Lower nappe aeration in smooth channels: experimental data
and numerical simulation
EUDES J. ARANTES1, RODRIGO M. PORTO2, JOHN S. GULLIVER3,
ALBERTO C.M. LIMA4 and HARRY E. SCHULZ2,5
1UTFPR, Campus Campo Mouro, Caixa Postal 271, 87301-005 Campo Mouro, PR, Brasil2Departamento de Hidrulica e Saneamento/EESC/USP,
Av. Trabalhador So-carlense, 400, 13566-590 So Carlos, SP, Brasil3Department o Civil Engineering, University o Minnesota, 2 Third Avenue S.E, 55455 Minneapolis, MN, USA
4Universidade da Amaznia, Av. Alcindo Cancela, 287, Umarizal, 66060-000 Belm, PA, Brasil5Ncleo de Engenharia Trmica e Fluidos/EESC/USP,
Av. Trabalhador So-carlense, 400, 13566-590 So Carlos, SP, Brasil
Manuscript received on September 14, 2008; accepted or publication on September 30, 2009
ABSTRACT
Bed aerators designed to increase air void ratio are used to prevent cavitation and related damages in
spillways. Air entrained in spillway discharges also increases the dissolved oxygen concentration o the
water, which can be important or the downstream shery. This study considers results rom a systematic
series o measurements along the jet ormed by a bed aerator, involving concentration proles, pressure
proles, velocity elds and corresponding air discharges. The experimental results are, then, compared,
with results o computational fuid dynamics (CFD) simulations with the aim o predicting the air discharge
numerically. Comparisons with jet lengths and the air entrainment coecients rom the literature are also
made. It is shown that numerical predictive tools urnish air discharges comparable to measured values.
However, i more detailed predictions are desired, verication experiments are still necessary.
Key words: spillway aerators, air entrainment, air-water fows, multiphase fows.
INTRODUCTION
Bottom aerators are a technique used to prevent cavitation erosion on spillways and to enhance the oxygencontent o the water. Air vented through the bottom aerators is entrained into the fowing water, increasing
the compressibility o the air-water mixture and lowering the velocity o pressure waves. When implosion
o cavitation bubbles occurs, the higher compressibility o the surrounding fuid dampens the impact o the
pressure waves. Additionally, the bubbles increase the contact area between air and water, improving the
oxygen dissolution into the water and the DO content downstream o the spillway.
Correspondence to: Pro. Harry Edmar SchulzE-mails: [email protected]; [email protected]; [email protected]
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
2/17
522 EUDES J. ARANTES et al.
Experimental investigations on spillway air entrainment by bottom aerators have resulted in empirical
design equations. Schwarz and Nutt (1963) presented a theoretical equation or the jet length ormed ater
the ramp. Pan et al. (1980) and Pinto et al. (1982) related the air discharge to geometrical parameters o
the jet. Additionally, Tan (1984) and Rutschmann and Hager (1990) explained the dependence o the air
discharge on the jet length. The jet length predictions obtained by Tan (1984) are close to those o Schwarz
and Nutt (1963).
In Brazil, the studies on aerated spillways were intensied during the construction o the hydropower
dams in the 1970 and 1980 decades. The rst relevant conclusions or spillways were presented by Pinto et
al. (1982), while Borsari (1986) and Fuentes (1992) urnished reviews o important studies and procedures.
These aerator studies helped in the establishment o locally adopted procedures. Some early studies,
like Volkart (1980) and Wood (1985), added important conceptual contributions or the understanding o
aerated fows. Practical applications o the research results, however, require more detailed measurements
and the review o existent results. Kkpinar and Ggs (2002) conducted an extensive experimental study
and urnished correlations not only or the jet length, but also or the air entrainment in lower and uppernappes, and a graphical presentation o the eect o ramp heights and bed slopes. The redistribution o
fow velocity in the aeration zone was considered by Toombes and Chanson (2005), while the details o the
geometry o the air-water interace were used to propose the concept o entrapped air by Wilhelms and
Gulliver (2005). A similar entrapped air concept was used by Lima et al. (2008) to explain measurements
o air void ratios in lower nappe aeration.
This paper seeks to compare CFD simulations with a detailed experimental study o the lower nappe
o a jet generated by an aerator in a laboratory chute. Measurements o velocity elds, pressure and air
concentration (void ratio) proles will be compared to CFD results. The CFD simulations o air discharges
were comparable to the measured values. It is also shown that, i a more detailed description is needed,
experiments are still necessary.
EXPERIMENTAL METHODS
The experiments were conduced in a chute built in the Laboratory o Environmental Hydraulics o the
School o Engineering at So Carlos, Brazil. The chute had a slope o 14.5, an useul length o 5.0 m, with
a rectangular cross section 0.20 m wide and 0.50 m high. The bed aerator was composed o a ramp with a
length o 23.0 cm, a nal height tr = 4.0 cm and an angle o 10 relative to the chute. The chamber under
the jet had a depth o 12.0 cm, a length o 18.0 cm and a width o 20.0cm. The air discharge was measured
in the air supply tube, which had a diameter o 71.65mm. Air velocities were obtained rom pressure
measurements, with a micromanometer having one side opened to the atmosphere and the other xed in a
pre-calibrated position in the tube. The concentration measurements in the fow were made with a Cesium
137 probe, as shown in Figure 1. Calibration was made with the channel a) ull with water and b) empty.
The Cesium 137 radiation was projected perpendicularly to the fow in the channel and a counter registered
the remaining radiation ater passing the mixture o air and water and the glass walls. The concentration
measurements thus consider the entire width o the channel. Air concentration proles were obtained by
positioning the probe and radiation counter along the vertical o every studied cross section. Each obtained
concentration is a horizontal mean value transverse to the fow direction.
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
3/17
BED AERATION IN SMOOTH CHANNELS: EXPERIMENTS AND NUMERICAL SIMULATION 523
Fig. 1 Equipment used or the concentration measurements with Cesium 137 probe.
An electromagnetic fow meter was used to measure the water discharges, which were checked with
a rectangular weir located at the outlet o the channel. The measurement o velocity elds in the jet was
perormed or nine runs, using a mirror inside o the fow. Velocity elds were measured using particle
image velocimetry (PIV). The light source was a copper gas Laser, with a mean power o 20 W and pulses
at 10 kHz. The pulse power ranged rom 60 to 140 kW. Generated wavelengths were 510.6 nm (green)
and 578.2 nm (yellow). A CCD camera with a resolution o 1024 pixels 1024 pixels was used to record
the images. Ater capturing and storing the images in the computer, PIV sotware was applied to each
image to obtain velocity vector elds by using auto-correlation calculations. 234 images were taken or
each run. Figure 2 shows all cross sections used in the present study. Sections 1, 2 and 3 were used to
obtain the approach fow inormation (velocity and water depth). Sections 4 through 8 were used or theconcentration measurements. Additional sections SIX and SX were used or velocity measurements in the
jet core. For velocity measurements in sections 1 and 2, the laser sheet was introduced in the fow rom the
bottom o the channel.
Fig. 2 Measurement sections or the present study. Distances are in centimeters.
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
4/17
524 EUDES J. ARANTES et al.
For velocity measurements in the jet core, a mirror was positioned downstream in the jet beore the
upper and lower white water regions came together, as shown in Figure 3, and the laser sheet was intro-
duced into the fow rom the side o the channel. Detailed descriptions o the chute and the measurement
equipment may be ound in Carvalho (1997) and Lima (2004).
Fig. 3 Experimental arrangement or the velocity measurements in the jet core using a mirror.
SIMULATION METHODS
In this study, the inhomogeneous multiphase model was applied with the liquid and the gaseous phases
considered. There is one solution eld or each separate phase, and the fuids interact via interphase transer
terms. For example, the two phases may have separated velocity and temperature elds, but there will be a
tendency or these to come to an equilibrium through interphase drag and heat transer terms (CFX 2004).
The ollowing equations or inhomogeneous multiphase fow were used to simulate the air and waterfows, and air uptake:
Continuity Equations:
t
raa
+
raa a
= SMSa +
Npb=1
ab (1)
Momentum Equations:
t
ra a a
+
ra
a a a=
rapa +
raa a +
a
T+
Npb1
+ab b +ba a
+ SM A + Ma
(2)
where: ra is the volume raction o each phase (phases indicated by a, with a assuming values rom
1 to Np, the total number o phases), a is the density o phase a,Ua is the velocity vector o phase
a, a is the viscosity o phase a, SMSa represents mass sources specied by the user; ab is the mass
fow rate per unit volume rom phase b to phase a. This term only occurs i interphase mass transer
takes place; SMa represents momentum sources due to external body orces, and Ma represents interacial
orces acting on phase a due to the presence o other phases. The term
+abUb
+ba
Ua
represents
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
5/17
BED AERATION IN SMOOTH CHANNELS: EXPERIMENTS AND NUMERICAL SIMULATION 525
momentum transer induced by interphase mass transer. The volume ractions o the phases sum to unity,
that is:Npa=1
ra = 1 (3)
There are 4NP+ 1 equations to describe the fuid dynamics or the 5NP unknowns ra, Ua||, ||Va, Wa,
(components o the velocity vectorial eldUa), and Pa (the pressure eld o each phase). The additional
NP 1 equations needed to close the system o equations were supplied by assuming that all phases
shared the same pressure eld, P, that is:
Pa = P or all a = 1, . . . , NP (4)
A scalar variable in phase a has the corresponding transport equation:
traaa+ raa a a ra aD()a +
ta
Sctaa = S()a + T()a (5)
where D()a is the Diusivity o a, S()a represents an external source in phase a, and T
()a represents
sources oa due to interphase transers. Details o the multiphase model may be ound in CFX (2004).
To initialize a simulation, a relatively gross mesh was rst used to locate the air-water interace. Then,
the regions o the upper and lower ree suraces were rened, allowing a detailed location o the interace
or the denitive run. The nal mesh o each case presented a higher concentration o cells in the upper
and lower nappes o the jet, as shown in Figure 4. Details are described by Arantes (2007). Table I shows
the main characteristics o the grids and the simulated fuids (air and water). The number o nodes and
elements o the grids are mean values or all simulated conditions.
Fig. 4 Example o rened mesh used or the numerical calculations.
The model allows the adjustment o constants and boundary conditions in order to calibrate the pre-
dictions with measured results. Dierent combinations were tested, but they in general reproduced only
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
6/17
526 EUDES J. ARANTES et al.
TABLE I
The Domain, Fluids and Simulation characteristics,
initial and boundary conditions.
Domain (ater adaptation)
Number o Nodes 550000Number o Elements 2750000
Fluid: Water
Temperature 25C
Dynamic Viscosity 8.899*104 kg.m1.s1
Density 998 kg.m3
Surace Tension Coe. 0.0732 N.m1
Fluid: Air
Temperature 25C
Dynamic Viscosity 1.831*105 kg.m1.s1
Density 1.185 kg.m3
Simulation
Time step 0.1 s
Simulation Time 10 s
Processor Processor 3.2 GHz
Characteristics (Opteron 64 bits)
CPU Processing time 1*105 s
a portion o the observed results. The CFX standard constants and conditions, on the other hand, led to
acceptable predictions or the whole set o experiments, being thus used in this study.
The conditions in the inlet were imposed as:
Pressure: hydrostatic pressure,
Turbulence intensity: xed at 5% o the water velocity (standard or CFX),
Turbulence model: SSG Reynolds Stresses using CFX standard parameters. The model allows the
simulation o non-isotropic situations, and the use o the law o the wall.
Roughness or the law o the wall: 1.0 mm.
The calibration was primarily based on the predictions o the jet lengths.
RESULTS AND DISCUSSION
Fourteen runs were conducted in the chute. Table II provides the experimental conditions. The jet length
o run 2 is not available because the jet was longer than the channel. Velocity eld measurements using
PIV were perormed in the nine runs indicated by (*). Results o all ourteen runs were used to check the
reproducibility o the data, while the results o the nine runs with velocity data were used to compare with
CFD predictions.
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
7/17
BED AERATION IN SMOOTH CHANNELS: EXPERIMENTS AND NUMERICAL SIMULATION 527
TABLE II
Experimental conditions.
Run
OpeningDepth Water Velocity Froude Jet Air fow Air Water
o theat S2 fow rate at S2 Number Length rate Temp. Temp.
foodgate h (cm) Qw (l/s) Vw (m/s) Fr L (m) Qai r (l/s) (C) (C)H (cm)
1*3
3.37 45.77 6.79 11.81 2.08 23.06 27.5 24.2
2* 3.51 63.93 9.11 15.52 NA 27.82 26.0 25.1
3* 5.26 47.65 4.53 6.31 1.08 12.66 24.0 22.0
46
5.50 58.85 5.35 7.28 1.38 18.37 24.7 24.0
5* 5.40 64.37 5.96 8.19 1.48 20.17 25.5 24.1
6* 5.85 92.05 7.87 10.39 2.28 29.49 23.0 24.1
7 6.00 44.44 3.70 4.82 0.78 9.92 29.0 28.0
8*9
7.05 64.38 4.57 5.50 0.98 14.26 28.0 22.5
9* 8.31 98.20 5.91 6.55 1.48 22.92 21.4 21.0
10 8.54 119.86 7.02 7.67 2.08 31.69 29.0 22.011 6.92 46.58 3.37 4.09 0.68 11.28 23.8 21.8
12*11
7.94 64.38 4.05 4.59 0.88 15.52 25.8 23.0
13* 9.10 94.64 5.20 5.50 1.18 20.28 25.8 22.1
14 10.16 128.76 6.34 6.35 1.58 27.45 21.4 21.0
COMPARISON OF MEASUREMENTS WITH LITERATURE
Verifcation o the jet length L
Jet lengths are commonly used to quantiy the air uptake by the water fows. The jet lengths o Table IIwere compared with theoretical predictions o Schwarz and Nutt (1963) and Tan (1984), given respectively
by equations 6 and 7, and plotted in Figure 5. Also shown are the predictions o the empirical correlation
o Kkpinar and Ggs (2002), given by equation 8. The theoretical equations 6 and 7 were obtained with
no restrictions to . Equation 8 was adjusted rom experimental data, being thus restricted by the range o
tested during the experiments. A systematic underestimation o equation 8 is observed, which may be
due to extrapolations o its limits o application. For example, the ramp slope is limited to 0 < < 9.45,
but in this study = 10.
The good agreement between measured and literature results is taken as an indication that the experi-
mental data or jet length can be used to compare with CFD simulations.
L
h=
(1+ tan )
cos Fr2
1+
1+ 2
tr + ts
h
cos
(Fr)2
+
tr+ ts
htan (6)
L
h=
gsin
2ht2 +
(V cos )
ht, t=
V sin
g
cos + Pwgh
1+
1+ 2(tr+ ts )
g
cos + Pwgh
(V sin )2
(7)
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
8/17
528 EUDES J. ARANTES et al.
L
h= 0.28(1+ )0.22 Fr1.75
tr+ ts
h
0.44 (1+ tan )
Aa
Aw
0.087(8)
In the above equations, is the ramp slope, is the chute slope, is the take o angle (which is the
angle ollowed by the liquid when it leaves the ramp. is equal to because no inertial eects alteredthe observed direction o the fow ater leaving the ramp), tr is the ramp height, ts is the step height (zero
in the present experiments), t is the time, w is the water density, g is the gravity acceleration, P is the
relative pressure under the jet (taken positive), h, V, Fr and L are dened in Table I, and Aai r/Aw is the
ratio between the air supply pipe entrance area, Aa, and the area o the water fow beore the aerator, Aw.
Fig. 5 Predicted and measured jet lengths.
Verifcation o the air entrainment coefcient as a unction oL/ h
Pinto et al. (1992) proposed that the ratio between Qai r and Qw||, ||Qai r/Qw, is proportional do L/ h,
with a coecient o proportionality between 0.023 and 0.033. Rutschmann and Hager (1990) ound a
coecient o proportionality o 0.030, or the maximum value o (zero relative pressure in the cavity
under the jump). The authors showed that the straight line o vs. L/ h intercepted the L/ h axis around
L/ h = 5 or a rst set o data, so that the equation = 0.030(L/ h 5) was proposed. For a second set o
data, the simple proportionality = 0.030L/ h was ollowed. The authors measured L/ h up to around 45.
Chanson (1991) suggested that and L/ h ollow linear trends with lower slopes or L/ h < 20 and higher
slopes or L/ h > 20. The L/ h values ranged up to around 25. Kkpinar and Ggs (2002) presented the
empirical correlation
= 0.0189(L/ h)0.82
Aa/A2
(1+ tan 0.24
(9)in which the coecient o = (L/ h) depends on the channel slope ( ) and the ratio Aai r/Aw. L/ h
ranged up to 30. Equation 9 shows a nonlinear dependence between and L/ h, and that the coecient
may be lower than 0.0189. The equation is valid or 0 < < 51.3.
Figure 6 shows against L/ h or the data o these experiments. A constant seems to occur orL/ h
between 10 and 15. However, as no measurements were made or L/ h < 10, this apparent constancy may
be only the scatter o the data. Figure 6 also shows the region containing the lower nappe data o Low (1986)
and analyzed by Chanson (1991), obtained or a chute slope = 52.33; and the equations o Rutschmann
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
9/17
BED AERATION IN SMOOTH CHANNELS: EXPERIMENTS AND NUMERICAL SIMULATION 529
and Hager (1990), or = 51.3 and = 34.4. The dependence o the unction = (L/ h) on
geometrical characteristics, such as the slope o the spillway, is clearly visible. Applying equation 9 or the
conditions o this study ( = 14, 5) led to good predictions o the measured data, with deviations occurring
or the lower range o L/ h. These deviations may be due to the extrapolations o the application limits o
equation 9 or bias in the measurements. As already mentioned, the used ramp slope = 10 extrapolates
the 0 < < 9.45 limits. Also the experimental range o Froude numbers (Fr), 4.08 < Fr < 15.5,
extrapolates the application limits o equation 4, given as 5.56 < Fr < 10.00. However, equation 9 shows
that the data ollowed the general expected behavior or the applied experimental conditions, indicating that
the experimental data or air/water fow ratio can be used to compare with CFD simulations.
Fig. 6 Measured and L / h values, together with data and correlations rom other authors. is the angle o the spillway in each
experiment. The present set o data approximates to the general trend o the correlation o Kkpinar and Ggs (2002).
Verifcation o the air entrainment coefcient as a unction oFrFigure 7 shows the data o the present study (white circles) and those o Kkpinar and Ggs (2002)
(gray circles) against the Froude number. The data o Kkpinar and Ggs were obtained or fows over a
step height ts o 5 cm, while, or the present data, ts = 0. Moreover, theirtr/ h values ranged rom 0.0 to
0.4, while in the present study they ranged rom 0.4 to 1.2. The dierent experimental conditions generated
clouds o points with similar trends, but separated in the graph vs. Fr, as shown in Figure 7.
Fig. 7 Measured against the Froude number.
To consider the dierent parameters in a correlation or , a dimensional analysis leads to
= f
Fr ,
tr
h,
ts
h
(10)
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
10/17
530 EUDES J. ARANTES et al.
The combined eect o tr and ts is represented here through the ratio (tr + k ts )/ h, where k is an
adjusted constant. A multiple regression analysis urnished the result
= 0.0278 Fr1.044 tr+ 3ts
h0.460
(11)
Predicted and measured data are presented in Figure 8, showing that the present data and those rom
literature are complementary and orm a single cloud o points. The agreement between present and
literature data (Figs. 5, 6 and 8) allowed the use o the corresponding experimental results o air concen-
tration proles, pressure proles, velocity proles and air discharges to compare to the CFD predictions.
Fig. 8 Calculated obtained using equation 6 against measured .
COMPARISON OF CFD PREDICTIONS WITH EXPERIMENTS
Jet length
Table III shows six predictions o the jet length. As mentioned, the turbulence conditions were adjusted in
the inlet o the numerical domain, but the CFX standard parameters o the turbulence model urnished the
best predictions or the set o jet lengths. These conditions were similar or all runs. The simulated lengths
were in the range o 0.81 to 1.08 times the measured length or the six runs. These runs were used to obtain
numerical air discharges.
TABLE III
Simulated runs, showing predicted and measured
lengths of the jet.
Measured Predicted LpredictedLmeasured
Run Length Length
(m) (m)3 1.08 1.17 1.08
5 1.48 1.18 0.81
8 0.98 1.02 1.04
9 1.48 1.32 0.89
12 0.88 0.88 1.00
13 1.18 1.21 1.03
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
11/17
BED AERATION IN SMOOTH CHANNELS: EXPERIMENTS AND NUMERICAL SIMULATION 531
Pressure distribution
The pressure distribution along the channel bed was used to measure the jet length, taken as the position o
the pressure peak. Figure 9 presents an example measurement and simulation results or run 13, showing
good agreement between CFD simulations and the experiment.
Fig. 9 Pressure distribution along the channel bed or run 13. The axis x
represents the longitudinal distance with origin taken at the beginning o the jet.
Velocity distribution
The velocity distribution in section S3, measured using the PIV technique, was compared with the predicted
distribution. Figure 10 shows the comparison or runs 3 and 5, taken as examples. The agreement between
measured and predicted proles is considered acceptable, having a maximum dierence o ten percent. The
imposed turbulence intensity in the inlet o the numerical domain, maintained constant or all simulations,
may be a cause o the observed deviations. No numerical bias o the related concentration elds were
observed (see Fig. 11), so that the obtained velocity distributions were considered adequate or this study.
Fig. 10 Velocity distributions or runs 3 and 5.
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
12/17
532 EUDES J. ARANTES et al.
Fig. 11 Void ratio proles along the jet upstream o the reattachment section (run 5).
Concentration profles
Lima et al. (2008) presented measured values or the air discharge entering into the cavity under the jet, and
also values obtained calculating the air discharge rom air concentration proles measured at cross sections
along the lower nappe o the jet. The authors applied Equation (12) along sections 4 through 8 (Fig. 2),
corresponding to a distance between 3.9% and 132% o the jet lengths.
Qx = B
Upper boundary
Lower boundary
C(y)Vx (y)d y (12)
where Qx is the air discharge, B is the channel width, C is the air concentration (void ratio), Vx is thevelocity in the x direction and y is the distance normal to the chute ace. The upper and lower boundaries
o the domain were set at two conditions: 1) C values o 95% and 5%, and 2) C values o 90% and 10%.
Lima et al. (2008) showed that the measured air discharges are substantially lower than the air dis-
charges evaluated rom the concentration proles. Previous results o Wilhelms and Gulliver (2005), when
evaluating entrained air rom concentration proles or upper surace aeration, showed that corrections must
be made because the measurements involve air among water parcels o the surace distortions, not absorbed
by the water. Lima et al. (2008) suggested that a similar eect infuenced the measurements along the lower
nappe, with the addition o the eect o the spray that emanates rom the aerator lip as water. Substantial
sprays could account or water measurement throughout the air pocket, aecting the air discharge results.
Numerical predictions o air concentrations are shown in Figure 11. Run 5 is presented becauseit represents the worst agreement between the measured and predicted jet lengths (predicted length =
81% o measured length). Even or this condition, the agreement between measured and predicted
concentration proles is good. The displacement observed between proles, mainly or sections S7
and S8, is due to the lower predicted position o the jet when compared with the measured position.
Measurements and predictions considered the entire thickness o the jet.
All proles o Figure 11 were obtained upstream o jet reattachment with the channel bed. Figure 12a
shows the predicted concentration eld along the jump. Figures 11 and 12 show that the concentration
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
13/17
BED AERATION IN SMOOTH CHANNELS: EXPERIMENTS AND NUMERICAL SIMULATION 533
Fig. 12 a) Concentration eld along the jet, showing the end o the region o the water core with zero air concentration (arrow).
b) A sketch o a possible path ollowed by a bubble originated in the upper nappe.
proles o the upper and lower nappes interact downstream o the position indicated by the black arrow
in Figure 12a, where the concentration in the water core ceases to be zero (shown in black). Non-zero airconcentrations in the core are related to bubbles originating either at the upper or at the lower suraces.
Figure 12b shows a sketch o an eventual intrusion o air originated in the upper nappe. In this case,
concentration measurements can also be aected by this new air source, and air discharges obtained rom
concentration measurements can eventually be dierent rom those measured in the inlet structure.
The measured and calculated concentration proles or the impact region could also be compared or
one run o the present set o experiments. Figure 13 shows the results obtained or run 12 at section 8, the
only case in which the pressure point that quanties the jet length coincided with a measurement section.
Although the general behavior o both proles is the same, substantial dierences are observed between
the concentration values. The measured prole is, in general, steeper than the calculated prole, and the
concentration dierences are higher or distances to the channel bottom between 0 and 5 cm. Also in
this case, the dierences may result rom the turbulence condition imposed in the inlet o the simulation
domain. For example, higher levels o homogenization (soter proles) are obtained or higher turbulent
diusivities, which are dependent on the turbulent conditions.
Fig. 13 Void ratio prole at the impact section. (Run 12, section 8).
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
14/17
534 EUDES J. ARANTES et al.
Air discharges
Predicted air discharges are compared with measurements or the six simulated cases presented in Fig-
ure 14. Although the predicted air discharges have the same magnitude as the measured air discharges, a
relatively high spread is observed. The predicted air discharges were obtained by integrating air concen-tration at the cross section o the inlet tube (Fig. 2). The dierences between experimental and numerical
data are probably associated with the constant parameters o the turbulence model (the CFX standards
were used) or the dierent experimental situations, and the constant turbulence intensity in the inlet o the
numerical domain (5%), as previously mentioned. As shown by Ervine et al. (1995), the air uptake by the
water depends on the turbulence intensity perpendicular to the fow direction.
Fig. 14 Comparison between measured and predicted air dis-
charges, or the six conditions simulated in the present study.
Theresults indicate that, ora rst evaluation o themagnitudeo theairdischarge, numerical procedures
can be used to help in the decision-making process. However, the numerical code must be calibrated, based
on measured characteristics. In the present study, the jet lengths were used to calibrate the model (to adjust
parameters and inlet conditions), and the measured concentration, pressure, and velocity proles were used
to check the numerical results. I more detailed inormation is needed, say or cavitation erosion potential, it
is still necessary to conduct experimental studies and to scale up the results based on empirical procedures.
