireattentionforoptimaloperationofyourpool.Press“<“or“>”toviewalloftheexisting“CheckSystem”conditions.

• Inspect Cell --Foroptimumoperation,youwillneedtoinspecttheAquaRiteProchlorinatorcellapproximatelyevery3monthsandcleanthecellifnecessary.TheAquaRiteProwillautomati-callyremindyouwhenitistimeanddisplay“InspectCell,+toreset”aspartoftherotatingDefaultMenu.Cleanthecell(page13)andthenpressthe“+”buttonduringthe“InspectCell”displaytoresetthetimer.

• Low Salt/Minerals or Very Low Salt/Minerals --WhenthesaltistoolowtheAquaRiteProwillgeneratelesschlorineandthelifeofthecellisdegraded.Checkthecellandcleanifneces-sarybeforeaddingsalt.

• High Salt/Amps/Minerals --TheAquaRiteProwillstopgeneratingchlorineunder certainhighsaltconditionsinordertoprotecttheinternalelectronicsfromdamage. Theonlywaytolowerthesaltlevelistopartiallydrainthepoolandaddfreshwater.

• Chlorinator Cell Sensor--Thecellsensoriseitheranopenorshortcircuit.

• Low Volts --Ifthechlorinatorcellvoltageistoolow.

• No Cell Power --Ifnochlorinatorcellpowerisdetectedontheprintedcircuitboard.

• Check Flow Switch --Iftheflowswitchinputisinvalid.

• Cell Power Error --Ifachlorinatorcellpowererrorisdetectedontheprintedcircuitboard.

• Cell Missing --Ifthechlorinatorisenabledbutnocellisdetected.

• CSM Comm Error: --IfChemistrySensingisenabledandtheChemistrySenseModule(CSM)isnotresponding.

• pH Probe Error --IftheCSMindicatesthatthereisaproblemwiththepHprobe.

• pH Low-CheckFeeder--IfapHlevelof6.9orlessisdetected,checkthefeederforproperoperation

• pH High-CheckFeeder--IfapHlevelof8.1orhigherisdetected,checkthechemicalsupplyandthefeederforproperoperation

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

20

Page 22: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

• pH Timeout-CheckFeeder--Iftheunithasbeendispensingformorethantheselectedtimeoutwithoutreachingthedesiredlevel.Checkthechemicalsupplyandthefeeder.IfbothareOK,thetimeoutmayneedtobeincreased.Pressthe“+”buttontoresetthealarmandresumedispensing.

• pH Calibration Error --WhenusingthepHCalibrationWizardandtheenteredtestresultwasdifferentfromthemeasuredpHlevelby±1.0ormore.ThepHprobemayneedtobecleanedorreplaced.

• ORP Probe Error --IftheCSMindicatesthatthereisaproblemwiththeORPprobe.

• ORP Low -CheckChlor--IfanORPlevelof350mVorlessisdetected.Checkthechlorina-torforproperoperation.

• ORP High -CheckChlor--IfanORPlevelof950mVorhigherisdetected.Checkthechlorinatorforproperoperation.

• ORP High -ChlorOff--IfanORPlevelof950mVorhigherisdetectedandthechlorinefeedmodeisORPAutoSensing,thechlorinatorhasbeenturnedoff.Checkthechlorinatorforproperoperation.

• ORP Timeout -ChlorOff--Iftheunithasbeenchlorinatingformorethantheselectedsani-tizertimeoutwithoutreachingthedesiredlevel,thechlorinatorhasbeenturnedoff.Pressthe“+”buttontoresetthealarmandresumechlorination.

• Ambient Sensor--Iftheinternal(ambient)sensoriseitheropenorshortcircuit.

21

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 23: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

LIMITEDWARRANTY(effective03/01/12)HaywardwarrantsitsProLogic,OnCommandandE-CommandpoolautomationproductsaswellasitsAquaRite,AquaRitePro,AquaPlusandSwimPurechlorinationproductstobefreeofdefectsinmaterialsandworkmanship,undernormaluseandservice,foraperiodofthree(3)years.Haywardalsowarrants itsAquaTrolchlorinationproductstobefreeofdefects inmaterialsandworkmanship,undernormaluseandserviceforaperiodofone(1)year.Thesewarran-tiesareapplicablefromtheinitialdateofpurchaseonprivateresidentialswimmingpoolsintheUSandCanada. InstallationsofproductforuseoncommercialpoolsintheUSandCanadaiscoveredforaperiodofone(1)yearfordefectsinmaterialsandworkmanship.Haywardwarrantsallaccessoriesandreplacementpartsfortheabove-identifiedpoolautomationandchlorinationproductsforaperiodofone(1)year.Accessoriesalsoincluderemotes,actuators,basestations,temperaturesensors,flowswitchesandchemistryprobes.Eachofthesewarrantiesisnottransferableandappliesonlytotheoriginalowner.

