arb editing software · 2018-01-19 · waveform editing software - [wave edit(e) setup(s) 32,767...

8
How to use ARB Editing Softwarwe? A. Connection 1. Please execute the Device Manager (Route: Windows>computer>Device Manager) 2. Check the com ports

Upload: others

Post on 28-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ARB Editing Software · 2018-01-19 · Waveform Editing Software - [Wave Edit(E) Setup(S) 32,767 Start point 24,575 200,1 ngth±500 -200 700 16,384 8,192 -16,384 -24,575 -32,767 Send

How to use ARB Editing Softwarwe? 

 

A. Connection 

 1. Please execute the Device Manager   

(Route: Windows>computer>Device Manager) 

 2. Check the com ports

 

 

 

 

 

Page 2: ARB Editing Software · 2018-01-19 · Waveform Editing Software - [Wave Edit(E) Setup(S) 32,767 Start point 24,575 200,1 ngth±500 -200 700 16,384 8,192 -16,384 -24,575 -32,767 Send

3. Open the Arb Waveform Editing Software 

 

 4. Set the interface that you use   

(GPIB,USB,LAN) 

 

 

 

 

 

 

 

  

 

Page 3: ARB Editing Software · 2018-01-19 · Waveform Editing Software - [Wave Edit(E) Setup(S) 32,767 Start point 24,575 200,1 ngth±500 -200 700 16,384 8,192 -16,384 -24,575 -32,767 Send

5. Check the com port again 

(Route: Setup> Config I/O>Option) 

(EX :My AFG‐CDC is COM7) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 4: ARB Editing Software · 2018-01-19 · Waveform Editing Software - [Wave Edit(E) Setup(S) 32,767 Start point 24,575 200,1 ngth±500 -200 700 16,384 8,192 -16,384 -24,575 -32,767 Send

B. Edit 

 1. MaxEditLength means the max waveform length 

  

 

 

Page 5: ARB Editing Software · 2018-01-19 · Waveform Editing Software - [Wave Edit(E) Setup(S) 32,767 Start point 24,575 200,1 ngth±500 -200 700 16,384 8,192 -16,384 -24,575 -32,767 Send

2. After Step 1 ,The pop‐up window will show the parameter. 

You can set the sample rate and the horizontal length.   

If you set the horizontal length to 10k, it will zoom in to 10k points.(ex.) 

But the max length is still 1M.                                                                       

 

 

 

 

Page 6: ARB Editing Software · 2018-01-19 · Waveform Editing Software - [Wave Edit(E) Setup(S) 32,767 Start point 24,575 200,1 ngth±500 -200 700 16,384 8,192 -16,384 -24,575 -32,767 Send

3. The basic waveform. 

If you want to create a basic waveform, every settings will change by key‐ 

in. 

Sample Rate(Hz)/points=Frequency , 200MHz/1k = 200kHz 

But it means the sine wave is 200k not the output . 

     

 

 

 

 

Page 7: ARB Editing Software · 2018-01-19 · Waveform Editing Software - [Wave Edit(E) Setup(S) 32,767 Start point 24,575 200,1 ngth±500 -200 700 16,384 8,192 -16,384 -24,575 -32,767 Send

               

4.Set the waveform to instrument   

(1)From wave: It means which part of waveform that you want to select. 

(2)To instrument : It means the start point of instrument .       

(3)Output: It means the output range. The frequency is also decided by 

the points. Sample Rate(Hz)/points=Frequency                                                   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 8: ARB Editing Software · 2018-01-19 · Waveform Editing Software - [Wave Edit(E) Setup(S) 32,767 Start point 24,575 200,1 ngth±500 -200 700 16,384 8,192 -16,384 -24,575 -32,767 Send

EX.Setting   

(1)From wave : 

Start :200,length:500 

 

(2)Output: 

Start:0,length:700 

0~699=700 Points 

Frequency = Sample Rate/Points=>200MHz/700Points=285.71