CONCLUSIONS
Experimental studies on air absorption by fows over a bed aerator were described and compared with
theoretical and empirical predictions ound in the literature and computational results conducted here.
1. Jet lengths were well predicted by the equations o Schwarz and Nutt (1963) and Tan (1984). The air
entrainment coecients , when expressed as a unction o L/ h, were well predicted by the equation
o Kkpinar and Ggs (2002), unless or the lower range o L/ h, that is, or 10 < L/ h
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
15/17
BED AERATION IN SMOOTH CHANNELS: EXPERIMENTS AND NUMERICAL SIMULATION 535
data here described and those o Kkpinar and Ggs (2002) can be presented together, ollowing
the same trend.
2. Computational predictions o the jet length were taken as control parameter or the numerical sim-
ulations (calibrations). The CFX standard parameters were adopted or the turbulence model. The
turbulence intensity at the inlet was xed at 5% o the mean fow velocity, and the roughness used in
the law o the wall was xed at 1.0 mm, which generated predicted jet lengths between 0.8 and 1.2
times the measured length.
3. It was observed that the pressure distribution alongthe channel bed, the velocity proles at the end o the
ramp, and the concentration proles along the jet could be represented by the calibrated computational
code. Considering the air concentration at the impact point, the measured and predicted proles
presented the same general orm, although concentration dierences were observed.
4. The computational predictions o the air discharges ollowed the magnitude o the measured data.
However, a relatively large scatter was observed. For a rst evaluation o the magnitude o the airdischarge, computational procedures can be used to help in making decisions. However, the numerical
code must be calibrated, based on previous measured characteristics. In the present study, the jet
lengths were used to calibrate the model (to adjust parameters and inlet conditions), and the measured
concentration, pressure, and velocity proles were used to check the numerical results.
NOMENCLATURE TABLE
a a physical phase t time
A amplitude o oscillation tr ramp height
Aa area crossed by air ts step height
Aw area crossed by water T()
a sources oaB channel width
Ua velocity vector o phase a
C air concentration (void ratio) Ua , Va , Wa components oUa
D()a diusivity oa V generic velocity
Fr Froude number Vx velocity in the x direction
g acceleration o gravity x longitudinal axis
h height y distance normal to the chute ace
L jet length ramp slope
Ma interacial orces acting on phase a take o angle
Np total number o physical phases air entrainment coecients ( = Qa /Qw)
Pa pressure eld o phase a ab specic mass fow rate rom phase b to aQa air discharge a conserved specic variable o phase a
Qw water discharge P relative pressure under the jet
ra volume raction o phase a a viscosity o phase a
S()a external source in phase a chute slope
SMa momentum sources a density o phase a
SMSa mass sources w water density
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
16/17
536 EUDES J. ARANTES et al.
ACKNOWLEDGMENTS
The authors thank Pros. M.A. Kkpinar and M. Ggs, who urnished the data used in Figures 7 and 8;
Coordenao de Apereioamento de Pessoal de Nvel Superior (CAPES pr. 2201/06-2) and Fundao
de Amparo Pesquisa do Estado de So Paulo (FAPESP), or supporting this research. The authors do nothave any propriety and nancial interest in any product or company cited in this manuscript.
RESUMO
Aeradores de undo projetados para aumentar a concentrao de ar so utilizados para previnir a cavitao e danos
dela derivados em vertedouros. O oxignio contido na gua tambm um parmetro relevante para garantir alta
qualidade das guas a jusante do vertedouro, com refexos na qualidade ambiental. Equaes e critrios de projeto
existentes ainda so considerados aproximados, mostrando a necessidade de mais estudos para elucidar os meca-
nismos que governam o carreamento de ar. Este trabalho apresenta resultados de uma srie sistemtica de medidas
de concentrao de ar ao longo da supercie inerior do jato de um aerador de undo, juntamente com medidas
pertinentes de descargas de ar e campos de velocidade da gua. Foram eitas comparaes com resultados da lite-
ratura, considerando pers de concentrao ao longo do jato do aerador at a regio de jusante. As medies sob
condies controladas orneceram inormaes necessrias para testar resultados numricos de aerao obtidos em
simulaes desses escoamentos, utilizando mecnica dos fuidos computacional (CFD). Mostra-se que erramen-
tas numricas preditivas ornecem vazes de ar comparveis aos valores medidos. Tambm concludo que, se
detalhes so necessrios, experimentos so ainda teis.
Palavras-chave: aeradores de vertedouros, carreamento de ar, escoamento ar-gua, escoamentos multisicos.
REFERENCES
ARANTES EJ. 2007. Caracterizao do Escoamento sobre Vertedores em Degraus via CFD. Tese de Doutorado,
Escola de Engenharia, Universidade de So Paulo, So Carlos, Brasil, 204 p.
BORSARI RD. 1986. A cavitao do Escoamento sobre Vertedores em Degraus via CFD. Tese de Doutorado, Escola
de Engenharia, Universidade de So Paulo, So Carlos, Brasil, 246 p.
CARVALHO PD. 1997. Aerao de Escoamentos de Alta Velocidade em Canais de Forte Declividade. Tese de
Doutorado, Escola de Engenharia, Universidade de So Paulo, So Carlos, Brasil, 387 p.
CFX. 2004. CFX 5 Solver Theory. Ansys Canada Ltda, Waterloo, Ontario, Canada, 250 p.
CHANSON H. 1991. Aeration o a Free Jet Above a Spillway. J Hydraul Res 29(5): 655667.
ERVINE DA, FALVEY HT AN D KAH N AR. 1995. Turbulent Flow Structure and Air Uptake at Aerators. Hydro-power and Dams, September, 8996.
FUENTES R. 1992. Modelacin Fsica en Hidrulica (Physical Modeling in Hydraulics), Actas del curso pr-
congreso del XV Congreso Latinoamericano de Hidraulica, IAHR, Universidad de Cartagena, Colmbia.
KKPINARMA AND GGS M. 2002. High-speed Jet Flows Over Spillway Aerators. Can J Civ Eng 29: 885898.
LIM A ACM. 2004. Caracterizao da estrutura turbulenta em escoamentosaerados em canal de orte declividadecom
auxlio de tcnicas de velocimetria a laser. Vols. 1 e 2. Tese de Doutorado, Escola de Engenharia, Universidade
de So Paulo, So Carlos, Brasil.
An Acad Bras Cienc (2010) 82 (2)
-
8/3/2019 ARANTES_et_al_Lower Nappe Aeration in Smooth Channels
17/17
BED AERATION IN SMOOTH CHANNELS: EXPERIMENTS AND NUMERICAL SIMULATION 537
LIM A ACM, SCHULZ HE AND GULLIVER JS. 2008. Air uptake in the lower nappe o a spillway aerator. J
Hydraulic Res 46(6): 839843. doi:10.3826/jhr.2008.3296.
LOW HS. 1986. Model Studies o Clyde Dam Spillway Aerators. Master Report, Re 86-6, University o Canterbury,
New Zealand.
PAN S, SHAO Y, S HI Q AND DONG X. 1980. The Sel-aeration Capacity o the Water Jet Over the Aeration Ramp.
J Hydr Engrg (Shuili Xuebao in Chinese with abstract in English), Beijing, PRC, 5, Oct, 1322.
PINTO NL DE S, NEIDERT SH AND OTA JJ. 1982. Aeration at High Velocity Flows. Water Power and Dam Constr
34-38: 4244.
RUTSCHMANN P AN D HAGERWH. 1990. Air Entrainment by Spillway Aerators. J Hydr Engrg 116(6): 765782.
SCHWARZ I AN D NUT T LP. 1963. Projected Nappes subjected to Transverse Pressure. J Hydr Div ASCE 89(7):
97104.
TAN P. 1984. Model Studies o Aerators and Spillways. Research Report 84-6, Dept Civil Engg,Univ o Canterbury,
Christchurch, New Zealand.
TOOMBES L AN D CHANSON H. 2005. Air Entrainment and Velocity Redistribution in a Bottom Outlet Jet Flow.
XXXI IAHR Congress, September 11 to 16, Seoul, Korea, 27162726.
VOLKART P. 1980. The Mechanism o Air Bubble Entrainment in Sel-Aerated Flow. Int J Multiphase Flow 6:
411423.
WILHELMS SC AND GULLIVERJS. 2005. Bubbles and Waves Description o Sel-aerated Spillway Flow. J Hydraul
Res 43(5): 522531.
WOO D IR. 1985. Air Water Flows, Keynote address, Proceedings o the 21th IAHR Congress, Melbourne, Australia,
6: 1829.
An Acad Bras Cienc (2010) 82 (2)