Haywardshallnotberesponsibleforcartage,removal,repairorinstallationlabororanyothersuchcostsincurredinobtainingwarrantyreplacementsorrepair.

Proof of purchase is required forwarranty service. Ifwrittenproof of purchase is not provided, themanufacturingdatecodewillbethesoledeterminantofthedateofinstallationoftheproduct.Toobtainwarrantyserviceorrepair,pleasecontacttheplaceofpurchaseorthenearestHaywardauthorizedwar-rantyservicecenter.FormoreinformationonauthorizedservicecenterspleasecontacttheHaywardTechnicalServiceSupportCenter(61WhitecapRoad,NorthKingstownRI,02852)orvisittheHaywardwebsiteatwww.hayward.com.

WARRANTYEXCLUSIONS:

1.Materialsuppliedorworkmanshipperformedbyothersinprocessofinstallation.

2.Damageresultingfromimproperinstallationincludinginstallationonpoolslargerthantheproductrating.

3.Problemsresultingfromfailuretoinstall,operateormaintaintheproduct(s)inaccordancewiththerecommendationscontainedintheownersmanual(s).

4.Problemsresultingfromfailuretomaintainpoolwaterchemistryinaccordancewiththerecommenda-tionsintheownersmanual(s).

5.Problemsresultingfromtampering,accident,abuse,negligence,unauthorizedrepairsoralternations,fire,flood,lightning,freezing,externalwater,degradationofnaturalstoneusedinorimmediatelyadjacenttoapoolorspa,waroractsofGod.

6. Use of a non-genuineHayward replacement salt chlorination cell on anyHayward automation orchlorinationproductwillvoidthewarrantyforthatproduct.

TheexpresslimitedwarrantyaboveconstitutestheentirewarrantyofHaywardPoolProductswithrespecttoitsproductsandisinlieuofallotherwarrantiesexpressedorimplied,includingwarrantiesofmerchant-abilityorfitnessforaparticularpurpose.InnoeventshallHaywardPoolproductsberesponsibleforanyconsequential,specialorincidentaldamagesofanynature.Somestatesdonotallowalimitationonhowlonganimpliedwarrantylasts,ortheexclusionofincidentalorconsequentialdamages,sotheabovelimitationmaynotapplytoyou.Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrights,whichvaryfromstatetostate.

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

22

Page 24: Aqua Rite Pro · 2017. 11. 7. · AquaRite Pro senses the pool's ORP and pH levels and automatically generates the correct amount of chlorine to keep your pool properly sanitized

Free Chlorine 1.0 - 3.0 ppm pH 7.2 - 7.8

Raise desired output % toincrease, lower desired output %to decrease -OR- increase ordecrease pump filtration time.

Too low - add soda ash.Too high - add muriatic acid

Alkalinity 80 - 120 ppm

Salt 2700 - 3400 ppm Add salt as required to increase.

Add baking soda to increase.

Stabilizer 30 - 50 ppm Add cyanuric acid to increase.

Calcium 200 - 400 ppm Add calcium to increase. Electrolytic Cell inspect & clean Refer to section in manual.

TEST IDEAL RANGE ADJUSTMENT REQUIRED

Drain and add water to decrease.

Add acid as required to decrease.

WE

EK

LYM

ON

THLY

QU

AR

TTE

RLY

ELECTROLYTIC CHLORINE GENERATORBASIC POOL MAINTENANCE REQUIREMENTS

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Forfurtherinformationorconsumertechnicalsupport,visitourwebsiteat

www.hayward.com

HaywardisaregisteredtrademarkandAquaRite,ProLogicandAquaLogicaretrademarksofHaywardIndustries,Inc.©2013HaywardIndustries,Inc.

AllothertrademarksnotownedbyHaywardarethepropertyoftheirrespectiveowners.Haywardisnotinanywayaffiliatedwithorendorsedbythosethirdparties.

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS